Loading...
HomeMy WebLinkAboutBLD2023-01384 Mechanical - BLD Inspections - 9/18/2024 INSPECTION CARD Mason County 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# BLD2023-01384 PROJECT ADDRESS 8221 NE North Shore Rd Belfair,WA 98528 PARCEL# 222172300020 PROJECT DESCRIPTION Installation of new ductless heatpump system OWNER JOHN FERGUSON ADDRESS 330 S MADISON PHONE 206.200.6723 CONTRACTOR Dana's Heating Inc ADDRESS Po Box 4566 PHONE (360)876-7670 CONTRACTOR LICENSE DANASHIOOODZ LENDER INSPECTION. IN BATE Comments IN INSP BATE Comments FEMA Post(Final)Construction Mechanical/Plumbing Final q-18a ���C.' ��13'�� ��sosi l,'�-' QV�Oo!' ✓n�� 2IeJQ �n x MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncoun"a.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: &V po;d"®5 3E-q ADDRESS/LOCATION: '9V N6 A)044 wort_ Rd FINDINGS: SWD 1brur16Na-4-no,4 Q �msoAro tJ,,VTYW A,Gap Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. is OK to Date: ❑ Please contact our office regarding possible Department: $C structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2023-01384 MECHANICAL - RESIDENTIAL PROJECT DESCRIPTION: INSTALLATION OF NEW DUCTLESS ISSUED: 02/27/2024 HEATPUMP SYSTEM SITE ADDRESS: 8221 NE NORTH SHORE RD BELFAIR EXPIRES: 08/12512024 PARCEL: 222172300020 APPLICANT: JOHN FERGUSON OWNER: JOHN FERGUSON 330 S MADISON 330 S MADISON MONROE,WA 98272 MONROE,WA 98272 206.200.6723 GENERAL CONTRACTOR'S LICENSE: Dana's Heating Inc License: DANASH1000DZ Po Box 4566 Expires: 08/23/2025 BREMERTON,WA 98312 (360)876-7670 FEES: Paid Due Technology Flat Convenience $5.00 $0.00 Fee Mechanical Fees $19.00 $0.00 State Fee-Residential $6.50 $0.00 Final Inspection $80.00 $0.00 Mechanical Base Fee $30.00 $0.00 Totals : $140.50 $0.00 FIXTURES (3xt Mechanical Fixtures 1.0000 Ductless Heat Pump REQUIRED INSPECTIONS FEMA Post(Final) Construction Elevation Certificate Mechanical/Plumbing Final Inspection compliance ....... ....... ....... ....... ....._ ....... ....... ....... ....... ....... ....... ....... ....... _... ....... ....... ...... ...... ....... ....... ....... ....... ....... ....... ...... ----------------------------------------------------- Printed by:Nikita Huckabey on:04/03/2024 11:20 AM Page 1 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. _M....,;_ Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MECHANICAL - RESIDENTIAL BLD2023-01384 CONDITIONS * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be grantedw * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished.Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360 rc586.1044/800.422.5623 www.orcaa.org * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. _____________m_,_______________________.__.-------.----_______.._______._______._. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law._ _._. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections,changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. ___________________________________________________________.__________..._.__________. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County-- 4'28 and 14µ1--1 ____ ____ __ ______________________________________________________________. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification^ Any non-approved change of use or occupancy would result in permit revocation. '______________________. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed^ v w^^Y _ _ * Exterior unit must be elevated to above the Base Flood Elevation. ------------------------------------___________________________________________________________________________. Printed by:Nikita Huckabey on:04/03/2024 11:20 AM Page 2 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MECHANICAL - RESIDENTIAL BLD2O23-01384 * This property has been identified in a FEMA(AE) Flood Hazard Area. SUBSTANTIAL IMPROVEMENT as defined in the 2018 International Building Code is any repair,reconstruction, rehabilitation, alteration, addition or other improvement of a building or structure,the cost of which equals or exceeds 50 percent of the market value of the structure BEFORE the improvement or repair is started. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed.The term does not, however, include either: 1.Any project for improvement of a building to correct existing health, sanitary or safety code violations identified by the building and that are the minimum necessary to assure safe living conditions. 