Loading...
HomeMy WebLinkAboutBLD22570 Duplex - BLD Application - 8/19/1988 BUILDING PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED q_e-y� PERMIT NO ,- OWNER NAME MAILADDRESS CITY&STATE ZIP PHONE I--bt.lC P 0. �X GI(-1 14ACE&C WA, 9 e3-;336 851 - 5;57 DIRECTIONS TO JOB SITE F-161 -I-T pt4 p`( F_2,oLp RO D F F 4W`( �kC Cao %Z µ I LE- -cv Yv_-LLc>\,J 2 t e*?-0t'l c;'N PROPe2TY F_KT C>S. Ac Ro» Rc�/ap p LSc�, RpK ipIr-)F o4 v'/OoP! r PARCEL LEGAL NUMBER -z 2g 14c1UtZ() DESCR �OT B of - �40tZT pL1�-1' NAME MAIL ADDRESS CITY&STATE LICENSE N Z PHONE CONTRACTOR ► m rr HO P, k l �t (-�A�2 �` N2 =1Z 'R51 -&v53'7 USE OF BUILDING t L� CLASS OF NEW ADDITION ALTERATION REPAIR MOVE REMOVE WORK ✓ DESCRIBE WORK Ccw STiZ t1C-T►0 0 (c\�/ �l�l f�� IM E�,1.1�-72 Paz BEDROOMS DECKS CARPORT 49L� NOTICE SEPARATE BATHROOMS TOTAL SQ.FT: GARAGE CONDITIONING.PER ARE REQUIRED FOR PLUMBING, HEATING, VENTILATING OR AIR NO.OF STORI ES BASEMENT Q ATTACHED I/- THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED OR TOTAL SO.FT. FIREPLACE a DETACHED ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. PERMANENT SHORELINE 'C" SEASONAL µ OWNERS FIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY AT I AM EXEMPT FROM THE REQUIREMENTS OF THE CONTRACTORS I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRACTOR IN THE STATE OF REGISTRATI N LAW RCW 18.27, AND AM AWARE OF THE MASON COUNTY ORDINANCE WASHINGTON AND I AM AWARE OF THE ORDINANCE REQUIREMENTS REGULATING THE REQUIREM TS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK DONE WILL BE WORK FOR WHICH THE PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN IN CONF MANGE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST CONFORMANCE THEREWITH.NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING OBTAININ APPROVAL FROM THE BUILDING DEPARTMENT. APPROVAL FROM THE BUILDING DEPARTMENT. X 0 W N E d!/ ( uDATE '� XBY � ` f- G( DATE FOR OFFICE USE ONLY J DEPARTMENT YES APPROVEDJO DEPARTMENT YES DEPARTMENTBUILDING VALUATION HEALTH G 6 PUBLIC WORKS FEE PLANNING FIRE BUILDING PERMIT D.O.T. BUILDING PLAN CHECK 2 SPECIAL CONDITIONS BUILDING GROUP PRE-INSPECTION SHORELINE WOODSTOVE G 11 l A 3d- PLUMBING L" rJ � �. " MECHANICAL Y� STATE BUILDING FEE 977 / STATE SURCHARGE i APPLICATION ACCEPTED BY /PL�A�NS CHECK BY APPROVED FOR ISSUANCE PERMIT VALIDATION B�t/k ""� ff� CASH CK MO TOTAL l Z/r a� PLUMBING & MECHANICAL PERMIT APPLICATION MASON COUNTY DEPARTMENT of GENERAL SERVICES P.O. BOX 186 SHELTON, WASHINGTON 98584 427-9670 DATE ISSUED PERMIT NO. NAME MAIL ADDRESS CITY&STATE ZIP PHONE OWNER Lc)r4 P la k3ox k Cli cg $c--,3'7 DIRECTIONS TO JOB SITE ' 1(--A P.Cj` [ � �� (jFF \�/ 3�� 61U VZ fAi LE lZ 1 E>k?