HomeMy WebLinkAboutCOM2015-00013 Final Chruch, Parking Area and Stormwater Features - COM Permit / Conditions - 8/11/2017 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line (360)427-7262
PSo co�HTt Phone: (360)427-9670, ext. 352
Mason County Bldg. III
426 W. Cedar
Shelton, WA 98584
lR34
COMMERCIAL BUILDING PERMIT COM2015-00013
OWNER: ASAMBLEA DE DIOS INTERNACIONAL RECEIVED: 2/2/2015
CONTRACTOR: SOUTH SHORE CONSTRUCTION southshore@q.com LICENSE: SOUTHSCO16NL EXP: 2/10/2C ISSUED: 5/7/2015
SITE ADDRESS: 2221 NE STATE ROUTE 300 BELFAIR EXPIRES: 11/7/2015
PARCEL NUMBER: 123313200040
LEGAL DESCRIPTION: TR 4 OF GOUT LOTS 3-4
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
NEW CHURCH BUILDING AND ASSOCIATED PARKING TAKE ST RT 3 NORTH TOWARD BELFAIR, TURN LEFT ONTO WA-300 W,
AREA& STORMWATER FEATURES. TAKE THE 1 ST LEFT TO STAY ON WA-300W, SITE ON THE LEFT
General Information Construction&Occupancy Information
Type of Use: COMMERCIAL Insp.Area: No. of Units: Type of Constr.: VB
Type of Work: NEW Fire Dist.: 2 No.of Bathrooms: 4 Occ. Group: A-3
Valuation: $ 1,467,472.58 No. of Stories: 2 Exit Design. Load: 600
Building Height: 33
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building: 6,196
Year: Serial No.: Basement: 1,650 Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: E 25.00 Ft. Shoreline: Ft.
Rear: W 25.00 Ft. Slope: Ft. Water Body: Shoreline Desig.: Not Applicable
Side 1: N 120.00 Ft. SEPA?:No Comp. Plan Desig.: Rural
Side 2: S 185.00 Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Y Standpipe?:
Auto Fire Sprinkler System?: Y NFPA 13 Access Road?: Y Fire Extinguishers?: Y
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?: Y
COM2015-00013 Please refer to the following pages for conditions of this permit. Page 1 of 9
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Hosebibs 1 Exhaust Hood 1 Plan Check Fee 1RN 9l9nniu �a 7ra r» g99n1rnn
Kitchen Sink 3 Heat Pump 3 Planning Review Fee JRN )l,)/7ni5 iRn nn g99n15nn
Lavatories 6 Ventilation Fan 4 IFC Plan Check Fee JRN ?l?lgni c; a?17R ni g99n1 c;nn
Water Closets (Toilets) 9 EH Plan Review JRN )1919n15 RgnS nn C99n15nn
Water Heaters 1 Planning Stormwater Rey /;Rahn 919R»n1t; oar,nn qi?nirnn
Building State Fee RTR r,/5/7ni5 Pd 5n C1gn15nn
Building Permit Fee RTR 5/519n15 !t7 11R Q5 C19ni1;nn
Mechanical Permit Fee RTR 5/517n15 Mini An R1gni5nn
Mechanical Base Fee RTR F/Fl7ni F 1 qR Fn g19n1 rnn
Plumbing Permit Fee RTR F/S/7n15 M71 5n gi9n1rnn
Plumbing Base Fee RTR 5/519n15 (49a 7n C17ni rnn
Total $15,573.98
CASE NOTES FOR
COM2015-00013
CONDITIONS FOR
COM2015-00013
1) Final approval on SWG2013-00139 must have final approval of installation prior to temporary/final occupancy.
X
2) Approv d per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
3) All construction and demolition debris must be removed from the shore area after project completion. Proper disposal of construction debris must
be on land in such a manner that debris cannot enter or cause water quality degradation of State waters. X
4) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type
of erosion protection (silt fencing, surface matting, or straw). X �,`'� ,L 1
5) Parking shall be sufficient for 72 standard parking stalls (9 feet by 26 et) and 5 handicap parking stalls (12.5 feet by 20 feet)with sufficient
maneuvering aisles-, additional 40 parking stalls provided for larger events. Handicap stalls shall be of a smooth surface at level or ramped to
entry, located closest to the building entry and shall be signed with the International Symbol of Access. Screening from adjacent residential
properties is required. X \,! '' 1
6) All surface water and potential Hoff from the proposed development will be controlled on site and shall not adversely affect any adjacent
properties, cause sediment deposits, nor increase the velocity flow entering or abutting to any state or county culvert or ditch system or road way.
COM2015-00013 Page 2 of 9
7) Compliance with an approved Storm Water Plan shall be subject to an on site inspection, or inspections, by the engineer of record or an
authorized representative. Said inspection(s) shall be performed in accordance with the approved plan, and prior to any modification that would
make a determination of compliance impossible.
Inspection reports shall be submitted to verify all engineering requirements have been completed in accordance with the approved storm water
plan. Reports shall be submitted to the Mason County Department of Community Development prior to each corresponding inspection and final
permit epprpval Copies of all special inspection reports shall be made available at time of inspection.
