Loading...
HomeMy WebLinkAboutCOM2015-00013 Final Chruch, Parking Area and Stormwater Features - COM Permit / Conditions - 8/11/2017 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line (360)427-7262 PSo co�HTt Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar Shelton, WA 98584 lR34 COMMERCIAL BUILDING PERMIT COM2015-00013 OWNER: ASAMBLEA DE DIOS INTERNACIONAL RECEIVED: 2/2/2015 CONTRACTOR: SOUTH SHORE CONSTRUCTION southshore@q.com LICENSE: SOUTHSCO16NL EXP: 2/10/2C ISSUED: 5/7/2015 SITE ADDRESS: 2221 NE STATE ROUTE 300 BELFAIR EXPIRES: 11/7/2015 PARCEL NUMBER: 123313200040 LEGAL DESCRIPTION: TR 4 OF GOUT LOTS 3-4 PROJECT DESCRIPTION: DIRECTIONS TO SITE: NEW CHURCH BUILDING AND ASSOCIATED PARKING TAKE ST RT 3 NORTH TOWARD BELFAIR, TURN LEFT ONTO WA-300 W, AREA& STORMWATER FEATURES. TAKE THE 1 ST LEFT TO STAY ON WA-300W, SITE ON THE LEFT General Information Construction&Occupancy Information Type of Use: COMMERCIAL Insp.Area: No. of Units: Type of Constr.: VB Type of Work: NEW Fire Dist.: 2 No.of Bathrooms: 4 Occ. Group: A-3 Valuation: $ 1,467,472.58 No. of Stories: 2 Exit Design. Load: 600 Building Height: 33 Pre-Manufactured Unit Information Square Footage Information Make: Length: Lot Size: Model: Width: Building: 6,196 Year: Serial No.: Basement: 1,650 Parking Spaces: Setback Information Shoreline&Planning Information Front: E 25.00 Ft. Shoreline: Ft. Rear: W 25.00 Ft. Slope: Ft. Water Body: Shoreline Desig.: Not Applicable Side 1: N 120.00 Ft. SEPA?:No Comp. Plan Desig.: Rural Side 2: S 185.00 Ft. Fire Protection System Information Auto Fire Alarm System?: Emergency Key Box?: Y Standpipe?: Auto Fire Sprinkler System?: Y NFPA 13 Access Road?: Y Fire Extinguishers?: Y Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: Y COM2015-00013 Please refer to the following pages for conditions of this permit. Page 1 of 9 Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Hosebibs 1 Exhaust Hood 1 Plan Check Fee 1RN 9l9nniu �a 7ra r» g99n1rnn Kitchen Sink 3 Heat Pump 3 Planning Review Fee JRN )l,)/7ni5 ­iRn nn g99n15nn Lavatories 6 Ventilation Fan 4 IFC Plan Check Fee JRN ?l?lgni c; a?17R ni g99n1 c;nn Water Closets (Toilets) 9 EH Plan Review JRN )1919n15 RgnS nn C99n15nn Water Heaters 1 Planning Stormwater Rey /;Rahn 919R»n1t; oar,nn qi?nirnn Building State Fee RTR r,/5/7ni5 Pd 5n C1gn15nn Building Permit Fee RTR 5/519n15 !t7 11R Q5 C19ni1;nn Mechanical Permit Fee RTR 5/517n15 Mini An R1gni5nn Mechanical Base Fee RTR F/Fl7ni F 1 qR Fn g19n1 rnn Plumbing Permit Fee RTR F/S/7n15 M71 5n gi9n1rnn Plumbing Base Fee RTR 5/519n15 (49a 7n C17ni rnn Total $15,573.98 CASE NOTES FOR COM2015-00013 CONDITIONS FOR COM2015-00013 1) Final approval on SWG2013-00139 must have final approval of installation prior to temporary/final occupancy. X 2) Approv d per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 3) All construction and demolition debris must be removed from the shore area after project completion. Proper disposal of construction debris must be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X 4) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing, surface matting, or straw). X �,`'� ,L 1 5) Parking shall be sufficient for 72 standard parking stalls (9 feet by 26 et) and 5 handicap parking stalls (12.5 feet by 20 feet)with sufficient maneuvering aisles-, additional 40 parking stalls provided for larger events. Handicap stalls shall be of a smooth surface at level or ramped to entry, located closest to the building entry and shall be signed with the International Symbol of Access. Screening from adjacent residential properties is required. X \,! '' 1 6) All surface water and potential Hoff from the proposed development will be controlled on site and shall not adversely affect any adjacent properties, cause sediment deposits, nor increase the velocity flow entering or abutting to any state or county culvert or ditch system or road way. COM2015-00013 Page 2 of 9 7) Compliance with an approved Storm Water Plan shall be subject to an on site inspection, or inspections, by the engineer of record or an authorized representative. Said inspection(s) shall be performed in accordance with the approved plan, and prior to any modification that would make a determination of compliance impossible. Inspection reports shall be submitted to verify all engineering requirements have been completed in accordance with the approved storm water plan. Reports shall be submitted to the Mason County Department of Community Development prior to each corresponding inspection and final permit epprpval Copies of all special inspection reports shall be made available at time of inspection. 8) All pro erty lines shall be clearly identified at the time of foundation inspection. X ( � 9) Landings and stairs must meet the same setback conditions as any permitted structure, and, must be shown on your site plan. Please check your "Approved Site,Plan"to ensure these structures are shown and meet the setback conditions listed. X 7 10) By define propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. X ��� 11) Retainin� alls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 12) All other necessary permits from Mason County, Washin n State and/or Federal Agencies that are required for this proposed development and construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X 13) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept abor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982 Th erson signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X ' '1 1. 