-o N p t`I L ��Z C,2o P r=2T`f :x T€t�l IDS 'L irzass i2�6P'D A-L so, -vu LEGAL c DESCR. Lc,-i- CONTRACTOR NAME MAILADDRESS CITYBSTATE LICENSE NO. ZIP gssa PHONE Ste+ Mir I�an�s P.o. �gc�Z wA SuHM�►� Iz3D -dS3� USE OF BUILDING PLUMBING FIXTURES MECHANICAL FIXTURES NO. 2.00 PER FIXTURE OR TRAP FEE NO. TYPE OF FIXTURE FEE 3 WATER CLOSETS "" FORCED-AIR/GRAVITY TYPE FURNACE 6.00 BASINS o' FLOOR/SUSPENDED FURNACE 6.00 '4 BATHTUBS 402 BOILER/COMPRESSOR 6.00 L) SHOWERS U REPAIR/ALTERATION 6.00 �? WATER HEATERS 4"'� REFRIGERATION COMPRESSOR SYSTEM 6.00 Z AUTO.WASHER 4" AIR HANDLING UNITS 7.50 SINKS HEAT-PUMPS 6.00 u FLOOR DRAINS EACH GAS PIPING SYS.2.00 PER OUTLET Q DRINKING FOUNTAINS U S VENT.FAN SYS.3.00 PER UNIT C�J Cj LAUNDRYTRAYS Ci WOODSTOVES 5.00 C� CONNECT TO CITY SEWER WOOD FURNACE 5.00 DISHWASHER O DISPOSAL C) URINALS PERMIT BASIC FEE 3.00 PERMIT BASIC FEE 10.00 TOTAL #?,3" TOTAL SPECIAL CONDITIONS: NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER WORK IS COMMENCED. OWNERS AFFIDAVIT: I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF CONTRACTORS AFFIDAVIT: I CERTIFY THAT 1 AM A CURRENTLY REGISTERED THE CONTRACT OR REGISTRATION LAW RCW 18.27, AND AM AWARE OF THE MASON CONTRACTOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE ORDINANCE COUNTY ORDINANCE REQUIREMENTS FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL REQUIREMENTS REGULATING THE WORK FOR WHICH THIS PERMIT IS ISSUED AND ALL WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WORK DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING DEPARTMENT. X OWNER DATE ?—ZR -ekl-1 X By 4," DATE Q FOR OFFICE USE ONLY APPLICATION ACCEPTED BY PLAtjSCHECKBY BUILDING GROUP APPROVED FOR ISSUANCE PERMIT VALIDATION �I BY �( � CASH CK MO PREPARED BY: FOSTER AND WILLIAMS ASSOCIATES, P.S. , ARCHITECTS ANALYST: G. Foster PROJECT: Long Duplex PROJECT NO. : 8803 DATE: 8/3/88 INTENT: Washington State Energy Code Conformance. NOTE: THIS BUILDING WAS NOT DESIGNED BY FOSTER AND WILLIAMS ASSOCIATES. THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR STRUCTURAL INTEGRITY, NOR CODE COMPLIANCE BEYOND THIS ENERGY EVALUATION. ------ --------------------- SYSTEMS INCLUDED IN THIS PROJECT -- ------------------------------ FLOOR 1 (500 S. F. ) 2x8 JSTS. , R-19 INS. , 5/8 CDX, 1/2 P. B. , VINYL FLOOR 2 (1300 S. F. ) 2x8 JSTS. , R-19 INS. , 5/8 CDX, 1/2 P.B. , CARPET FLOOR 3 (0 S. F. ) ROOF 1 (1800 S.F. ) 2x4 TRUSS, R-38 INS. , 5/8 G.W.B. ROOF 2 (0 S. F. ) ROOF 3 (0 S. F. ) WALL 1 (1650 S. F. ) 2x6 STUDS, R-19 INS., 5/8 T-111, 1/2 G.W. B. WALL 2 (0 S.F. ) WALL 3 (0 S.F. ) SKYLIGHT 1 : (0 S. F. ) SKYLIGHT 2: (0 S. F. ) SKYLIGHT 3: (0 S.F. ) WINDOW 1 : (245 S. F. ) U VALUE= 0.6 WINDOW 2: (0 S. F. ) WINDOW 3: (0 S. F. ) HEAT TYPE: ELECTRIC RESISTANCE HEATING ZONE: 1 BUILDING TYPE: RESIDENTIAL �� OUTSIDE WINTER DESIGN TEEMPERATURE WINDOWS = n67 OF GROSS FLOOR AREA HEAT LOSS CALCULATION AND HEATING SYSTEM SIZE Long Duplex COMPONENT AREA U VALUE DELTA T HEAT LOSS (Q=U A T) ------------------------------------------------------------------------- FLOOR 1 CAVITY 470 0.045 47 989. 