BLD2023-01392 SFR - BLD Inspections - 9/23/2024
MASON COUNTY/ �+ » T 615 W.Alder St.Bldg 8,SHELTON,WA 98584 COMMUNITY 1 SERVICES SHELTON:360-427-9670,EXT 352 BELFAIR:360-275-4467,EXT 352 Building,Planning,Envlronmental Health,Community Neanh ELMA:360-482-5269,EXT 352 www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY'" To schedule an inspection call or visit http:/Iwww.co.mason.wa.usicommunity-services/bid-inspectioq.ph Permit Number BLD2023-01392 Date Issued 12/27/2023 Issued By Project NEW SFR W/ATTACHED GARAGE(HILINE) Site Address 40 E Snowcrest Ln Applicant GUSTAFSON KATRINA Contractor HILINE HOMES Contractor Phone 1.253.840.1849 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type NEW SINGLE FAMILY RESIDENCE Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. `*THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.— PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks /O ZTICSSlab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls 2. 2- Other Rough-In Groundwork Plumbing Framing Z Groundwork Mechanical *.; Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor 2Iq ZLI J Other Insulation Slab Ceiling (� /Z y'c( Floor Vaulted Ceiling Walls 4 Z4 —TTJ, Vapor Barrier (� l!Z/ZY Other Wallboard Interior Wall Brace Panels Fire Walls Nailing_ Other Final Building 9 Z3/Z'q Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other ///0(2� ls�Go r}55�a.a..l' llts ix�n Pit'" V,nd�r�arr �i.+t Z 1�l2W 'C� S�r4-r4- st.�wwbt 1 2-1 Z4 rzu 516_ Su-4W r 1A In 31;,C-t/zK �� F%NrwA Ta.t ( G (1Zlz&( J72- See.+ MASON COUNTY 360427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncoun"a.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: ZLb 2-023 -di 3gZ ADDRESS/LOC ION: qO £ sft,4, 6"1- Z-,J si"W n FINDINGS• �� Las-loll ) Na�a�rs e,, .�wt �q�.�is t4Cc.�ss mA�n#1�,is CZ " P"" +0 (8 OC.2 ,GlcGsw� �� 1 ' 2 L3�b sg 9-���� Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. FO Make corrections, items will be checked on the next inspection. OK to ga A(nc"-% Date: 7- 1-7 )1-9 ❑ Please contact our office regarding possible Department: SLD structural damage incurred by recent Inspector: .!'G� "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY DEVELOPMENT 360-482-5269 Elma ext.352 -<; Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncoun"a.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 3LV2m.3-O 1 SqZ ADDRESS/LOCATIONs y0 C. FINDINGS Jtr (1,,.Al i CL, it `� � � S � a�-c.r Lr� �✓,n._..1� o In Oan.�.l EaT, A.r,._ glw�l�A�e_.l�a. `moo No4- wr LQ 3 ",s — ►►►� � Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. [� Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: y ❑ Please contact our office regarding possible Department: 45LD structural damage incurred by recent Inspector: S(p "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 0 � 2 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY DEVELOPMENT 3360-484467 5269 Elma ext.352 N Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncoun"a.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: 13L02oz3 - o t S'I Z- ADDRESS/LOCATION: y v E ".0 81�i�vn FINDINGS: ti Cu j 1kA A �u g v�nart�d �%► 3(6 c1c 1 - ►T S n^ aul UeAA �L W�1 ' ='�e:c,,�-iors - S.e.�_ a1r..cLc._ �1.�.,rk.S on t(-er,i,4.,1►N �- on ?Sc- 2 q Cvvyv.n,�- s-. 51AST-4 30 Do,,����s-k,,,� AZ-Ss,b►�, �4.�s� ►9�,lcl . 5 931 ��b C— w S► .0 lnS 2 L- '- '] IZ SS 31 ��•,a�_ Cvref Ats. Stc_ AA i1) �I�w�- 'L off' 1(ass C�n� �•�`/ Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any-further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 ' ZtrPr 2- MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY DEVELOPMENT 3360-484467 5269 Elma ext.352 Building,Planning,Fire Marshal 615 W.Alder St.Bldg.8 - Shelton,WA 98584 www.masoncountywa.gov CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: L6 za z3- o i3 42- ADDRESS/LOCAT N: G FINDINGS•. _ 1;K4r,-U j J�1 ASS��w '��e ra,d 3 r,,c,lu, ay� i rvs s Awl sk i4s�� Caic,4r1 ►�, F2..�l Din 1�ryss Eyw.ntA�,wt �.�wtib�ln[, Sy.oalr dk_ Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been 'inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances.. Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ® OK to l7 J`c�tin L u,M Io v� Date: ❑ Please contact our office regarding possible Department: 131,!) structural damage incurred by recent Inspector: 0. "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS. TAG MCC14.12 . f INSPECTION RESULTS Pagel MASON COUNTY Department of Community Development _ r COMMUNITY SERVICES 615 W Alder St,Shelton,WA 98584 (360)427-9670 Application# BLD2023-01392 Application NEW SINGLE FAMILY RESIDENCE Application# BLD2023-01392 Parcel# 221337690032 Site Address 40 E Snowcrest Ln Shelton,WA 98584 W 6-12-24-JQ ZINSTALL PERM OR TEMP GROUND COVER FOR EROSION CONTROL AROUND PERIMETER OF DWELLING GRADE MUST BE SLOPED AWAY FROM FOUNDATION(6"FOR EVERY 10')EAST SIDE AND NORTH SIDE FILL IN AROUND FOUNDATION INSTALL ADDRESS ON STRUCTURE THAT IS VIABLE FROM THEN STREET Joshua Quarders BLD-FINAL INSPECTION TEMP-OCC ,�4'`.INSTALL TOE KICKS ON TEMP STAIRS AR FRONT ENTRY ,eINSTALL 90 DEGREE DOWN TURN ON T&P DRAIN CAULK EXTERIOR ENVELOPE PENITRATIONS AT COAX CABLE BY MAIN PANEL NO LIFE SAFTEY ISSUES 180 TEMP OCCUPANCY GRANTED CALL FOR REINSPECTIONWHEN CORRECTIONS ARE MADE BEFORE PROCEEDING WITH ANY FURTHER WORK. GENERAL OBSERVATIONS AWAITING INSPECTION .,�__.,._ .