2,Any alteration of a historic structure provided that the alteration will not preclude the structure's continued designation as a historic structure. When Substantial Development has,been determined future work including such items as change of use, additions, alterations, and repairs are subject to the requirements of the 2018 International Existing Building Code and 2018 International Building Code Section 1612. Mason County Flood Prevention Ordinance definition (MCC 14.22.040): "Substantial improvement"means any repair,reconstruction, or improvement of a structure,taking place DURING A TEN- YEAR PERIOD, in which the cumulative cost equals or exceeds fifty percent of the market value of the structure either: (1) Before the improvement or repair is started,or (2) If the structure has been damaged and is being restored before the damage occurred. For this definition"substantial improvement"is considered to occur when the first alteration of any wall,ceiling,floor, or other structural part of the building commences,whether that alteration affects the external dimensions of the structure. This term includes structures which have incurred"repetitive loss"or"substantial damage" regardless of the actual amount of repair work performed. The term does not, however, include either: (1)Any project for improvement of a structure to comply with existing state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official, and which was in existence prior to the damage event or improvement,and which are solely necessary to assure safe living conditions, or (2)Any alteration of a structure listed on the National Register of Historic Places or a State Inventory of Historic Places. All future work will be evaluated at the time and by scope and value. __________________.___._____-._.__.._____----------.__....--------...--------..._,___........ . * Compliance is required for protection of utility systems(interior and exterior of the structure). Flood proofing can be achieved using several measures including elevation, relocation, component protection, or other measures that provide partial protection. Different approaches can be used to improve flood damage resis-stance. This is key in areas of repetitive, low-level flooding. The principles of these measures apply with two key methods: elevation and component protection and can be accomplished at elevations higher than the elevation required greater than the Base flood elevation or two feet above the highest adjacent grade. See flood survey performed prior to the clearing, grading or excavation for elevations. ________________________________________________________________________________________. Printed by:Nikita Huckabey on:04/03/2024 11:20 AM Page 3 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MECHANICAL - RESIDENTIAL BLD2023-01384 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: Printed by:Nikita Huckabey on:04/03/2024 11:20 AM Page 4 of 4 Mason County Permit Center use: MASON COUNTY' COMMUNITY SERVICES__..... FLD1U!3 Building,Planning,Environmental Health Community Health 1 t,, n 615 NY,Alder Street—Bldg,,8,Shelton,WA 98584 Date RCVd. 11• �{/ • L�j Phone;(360)427-9670 Ext 352♦Fax:(360)427-7798 Fee: $300.00 No fee if w/other permits FDPO Development Permilt A00licabon 'Applicant: Contractor: lip C. _Wdlinc Address;: Malhng Adtlress:: _. 33 o g ifY a�l-i sin .... .. :F��. S(o 6 City. State. Zlp..: r City, State .Zip: _ Phone:..... Phone: (20b12 00-God 23 f3�d 5 3 fo �2'7 Email: ... _. _ _ Email: . . tb Parcel Number: PropprtY Address.` 22-t�23 0 op2p 8Z2( N 1 c)r4t\ Show- Rd.. I understand I am making application for a permit to develop in a designated flood hazard area.The undersigned agrees that all such work shall be done in accordance with the requirements of the County Flood Damage Prevention Ordinance,building codes and all other applicable Local, State and Federal regulations. This application does not create liability on the part of the County or any officer or employee thereof for any flood damage that results from reliance on this application or any administrative decision made lawfully thereunder: Applicants Signature:.`' Date: 11-/!o Official Use: A Descriptiono€`Work:'(completefor:'allwrk) 1. Proposed Development Description: ❑ New building/Addition ❑ Manufactured home ❑ Fill/grade ❑ Other: .. .... ... .. .. . ❑ Commercial (see section D) �1 Remodel/repair to existing building (see section C) 2. The parcel has been identified in the following Flood Hazard'Area: ❑ A ,�AE ❑ AO ❑ VE 3. Are any other Federal, State or local permits required? Must attach copies of permits. ❑ Yes ❑ No If yes, list type: 4. Is the proposed development in an identified floodway? ❑Yes No 5. If yes to#4, a No Rise Certification must be attached, ❑Yes ❑ No i B. Complete for New Structures and Building Sites: 1. A FEMA Elevation Certificate is required, must be completed by a Washington State licensed Surveyor. Must attach a copy of certificate. 