3 FLOOR 1 FRAMING 30 0. 081 47 113.8 FLOOR 2 CAVITY 1222 0.041 47 2357. 7 FLOOR 2 FRAMING 78 0.069 47 254.2 FLOOR 3 CAVITY 0 0.000 47 0. 0 FLOOR 3 FRAMING 0 0.000 47 0.0 ROOF 1 CAVITY 1692 0.025 47 1999. 1 ROOF 1 FRAMING 108 0. 162 47 824.0 ROOF 2 CAVITY 0 0.000 47 0.0 ROOF 2 FRAMING 0 0.000 47 0.0 ROOF 3 CAVITY 0 0.000 47 0.0 ROOF 3 FRAMING 0 0.000 47 0.0 WALL 1 CAVITY 1130 0.047 47 2518. 7 WALL 1 FRAMING 199 0. 112 47 1045. 7 WALL 2 CAVITY 0 0.000 47 0.0 WALL 2 FRAMING 0 0.000 47 0.0 WALL 3 CAVITY 0 0.000 47 0.0 WALL 3 FRAMING 0 0.000 47 0.0 WINDOW 1 245 0. 600 47 6909. 0 WINDOW 2 0 0.600 47 0.0 WINDOW 3 0 0. 600 47 0.0 DOOR 1 36 0.480 47 812.2 DOOR 2 40 0.080 47 150.4 DOOR 3 0 0.480 47 0.0 SKYLIGHT 1 0 0. 600 47 0. 0 SKYLIGHT 2 0 0.600 47 0.0 SKYLIGHT 3 0 0. 600 47 0. 0 INFILTRATION =1. 1xVxT 47 10262. 5 ( RATE =1.0 FOR DOORS AND 0. 5 FOR WINDOWS) SLAB AREA 0 @ 2 BTU/SF 47 0.0 SLAB EDGE 0 @ 11 BTU/SF 47 0.0 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 OTHER HEAT LOSS 47 MISC. HEAT GAIN(PEOPLE.APPLIANCES.ETC. ) 47 0.0 OTHER HEAT GAIN 47 OTHER HEAT GAIN 47 OTHER HEAT GAIN 47 ------------------------------------------------------------------------- TOTAL HEAT LOSS 28236. 5 MAXIMUM HEATING SYSTEM SIZE @ 150%: ELECTRIC RESISTANCE: 12.4 KW OTHER: 42355 BTUH NOTES: 1 . WINDOW CRACK ESTIMATED AT 1 L.F./S. F. 2. DOOR INFILTRATION @ 1 CFM/S. F. i RESIDENTIAL COMPONENT COMPARISON Long Duplex ALLOWED AREA GR.AREA U VALUE Ux ACTUAL AREA GR.AREA U VAL. Ux RATIO ALLOWED RATIO RATIO ACTUAL RATIO ----------------------------------------------- ---------------------------------------- 22 FLOOR 1 500 0.095 0.055 0.005 22 FLOOR 1 500 0.095 0.047 0.004 FLOOR 2 1300 0. 248 0. 055 0. 014 FLOOR 2 1300 0. 248 0.043 0.011 FLOOR 3 0 0.000 0.055 0.000 FLOOR 3 0 0.000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 23 ROOF 1 1800 0. 343 0.026 0. 009 23 ROOF 1 1800 0. 343 0.033 0.011 ROOF 2 0 0. 000 0. 026 0.000 ROOF 2 0 0.000 0.000 0.000 ROOF 3 0 0.000 0.026 0.000 ROOF 3 0 0. 000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 24 WALL 1 1650 0. 314 0. 144 0.045 24 WALL 1 1650 0.314 0. 147 0.046 WALL 2 0 0. 000 0. 144 0.000 WALL 2 0 0.000 0.000 0.000 WALL 3 0 0.000 0. 144 0.000 WALL 3 0 0.000 0.000 0.000 ----------------------------------------------- ---------------------------------------- 25 TOTAL 5250 Ut ALLOWED 0.073 25 TOTAL 5250 Ut ACTUAL 0.073 THIS BUILDING CONFORMS TO tIR 4 OF THE W ASH INGTON 7STATENERGY CODE Uo CALCULATIONS FOR FLOORS Long Duplex FLOOR 1 SYSTEM R VALUES R VALUES FLOOR 1 AREA AREA U Ux HEATING 3 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.92 0. 