�. ....,_ Description� ��� .,.�.,...,.,..�.,....�.._.-.�, _ ..�...�__ Status � ,... Status Date Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2023-01392 NEW SINGLE FAMILY RESIDENCE PROJECT DESCRIPTION: NEW SFR W/ATTACHED GARAGE (HILINE) ISSUED: 12/27/2023 SITE ADDRESS: 40 E SNOWCREST LN SHELTON EXPIRES: 06/24/2024 PARCEL: 221337690032 APPLICANT: GUSTAFSON KATRINA OWNER: GUSTAFSON KATRINA 20 E SNOWCREST.LN 20 E SNOWCREST LN SHELTON,WA 98584 SHELTON,WA 98584 1.860.463.6979 GENERAL CONTRACTOR'S LICENSE: HILINE HOMES License: HILINH"983BD 11306 62ND AVE EPUYALLUP,WA 98373 Expires: 11/08/2025 1.253.840.1849 VALUATIONS: FEES: Paid Due Covered Deck/Carport 80.00 $1,760.00 Building Permit Fee $1,912.40 $0.00 R-3 VB Residential, one- 1200.00 $199,296.00 Technology Surcharge $67.93 $0.00 and two-family Plan Check Fee $1,243.06 $0.00 U VB Utility, miscellaneous 484.00 $32,176.32 State Fee-Residential $6.50 $0.00 Planning Review Fee $240.00 $0.00 Plumbing Base Fee $25.00 $0.00 Plumbing Fees $113.00 $0.00 Building Plan Review/Change of $130.00 $0.00 Use-Onsite Sewage Mechanical Fees $73.00 $0.00 Mechanical Base Fee $30.00 $0.00 Total: $233,232.32 Totals : $3,840.89 $0.00 FIXTURES (3ty Mechanical Fixtures (3ty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Bath Tubs 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Clothes Washers 1.0000 Ductless Heat Pump 1.0000 Number of Dishwashers Printed by:Amber Selby on:12/27/2023 02:06 PM Page 1 of 7 � a � Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2023-01392 (3ty Mechanical Fixtures Qty Plumbing Fixtures 3.0000 Spot Vent Fan(s) 1.0000 Number of Kitchen Sinks 1.0000 Number of Water Heaters and or Vent 2.0000 Number of Hose Bibs 2.0000 Bathroom Sink 2.0000 Number of Showers 2.0000 Number of Toilets REQUIRED INSPECTIONS Setback Inspection Rough- Plumbing Inspection -----------------------------------------------.---__ Footing Inspection Mechanical Inspection --------------------------------- .--_-._----.--___ Foundation Wall-Pre-Pour Inspection Insulation Inspection ------------------. ---------------------------------- - --_ _ - -_ _.-- - _.- - _ _ _ _ Underfloor Inspection Connection has been verified by Health or Utilities ----------------------------------------------------- __- Shearwall Inspection BLD-Final Inspection --------------------------------------e__,._ ._______. _ Framing Inspection CONDITIONS Printed by:Amber Selby on:12/27/2023 02:06 PM Page 2 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2023-01392 Installation of heating equipment in a single-family residence shall meet the requirements of the current WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC,Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts,air handlers,filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts.When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit"or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and.all ducts are located within the heated space. * 'Adpted Wshington State Energy Code Compliance has been approved as follows: _w _ .%_ _._. _ . o a Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C,Window(Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. 4 DHP with zonal electric resistance per option 3.4 1.3 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U =0.28, Floor R-38, Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% 2.1 Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour. maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a high efficiency fan(s)(maximum 0.35 watts/cfm), not interlocked with the furnace fan (if present).Ventilation systems using a furnace including an ECM motor are allowed if they are controlled to operate at low speed in ventilation only mode. 3.4 Ductless mini-split heat pump system,zonal control: In homes where the primary space heating system is zonal electric heating,a ductless mini-split heat pump system with a minimum HSPF of 10.0 shall be installed and provide heating to the largest zone of the housing unit. Printed by:Amber Selby on:12/27/2023 02:06 PM Page 3 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2023-01392 * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site,then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. " All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. Concrete used for basement walls,foundation walls, exterior walls; porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). " Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner,agent for the owner or a registered contractor according to WA state law. Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. ...........................,................:...............,... * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by-Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED",they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. " M Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. .. ......................._......._............._.._.._.._......____.:.................................... .... * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. -------------___..--------._.__..-------------------------__________.____-. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. ...................... .....................w_.._....._...................................................... . All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration.The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. Printed by:Amber Selby on:12/27/2023 02:06 PM Page 4 of 7 t 1 Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2023-01392 * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries(L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. -_-_...---- ----------- ---------------- ---------- ----------------------- -------------------------- -- * Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance contact the Mason County Public Works Department prior to construction at Ext 450 - -- ---------- ----- * A permanent------------------ --- -------certificate, completed by--------- ----------------- ------- ------ -- -----the builder or registered design professional, shall be posted-on a wall in the s-pace where the furnace is.located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof,walls,foundation (slab, basement wall,crawlspace wall and/or floor), and ducts outside the conditioned spaces; U-factors for fenestration; and the solar heat gain coefficient(SHGC)of fenestration.Where there is more than one value for each component, the certificate shall list the value covering the largest area.The certificate shall list the type and efficiency of heating,cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Chapter 4, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with WSEC Section R402.4.1.2. - The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate"and are available in '/<or'h sheets. ............................................................................................................. * When parcel development requires direct access to county road(s), a Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For any construction which is proposed to be located within 25;of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. For more information contact Public Works, at(360)427-9670, ext.450 or 100 W Public Works Dr. Shelton.The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. __ _ _ _______________________________________________________________________________,. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. ........... * All property lines shall be clearly identified at the time of foundation inspection. -------------------------------------------------.__..___.__-_---_--___-__-----..-_-----------------___ .---_ * The foundation/footing must be placed on undisturbed,firm-native soil. Proper frost depth shall be observed below grade in undisturbed soils. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. Printed by:Amber Selby on:12/27/2023 02:06 PM Page 5 of 7 Mason County Mason County - Division of Community Development 615 W.Alder St. z - , Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE FAMILY RESIDENCE BLD2O23-01392 * A minimum of 90 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECCIWSEC Section R404.1. - - ------------------------------- -------------- --------------------__------------- * The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'.from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. ----- _. ............ .... ... .----.._--- ---_.... -_--.---. .. ..--- __----__._ ----- * OWNER/BUILDER acknowledges.submission. ...of inaccurate informatio.n may result.in.a stop.work order or_.permit. revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. ..............................................................................................................- * The use, handling and storage of hazardous materials or flammable and combustible liquids in excess of 10 gallons is not allowed without the approval of the Mason County Fire Marshal. -------------------------------------------------------------- ......................................... * A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. .Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. ------------------------- ---------------------.