14) All approved plans are re ed to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour w I be,charged and collected by the Mason County Building Department prior to any further inspections being performed or approvals granted. X 15) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X ��� ved site plan is required to be on-site for inspection purposes. If inspection is called for and the site plan is not on site, Approval WILL 16) The ap�pr4 NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason County B ildin Department prior to any further inspections being performed or approvals granted. 17) A concre ncased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I). information. In Olympia call 360 902-6350 and in Bremerton call 360 415-4000. For more information contact L&I for additional ( ) ( ) X COM2015-00013 Page 3 of 9 18) 3000 PSI CONCRETE WILL REQUIRE SPECIAL INSPECTION IF THE QUANTITY EXCEEDS 50 CUBIC YARDS< LESSER AMOUNTS WILL REQUIRE AN APPROVED CONCRETE SUPPLIER TO PROVIDE YOU WITH A BATPH TICKET THAT WILL BE REQUIRED TO BE SUBMITTED TO THE SITE INSPECTOR FOR THE VERIFICATION OF MATERIAL USED. X 19) Structural observation shall be performed and structural observation report(s) shall repared in accordance with Section 1704.5 of the current International Building Code. Structural observation is the visual observation of the structural system by a registered design professional for general conformance to the approved construction documents. Report(s) shall be provided to the Mason County Building Department at 426 West Cedar street, Shelton, WA 98584. Reports shall be submitted to the Mason County Building Department prior to framing inspection. A final observation report shall be submitted prior to the final inspection of the structure. Written statements shall indicate the permit number, type of inspection, and identify any reported deficien ies., X �. 20) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17. 1.) Field welding must be performed by a W.A.B.O. certified welder. 2.)A325 High strength bolts. Special inspection reports shall be submitted to the Mason County Building Department, PO Box 279, Shelton WA 98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final oc inspections. X 21) Any ch nges in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collecked by the Mason County Building Department prior to any further inspections being performed or approvals granted. X 22) ALL ONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF PSE OR OCCUPANCY WOULD RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x 23) Provisions for surface/subsurface drainage control must be implemented with new con ction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned wQrk which,may affect your project. X�, 24) Changes to a�fbved building plans that affect compliance to the current Washington State Energy Code (WSEC), ventilation requirements), Buildin /Plu �i /Mechanical Codes and/or Mason County Regulations shall be approved prior to construction. X COM2015-00013 Page 4 of 9 25) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County uilding Inspector shall be made prior to requesting additional inspections. X r-• 26) All bui w g permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-com liant with ),Mason County ordinances and building regulations. X 27) All per s expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the per it 0911er have prevented action from being taken. No more than one extension may be granted. X 1 28) PressL[e1reated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fastene s, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 29) ACC IBLITY EXCEPTION: Each toilet and bathing room shall be designed and constructed to be accessible to persons with disabilities in accordance with the 2012 International Code and ICC A117.1. Referencing IBC Section 1109 the following exception applies. All elements listed shall apply to qualify for the exception. EXCEPTION: In toilet rooms or bathing rooms accessed only through a PRIVATE OFFICE, not for common or public use, and intended for use by a single occupant, the following alternatives are allowed: 1) Doors are permitted to swing into the clear floor space, provided the door swing can be reversed to meet the requirements in ICC A117.1; 2)The height requirements for the water closer in ICC A117.1 are not applicable; 3) Grab bars are not required to be installed in a toilet room, provided the reinforcement has been installed in the walls and located so as to permittee installation of grab bars; and 4)The r guir ent for height, knee and toe clearance shall not apply to a lavatory. X i � 30) COMMERCIAL KITCHEN HOOD: All commercial kitchen hood systems shall be protected with a UL300 compliant automatic fire extinguishing system installed in accordance with manufacturer specifications and maintained as required by the 2012 International Fire Code, Building Code, and International Mechanical Code. The system shall be inspected and tested for proper operation at 6-month intervals unless approved otherwise. Maintenance records shall be available for inspectors during inspections. As per IMC table 507.2.2 as amended by Washington State the minimum hood required for a church that will be boiling, steaming, and warming precookeed only is a type II hood. X COM2015-00013 Page 5 of 9 31) FIRE EXTINGUISHERS: Install 2A10BC fire extinguishers throughout the building in accordance with chapter 9 of the 2012 International Fire code. The fire extinguishers shall be installed such that the extinguishers are located not more than a travel distance of 75 feet in any direction and mounted no more than 60 inches above floor to the top of the unit. At least one extinguisher is required on every level or floor. Not less than 1 type K portable fire extinguisher shall be located in the commercial kitchen area, within 30 feet of the cooking appliances and no closer than 10 f et. X KEY B REQUIRED: A key box/knox box is required to be installed in accordance with the 2012 International Fire Code Section 506. Please contact the local fire district for mor information and to discuss inspections for installation of the lock box system. X 32) ADDRES ONDITION Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. Commercial structure mile point number or unit designation posting requirements: 50 feet or less setback shall post a 6 inch minimum with a 3/ inch stroke. 