8) All pro erty lines shall be clearly identified at the time of foundation inspection. X ( �
9) Landings and stairs must meet the same setback conditions as any permitted structure, and, must be shown on your site plan. Please check your
"Approved Site,Plan"to ensure these structures are shown and meet the setback conditions listed.
X 7
10) By define propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan" to
ensure these structures meet the setback conditions listed.
X ���
11) Retainin� alls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and
approval prior to construction of the retaining wall. X
12) All other necessary permits from Mason County, Washin n State and/or Federal Agencies that are required for this proposed development and
construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X
13) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept abor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-0982 Th erson signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X ' '1 1.
14) All approved plans are re ed to be on-site for inspection purposes. If inspection is called for and plans are not on site, Approval WILL NOT be
granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour w I be,charged and collected by the Mason County
Building Department prior to any further inspections being performed or approvals granted. X
15) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title
14.28.
X ���
ved site plan is required to be on-site for inspection purposes. If inspection is called for and the site plan is not on site, Approval WILL
16) The ap�pr4
NOT be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and collected by the Mason
County B ildin Department prior to any further inspections being performed or approvals granted.
17) A concre ncased grounding electrode must be installed and used at each new building or structure that is built upon a permanent concrete
foundation. In Mason County the electrical code is regulated by Washington State Department of Labor& Industries (L&I).
information. In Olympia call 360 902-6350 and in Bremerton call 360 415-4000.
For more information contact L&I for additional ( ) ( )
X
COM2015-00013 Page 3 of 9
18) 3000 PSI CONCRETE WILL REQUIRE SPECIAL INSPECTION IF THE QUANTITY EXCEEDS 50 CUBIC YARDS< LESSER AMOUNTS WILL
REQUIRE AN APPROVED CONCRETE SUPPLIER TO PROVIDE YOU WITH A BATPH TICKET THAT WILL BE REQUIRED TO BE SUBMITTED
TO THE SITE INSPECTOR FOR THE VERIFICATION OF MATERIAL USED. X
19) Structural observation shall be performed and structural observation report(s) shall repared in accordance with Section 1704.5 of the current
International Building Code. Structural observation is the visual observation of the structural system by a registered design professional for general
conformance to the approved construction documents.
Report(s) shall be provided to the Mason County Building Department at 426 West Cedar street, Shelton, WA 98584.
Reports shall be submitted to the Mason County Building Department prior to framing inspection. A final observation report shall be submitted prior
to the final inspection of the structure. Written statements shall indicate the permit number, type of inspection, and identify any reported
deficien ies.,
X �.
20) In addition to the inspections required in IBC, Section 109, the owner, the engineer or architect of record acting as the owner's agent shall employ
one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by
the design professional. The special inspectors duties & responsibilities shall be as specified in Chapter 17.
1.) Field welding must be performed by a W.A.B.O. certified welder.
2.)A325 High strength bolts.
Special inspection reports shall be submitted to the Mason County Building Department, PO Box 279, Shelton WA 98584 and available for
inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and
final oc inspections.
X
21) Any ch nges in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to
construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are
removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and
collecked by the Mason County Building Department prior to any further inspections being performed or approvals granted.
X
22) ALL ONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY
IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF PSE OR OCCUPANCY WOULD RESULT IN PERMIT
REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x
23) Provisions for surface/subsurface drainage control must be implemented with new con ction or development on site and MUST NOT adversely
impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements
of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose.
For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a
driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450.
For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review
future planned wQrk which,may affect your project.
X�,
24) Changes to a�fbved building plans that affect compliance to the current Washington State Energy Code (WSEC), ventilation requirements),
Buildin /Plu �i /Mechanical Codes and/or Mason County Regulations shall be approved prior to construction.
X
COM2015-00013 Page 4 of 9
25) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE
ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in
conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a
Mason County uilding Inspector shall be made prior to requesting additional inspections.
X
r-•
26) All bui w g permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-com liant with ),Mason County ordinances and building regulations.
X
27) All per s expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the
time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control
of the per it 0911er have prevented action from being taken. No more than one extension may be granted.
X 1
28) PressL[e1reated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal
fastene s, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
X
29) ACC IBLITY EXCEPTION:
Each toilet and bathing room shall be designed and constructed to be accessible to persons with disabilities in accordance with the 2012
International Code and ICC A117.1. Referencing IBC Section 1109 the following exception applies. All elements listed shall apply to qualify for the
exception.
EXCEPTION:
In toilet rooms or bathing rooms accessed only through a PRIVATE OFFICE, not for common or public use, and intended for use by a single
occupant, the following alternatives are allowed:
1) Doors are permitted to swing into the clear floor space, provided the door swing can be reversed to meet the requirements in ICC A117.1;
2)The height requirements for the water closer in ICC A117.1 are not applicable;
3) Grab bars are not required to be installed in a toilet room, provided the reinforcement has been installed in the walls and located so as to
permittee installation of grab bars; and
4)The r guir ent for height, knee and toe clearance shall not apply to a lavatory.