-----------------------------------------------,------ * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * WIND LOADS-Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. Printed by:Amber Selby on:12/27/2023 02:06 PM Page 6 of 7 o Mason County Mason County - Division of Community Development 615 W.Alder St. Building 8 Shelton,WA 98584 360-427-9670 ext 352 www.masoncountywa.gov NEW SINGLE.FAMILY RESIDENCE BLD2023-01392 * Planning Setbacks Front(North): 25' Sides:20' Rear: 20' *all.setbacks measured from the farthest projection of the building *subject to EH setbacks *all changes are subject to review and approval * All structures must meet setback requirements.This includes RV covers and carports. * Applicant/Owner assumes all responsibility if On-site Sewage Components are encumbered. A.) Drainfield/Reserve requires a 1 Oft setback from all footing/foundations. B.)Septic tank(s) requires 5ft setback from all footing/foundations. C.)No foundation/Perimeter Drains within 30ft, down gradient of Drainfield/Reserve area. D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within 50ft, down gradient of Drainfield/Reserve area. I hereby certify that I have r d and examined thi application and know the same to be true and correct. All provisions of Laws an O dinances governi this type of work will be complied with whether specified heI not. a ranting of a er oes not presume to give authority to violate or cancel the provisiony of er state/lo I I re ting construction or the performance of construction. Issued y: Contrac or or Authorized Agent: Date: Printed by:Amber Selby on:12/27/2023 02:06 PM Page 7 of 7 W11C 3 IVA[ U Mud Bay•Geotechnical Services, LLC 1001 Cooper Point Road SW, STE 140 PMB 108[Olympia,WA 985021 W0.481.97841 CHeathman@MudBayGeotech.com October 25, 2023 Subject: Slope Erosion &Stability Reconnaissance 40 E Snowcrest Ln, Shelton, WA 98584 Parcel#22133-76-90032 Dear Trina Gustafson, Per your request we completed a slope erosion and stability assessment for Parcel #22133-76-. 90032, located. in Shelton, Washington. The parcel of discussion comprises an area of. approximately.1.24 acres and is accessed via the southern side bf E Snowcrest Lane. Presently, the site is undeveloped with.plans to..construct.a new single-family residence-with attached garage. The topography.of the site'and surrounding region is gently west sloping. Previous grading activities on-site.have resulted in the creation-of a flat development pad area along the eastern half of the parcel with small, slope sections positioned along the eastern and western margins of the flat pad. The flattened pad is the.area of proposed construction; downslope to the west is the proposed septic drain field. The small section of slope between the proposed home location and septic area spans an elevation change of roughly 4-5 feet at:a slope of approximately 1.5H:1V. This western slope section features established vegetation and 'did not display indications of slope movement or erosion. It is our understanding that the.grading activities on- site occurred between 12-15 years.ago. Since the grading activities, no-significant changes to the slope cuts have occurred. The primary focus for our site visit on October 24, 2023 was to assess the condition of the hillside , on the upslope,eastern side of the proposed development pad.The slope.of discussion is situated approximately 20 feet from the proposed home footprint. The slope ranges in height, generally increasing in height moving southward. Along the northeastern corner of the property,:the slope catches the .grade of E Snowcrest Lane. Moving southward, the slope height increases to a maximum of roughly:10-12 feet.Within the taller slope sections, vegetation in the form of various native shrubbery,.Scotchbroom, and: sporadic trees exist. During our site investigation, the primary focus is a section of slope off the northeastern corner of the home where invasive vegetation species were removed approximately -one year ago. Following removal of -the Scotchbrbom vegetation, shallow erosion has been noted within this section of slope.:The slope area of concern measures approximately 8 feet in height at a slope of approximately.60%. The exposed soils within the slope cut were noted to consist of moist, gray-brown, silty sand with gravel (SM). The relative density was investigated using a 48-inch soil probe and found to be unyielding.We interpret the on-site sediment to consist of hardpan glacial till deposits, consistent with the mapped geology and soils for the site and surrounding region. No indications of groundwater seepage or rill and sheet erosion were observed within the slope section. The area above the slope was investigated and found to be unyielding with no ground cracking or sloughing noted. Trees growing within and above the slope of discussion were noted to be straight-trunked and vertical; no indications of progressive downslope movement or rotation of the trees were observed. Based on our assessment of the slope of concern, it is our opinion that the slope is composed of very dense, undisturbed glacial material and is of low risk of slope failure. The primary concern regarding the slope in its present state is shallow erosion and raveling of gravel clasts exposed at the surface of the slope face. In our opinion, the slope is situated a sufficient distance from the proposed home footprint and should not serve to impact the structure. A thin layer of colluvium (-2-4")was observed at the base of the slope cut and did not extend more than 12-24 inches from