50 feet or more setback shall post a 12 inch minimum with a 1 'h inch stroke. Designating unit on a building will be no less than 6 inches in height with minimum 3/ inch stroke. Designating unit on a door will be no less than 4 inches in height with minimum '/2 inch stroke 100 foot setback or less shall post 18 inch minimum with 2 inch stroke. 100 fgot sk or greater shall post 24 inch minimum with 3 inch stroke. Xl 33) POS CCUPANT LOAD Every room or space that is an assembly occupancy, such as a restaurant, bar, or meeting room, shall have the occupant load of the room or space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved legible p rmaperlt design and shall be maintained by the owner or agent. (IBC1004.3) X 34) EXITS IT ACCESS DOORS All doors shall be side hinged and swing in the direction of exit travel. All exit doors shall be illuminated at all times that the building is occupied and be equipped with approved accessible hardware that does not require tight grasping, tight pinching or twisting of the wrist to operate. ALL exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. All exit signs shall be intern Ily or externally illuminated at all times and equipped with to ensure continued illumination for a duration of at least 90-minutes. X /I COM2015-00013 Page 6 of 9 35) 2012 IECC/WSEC COMPLIANCE: This project is approved for compliance to the 2012 International Energy Conservation Code/Washington State Energy Code (IECC/WSEC); components shall be installed as follows: ENVELOPE: Prescriptive Using Table C402.2 Roof: Metal building with R3.5 thermal blocks, R-11 liner system PLUS R25 continuous non-compressed insulation Wall insulation min R13 continuous insulation + R-13 wall insulation or better, Slab insulation R-10 or better installed in around the entire perimeter from the top of the slab edge to the bottom of the footing. Fenestration including doors and windows, including store door(s) shall have a U-Factor as follows-fixed/non operable windows .38 and operable windows U-0.40or less, entrance doors U0.60 or less and skylights U-0.50 or less. Solar heat gain coefficient(SHGC) 0.40 or better except skylights SHGC 0.35 or better. OTHER DOORS: Other than entry doors U-0.37 or less and roll-up or sliding doors min. R-4.75. DEFERRED SUBMITTAL IS APPROVED FOR ELECTRICAL POWER AND LIGHTING SYSTEMS and the MECHANICAL SYSTEM. COMPLIANCE INFORMATION SHALL BE SUBMITTED TO THE MASON COUNTY BUILDING DEPARTMENT AND APPROVAL OBTAINED BEFORE THE FRAMING INSPECTION. THE FRAMING INSPECTION WILL NOT BE APPROVED UNTIL DEFERRED SUBMITTAL DOCUMENTS ARE APPROVED AND ISSUED BY THE MASON COUNTY BUILDING DEPARTMENT. LIGHTING: DEFERRED SUBMITTAL Total interior lighting shall not exceed 4637 watts, or provide a design calculation demonstrating compliance to IECC/WSEC C405. Lamp wattage shall be calculated using the lamp and ballast or for incandescent fixtures, using the maximum labeled wattage allowed and is approved as follows: Provide a lighting plan showing the layout of all lights and controls along with a schedule that identifies the wattage for ballast and lamps. The plan and information shall be submitted to the Mason County Building Department for review and approval prior to the framing inspection. All daylight zones shall be provided separate control in accordance with IECCWSEC. Automatic daylight sensing controls shall be capable of reducing light out put, that control luminaries only within the day lighted area, shall be clearly identified. Switches shall be equipped with separate automatic controls to shut off the lighting in all spaces during unoccupied hours. Occupancy sensors shall be capable of automatically turning off all lights in an area in accordance with IECC/WSEC. Exterior lighting shall not exceed 750 watts or provide a design calculation demonstrating compliance to IECC/WSEC C405 or as otherwise allowed in the IECC/WSEC. A lighting plan and summary shall be submitted to the Mason County Building Dept. for review and approval prior to the framing inspection. MECHANICAL SYSTEM: DEFERRED SUBMITTAL A mechanical plan was not included with the plans submitted for approval. Deferred submittal shall include compliance forms attached to the approved construction plans, details and information about equipment and system, along with plans demonstrating compliance to IECC/WSEC C403. Mechanical systems and equipment serving heating, cooling, ventilating, and other needs with Section C403.2 and either C403.3 or C403.4. Walk-in coolers and walk-in freezers shall comply with C403.5. Refrigerated warehouse coolers and refrigerated warehouse freezers shall comply with C403.6. COM2015-00013 Page 7 of 9 MECHANICAL SYSTEM - NON RESIDENTIAL: Those parts of the mechanical system that are altered or replaced shall comply with Section C403 of the 2012 International Energy Conservation Code as amended by Washington State (IECC/WSEC), ref C101.4.3.2. Heating and cooling loads shall be determined. The out put capacity of heating and cooling equipment shall not exceed the load calculated. Heat and cooling load calculations shall be provided on site for inspection. HVAC equipment shall meet or exceed the minimum efficiency requirements specified in section C403.2.3 and applicable tables. Unless approved otherwise: HSPF rating (heating) shall be 7.7 or better, 3.3 C.O.P or better, and SEER rating (cooling) shall be 13.0 or better Warm