X i �
30) COMMERCIAL KITCHEN HOOD:
All commercial kitchen hood systems shall be protected with a UL300 compliant automatic fire extinguishing system installed in accordance with
manufacturer specifications and maintained as required by the 2012 International Fire Code, Building Code, and International Mechanical Code.
The system shall be inspected and tested for proper operation at 6-month intervals unless approved otherwise. Maintenance records shall be
available for inspectors during inspections.
As per IMC table 507.2.2 as amended by Washington State the minimum hood required for a church that will be boiling, steaming, and warming
precookeed only is a type II hood.
X
COM2015-00013 Page 5 of 9
31) FIRE EXTINGUISHERS:
Install 2A10BC fire extinguishers throughout the building in accordance with chapter 9 of the 2012 International Fire code. The fire extinguishers
shall be installed such that the extinguishers are located not more than a travel distance of 75 feet in any direction and mounted no more than 60
inches above floor to the top of the unit. At least one extinguisher is required on every level or floor.
Not less than 1 type K portable fire extinguisher shall be located in the commercial kitchen area, within 30 feet of the cooking appliances and no
closer than 10 f et.
X
KEY B REQUIRED:
A key box/knox box is required to be installed in accordance with the 2012 International Fire Code Section 506. Please contact the local fire
district for mor information and to discuss inspections for installation of the lock box system.
X
32) ADDRES ONDITION
Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title
14.28.
Commercial structure mile point number or unit designation posting requirements:
50 feet or less setback shall post a 6 inch minimum with a 3/ inch stroke.
50 feet or more setback shall post a 12 inch minimum with a 1 'h inch stroke.
Designating unit on a building will be no less than 6 inches in height with minimum 3/ inch stroke.
Designating unit on a door will be no less than 4 inches in height with minimum '/2 inch stroke 100 foot setback or less shall post 18 inch minimum
with 2 inch stroke.
100 fgot sk or greater shall post 24 inch minimum with 3 inch stroke.
Xl
33) POS CCUPANT LOAD
Every room or space that is an assembly occupancy, such as a restaurant, bar, or meeting room, shall have the occupant load of the room or
space posted in a conspicuous place, near the main exit or exit access doorway from the room or space. Posted signs shall be of an approved
legible p rmaperlt design and shall be maintained by the owner or agent. (IBC1004.3)
X
34) EXITS IT ACCESS DOORS
All doors shall be side hinged and swing in the direction of exit travel. All exit doors shall be illuminated at all times that the building is occupied and
be equipped with approved accessible hardware that does not require tight grasping, tight pinching or twisting of the wrist to operate.
ALL exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. All exit signs shall be
intern Ily or externally illuminated at all times and equipped with to ensure continued illumination for a duration of at least 90-minutes.
X /I
COM2015-00013 Page 6 of 9
35) 2012 IECC/WSEC COMPLIANCE:
This project is approved for compliance to the 2012 International Energy Conservation Code/Washington State Energy Code (IECC/WSEC);
components shall be installed as follows:
ENVELOPE: Prescriptive Using Table C402.2
Roof: Metal building with R3.5 thermal blocks, R-11 liner system PLUS R25 continuous non-compressed insulation
Wall insulation min R13 continuous insulation + R-13 wall insulation or better,
Slab insulation R-10 or better installed in around the entire perimeter from the top of the slab edge to the bottom of the footing.
Fenestration including doors and windows, including store door(s) shall have a U-Factor as follows-fixed/non operable windows .38 and operable
windows U-0.40or less, entrance doors U0.60 or less and skylights U-0.50 or less. Solar heat gain coefficient(SHGC) 0.40 or better except
skylights SHGC 0.35 or better.
OTHER DOORS: Other than entry doors U-0.37 or less and roll-up or sliding doors min. R-4.75.
DEFERRED SUBMITTAL IS APPROVED FOR ELECTRICAL POWER AND LIGHTING SYSTEMS and the MECHANICAL SYSTEM.
COMPLIANCE INFORMATION SHALL BE SUBMITTED TO THE MASON COUNTY BUILDING DEPARTMENT AND APPROVAL OBTAINED
BEFORE THE FRAMING INSPECTION.
THE FRAMING INSPECTION WILL NOT BE APPROVED UNTIL DEFERRED SUBMITTAL DOCUMENTS ARE APPROVED AND ISSUED BY
THE MASON COUNTY BUILDING DEPARTMENT.
LIGHTING: DEFERRED SUBMITTAL
Total interior lighting shall not exceed 4637 watts, or provide a design calculation demonstrating compliance to IECC/WSEC C405. Lamp wattage
shall be calculated using the lamp and ballast or for incandescent fixtures, using the maximum labeled wattage allowed and is approved as follows:
Provide a lighting plan showing the layout of all lights and controls along with a schedule that identifies the wattage for ballast and lamps. The plan
and information shall be submitted to the Mason County Building Department for review and approval prior to the framing inspection.
All daylight zones shall be provided separate control in accordance with IECCWSEC. Automatic daylight sensing controls shall be capable of
reducing light out put, that control luminaries only within the day lighted area, shall be clearly identified. Switches shall be equipped with separate
automatic controls to shut off the lighting in all spaces during unoccupied hours. Occupancy sensors shall be capable of automatically turning off
all lights in an area in accordance with IECC/WSEC.