the slope face. In our opinion, improvements should be made to mitigate the shallow erosion observed at present. We recommend the following improvements: Jute, coir, or turf reinforcement mat should be placed on the surface of all exposed ground surfaces, pinned using 9-inch landscaping staples at a 16-inch spacing. The erosion condition adjacent to the structures should be monitored periodically for any signs of surface erosion, degradation, and shallow failures. If significant erosion or failures are observed,then those should be mitigated as soon as possible. Vegetation should be maintained where it currently exists on existing slopes where disturbance is not necessary as part of construction. Existing bare and disturbed soil areas should be planted immediately with grass and deep-rooted plants and native conifers to help reduce erosion potential. Where felling of trees is necessary, stumps should be left intact except for areas where they encroach on the footprint of structures. All exposed soil should be hydroseeded or planted with a mixture of native plants as soon as possible-after-grading-is-complete.-If-the-construction-is-not-completed-until-the-later-part-of-the summer or fall and winter months, then the areas should be left covered until the springtime growing season. Additional Information While on-site, several open test pits of 4-foot depth were encountered near the proposed drainfield. The soils within these test pits generally displayed soil types consistent with those observed in the slope cuts, indicating consistency of competent sediment across the entirety of the property. The sediment types on-site have been mapped by the WA DNR as Pleistocene continental glacial till across the entirety of the property and surrounding areas. The mapped geology is generally consistent with the sediment types observed on-site. No groundwater seepage or standing water were noted within the open pits or elsewhere on-site. No indications of poor drainage or shallow groundwater were observed while on-site. Furthermore, no indications of upland waterbodies or wetlands were observed while on-site nor during our review of available mapping resources. Please contact me.at your earliest convenience if you have any questions or would like to discuss any of the content of this report. Sincerely, Chris Heathman Mud Bay Geotechnical Services LLC. Rie�Q`dt}liry/� VIASrr� 10/25/2023 46365 Pl AL���` q ILI /;?(4 �V,SeA 'Vf,/S& 0 1 5C('2- ls�lt,'Y�r%'YJL bLA 2-02:15 Joshua"Quarders From: Taner Racca <tracca@hilinehomes.com> Sent: Thursday,April 4, 2024 9:54 AM To: Joshua Quarders Cc: Taner Racca Subject: FW: R81578267 - 3720301 - Hiline 1002-2465 Gustafson Attachments: R81680624.3720301.pdf Caution: EkternaI Email: arnngt:TN s email ginatbd frOn.outside bf,th e:Ma.sbh*C0jhtV1r' .............. Network': Do not click links,Or:open:attachments.!pn.Less..yo:u,re.c.ognlzej.th6!se d...er;:are:epecting:t,h...e. .......... qI .M p.!: acid kn6w' h t t i &.lfa� in �sen,a...$:yQ.W tqq:We,....s.... e.wh em'vou are as' .d AoVatidbte .. h ' incident in A-c.Cou,nt*an:d P -,: rt-t e. t. .' s. gypqr). assword 'DONOTDO'SO!I ns' tead reDo .......... ...... .......... See attached and below. Framer Will add the one brace by Monday. Taner Racca Hiline Homes LLC From: Matt Rogers<matt.rogers@ bid r.com> Sent:Thursday,April 4,2024 9:51 AM To:Taner Racca<tracca@hilinehomes.com> Subject: FW: R81578267-3720301-Hiline 1002-2465 Gustafson Engineering attached showing brace above ceiling line of vault. Matt Rogers Truss Sales-Components Woodland Truss 503-260-2019 V1 Builders Nk.4 Fir Source. From:Cody Clarke<cody.clarkepbldr.com> Sent:Thursday,April 4, 2024 9:45 AM To: Matt Rogers<matt.rogers P bid r.com>; Eli St.John<eli.stjohn@bldr.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson Hi Matt. Here is the gable brace moved. Bulde i " M" Cody Clarke 6i6 r* : Design Manager—Woodland,WA&Beaverton, OR Truss Fir.StSo' 'Uce 1930 Schurman Way Woodland,WA 98674 cody.clarke(a)BLDR.com C:503.969.1357 1 BLDR.com 1 r , OUTPERFORM T " ► 1 ' TOMORROW. From: Matt Rogers<matt.rogers@bldr.com> Sent:Wednesday,April 3,2024 7:54 AM To: Eli St.John<eli.stiohn@bldr.com>; Eric Ekstrom<eekstrom@mii.com>;Cody Clarke<cody.clarke@bldr.com> Cc: Mark Jurgewicz<miurgewicz@mii.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson Eric, could we simply shift the brace up a foot or two above the vaulted ceiling? Cb rt2SS n fype y amine 1002-24656uslafson 372M f+.4 GABLE 1 1 Jcb Ltefermca fcticrmD Buffleaa FratBaurce Truss,E39MM M,OR 87005 Run:8330 z 1an 12 3 Frint:8MG a Jan 12 2023 DJ sk lnd lQ:YnmQU2)(r1Ih-x6S5gGG6HJ S?4-6txdSaWmQi , 5 3Q{k l , 14-5_11 7, 00 - - - 34-&4 1-4.0 5 f}5 �5-11 4-5-11 6 15-&0 4tC5::: 5 6 INN r 5_00 FfT 4X5 II 4 7 ST4 52 ' 1 3 53 SF5 R k� 5 f 3ST 15 a # 1 7 8 wtTO 9 1 � 5 3%1(1 6 r � &4— 224 23 22 21 20 18 18 17 15 15 14 13 M8= 50= 3D-M — 3D-M Plate meets fXY�- [3 o-2-0 o-o-31.0:0-2-0.0-0-01[20:0-4-0,G-3-01,{34:0-0r 12,0-lA,[37 o-1-K -1-c] -- LOADING(pA SPACING- 2-0-0 CS1. DEFL in (loc) Vdafi Lid' TGLL 30.0 Plate Qip DOL 1-15 TO 0.34 Verku) -0.00 10 nlr go n-ni Sno1s=30 n Lumber DOL. 1.15 0G 0,15 Vert(GT) 0.00 10 nfr 120 Matt Rogers Truss Sales-Components Woodland Truss 503-26o-2019 0 Builux-H IS .d FirstSource,, From: Eli St.John<eli.stiohn@bldr.com> Sent:Tuesday,April 2,2024 4:25 PM 2 I N To: Eric Ekstrom <eekstromgmii.