air gas fired furnaces shall have an A.F.U.E rating of 78% or better. Com ian a inf rmation shall be provided on site for inspection. X OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. ign re Date 1( LI r L/ OWNER - REPRESENTATIVE - CONTRACTOR Print Name (Circle one to indicate) -- COM2015-00013 Page 8 of 9 :e V�a3� r' uU i i NVld 1t211LLo311HOLIV C3W NV Z ll/�IO N33(iLL39 31VNIoai0011 Ol 31919NOd93Zi 91 61010VM1N00 '9NOI-W Ol aNV 9N019N34o / I , 3aVAOLtW Ol NV-W 3119 1VaR1�311HZNV'NV 91 91H1 O/ / '310N / I , I = M3N ON'9VNINVld 3dV'�aWl CrajrA a33(p a32/1(lo3al 93aINOWl J NOUV130dA x-N1191X3 3213MI11 / 'I �I, 1 I (D (D 1310N 00V33a119 A.21019 213ow1(1) slo wa a 9i'�16�3d11wo.i / \ ,00v933a11 Ad0NVO(4) / I' '9VNI1NV'ld'NW E�Wf110ll0d 3Hl Hll1f1 301f11,G: V 3dAl OWVA bla* 1e 3dV09aNVl uollualaa i41 Q lelemwiolg t 1 I ( 'a,0 V I / . d9 ltnlo al3d NOI1N313a d1130Vd9 Vd '993ooV'V3•V 361 Nhl9 1VwuorwlQ al3d-17vm wV13a1 \ �! 0, Gairlow 3191993o0V Ow 3a it i9 Noi fJ \ I'IV-H9'Nv-u 3119 V1N3 339 / \ OOIL m:1 \ in 3NVl3aild \ dAl awl �3s�ruallna,aL N dAl awl A1LI3d021d 1 \ A 9r10(1Qlo3o rH.P0.1Vh L a 3dA1 wig ?Z , 9(IOf1Qlo3 H H(9 / ,001/93iaLL A210182134Nf1!L) QW31-110 Afl NvI93a \ "�• ' \ r / / dWn10 W319-I11114'H,9 ! ` •` \ �� 210 W319 31V119 N3dI1VO,.L W319A9 olld39 338 ^��\ ` \ \ / < ! -0OV33211 AdONVO(I) '9'7w1NVld WIIWINIW vNIM011Od Be 3Hl HIM 301M;01 (3WVA NB=6 Q 3dVO9aNV1 dAl 3NIl OmIVA Wa;j; 1S7 3dV094NV1 'dAl 3w1 4002i 993OOV 990%0V a3J02AIIW Be aNV I .^�` •��` �� , i7NV�I1N3 A9 a3d(10LIO 39'9NJV1 OIld39 CWAVI Ol 1Nv-W AlNO 9NOUVOOl 393H1 -a3a1319m1 99r%wH9 oa1VA Namu1O dw I , 1 , i n � rn C3 co rn m.: �G m •vr / 0 m. -+ W S o d C m.. ( � C: ' W r= Cnch . Q C 0z < z fn z •. UV o , 0 ' •�� . I 31RIVE c\ .... . IEbg AREA rrri r, SEE SEPTIC SY DESIGN BY OTI ' '• _! .•/ � ir1.I fry([� \ / / `\ ,.. ` SIGN TYPE B t PROPERTY L IN -mg 0 81 / WISHFIRE.LANE 04t" `t FINISNEk�' � ``, / SEE ENLAI's / r FOR SIDEWA t} d, , ,FF 2100 FF`33 ROUTES tY RETAIN[ WALI ,r41 .A SIGN T PE PA SPAC SP � JJ / o - `�. I Storrriwater o .M. D L Detention T ca v c , �o LANDSCAPE BUFFER YARD TYPE A- I / 5' WIDE WITH THE FOLLOWING MIN. PLA (b)CANOPY TREES/100! / 2" CALIPER, SINGLE STEM-OR m I I r S' H.MULTI-STEM CLUMP, Q7 �1 (I) UNDER STORY STREE/100' m _ I // r V.H. DECIDUOUS, o NOT�1 E: �+ / WHERE EXISTING VEGETATION PROYI I. BUFFER YARD LANDSCAPE PLANTING LANDSCAPING REAUIREp /, ! NOTE: / THIS IS AN ARCHITECTURAL 84 PL DIMENSIONS AND LOCATIONS. CON 1 RESPONSIBLE TO COORDINATE BE ` PLAN AND ARCHITECTURAL PLAN. MASON GOUNTYI Permit No:yp)a 015.owl i L DEPARTMENT OF CObIMUNITY DEVELOPMENT BUILDING•PLANNING•FRREMARSHAL (360)427-9670 Shelton ext.352 http:/Avww,co.mason.wa.us/community dev/ (360)275-4467 Belfair ext.352 s, 426 W Cedar Street,Shelton WA 98584 (360)482-5269 Elma ext.352 BUILDING PERMIT APPLICATION RECEIVED PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: NAME: c�ti F E B 0 2 2015 MAIL G ADDRESS: � ( MAII. G ADDRESS: C CITY: STATE. ZIP: Cny STATE:.ZIP: 426 W, CEDAR S T. PHONE CELL: PHO CELL: EMAIL: EMAIL L&I REG# EAR 1 /10/ t • CONTACT: OWNER❑ CONTRACTOR BELOW❑ NAME: MAILING ADDRESS: O. x BUILDING CITY: STATE: ZIP: PHONE: CELL: 0 ) EMAIL: ft=' ye&q PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER) 3 2-000`f O FIRE DISTRICT LEGAL DESCRIPTION(ABBREVIATED): -M i 01= F o VT L01-c� '�-t- S 3q 12 S7 SITE ADDRESS 2221 NE St7til= IzyATr- 300 CITY VELPAIP- DIRECTIONS TO SITE ADDRESS 1 f T o TU N O --TM:;F 000. SIT$ Is �T• " IS PROPERTY 7MMM 200 FT: SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ : DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN I^ YES❑ NO 4V TYPE OF JOB: NEW S ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE IDINCE,GARAGE ETC.) IS USE: PRIMARY K SEASONAL❑ NUMBER OF BEDROOMS n JCk NUMBER OF BATHROOMS__ DESCRIBE WORK SOUARE FOOTAGE: 1ST FLOOR.Ja sq.ft 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENTL(60 N.S DECK sq.ft. COVERED DECK sq.R STORAGE sq.it. OTHER sq.ft. GARAGE sq.R ATTACHED❑ DETACHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑ MANUFACTURED INFORMATI •4 COPIES OF THE FLOOR PLAN REQUIRED MAKE DEL YEAR GTH WID BE BATH SERIAL NTOaWR OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner or owner's legal representative.I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal 5 representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) x 'e-2t � 212-115 Signature of OWNER Date DEPARTMENTAL REVIEW APPROVE DA DENIED DATE TAGS/NOTES/CONDMONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL FEES TOTALfd'e1LUATION:. BUILDING PERMIT FEE FME ACCESS AND GRADE PLAN REVIEW GEO-TECH REVIEW PLUMBING&BASE FEE STORMWATER REVIEW MECHANICAL 8c BASE FEE I TOTAL FEES WOOD/GAS/PELLET STOVE VIOLATION INVESTIGATION FEE PLANNING REVIEW FEE VIOLATION FEE r6 cot, MASON COUNTY' BUILDING PERMIT NO. aO�S- DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING•PLANNING•FIRE MARSHAL WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352 Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352 185 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352 PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: m NAME: U MAILING ADDRESS: �) v' I in. MAILING ADDRESS: b CITY: Ibi If7A i y STATE:VVA ZIP: 99Z CITY: Y STATE: ZIP: PHONE:3(L D =115-Q18 CELL: 31p0 -Jj 09-(3 L12 PHONE: -Z -0$t3 CELL: -izu, EMAIL:_ A EMAIL : , O L&I REG# UN L EXP.-Z U /A-0 PARCEL INFORMATION: PARCEL NUMBER(12 DIGIT NUMBER): 2�3J - 22 'D0010 LEGAL DESCRIPTION(ABBREVIATED): T47- + 0E- (M VT LptZ 3--I- S �q 2 27 SITE ADDRESS: 2221 N E sJJ'(t-- 4?