Exterior lighting shall not exceed 750 watts or provide a design calculation demonstrating compliance to IECC/WSEC C405 or as otherwise
allowed in the IECC/WSEC. A lighting plan and summary shall be submitted to the Mason County Building Dept. for review and approval prior to
the framing inspection.
MECHANICAL SYSTEM: DEFERRED SUBMITTAL
A mechanical plan was not included with the plans submitted for approval. Deferred submittal shall include compliance forms attached to the
approved construction plans, details and information about equipment and system, along with plans demonstrating compliance to IECC/WSEC
C403. Mechanical systems and equipment serving heating, cooling, ventilating, and other needs with Section C403.2 and either C403.3 or C403.4.
Walk-in coolers and walk-in freezers shall comply with C403.5. Refrigerated warehouse coolers and refrigerated warehouse freezers shall comply
with C403.6.
COM2015-00013 Page 7 of 9
MECHANICAL SYSTEM - NON RESIDENTIAL:
Those parts of the mechanical system that are altered or replaced shall comply with Section C403 of the 2012 International Energy Conservation
Code as amended by Washington State (IECC/WSEC), ref C101.4.3.2.
Heating and cooling loads shall be determined. The out put capacity of heating and cooling equipment shall not exceed the load calculated. Heat
and cooling load calculations shall be provided on site for inspection.
HVAC equipment shall meet or exceed the minimum efficiency requirements specified in section C403.2.3 and applicable tables.
Unless approved otherwise:
HSPF rating (heating) shall be 7.7 or better, 3.3 C.O.P or better, and SEER rating (cooling) shall be 13.0 or better
Warm air gas fired furnaces shall have an A.F.U.E rating of 78% or better.
Com ian a inf rmation shall be provided on site for inspection.
X
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
ign re Date
1( LI r L/ OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate) --
COM2015-00013 Page 8 of 9
:e
V�a3�
r'
uU
i
i
NVld 1t211LLo311HOLIV C3W NV Z
ll/�IO N33(iLL39 31VNIoai0011 Ol 31919NOd93Zi
91 61010VM1N00 '9NOI-W Ol aNV 9N019N34o / I ,
3aVAOLtW Ol NV-W 3119 1VaR1�311HZNV'NV 91 91H1 O/ /
'310N / I , I =
M3N ON'9VNINVld 3dV'�aWl CrajrA a33(p
a32/1(lo3al 93aINOWl J NOUV130dA x-N1191X3 3213MI11 / 'I �I, 1 I (D
(D
1310N
00V33a119 A.21019 213ow1(1)
slo wa a 9i'�16�3d11wo.i
/ \
,00v933a11 Ad0NVO(4) / I'
'9VNI1NV'ld'NW E�Wf110ll0d 3Hl Hll1f1 301f11,G:
V 3dAl OWVA bla* 1e 3dV09aNVl
uollualaa i41
Q
lelemwiolg t
1 I ( 'a,0 V I /
. d9
ltnlo al3d
NOI1N313a
d1130Vd9 Vd
'993ooV'V3•V 361 Nhl9
1VwuorwlQ al3d-17vm wV13a1 \ �!
0,
Gairlow
3191993o0V Ow 3a it i9 Noi fJ \
I'IV-H9'Nv-u 3119 V1N3 339 / \ OOIL m:1 \
in
3NVl3aild \
dAl awl �3s�ruallna,aL N
dAl awl A1LI3d021d 1 \ A 9r10(1Qlo3o rH.P0.1Vh L
a 3dA1 wig ?Z , 9(IOf1Qlo3 H H(9
/ ,001/93iaLL A210182134Nf1!L)
QW31-110 Afl NvI93a \ "�• ' \ r / / dWn10 W319-I11114'H,9
! ` •` \ �� 210 W319 31V119 N3dI1VO,.L
W319A9 olld39 338 ^��\ ` \ \ / < ! -0OV33211 AdONVO(I)
'9'7w1NVld WIIWINIW vNIM011Od
Be 3Hl HIM 301M;01
(3WVA NB=6 Q 3dVO9aNV1
dAl 3NIl OmIVA Wa;j; 1S7 3dV094NV1
'dAl 3w1 4002i
993OOV 990%0V a3J02AIIW Be aNV
I .^�` •��` �� , i7NV�I1N3 A9 a3d(10LIO 39'9NJV1 OIld39
CWAVI Ol 1Nv-W AlNO 9NOUVOOl 393H1
-a3a1319m1 99r%wH9 oa1VA Namu1O
dw
I ,
1 ,
i
n � rn C3 co
rn
m.: �G m
•vr / 0 m.
-+ W S
o d C m..
( � C: '
W r= Cnch .
Q
C
0z
< z
fn
z •.
UV
o ,
0 ' •��
. I
31RIVE c\ .... .
IEbg AREA
rrri r, SEE SEPTIC SY
DESIGN BY OTI
' '• _! .•/ � ir1.I fry([� \ / / `\ ,..