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@ bid r.co m> Subject:RE: R81578267-3720301-Hiline 1002-2465 Gustafson Layout attached. V' yy V "AP -A ear " 4v Iq 44. AV jj 3 From: Eli St.John Sent:Tuesday,April 2, 2024 10:16 AM To: 'Eric Ekstrom'<eekstrom@mii.com>; Cody Clarke<cody.clarke@ bid r.com>; Matt Rogers<matt.rogers@bldr.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson 4 pl Today 2.20 PM: <_- � � - y y rF WORK s g PUT AIA .. ." .� ..,.e.._K :Ed,.� ;--"-"-' H ,a a , ��� From: Eli St.John Sent:Tuesday,April 2,2024 10:14 AM To: Eric Ekstrom<eekstrom@mii.com>; Cody Clarke<codv.clarke@bldr.com>; Matt Rogers<matt.rogers@ bid r.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson BTU CHORD SCISSOR TRUSS A34 CLIP @ TWO LOCATIONS ae NOTCH TOP PLATES STRAP TOP PLATES FOR 4 c POST 1 SI IPSON MST 7' II II II 4x6 DF 2 POST TRUSS BRACING,TO, VAULTED CEILING BLOCKING FASTEN BOTTOM OF 4 —' ELT F2 POST T BOTTOM PLATE / 5 d NAILS 91 FRAMING-GABLE END-VAULTED CEIL BRAC 318 R _ E_0tf From: Eli St.John Sent: Monday,April 1,2024 10:40 AM 6 To: Eric Ekstrom <eekstrom@mii.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@bldr.com> Subject: RE: R81578267-3720301- Hiline 1002-2465 Gustafson Eric,can you see a reason anything in this truss needs to be structural when there's continuous bearing on the gable truss? And the either way the sheathing should account for the brace. Non structural ledgers aren't meant to be braced to. Framers are asking us for this. From: Eli St.John Sent: Friday, March 29, 202410:07 AM To: Eric Ekstrom<eekstrom@mii.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@ bid r.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson It's just something for the sheathing to run into. Shouldn't need any load applied to it. Can be non structural.All the webs in the truss should be able to be non structural. But it won't let me.To my knowledge they shouldn't have to brace that ledger to the smaller trusses running in front of it. It's just for sheathing to be ran into. From: Eric Ekstrom<eekstrom@mii.com> Sent: Friday, March 29, 202410:03 AM To: Eli St.John<eli.stiohn@bldr.com>;Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@bldr.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson t>:wk � :-.v��.,��✓s,?+`� ������ i��"�yk�� `�n�x .,„+'fr�:-..c`' ,r�r f��.< �� � .a� ,x 3° f'h vra�'.. ,r��,t ; �_ �.. -- 1 Do�nothck Imks or open attachrnentsunless you recognr�,e the senderatiyknow tieate safie � ' �� �` ;.° n✓�..tS..H: .. �s ,�..�:.,,�w�.,a,+�:.,.^°,.u,,.&.�',�`r.�'��,..a,;,�''a-, ,�,z',v�� � -',.'�,�,;a .,'^t,.ak..° r n ',... �,.,�,h,� Y,, zK,� rxx Looks like ledger is acting as backing for top chords of adjacent truss designs. From: Eli St.John <eli.stiohn@bldr.com> Sent: Friday, March 29, 2024 10:01 AM To: Eric Ekstrom<eekstrom@mii.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@bldr.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson That's confusing because the whole truss has continuous bearing so you wouldn't think anything in that truss needs to be structural, but it's forcing me to make webs structural.... Do you know why?Seems like a glitch? From: Eric Ekstrom <eekstrom@mii.com> Sent: Friday, March 29, 2024 9:59 AM To: Eli St.John<eli.stiohn@bldr.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@bldr.com> Subject: RE: R81578267-3720301-Hiline 1002-2465 Gustafson �. .. ;EXTERN � ✓i A�'3p"-�° � `�..`���"������� �xY x'� y.� T �e '3 � � :�# a"�Y �,� f{'�'� x � �"J �/,r �rrg � A �'a �;TI�IS�fnatl�Orlglrlated ftO�it OUtS tle O�tII�O�ganlzatlon �'��,�� �" ��:'�� ������ �,���� �•�� � err ��� � ` ✓ r ,�'�3,za 3 .� r s bx ' ��' �s�.r '` �� �5 �. ^Da n�c(iCk links or�pen attachments unless you�recogn�ze the senderand�know the tonEen`t issafie ` ��a� '� Good morning Eli,that brace cannot be removed on this design. Sorry,Thank You From: Eli St.John<eli.stiohn@bldr.com> Sent:Thursday, March 28, 2024 8:08 PM To: Eric Ekstrom<eekstrom@mii.com>; Cody Clarke<cody.clarke@bldr.com>; Matt Rogers<matt.rogers@ bid r.com> Subject: R81578267-3720301- Hiline 1002-2465 Gustafson 7 Hey Eric can I get a note on this gable truss saying that sheathing on one face of this truss accounts for the bracing on the 2x6 ledger. I sent for this and asked for it in the notes yesterday but it came back with no note. I,. Right click on any cell to view the list of menu options. IDf Tcking Nurnber lob�I�mi? Descrlpt�cr► 7= f f81�72fi7 372Q301 372rV93f1: }-tune i0€2 2465 Gc� taic�r } MiTek Inc. and its subsidiaries are a global operating company that serves its residential and commercial customers in North America, Europe, Middle East,Africa,and Asia Pacific.Additional information about our corporate organization is available at