-ouTa a D O CITY: I R- DIRECTIONS TO SITE ADDRESS: t WAV IN tr- N off- i ON tJ W ye �i,�-U. -N LF7' nN s 7 g-DUJr-- Sa-F— IsDN L4--- -FT, TYPE OF JOB NEW)_ADD ALT REPAIR OTHER USE OF BUILDING C,,fiU fl (A -3) LOCATION OF FIXTURES/UNITS—1 IT FLOORS_2D FLOOR BASEMENT < GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Eixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_ Toilets Type of Unit No.of Units Fees Bathroom Sink Furnace Bath Tubs Heatpump Showers Spot Vent Fan Water Heater --T Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove E Dishwasher Kitchen Exhaust Hood ) Hosebibs Dryer Vent FEB 0 2 2015 Other Other Base Fee Base Fee 426 W. CEDAR ST. TOTAL PLUMBING TOTAL MECHANICAL OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLIC IO OF 180 DAYS WILL INVALIDATE THE APPLICATION. X (� 47 (nryl, gnature�ofApplic1a/nt at X_ /��"to�P 1. Owner/Owners Representative/ ontracto Print Name (indicate which one) DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT S PLANNING DEPARTMENT FIRE MARSHAL �wv�rotech �>tig�weer�wg Cject!3 !.V icn! ° Ev)"Ayov.w .vv�ta! °DYn:Nnpv_ October 31, 2016 RE Mason County JED Department of Community Development V 02 2016 615 W Alder Street CQJNTMPU8LICW Shelton, 9 on Washington 98584 ORKS Asamblea De Dios Internacional Agua Viva 160 NE Santa Maria Lane Belfair, Washington 98528 RE: Iglesia Asamblea de Dios COM2015-00013 To Whom It May Concern: Envirotech Engineering provided a recent letter dated October 8, 2016 (see enclosed) addressing concerns from Mason County in a letter dated August 15, 2016. This letter further justifies our design and addresses the enclosed resubmittal per item #15 on the aforesaid County letter. There are a few discrepancies between our described land use areas with relation to our stormwater modeling. However, the basis of our original infiltration pond design utilized an impervious contribution of 1.75 acres, whereas planned conditions are only 1.17 acres. This 50% increase is extremely conservative, and provides a pond size adequate for this project. Envirotech reviewed our calculations utilizing actual impervious areas with the infiltration rate reduced to 2.4 in/hr for both cells of the pond. With a reconfigured cell 1 to meet the stormwater manual, and the reduced infiltration rate, the infiltration pond is deemed over-sized after accounting for a 6-inch sediment storage depth and a 12-inch freeboard. On sheet 1 of the plans, the pond has been reconfigured with a new cross section showing all pond elements, design criteria and hydraulic profiles. This includes general topography indicating that the pond is entirely within a cut section. PO BOX 8 9 4 Belfair,Washington 98528 Off: 360-275-9374 Cell: 36o-689-6045 Details for the berm, weir, emergency spillway, debris barrier, and all scour control are provided on sheet 3 of the plans. Temporary erosion control concerns within item #15 of the County letter have been addressed in our previous letter. Please call Michael Staten at 360-275-9374 if you have any questions regarding this letter. Best Regards, Envirotech Engineering AFL C LYDF ST GX% �r7STER� �SS�a �At F^„c �oi3 vi6 Michael Staten Project Director Cc: Mason County Department of Public Works 100 W Public Works Drive Shelton, Washington 98584 G-VWL'rotech c,eoter'kVacaL 0 ev"V%rov�wv.ev&tal .pY.61 v.age ° Roadwau October 8, 2016 Mason County Department of Public Works 100 W Public Works Drive Shelton, Washington 98584 Asamblea De Dios Internacional Agua Viva R�C���E� 160 NE Santa Maria Lane Beifair, Washington 98528 NOV 0 2 2016 615 W. Alder Street RE: Iglesia Asamblea de Dios COM2015-00013 To Whom It May Concern: Envirotech Engineering is providing this letter to address concerns from Mason County in a letter dated August 15, 2016. We visited the project site on September 9, 2016 in order to observe current site conditions. The following items directly correspond to the aforesaid letter. 1. Sheet 1 of our plans depicted a 10-foot buffer (clearing limits). According the contractor, it is our understanding that the architectural plans depict the 10-foot buffer as vegetative landscaping. This is acceptable to Envirotech as it should be re-vegetated. 2. Per Sheet 2 of our plans, we recommended one construction access off of State Route 300. Temporary access from Gladwin Road should be removed by not using, and placing temporary seeding to stabilize the area per the drainage plan. 3. Stabilizing the Gladwin access and drainfield areas with temporary seeding will control flow rates. It is our opinion that flow from a 2yr-24hr construction design storm will disperse and infiltrate prior to leaving the site. However, the stormwater plans indicates that if drainage is not functioning as intended, additional provisions/ drainage facilities will be required such as silt fencing. PO BOX 984 Belfair,Washington 98528 Off: 360-275-9374 Cell: 36o-689-6045 r 4. All sediment/temporary erosion controls should be implemented per the approved plans. This includes silt fencing as necessary and seeding unworked denuded areas. It is our opinion that the existing pond is sufficiently sized for the temporary 2yr-24hr storm event, and may be used as a temporary sediment pond. Upon project completion, the temporary pond should be enlarged per the drainage plan. 5. Soil stabilization is provided in the stormwater plans, and should be implemented for this project. Wet season erosion control provisions are provided in the plans, and should be completed on or before October 1st 6. Slopes must be protected per the erosion control plan. Vegetation and/ or plastic cover, as necessary should be implemented. 