Loading...
HomeMy WebLinkAboutBLD2010-00148 Final Bedroom Addition - BLD Permit / Conditions - 10/18/2010 Inspection Line(36 0)4 27-726 2 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Irflo Shelton,WA 98584 RESIDENTIAL BUILDING PERMIT BLD2010-00148 OWNER: RICHARD MOORE RECEIVED: 3/5/2010 CONTRACTOR: LICENSE: EXP: ISSUED: 4/13/2010 SITE ADDRESS: 61 NE OLD BELFAIR HWY BELFAIR EXPIRES: 10/13/2010 PARCEL NUMBER: 123291300070 LEGAL DESCRIPTION: E 1/2 TR 7 OF SW NE *SURVEY 29/101 PROJECT DESCRIPTION: DIRECTIONS TO SITE: BEDROOM ADDITION ST RT 3 TO BELFAIR, L ON ST RT 300/ NORTH SHORE RD, STRAIGHT ONTO OLD BELFAIR HWY TO SITE ADDRESS ON THE LEFT SIDE General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 3 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 2 Occ. Group: R3 Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Valuation: Building Height: 12 Occ. Status: Basement: Addition 192 Manufactured Home Information Setback Information Shoreline& Planning Information Make: Length: Ft. Front: E 182.0 Ft. Shoreline: Ft. Water Body: Rear: W 108.0 Ft. Slope: Ft. SEPA?: No Model: Width: Ft. Side 1: S 26.0 Ft. Shoreline Desig.: Not Applicable Year: Serial No.: Side 2: NE 62.0 Ft. Comp. Plan Desig.: Urban Growth Area Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 3/5/2010 $199.71 S12010000 Planning Review Fee GMM 3/5/2010 $205.00 S12010000 EH Plan Review KKK 3/12/2010 $103.00 S62010000 Building Permit Fee LAW 3/15/2010 $307.25 S12010000 Building State Fee LAW 3/15/2010 $4.50 S12010000 Total $819.46 BLD2010-00148 Please referto the following pages for conditions of this permit. 1 of 3 CASE NOTES FOR BLD20 1 0-00 1 48 CONDITIONS FOR B LD20 1 0-00 1 48 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647 2. T person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Xepartmr�o n urther inspections being performed or approvals granted. 3) Owner/ � r pon ible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 4) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal ofapproved �v�uments will result in failure of required building inspections. ( 5) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X A;O(� 6) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or do st be reviewed and approved by Mason County prior to construction. X 7) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector s de rior to requesting additional inspections. X BLD2010-00148 Please referto the following pages for conditions of this permit. 2 of 3 8) All property lines shall be clearly identified at the time of foundation inspection. X_ � / 9) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason Co n or inances and building regulations. X 10) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder MMt2eaction from being taken. No more than one extension may be granted. X 11) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connector , flgshjng. Install metal connectors approved for contact with the new types of pressure treated material. X 12) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved S{�a�l n" to n re these structures are shown and meet the setback conditions listed. X 0 13) Approved p r ime i s and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X G 14) Prior to final approval, all upland areas disturbed or newly c at b o truction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X 15) All construction and demolition debris must be removed from the site after project completion. Proper al f construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X _M:lm This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owner or the agent on the owners behalf, represents tha he information provided is accurate and grants employees of Mason County access to the above described grope ructu r revie d i ction. OWN ER OR AGENT DATE: BLD2010-00148 Please referto the following pages for conditions of this permit. 3 Of 3 A o CONCRETE MECHANICAL MANUFACTURED HOME 3 o O o Footings!Setbacks Date Piping By Ribbons 0 oIntenor Date By Interior-Date By Date By n Exterior Date Exterior-Date By Set-LIP _ ;0 OD INSULATION n Point Load!Isolated Footings BG/SLAB INSULATION Date By D ---- --- Date _ By Data By FIRE DEPARTMENT Foundation Walls Floors Date By Date. By Date _ _ By DECKS FRAMING I Walls / Date By Date G-l3 -� BY ' J Data -�3 By 6C-� PROPANE TANKS PLUMBING vault Dates By Date By OTHER Groundwork Atdc I Date — 3-/Z> By !c.✓ Type- Date B Y Date B y D.w.)/ DRYWALL Type. int Brace Wall Date By 1001 Date By Date By FINAL INSPECTION p w Water Line Fire Seperation N �0 Date By Date By Date �� y'� �d By m O `° Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments � 00 a 8 2 - Cczc l< a A,r �s -i -43 1b s 4 I6.