` SIGN TYPE B
t
PROPERTY L IN
-mg
0 81
/ WISHFIRE.LANE
04t" `t FINISNEk�' � ``, / SEE ENLAI's
/ r FOR SIDEWA
t} d, , ,FF 2100
FF`33 ROUTES tY
RETAIN[ WALI
,r41 .A
SIGN T PE
PA SPAC
SP �
JJ /
o
- `�. I Storrriwater
o .M. D L Detention
T ca
v c ,
�o
LANDSCAPE BUFFER YARD TYPE A-
I
/ 5' WIDE WITH THE FOLLOWING MIN. PLA
(b)CANOPY TREES/100!
/ 2" CALIPER, SINGLE STEM-OR
m I I r S' H.MULTI-STEM CLUMP,
Q7
�1 (I) UNDER STORY STREE/100'
m _ I // r V.H. DECIDUOUS,
o NOT�1 E:
�+ / WHERE EXISTING VEGETATION PROYI
I. BUFFER YARD LANDSCAPE PLANTING
LANDSCAPING REAUIREp
/, ! NOTE:
/ THIS IS AN ARCHITECTURAL 84 PL
DIMENSIONS AND LOCATIONS. CON
1 RESPONSIBLE TO COORDINATE BE
` PLAN AND ARCHITECTURAL
PLAN.
MASON GOUNTYI Permit No:yp)a 015.owl i
L DEPARTMENT OF CObIMUNITY DEVELOPMENT
BUILDING•PLANNING•FRREMARSHAL (360)427-9670 Shelton ext.352
http:/Avww,co.mason.wa.us/community dev/ (360)275-4467 Belfair ext.352
s, 426 W Cedar Street,Shelton WA 98584 (360)482-5269 Elma ext.352
BUILDING PERMIT APPLICATION RECEIVED
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: NAME: c�ti F E B 0 2 2015
MAIL G ADDRESS: � ( MAII. G ADDRESS: C
CITY: STATE. ZIP: Cny STATE:.ZIP: 426 W, CEDAR S T.
PHONE CELL: PHO CELL:
EMAIL: EMAIL
L&I REG# EAR 1 /10/ t
• CONTACT: OWNER❑ CONTRACTOR BELOW❑
NAME: MAILING ADDRESS: O. x BUILDING
CITY: STATE: ZIP: PHONE: CELL: 0 )
EMAIL:
ft=' ye&q
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER) 3 2-000`f O FIRE DISTRICT
LEGAL DESCRIPTION(ABBREVIATED): -M i 01= F o VT L01-c� '�-t- S 3q 12 S7
SITE ADDRESS 2221 NE St7til= IzyATr- 300 CITY VELPAIP-
DIRECTIONS TO SITE ADDRESS 1 f T o TU N O --TM:;F
000. SIT$ Is �T• "
IS PROPERTY 7MMM 200 FT:
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ :
DOES PROPERTY HAVE SLOPE(S)WITHIN 300 FT OF THE PROJECT-GREATER THAN I^ YES❑ NO 4V
TYPE OF JOB: NEW S ADDITION ❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE IDINCE,GARAGE ETC.)
IS USE: PRIMARY K SEASONAL❑ NUMBER OF BEDROOMS n JCk NUMBER OF BATHROOMS__
DESCRIBE WORK
SOUARE FOOTAGE:
1ST FLOOR.Ja sq.ft 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENTL(60 N.S
DECK sq.ft. COVERED DECK sq.R STORAGE sq.it. OTHER sq.ft.
GARAGE sq.R ATTACHED❑ DETACHED❑ CARPORT sq.ft. ATTACHED❑ DETACHED❑
MANUFACTURED INFORMATI •4 COPIES OF THE FLOOR PLAN REQUIRED
MAKE DEL YEAR GTH
WID BE BATH SERIAL NTOaWR
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner or owner's legal representative.I further
declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the
necessary parties,including any easement holder or parties of interest regarding this project The owner or legal 5
representative,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure(s)for review and inspection.This permit/application becomes null&void if
work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42)
x 'e-2t � 212-115
Signature of OWNER Date
DEPARTMENTAL REVIEW APPROVE DA DENIED DATE TAGS/NOTES/CONDMONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
FEES TOTALfd'e1LUATION:.