92 13 GROSS FLR. 500 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 9.06 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 500 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 78 0. 78 19 FRAMING 30 0.06 0.08 0.005 8 AIR FILM INSIDE 0. 92 0. 92 20 CAVITY 470 0. 94 0.04 0.042 9 OTHER a) 1/2 P.B. , 0.66 0.66 --------------------------------------------- 10 b) VINYL 0. 05 0.05 21 Uo=TOTAL LINES 14 TO 20 0.047 11 Rt=TOTAL LINES 1-10 12. 39 22. 33 12 U=1/R TOTAL 0. 081 0.045 - -------------- ----------- ----------------- FLOOR 2 SYSTEM R VALUES R VALUES FLOOR 2 AREA AREA U Ux HEATING 4 FRAMING CAVITY HEATING (S. F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0. 92 0.92 13 GROSS FLR. 1300 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 9. 06 XXXXX 16 OTHER 0 0.00 0. 00 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 1300 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 78 0. 78 19 FRAMING 78 0.06 0. 07 0.004 8 AIR FILM INSIDE 0. 92 0.92 20 CAVITY 1222 0. 94 0.04 0.039 9 OTHER a) 1/2 P.B. , 0.66 0. 66 --------------------------------------------- 10 b) CARPET 2.08 2.08 21 Uo=TOTAL LINES 14 TO 20 0.043 11 Rt=TOTAL LINES 1-10 14.42 24.36 12 U=1/R TOTAL 0.069 0.041 FLOOR 3 SYSTEM R VALUES R VALUES FLOOR 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS FLR. 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 OTHER 0 0.00 0.00 0.000 3 OUTER SHEATHING 0. 00 0.00 15 OTHER 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE FLR. 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0. 00 0.00 12 U=1/R TOTAL 0.000 0. 000 Uo CALCULATIONS FOR ROOF Long Duplex ROOF 1 SYSTEM R VALUES R VALUES ROOF 1 AREA AREA U Ux HEATING 1 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.61 0.61 13 GROSS ROOF 1800 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT 1 0 0.00 0. 60 0.000 3 OUTER SHEATHING 0.00 0.00 15 SKYLIGHT 2 0 0.00 0.60 0.000 4 FRAMING 4. 38 XXXXX 16 SCUPPER 0 0.00 0. 60 0.000 5 CAVITY a)INSULATION XXXX 38.00 17 OTHER 0 0.00 0.00 0. 000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 1800 XXXX XXXX XXXXX 7 INSIDE SURFACE 0. 56 0. 56 19 FRAMING 108 0.06 0. 16 0.010 8 AIR FILM INSIDE 0. 61 0. 61 20 CAVITY 1692 0. 94 0. 03 0.024 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.033 11 Rt=TOTAL LINES 1-10 6. 16 39. 78 12 U=1/R TOTAL 0. 162 0.025 ROOF 2 SYSTEM R VALUES R VALUES ROOF 2 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* 0 0.00 0.00 0.00 3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* 0 0.00 0.00 0.00 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0. 000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0. 