www.mii.com/corporate-structure/. MiTek Holdings, Inc..All Rights Reserved----This communication (including any attachments) contains information which is confidential and may also be privileged. It is for the exclusive use of the intended recipient(s). If you are not the intended recipient(s), please note that any distribution,copying,or use of this communication or the information in it is strictly prohibited. If you have received this communication in error, please notify the sender immediately and then destroy any copies of it. If the disclaimer can't be applied,take no action. MiTek Inc. and its subsidiaries are a global operating company that serves its residential and commercial customers in North America, Europe, Middle East,Africa, and Asia Pacific.Additional information about our corporate organization is available at www.mii.com/corporate-structure/. MiTek Holdings, Inc..All Rights Reserved----This communication (including any attachments)contains information which is confidential and may also be privileged. It is for the exclusive use of the intended recipient(s). If you are not the intended recipient(s), please note that any distribution,copying, or use of this communication or the information in it is strictly prohibited. If you have received this communication in error, please notify the sender immediately and then destroy any copies of it. If the disclaimer can't be applied,take no action. This message,including any attachments,may contain confidential and/or privileged information.If you are notthe addressee or authorized to receive this for the addressee,you must not use,copy,disclose,or take any action based on this message or any information herein.If you have received this message in error,please advise the sender immediately by reply a-mail and delete this message.Thank you foryour cooperation. 8 MiTek, Inc. 400 Sunrise Ave.,Suite 270 Roseville,CA 95661 916.755.3571 Re: 3720301 Hiline 1002-2465 Gustafson The truss drawing(s)referenced below have been prepared by MiTek USA,Inc.under my direct supervision based on the parameters provided by Builders FirstSource(Beaverton,OR). Pages or sheets covered by this seal: R81680624 thru. R81680625 My license renewal date for the state of Washington is April 30,2025. ON. 22037022 .April 4,2024 Reinmuth,Dustin IMPORTANT NOTE:The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s)identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown(e.g.,loads,supports,dimensions,shapes and design codes),which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only,and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSVTPI 1,Chapter 2. Job Truss Truss Type Qty Ply Hiline 1002-2465 Gustafson R81680624 3720301 A01 GABLE 1 1 Job Reference(optional) Builders FirstSource(Beaverton,OR), Beaverton,OR-97005, 8.630 s Aug 30 2023 MiTek Industries,Inc. Thu Apr 4 09:33:36 2024 Page 1 ID:YnmOU?Xrl16x6S5gGG6HJuzrmSN-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f -1-0-0 5:i5 10-0-0 14-5-11 1 30-0-0 31-0-0 4-5-11 4-5-11 -0- 15-0-0 14-0 Scale=1:52.4 4x5 5 6 3x10 i 5.00 FIT 4x5 11 4 7 52 53 3 4 8 0 0 41 51 3x1 I 54 2 2x6 3X10 I 9 10I� 1 3x4= 24 23 22 21 20 19 18 17 16 15 14 13 12 11 3x4= 5x8= 5x8= 30-0-0 3D-0-0 Plate Offsets(X,Y)— [3:0-2-0,0-0-3],[20:0-2-0,0-0-0),[20:0-4-0,0-3-0),[34:0-0-12,0-1-01 [37:0-1-14,0.1-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.15 TC 0.34 Vert(LL) -0.00 10 n/r 90 MT20 220/195 (Roof Snow=30.0) Lumber DOL 1.15 BC 0.15 Vert(CT) 0.00 10 n/r 120 TCLL TO Lumber Stress Incr YES WB 0.18 Horz(CT) 0.00 20 n/a n/a BCLL 0.0 Code IRC2018/TPI2014 Matrix-SH Weight:208 lb FT=20% BCDL 10.0 LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 DF No.1&Btr BOT CHORD Structural wood sheathing directly applied or 6-0-0 oc bracing. WEBS 2x4 DF No.2`Except` JOINTS 1 Brace at Jt(s):25 4-16:2x6 DF No.2 OTHERS 2x4 DF No.2 REACTIONS. All bearings 30-0-0. (lb)- Max Horz 2=99(LC 14) Max Uplift All uplift 100 lb or less at joint(s)2,18,23,17,9,16,12,11 except 20=223(1_C 14),13=146(LC 15) Max Grav All reactions 250 lb or less atjoint(s)18,19,21,22,23,24,15,14, 12,11 except 2=391(LC 21),17=447(LC 22),9=279(LC 22),20=989(LC 21), 16=495(LC 22),13=420(LC 22) FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=355/147,3-4=64/267 BOT CHORD 2-24=95/256,23-24=95/256,22-23=95/256,21-22=95/256,20-21=95/256 —WEBS 5 25=355/36,-6 l4 379/93,-1-7-41=371/93,-4 20=-664/184,3-20=-458/218, 7-16=-425/133,8-13=379/180 NOTES- 1)Wind:ASCE 7-16;Vult=110mph(3-second gust)Vasd=87mph;TCDL=4.2psf;BCDL=6.Opsf;h=14ft;Cat.II;Exp C;Enclosed; MWFRS(envelope)gable end zone and C-C Comer(3E)-1-4-0 to 1-8-0,Exterior(2N)1-8-0 to 15-0-0,Comer(31R)15-0-0 to 18-0-0, Exterior(2N)18-0-0 to 31-4-0 zone;cantilever left and right exposed;end vertical left and right exposed;C-C for members and forces &MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 1 >t2ET�r 2)Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 3)TCLL:ASCE 7-16;Pf=30.0 psf(Lum DOL=1.15 Plate DOL=1.15);Is=1.0;Rough Cat C;Fully Exp.;Ce=0.9;Cs=1.00;Ct=1.10 +` 4)Unbalanced snow loads have been considered for this design. ` '00< 5)This truss has been designed for greater of min roof live load of 16.0 psf or 1.00 times flat roof load of 30.0 psf on overhangs non-concurrent with other live loads. 