� \ J C= > Gam. 1 05'0 J MASON COUNTY PERMIT NO.&1e1Z()IU- 1148 BUILDING PERMIT APPLICATION „ e- E ru�� 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 1 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 m� On the web www.co.mason.wa.us APPLICA INFORMATIO CONTRACTOR INFORMATION Owner Company Name Maili X(d) ss Mailing Address City Statel Zip Code City State Zip Code Phone G Other Ph. Phone Other Ph. Lien/Title Holder Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic. # Qg2 Cf 06 Q0 106 Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well Sewer System Name of Sewer System PARCEL INFORMATION - 1 Di i Parcel No. Fire District Legal Description Site Address (Please inclu a street name, street nurnlaer and city) Dire tions to site Will timbl6r be cut and sold in parcel preparation? es Is property within 200' of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluff 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/No TYPE OF JOB - New�—Add Alt Repair Othe PRIMARY RE IDENCE SEASONAL ❑ Use of Building tde:7e;eipl Describe Work w. No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor 2nd Floor 3rd Floor Basement Deck— Covered Deck Other Sq. ft Garage Attached Detached Carport Attached Deta MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price $ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the informaticn provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced withO 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS A PRO ESS INS TI .1 CTIVITY OF THIS PERMIT APPLICATION OF 180 YS W L INVALIDATE THE APPLICATION. 1-0�X Date: Owner/Owners Representative/Contractor (indicate which one) FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Dat DEPARTMENTAL REVIEW AFRROVED DENIED NOTES Building Department Planning Department I OL U Environmental Health Department Fire Marshal n FEES i Building Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbin & Base Fee PlanningReview Fee Mechanical & Base fee Other /Gas/ Pellet Stove Fee State Fee ion Fee Pre-Paid at Submittal at $ TOTAL FEES „ --.,MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST Owner's Name: ( . Date: 3- -2f)10 Reviewed By: Documents:/ _V Building Permit Application Completed ✓Stormwater Checklis ✓ lanning Intake Checklist Completed, t�1(NL n v 440(MLvAl gt' _✓Site plan includes:Allowable building area,roof angs,decks, etc. _Fire Apparatus Access Road info required? Yes No 1,1 _Energy Code Application Form- O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) ' O Other: Specify: _Mechanical/Plumbi�Application-WATER HEATER FUEL TYPE/LOCATION _Engineering? Ye�0 Snow load: Seismic: Stock Plan-approved snow load: Seismic: \'IvVfanu actu ed mes-4 FLOO PL S Foun tion Type: NSL'Man acture met d neered f mg/foun ion Basement Decks: vere Uncov r 4 x 6 and oNver3 Construction plans requir Constructio Plans:_3 COMPLE�E SETS Plans Legible V Recognized Scale _✓E vation Views �oss Section Foundation Plan Roof Framing Plan loor Plan- Use of rooms noted(all floors) Floor Framing Plan-all floor levels including loft,crawlspace,etc. (400 S.F.??-stairs?) g Plan Detail . Roof framing details,truss lay-out may be needed (Hip and girder location shown) nrl l Tru"V725 Wall Framing-Does bearing-wall height exceed 10'?(Engineering m4aT be required) Floor framing: Floor joists(size&spacing):..�[X JO , Floor beams: �4 X 6 _Window headers. Typical header: to QG v1Foundation: footing size, reinforcement 00 Concrete Walls-Does Concrete Wall Height Exd 8'9(Engineering may be required, see details) _Landings at all exits?Less than 30”above grad Y/N _Heated By Furnace-Location of Furnace Fuel type: ve orma io - Location(s): _Window Sizes Marked on Plans Braced wall panels(shear walls)marked on plans or lateral engineering? 2-stet�tgar�g®�-(I�ngir�eerin^^"a�.hP rvnnirPrll In �� ffi■n etn■ r�„ill dCo/ Tl7 5,��(B COMMENTS: a�- or) A60 Luc- t ENGINEERING REQUIRED Braced wall paneWbrace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: , Snow ..psf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2) Roof or floor is not laterally supported on all edges 2A) Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3) End of BWP extends more than 1 ft. over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft. or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7) When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys, and veneer). When this applies the entire story shall be designed. In accordance with accepted engineering practice. H:\permit tech building checklist.doc Revised 11-29-2007