000 0. 000 *INCLUDED IN ROOF 1 . ROOF 3 SYSTEM R VALUES R VALUES ROOF 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS ROOF 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 SKYLIGHT* 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 SCUPPER* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0. 00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE ROOF 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0. 000 0. 000 *INCLUDED IN ROOF 1. i Uo CALCULATIONS FOR WALLS Long Duplex WALL 1 SYSTEM R VALUES R VALUES WALL 1 AREA AREA U Ux HEATING 1 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO ----------------------------------------- --------------------------------------------- 1 AIR FILM OUTSIDE 0. 17 0. 17 13 GROSS WALL 1650 XXXX XXXX XXXXX 2 OUTER SURFACE 0. 78 0. 78 14 WINDOW 1 245 0. 15 0. 60 0.089 3 OUTER SHEATHING 0.00 0.00 15 WINDOW 2 0 0.00 0.60 0.000 4 FRAMING 6.88 XXXXX 16 WINDOW 3 0 0.00 0. 60 0.000 5 CAVITY a)INSULATION XXXX 19.00 17 DOOR 1 36 0.02 0.48 0.010 6 b)AIR SPACE XXXX 0.00 18 DOOR 2 40 0. 02 0. 08 0.002 7 INSIDE SURFACE 0.45 0.45 19 DOOR 3 0 0.00 0.48 0.000 8 AIR FILM INSIDE 0.68 0.68 20 OPAQUE WALL 1329 XXXX XXXX XXXXX 9 OTHER a) 0.00 0.00 21 FRAMING 199 0. 12 0. 11 0.013 10 b) 0.00 0.00 22 CAVITY 1130 0.68 0. 05 0. 032 11 Rt=TOTAL LINES 1-10 8. 96 21 .08 ----------------------------------------- 12 U=1/R TOTAL 0. 112 0.047 Uo=TOTAL LINES 14 TO 20 0. 147 ---------------------------------------------------------------------- -------------------------------------------------------------------------------------------- WALL 2 SYSTEM R VALUES R VALUES WALL 2 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 WINDOWS' 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 DOOR* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0. 00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0. 00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0. 000 0.000 *INCLUDED IN WALL 1. WALL 3 SYSTEM R VALUES R VALUES WALL 3 AREA AREA U Ux HEATING 0 FRAMING CAVITY HEATING (S.F. ) RATIO VALUE RATIO 1 AIR FILM OUTSIDE 0.00 0.00 13 GROSS WALL 0 XXXX XXXX XXXXX 2 OUTER SURFACE 0.00 0.00 14 WINDOW* 0 0.00 0.00 0.000 3 OUTER SHEATHING 0.00 0.00 15 DOOR* 0 0.00 0.00 0.000 4 FRAMING 0.00 XXXXX 16 OTHER 0 0.00 0.00 0.000 5 CAVITY a)INSULATION XXXX 0.00 17 OTHER 0 0.00 0.00 0.000 6 b)AIR SPACE XXXX 0.00 18 OPAQUE WALL 0 XXXX XXXX XXXXX 7 INSIDE SURFACE 0.00 0.00 19 FRAMING 0 0.00 0.00 0.000 8 AIR FILM INSIDE 0.00 0.00 20 CAVITY 0 0.00 0.00 0.000 9 OTHER a) 0.00 0.00 --------------------------------------------- 10 b) 0.00 0.00 21 Uo=TOTAL LINES 14 TO 20 0.000 11 Rt=TOTAL LINES 1-10 0.00 0.00 12 U=1/R TOTAL 0.000 0.000 *INCLUDED IN WALL 1. ------- --------------------------