BUILDING PERMIT FEE FME ACCESS AND GRADE
PLAN REVIEW GEO-TECH REVIEW
PLUMBING&BASE FEE STORMWATER REVIEW
MECHANICAL 8c BASE FEE I TOTAL FEES
WOOD/GAS/PELLET STOVE VIOLATION INVESTIGATION FEE
PLANNING REVIEW FEE VIOLATION FEE
r6 cot, MASON COUNTY' BUILDING PERMIT NO. aO�S-
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING•PLANNING•FIRE MARSHAL
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352
Mason County Bldg. III,426 West Cedar Street (360)275-4467 Belfair ext. 352
185 PO Box 279, Shelton,WA 98584 (360)482-5269 Elma ext. 352
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: m NAME: U
MAILING ADDRESS: �) v' I in. MAILING ADDRESS: b
CITY: Ibi If7A i y STATE:VVA ZIP: 99Z CITY: Y STATE: ZIP:
PHONE:3(L D =115-Q18 CELL: 31p0 -Jj 09-(3 L12 PHONE: -Z -0$t3 CELL: -izu,
EMAIL:_ A EMAIL : , O
L&I REG# UN L EXP.-Z U /A-0
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER): 2�3J - 22 'D0010
LEGAL DESCRIPTION(ABBREVIATED): T47- + 0E- (M VT LptZ 3--I- S �q 2 27
SITE ADDRESS: 2221 N E sJJ'(t-- 4?-ouTa a D O CITY: I R-
DIRECTIONS TO SITE ADDRESS: t WAV IN tr- N off- i ON tJ W ye �i,�-U. -N LF7' nN s 7 g-DUJr--
Sa-F— IsDN L4--- -FT,
TYPE OF JOB
NEW)_ADD ALT REPAIR OTHER USE OF BUILDING C,,fiU fl (A -3)
LOCATION OF FIXTURES/UNITS—1 IT FLOORS_2D FLOOR BASEMENT < GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Eixtures Fees Fuel Type:Electric LPG Natural Gas Heat Pump_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heatpump
Showers Spot Vent Fan
Water Heater --T Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove E
Dishwasher Kitchen Exhaust Hood )
Hosebibs Dryer Vent FEB 0 2 2015
Other Other
Base Fee Base Fee
426 W. CEDAR ST.
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is
suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLIC IO OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X (�
47 (nryl,
gnature�ofApplic1a/nt at
X_ /��"to�P 1. Owner/Owners Representative/ ontracto
Print Name (indicate which one)
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT S
PLANNING DEPARTMENT
FIRE MARSHAL
�wv�rotech �>tig�weer�wg
Cject!3 !.V icn! ° Ev)"Ayov.w .vv�ta! °DYn:Nnpv_
October 31, 2016 RE
Mason County
JED
Department of Community Development V 02 2016
615 W Alder Street CQJNTMPU8LICW
Shelton, 9
on Washington 98584 ORKS
Asamblea De Dios Internacional Agua Viva
160 NE Santa Maria Lane
Belfair, Washington 98528
RE: Iglesia Asamblea de Dios
COM2015-00013
To Whom It May Concern:
Envirotech Engineering provided a recent letter dated October 8, 2016 (see
enclosed) addressing concerns from Mason County in a letter dated August 15,
2016. This letter further justifies our design and addresses the enclosed
resubmittal per item #15 on the aforesaid County letter.
There are a few discrepancies between our described land use areas with
relation to our stormwater modeling. However, the basis of our original infiltration
pond design utilized an impervious contribution of 1.75 acres, whereas planned
conditions are only 1.17 acres. This 50% increase is extremely conservative, and
provides a pond size adequate for this project. Envirotech reviewed our
calculations utilizing actual impervious areas with the infiltration rate reduced to
2.4 in/hr for both cells of the pond. With a reconfigured cell 1 to meet the
stormwater manual, and the reduced infiltration rate, the infiltration pond is
deemed over-sized after accounting for a 6-inch sediment storage depth and a
12-inch freeboard.
On sheet 1 of the plans, the pond has been reconfigured with a new cross
section showing all pond elements, design criteria and hydraulic profiles. This
includes general topography indicating that the pond is entirely within a cut
section.
PO BOX 8
9 4
Belfair,Washington 98528
Off: 360-275-9374
Cell: 36o-689-6045
Details for the berm, weir, emergency spillway, debris barrier, and all scour
control are provided on sheet 3 of the plans.
Temporary erosion control concerns within item #15 of the County letter have
been addressed in our previous letter.
Please call Michael Staten at 360-275-9374 if you have any questions regarding
this letter.
Best Regards,
Envirotech Engineering
AFL C LYDF ST
GX% �r7STER�
�SS�a �At F^„c �oi3 vi6
Michael Staten
Project Director
Cc: Mason County
Department of Public Works
100 W Public Works Drive
Shelton, Washington 98584
G-VWL'rotech
c,eoter'kVacaL 0 ev"V%rov�wv.ev&tal .pY.61 v.age ° Roadwau
October 8, 2016
Mason County
Department of Public Works
100 W Public Works Drive
Shelton, Washington 98584
Asamblea De Dios Internacional Agua Viva R�C���E�
160 NE Santa Maria Lane
Beifair, Washington 98528 NOV 0 2 2016
615 W. Alder Street
RE: Iglesia Asamblea de Dios
COM2015-00013
To Whom It May Concern:
Envirotech Engineering is providing this letter to address concerns from Mason
County in a letter dated August 15, 2016. We visited the project site on
September 9, 2016 in order to observe current site conditions. The following
items directly correspond to the aforesaid letter.
1. Sheet 1 of our plans depicted a 10-foot buffer (clearing limits). According
the contractor, it is our understanding that the architectural plans depict
the 10-foot buffer as vegetative landscaping. This is acceptable to
Envirotech as it should be re-vegetated.
2. Per Sheet 2 of our plans, we recommended one construction access off of
State Route 300. Temporary access from Gladwin Road should be
removed by not using, and placing temporary seeding to stabilize the area
per the drainage plan.