2. Base Flood Elevation at the building site: feet NAVD 88 3. Required lowest floor elevation (including basement floor): feet NAVD88 4. In flood hazard areas without a base flood elevation (BFE), what is the highest adjacent Grade? (HAG) Structure must be a minimum of two (2) feet above the HAG. The required finish floor height is C. Complete for Alterations, Additions, or Improvements to Existing Structures: ******(See attached Substantial Improvement & Substantial Repair)******* Q 1. What is the estimated market value of the existing structure? $ .b49 2. What is the cost/valuation of the proposed construction? $ `J Percentage 4*V 1 3. If the cost or valuation of the proposed construction equals or exceeds 50 percent of the market value of the structure, then the substantial improvement/repair provisions shall apply. Is the proposed work a substantial repair/improvement ❑ Yes No D. Complete for Non-Residential Floodproofed Construction: 1. Type of floodproofing method: 2. The required floodproofing elevation is: feet NAVD88 3. Floodproofing certification by a registered engineer is attached: ❑ Yes ❑ No E. Complete for Subdivisions and Planned Unit Developments: 1. Will the subdivision or other development contain 50 lots or 5 acres? ❑ Yes ❑ No 2. If yes, does the plat or proposal clearly identify base flood elevations? ❑ Yes ❑ No 3. Are the 100 Year Floodplain and Floodway delineated on the site plan? ❑ Yes ❑ No Admi,nistrative 1. APPROVED: DENIED: statement attached 2. Elevation Certificate attached: ❑ Yes *No 3. As-built lowest floor elevation: feet NAVD88 Comments/Conditions: f 6 ill IaJ 0O Vim✓ Or 1 � Mason County Flood Damage Prevention Ordinance #41-17 & International ffuilding Codes g � , Patti McLean Parcel Details ^ Mason County Assessor 22217-23-00020/2024 411 N 5TH ST Active P O BOX J IIIIII IIIII IIIII IIIIL IIIII IIII II I III IIIII IIIII IIIII IIIII IIIII IIIII IIII IIII Shelton,WA 98584 360-427-9670 x491 3 0 0 0 0 +. :4. 2: 0 4 4. 3. `O Parcel Number: Roll Year: Type: Retired: Exempt: 22217-23-00020 2024 Active No No Assessment Type: Description Real Property Primary Owner Primary Situs: FERGUSON,JOHN 8221 NE NORTH SHORE RD BELFAIR Legal: TR 2 OF GOVT LOT 4*&TAX 539-C* AND TAX 1203-B* DOR: Secondary Land Code Map Number 18-Residential-All other 32 WF Total Acres Property Class Appraiser Initials 0.67000 TX Field Sheet FS O4403: District: Neighborhood 0258-Tax District 0258 N14/AREA 4 SubDivision: Exemption Type/Level: Frozen Value: Category '24 New Const '24 Market '24 Assessed r Estimated Exemption Amount: 0 Land: 0 351,125 351,125 NonSeniorAmount: 0 Impr: 0 362,715 362,715 Exemption Amount: 0 Perm Crop: 0 0 0 Remaining Taxable Value: 713,840 Total 'o 713,840 713 840' � e • Land a Land Land � O ❑x 252,189 + 252,189 Economic,Adjustment'; « ,x>.,; A4 N1,4{WF)UPDATEOR2024, 98 934-; Stnyle Faintly Resrdence 349 z13 Single-family Residence 0 0 323,345 + 1 323,345 Economic Aijustment'" A4 N14(1NF)UPDATE FOR 2024 ,`. 0,. > 0 e .°%u 25,8,6 8' Site Improvements ® ® 13 500' Lump Sum Septic System 0 O 8,500 + 8,500 Lump UM"" , Water:System e h ,. " O 0 Y` h 5 g.. 300002 ParcelDetails www.terrascan.com Parcel Details Printed on 12/5/2023 1:21:04 PM Page 1 of 3 PO Box 4566 ." 2181 Chico Way NW Dam Bremerton,WA 98312 Xr 360-876-7670 HEATING& COOLING,INC.,. 11VVOICE Name John Ferguson Date 11/17/2023 _,_:.__....... ..._....w....,..,....,,... ......: .....:......., .........__ _ ...�.._..... .Address 8221 NE N Shore Rd Invoice No. i43958 _.................... .. ';City Beftir,WA Customer No 50866 ... _...,.,.. Phone 206-200-6723 TOTAL r Daikin Multi Port Heat pump 4MXL36WMVJU9 ; Daikin Wall Mount FTXSI8LVJU in Living Room with Wifi Module install on o unit44 Daikin Wall Mount FTXS18LVJU Upstairs Main Room AHRI#210722666 SEER2 20.00 EER211.70 HSPF2 9.00 2 qty remote controls Line set with UV Cover Line Hide with Condensate drain Communication Wire < x Electrical circuit and Breaker with GFi Outlet per code T ' Whip&Disconnect with Fuses o i Power Surge Protector Of��E a Pad,Gravel and Risers Fire off to Manufacture specs r 12 Years Parts and Labor on systemq 1st year maintenance Included < Labor and Materials Permits and Paperwork for rebate �s . iSubTotal $ 1 d6fi Ot) Labor warranties require an annual maintenance by Dana's Heating Inc. 0 1=inanced Sales Tax 10 •'. Check TOTAL $? t340, 01` Credit Card Billing Down Payment 541 p . Check#1020 Final Payment wit13, Check#1021 i TOTAL OWED .: Thank you"for yourbusmess � L eavea r revew yip and help usgrow! "Large enough to serve you, Small enough to care" . — .