6)All plates are 2x4 MT20 unless otherwise indicated. 7)Gable requires continuous bottom chord bearing. . 8)Gable studs spaced at 1-4-0 oc. "dfy 22037022 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)2,18,23,17,9, 16,12,11 except(jt=lb)20=223,13=146. April 4,2024 12)This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.112/2023 BEFORE USE. as Design valid for use only with II connectors.This design is based only upon parameters shown,and is for an individual building component,not MiTe . a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage.For general guidance regarding the 400 Sunrise Ave.,Suite 270 fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIrrPl1 Quality Criteria and DSB-22 available from Truss Plate Institute(www.tpinst.org) Roseville,CA 95661 and BCSI Building Component Safety Information available from the Structural Building Component Association(www.sbcscomponents.com) 916.755.3571/MiTek-US.com ` y mr b►�a s; t r . ra f ,r Notes A. PLATE LOCATION AND ORIENTATION 1/2 L Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 14- offsets are indicated. (Drawings not to scale) Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system,e.g. Apply plates to both sides of truss 1 2 3 Joint ID diagonal orX-bracing,is always required. See BCSI. and fully embed teeth. typ• TOP CHORDS 2. Truss bracing must be designed by an engineer.For ci-2 c2-3 wide truss spacing,individual lateral braces themselves 0-y1611 11 may require bracing,or alternative Tor I 0 WEBS qr4 4 bracing should be considered. ofO °' ,,� of 3. Never exceed the design loading shown and never O stack materials on inadequately braced trusses. U �oP = EL 4. Provide copies of this truss design to the building designer,erection supervisor,property owner and For 4 x 2 orientation,locate ~ cae csa c5-6 all other Interested parties. plates 0- 'lid'from outside BOTTOM CHORDS 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully.Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE locations are regulated by ANSI/TPI 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7, Design assumes trusses will be suitably protected from connector plates. THE LEFT, the environment in accord with ANSIITPI 1. `Plate location details available in MiTek CHORDS AND WEBS ARE IDENTIFIED BY END JOINT 8. Unless otherwise noted,moisture content of lumber NUMBERS/LETTERS. shall not exceed 19%at time of fabrication. software or upon request. r 9. Unless expressly noted,this design Is not applicable for i: f „'i' use with fire retardant,preservative treated,or green lumber. PLATE SIZE 10.Camber is a non-structural consideration and is the The first dimension is the plate ICC-ES Reports: responsibility of truss fabricator.General practice is to 4 x 4 width measured perpendicular p camber for dead load deflection. to slots.Second dimension is ESR-1988,ESR-2362,ESR-2685,ESR-3282 11.Plate type,size,orientation and location dimensions the length parallel to slots. ESR-4722,ESL-1388 indicated are minimum plating requirements. 12.Lumber used shall be of the species and size,and � LATERAL BRACING LOCATION in all respects,equal to or better than that � w specified. Indicated by symbol shown and/or 13.Top chords must be sheathed or pudins provided at by text in the bracing section of the Trusses are designed for wind loads in the plane of the spacing indicated on design. output. Use T or I bracing truss unless otherwise shown. 14.Bottom chords require lateral bracing at 10 ft.spacing, if indicated. or less,if no ceiling is Installed,unless otherwise noted. Lumber design values are in accordance wittTANSI/TPI 1 BEARING section 6.3 These truss designs rely on lumber values 15.Connections not shown are the responsibility of others. established by others. 16.Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports)occur. Icons vary but ©2023 MiTek®All Rights Reserved 17.Install and load vertically unless indicated otherwise. reaction section indicates joint number/letter where bearings occur. 18.Use of green or treated lumber may pose unacceptable Min size shown is for crushing only. environmental,health or performance risks.Consult with project engineer before use. Indust Standards: �, 19.Review all portions of this design(front,back,words ry and pictures)before use.Reviewing pictures alone ANSI/TPI1: National Design Specification for Metal is not sufficient. Plate Connected Wood Truss Construction. DSB-22: Design Standard for Bracing. 20.Design assumes manufacture in accordance with BCSI: Building Component Safety Information, ANsIiTPI 1 Quality criteria. Guide to Good Practice for Handling, 21.The design does not take into account any dynamic Installing,Restraining&Bracing of Metal or other loads other than those expressly stated. Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev. 1/2/2023