7. Our initial evaluation was intended to be worst-case-scenario, and that the natural swale on the west side of the property may possibly convey surface water. We did not observe scour within the swale, but did notice some erosion in the right-of-way to the north of Gladwin Road near the swale end. It is our opinion that the established drainage conveyance system within State Route 300 is adequate for diverting stormwater away from the project during storm events. We believe that significant runoff that could enter the site would most likely be from un-maintained drainage conveyances upslope from the project or from storms exceeding the 100yr-24hr event, which are not designed for. In conclusion, it is our opinion that the designed ponds are adequately sized for the new development plus design storms contributing to the retention pond. 8. In-situ infiltration measurements were not performed. Based on soil type and experience performing field infiltration tests, we believe that our infiltration rates based on the USDA classification is much more conservative than performing in-situ measurements. Sheet 1 of the plans depicted soil logs for each of the five test pit excavations. No mottling was observed. The pond test pits were observed to a depth of 8 feet, which is 0.5 feet below the final pond bottom. Envirotech recently hand excavated to a depth of 3 feet below the bottom of the expected pond depth with no change in materials to report. An operation and Maintenance Plan was prepared by Envirotech during the design of this project. An O&M agreement recording should be a condition of permit by Mason County. 9. Unless upslope drainage facilities beyond the project fail, or severe storms occur above ordinary design storms (see #7 above), we believe runoff entering the property is negligible. This is also substantiated by periodic observations over the past 3 years. It is our opinion that the small portion of the north-east property corner is not significant of an area to generate runoff to off-site properties, especially after re-vegetating per plan. Bare dirt areas of the property are temporary until construction is complete and the ground is either fully developed or revegetated. Although the revegetated areas will have a little more runoff potential than pre-existing site conditions, the additional runoff is negated as the runoff from the developed areas are controlled. The land area that will be developed is not contributing runoff as it did during pre-existing conditions. 10.The drainage manual recommends that infiltration facilities are at least 100 ft setback from on-site septic components. This appears to be adhered to. Infiltration facilities appear to comply to the State Department of Health wellhead protection program. The proposed drainage facilities are over 1000 feet from Lynch Cove and Ridgerunner water systems. Furthermore, the hydrogeologic setting is acceptable for the planned drainage systems not to contaminate any private well systems. 11 . Factoring the design storms and development areas, the proposed size of the infiltration facility has a volume relationship similar to other developments within the area. Envirotech will re-examine the facility sizing, and if necessary, provide a revised pond size along with a re- submittal per item #15 below. 12. Based on proponent provided information, the use of this project will render an approximate average of 30 trips per day of traffic. Other than the low volume of traffic and ordinary landscaping maintenance, other pollution generating activities are not anticipated. From the drainage manual (Vol V), this is not considered a high use site, and basic treatment is acceptable. Our pre-settling basin deviates from the drainage manual's recommendation for a 3.1 length to width ratio. Mulching and seeding per the permanent erosion control notes were intended for the water quality treatment cell. Per #11 above and #15 below, Envirotech will revise plans, if necessary to incorporate drainage guidance. 13.The catch basin is mis-labeled, and should be called out as a spill control separator. The pipe tee in the catch basin was designed as an added defense prior to runoff entering the basic treatment. 14.The construction sequence recommendations per our design must be implemented, and Envirotech should be retained to perform inspections and as-builts per permit requirements. 15.Without further cornments from Mason County, we will provide additional design plans per the County stormwater management plan cornments separate from this letter. f Please call Michael Staten at 360-275-93741 if you have any questions regarding this letter. Best Regards, Envirotech Engineering AFL CLYDe Sr �`LQ► of a""kisy, ,q�F Ti`' r 2 f � 40G� R 43045 SIF r VAL�+1�, 10/8/16 Michael Staten Project Director (�WVO - z c - )re.C 2 I -� O1� raj : / y��� I � i I : I , --1 _ ; --- -br om l � 1 I ". olloo i t L �aUE.— �w �s �oc¢.� MASON COUNTY DEPARTMENT of PUBLIC WORKS 100 W PUBLIC WORKS DRIVE N SHELTON, WASHINGTON 98584 MEMORANDUM TO: Kell McAboy Department of Community Development FROM: Cc Loretta Swanson, Technical Services Manager Cc: 1 Tricia Woolett, Building Inspector/Permit Specialist DATE: August 11, 2016 SUBJECT: COM2015-00013 This memo is in response to citizen concerns regarding stormwater management for the new church located off State Route 300 for Iglesia Asemblea de Dios. The concerns as I understand them are as follows: 1. Site conditions are different from those identified in the stormwater plan, for example the pre-developed condition assumes the entire site drains towards the southwest property corner and a 10-foot clearing limit was established for tree preservation and erosion control; 2. The stormwater plan (and on-site septic system location)do not take into account well locations and aquifer recharge; and 3. The stormwater plan sheets appear to have a smaller sized pond than the calculations would indicate. recently reviewed the drainage report, CSWPPP, and plan sheets prepared by Envirotech Engineering (after the fact), and Hearings Examiner Findings, Conclusion and Decision. I also performed a field site visit. Based on those reviews and site