3. Stabilizing the Gladwin access and drainfield areas with temporary
seeding will control flow rates. It is our opinion that flow from a 2yr-24hr
construction design storm will disperse and infiltrate prior to leaving the
site. However, the stormwater plans indicates that if drainage is not
functioning as intended, additional provisions/ drainage facilities will be
required such as silt fencing.
PO BOX 984
Belfair,Washington 98528
Off: 360-275-9374
Cell: 36o-689-6045
r
4. All sediment/temporary erosion controls should be implemented per the
approved plans. This includes silt fencing as necessary and seeding
unworked denuded areas. It is our opinion that the existing pond is
sufficiently sized for the temporary 2yr-24hr storm event, and may be used
as a temporary sediment pond. Upon project completion, the temporary
pond should be enlarged per the drainage plan.
5. Soil stabilization is provided in the stormwater plans, and should be
implemented for this project. Wet season erosion control provisions are
provided in the plans, and should be completed on or before October 1st
6. Slopes must be protected per the erosion control plan. Vegetation and/ or
plastic cover, as necessary should be implemented.
7. Our initial evaluation was intended to be worst-case-scenario, and that the
natural swale on the west side of the property may possibly convey
surface water. We did not observe scour within the swale, but did notice
some erosion in the right-of-way to the north of Gladwin Road near the
swale end. It is our opinion that the established drainage conveyance
system within State Route 300 is adequate for diverting stormwater away
from the project during storm events. We believe that significant runoff that
could enter the site would most likely be from un-maintained drainage
conveyances upslope from the project or from storms exceeding the
100yr-24hr event, which are not designed for. In conclusion, it is our
opinion that the designed ponds are adequately sized for the new
development plus design storms contributing to the retention pond.
8. In-situ infiltration measurements were not performed. Based on soil type
and experience performing field infiltration tests, we believe that our
infiltration rates based on the USDA classification is much more
conservative than performing in-situ measurements. Sheet 1 of the plans
depicted soil logs for each of the five test pit excavations. No mottling was
observed. The pond test pits were observed to a depth of 8 feet, which is
0.5 feet below the final pond bottom. Envirotech recently hand excavated
to a depth of 3 feet below the bottom of the expected pond depth with no
change in materials to report. An operation and Maintenance Plan was
prepared by Envirotech during the design of this project. An O&M
agreement recording should be a condition of permit by Mason County.
9. Unless upslope drainage facilities beyond the project fail, or severe storms
occur above ordinary design storms (see #7 above), we believe runoff
entering the property is negligible. This is also substantiated by periodic
observations over the past 3 years. It is our opinion that the small portion
of the north-east property corner is not significant of an area to generate
runoff to off-site properties, especially after re-vegetating per plan. Bare
dirt areas of the property are temporary until construction is complete and
the ground is either fully developed or revegetated. Although the
revegetated areas will have a little more runoff potential than pre-existing
site conditions, the additional runoff is negated as the runoff from the
developed areas are controlled. The land area that will be developed is
not contributing runoff as it did during pre-existing conditions.
10.The drainage manual recommends that infiltration facilities are at least
100 ft setback from on-site septic components. This appears to be
adhered to. Infiltration facilities appear to comply to the State Department
of Health wellhead protection program. The proposed drainage facilities
are over 1000 feet from Lynch Cove and Ridgerunner water systems.
Furthermore, the hydrogeologic setting is acceptable for the planned
drainage systems not to contaminate any private well systems.
11 . Factoring the design storms and development areas, the proposed size of
the infiltration facility has a volume relationship similar to other
developments within the area. Envirotech will re-examine the facility
sizing, and if necessary, provide a revised pond size along with a re-
submittal per item #15 below.
12. Based on proponent provided information, the use of this project will
render an approximate average of 30 trips per day of traffic. Other than
the low volume of traffic and ordinary landscaping maintenance, other
pollution generating activities are not anticipated. From the drainage
manual (Vol V), this is not considered a high use site, and basic treatment
is acceptable. Our pre-settling basin deviates from the drainage manual's
recommendation for a 3.1 length to width ratio. Mulching and seeding per
the permanent erosion control notes were intended for the water quality
treatment cell. Per #11 above and #15 below, Envirotech will revise plans,
if necessary to incorporate drainage guidance.
13.The catch basin is mis-labeled, and should be called out as a spill control
separator. The pipe tee in the catch basin was designed as an added
defense prior to runoff entering the basic treatment.
14.The construction sequence recommendations per our design must be
implemented, and Envirotech should be retained to perform inspections
and as-builts per permit requirements.
15.Without further cornments from Mason County, we will provide additional
design plans per the County stormwater management plan cornments
separate from this letter.
f
Please call Michael Staten at 360-275-93741 if you have any questions regarding
this letter.