visit, Public Works requests that a certificate of occupancy permit not be issued until the applicant's engineer has responded to the attached letter and Public Works has signed off on the final installation of stormwater facilities. Thank you. Attachment: Letter to Envirotech Engineering Page 1 of 1 MASON COUNTY DEPARTMENT OF PUBLIC WORKS 100 W PUBLIC WORKS DRIVE SHELTON, WASHINGTON 98584 Phone(360)427-9670 x450 Fax(360)427-7753 August 15, 2016 MASON COUNTY MISSION Mr. Michael Staten, PE The mission of Mason Envirotech Engineering County Government is to PO Box 984 provide essential& I mandated services which I Belfair, WA 98528 will preserve & benefit the health,safety,&welfare of the general public in a Re: lglesia Asemblea de Dios,COM2015-00013 professional and courteous manner through the effective and equitable management Dear Mr. Staten: of available public resources. y This letter is in response to concerns raised about stormwater management for the Mason County recognizes I new church off State Route 300. Mason County typically does not perform an that its employees& independent plan review or inspections but relies on the engineer of record to volunteers are the foundation upon which ensure drainage standards are met and the system is installed as designed. these services are provided. However, Public Works will follow up if concerns are raised. The concerns regarding i this project as I understand them are as follows: I • Site conditions are different from those identified in the stormwater plan; i ■ The stormwater plan sheets appear to have a smaller sized pond than the - { calculations would indicate; and } The stormwater plans (and on-site septic system location)do not take into account well locations and aquifer recharge. I recently reviewed the construction stormwater pollution prevention plan (CSWPPP), drainage report,and plan sheets prepared by Envirotech dated September 2013 and received by the Department of Community Development in February 2015 and made a site visit. I also reviewed the Hearings Examiner Findings, Conclusions and Decision of June 2013. Based on the reviews and site visit, I have the following questions and comments: CSWPPP 1. Page 4/7 1.0 Mark Clearing Limits The plans indicate a 10-foot tree buffer is to be maintained along Gladwin Road. The Hearings Examiner record indicates the applicant planned to retain as many trees and vegetation as possible. However, it appears that several large fir trees were removed from the buffer and it is unknown whether the buffer was ever clearly marked. Page 1 of 5 �j i Mr.Michael Staten,PE August 15,2016 Page 2 2. Page 4/7 2.0 Establish Construction Entrance There are presently two accesses to the site:one off State Route 300 and another off Gladwin near the intersection with SR 300. According to Public Works records,the Gladwin access has never been permitted and has not been stabilized according to the plans. This access may only be used temporarily during construction and if stabilized per plans. It must be removed prior to issuing a final occupancy permit. 3. Page 4/7 3.0 Control Flow Rates How will flows be controlled in the vicinity of the Gladwin Road temporary construction access and drainfield location? It appears that runoff will simply flow down the access,across Gladwin and onto the downslope property. Please identify how these flows will be managed. 4. Page 4/7 4.0 Install Sediment Controls Much of the natural site vegetation has been removed and no silt fence has been installed to date. It is unknown if the temporary sediment pond has been constructed. There are no measures in place at this time to prevent silt and sediment-laden runoff from leaving the property during a rain event. The owner and contractor should be prepared for this situation. 5. Page 5/7 5.0 Stabilize Soils - Soil stabilization was not apparent and the owner contractor should be preparing for the upcoming wet season. 6. . Page 5/7 6.0 Protect Slopes As noted above, much of the natural vegetation has been removed and slope stabilization has not yet occurred. Drainage Repo �' P 7. Page 2 2.2 Surface Drainage The report states that"...a significant amount may enter through the natural Swale along the west property line." This is where the stormwater pond is located. How will run-on be captured and routed around the pond? 8. Page 3 3.0 INFILTRATION RATES/SOILS REPORTS The stormwater management facilities are designed based on an infiltration rate determined by USDA Textural Classification. The report does not describe test pits but plan sheet 1f 3 indicates . five test pits were located on site. Were any in-situ field measurements performed? Was-any mottling noted? The pits did not extend to the depth of the proposed pond floor elevation. is there any reason to believe there may be fine silt, clay or other layer that would reduce the infiltration rate? Given the use of a low correction factor and uncertainties, at a minimum, an Operation and Maintenance Plan must be prepared and an O&M Agreement recorded prior to occupancy. Page 2 of 5 Mr.Michael Staten,PE August 15,2016 . Page 3 _.. 9. Page 4 4.3 Drainage Tributary to and Beyond the Project—Downstream Analysis This seems to contradict what is stated-in 7.above. Is the amount of surface water entering the site sign flcant or negligible? A small portion of the north-:east property corner where the drain field is located will drain off--site through the temporary access to Gladwin Road. The pre- developed condition was woodland and it is now bare dirt..How will runoff be managed in this corner of the property? 10.:Page A 4.4 Wells=Septics—Aquifers The proposed infiltration pond is approximately 200.feet northeast of.and.below the nearest on- Mapping system, Mapping does not indicate there.is a critical..aquferrecharge areas near the site: However 1th6ee are private wells and community water systems with.yvellhead protection zones nearby, .The proposed infiltration facility appears to be Just upgradient of the 5-year time . of travel tone and within the 10-year time oftravel zone for the Lynch Cove Divisian.l Water. Association. It also appears to be within 1000 feet of the Group 8 R{dgerunner water.system'. Please describe horn the infiltration facilities comply with state:Department of stealth wellhead protection program requirements, :. • 11.;Ra je 6.'.i.Developed Condition Basin The table.describing land use acreages under existing and developed conditions does not match the`:model inputs for mitigated land use. The table.indicates 2.41 developed acres are irrmperv{ous but 1.75 acres are modeled. The table also indicates 1.75 developed acres are . woodland young second growth,but 2.41 acres are modeled as f6rest..J1.69 acres and pasture. (0:72 acresj. i'lease adjust to reflect the correct acreage, Additional{y,chiaracterizingthe developed pervious as forest and pasture will likely over-represent the amount of infiltration occurring: Isn't lawn a more accurate description partkuiady given the extensive vegetation removal from the.site? Or,will soil amendment and native plantings be installed? 12. Pages 6,7 5.1 Infiltration Pond with Water Quality Cell Runoff Treatment: It appears that basic treatment{s provided and the narrative does not describe the treatment facility selection process. Please describe the treatment selection process.and why basic treatment only is appropriate. The plans include a pre-settling basin presumably designed to pretreat runoff from the new building and parking lots before flowing into the infiltration pond. The pre-settling basin does not appear to meet the length to width ratio that will allow good settlement to occur. It also does not have a treatment liner specified. Given the soils and location within the wellhead protection area it seems that a liner or soil amendment to reduce the infiltration rate.is needed.. Please revise the plans to show the correct dimensions and provide liner or soil amendment specifications. Please note this will change the infiltration rate and likely require upsking the pre-settling basin. What is the volume necessary for the pre-settling basin? Paue 3 of 5 I Mr.Michael Staten, PE August 15,2016 Page 4 Flow Control: The narrative describes the use of the model and results, but the project report data, narrative in 5.2 and the plan sheets do not track. It appears that after subtracting the pre-settling volume the combined volume of cells 1 and 2 on the plan sheets are at least one half the calculated volume. Please show how the calculations,narrative and plans are consistent with each other.. 13. Page 7 5.3 Catch Basin A pipe tee typically is not an effective way to provide oil/water separation unless an elbow is installed. The detail shown on page 3/3 is better described as a spill control separator and is not' used for treatment purposes, but for temporarily trapping small volumes of oil. 14. Page 8 6.0 Construction Sequence The construction sequence recommendations and procedure need to be implemented. The commercial permit conditions state that the engineer of record or authorized representative is to perform inspections to ensure the plan is implemented as designed. An as-built needs to be submitted to the Department of Community Development prior to occupancy. Stormwater Management Plans 15. Sheet 1/3 last revised 10/27/2014 , ■ Please provide a detail for the berm and weir placed between cell 1 and 2. What I's the berm elevation and dimensions%elevation of the weir and weir notch? ■ Please provide a detail for the emergency overflow. - - Please provide inlet debris barrier detail and any scour control measures to be installed. ■ Please provide hydraulic profile(s) on the pond cross section to represent design criteria conditions. i ■ Please provide surrounding topography information on the pond cross section. Is it all cut or is any portion of cell 2 fill'? i ■ Please.provide more detail on the pre-settling basin to demonstrate how it meets design standards,particularly 3:1 length to width ratio and liner specifications. ■ Please provide more detail on the infiltration cell to demonstrate how it meets design r standards. Is this cell to be seeded? Is soil amendment necessary? Sheet2/3 dated 9/19/2013 ■ The plans show a temporary sediment pond located where the permanent ponds will be constructed and a stockpile in the same area. How will infiltration capacity be protected for the permanent stormwater ponds? There is no conveyance along Gladwin(ditch)as shown on the plans. How will runoff be managed particularly from the drainfield vicinity? Sheet3/3 dated 9/19/2013 ■ Please provide the details requested above under sheet 1/3 notes. I f Page 4 of 5 Mr.Mithae)Staten;PE August 15,2016 Page 5 Thank you in advance for addressing these comments and please to contact me if you have.any questions. Sincerely, •. • - �� `ash � �• • : _ - . . .- . Loretta Swanson Technical Services Manager. Cc: . Department bf Community Development Asemblea de Dios International Agua Viva Page 5 of 5 360-427-967004 305 MASON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT PLANNING DIVISION -F-e. BON-Q79, Shelton, WA 98584 ALL PERSONS ARE HEREBY ORDERED TO AT ONCE TOP WORK VkJ On These Premises at 3�D 6`? Vl �_r0 This order is issued because ( I K� .J���/` 4ry NA P A.M. ?L,o-Ll2-J.,q&-7ox 3195 Posted l"- - � q /,ZLC I I co By h �^ The failure to stop work, the resuming of work without permission from the WARNING Department of Community Development,or the removal,mutilation,destruc- tion or concealment of this Notice is punishable by fine and imprisonment.