Best Regards,
Envirotech Engineering
AFL CLYDe Sr
�`LQ► of a""kisy, ,q�F
Ti`' r 2
f �
40G� R 43045 SIF
r
VAL�+1�, 10/8/16
Michael Staten
Project Director
(�WVO - z c - )re.C 2 I
-� O1�
raj : / y���
I �
i
I
: I ,
--1 _
;
--- -br
om
l �
1
I
". olloo
i
t
L
�aUE.— �w �s �oc¢.�
MASON COUNTY
DEPARTMENT of PUBLIC WORKS
100 W PUBLIC WORKS DRIVE
N SHELTON, WASHINGTON 98584
MEMORANDUM
TO: Kell McAboy
Department of Community Development
FROM: Cc Loretta Swanson, Technical Services Manager
Cc: 1 Tricia Woolett, Building Inspector/Permit Specialist
DATE: August 11, 2016
SUBJECT: COM2015-00013
This memo is in response to citizen concerns regarding stormwater management for the new church
located off State Route 300 for Iglesia Asemblea de Dios. The concerns as I understand them are as
follows:
1. Site conditions are different from those identified in the stormwater plan, for example the pre-developed
condition assumes the entire site drains towards the southwest property corner and a 10-foot clearing
limit was established for tree preservation and erosion control;
2. The stormwater plan (and on-site septic system location)do not take into account well locations and
aquifer recharge; and
3. The stormwater plan sheets appear to have a smaller sized pond than the calculations would indicate.
recently reviewed the drainage report, CSWPPP, and plan sheets prepared by Envirotech Engineering
(after the fact), and Hearings Examiner Findings, Conclusion and Decision. I also performed a field site
visit. Based on those reviews and site visit, Public Works requests that a certificate of occupancy permit
not be issued until the applicant's engineer has responded to the attached letter and Public Works has
signed off on the final installation of stormwater facilities.
Thank you.
Attachment: Letter to Envirotech Engineering
Page 1 of 1
MASON COUNTY
DEPARTMENT OF PUBLIC WORKS
100 W PUBLIC WORKS DRIVE
SHELTON, WASHINGTON 98584
Phone(360)427-9670 x450
Fax(360)427-7753
August 15, 2016
MASON COUNTY
MISSION
Mr. Michael Staten, PE
The mission of Mason Envirotech Engineering
County Government is to PO Box 984
provide essential& I
mandated services which I Belfair, WA 98528
will preserve & benefit the
health,safety,&welfare of
the general public in a Re: lglesia Asemblea de Dios,COM2015-00013
professional and courteous
manner through the effective
and equitable management Dear Mr. Staten:
of available public
resources. y This letter is in response to concerns raised about stormwater management for the
Mason County recognizes I new church off State Route 300. Mason County typically does not perform an
that its employees& independent plan review or inspections but relies on the engineer of record to
volunteers are the
foundation upon which ensure drainage standards are met and the system is installed as designed.
these services are provided. However, Public Works will follow up if concerns are raised. The concerns regarding
i this project as I understand them are as follows:
I
• Site conditions are different from those identified in the stormwater plan;
i
■ The stormwater plan sheets appear to have a smaller sized pond than the -
{ calculations would indicate; and
} The stormwater plans (and on-site septic system location)do not take into
account well locations and aquifer recharge.
I recently reviewed the construction stormwater pollution prevention plan
(CSWPPP), drainage report,and plan sheets prepared by Envirotech dated
September 2013 and received by the Department of Community Development in
February 2015 and made a site visit. I also reviewed the Hearings Examiner Findings,
Conclusions and Decision of June 2013. Based on the reviews and site visit, I have
the following questions and comments:
CSWPPP
1. Page 4/7 1.0 Mark Clearing Limits
The plans indicate a 10-foot tree buffer is to be maintained along Gladwin
Road. The Hearings Examiner record indicates the applicant planned to
retain as many trees and vegetation as possible. However, it appears that
several large fir trees were removed from the buffer and it is unknown
whether the buffer was ever clearly marked.
Page 1 of 5
�j
i
Mr.Michael Staten,PE
August 15,2016
Page 2
2. Page 4/7 2.0 Establish Construction Entrance
There are presently two accesses to the site:one off State Route 300 and another off Gladwin
near the intersection with SR 300. According to Public Works records,the Gladwin access has
never been permitted and has not been stabilized according to the plans. This access may only
be used temporarily during construction and if stabilized per plans. It must be removed prior to
issuing a final occupancy permit.
3. Page 4/7 3.0 Control Flow Rates
How will flows be controlled in the vicinity of the Gladwin Road temporary construction access
and drainfield location? It appears that runoff will simply flow down the access,across Gladwin
and onto the downslope property. Please identify how these flows will be managed.
4. Page 4/7 4.0 Install Sediment Controls
Much of the natural site vegetation has been removed and no silt fence has been installed to
date. It is unknown if the temporary sediment pond has been constructed. There are no
measures in place at this time to prevent silt and sediment-laden runoff from leaving the
property during a rain event. The owner and contractor should be prepared for this situation.
5. Page 5/7 5.0 Stabilize Soils -
Soil stabilization was not apparent and the owner contractor should be preparing for the
upcoming wet season.
6. . Page 5/7 6.0 Protect Slopes
As noted above, much of the natural vegetation has been removed and slope stabilization has
not yet occurred.
Drainage Repo
�' P
7. Page 2 2.2 Surface Drainage
The report states that"...a significant amount may enter through the natural Swale along the
west property line." This is where the stormwater pond is located. How will run-on be captured
and routed around the pond?
8. Page 3 3.0 INFILTRATION RATES/SOILS REPORTS
The stormwater management facilities are designed based on an infiltration rate determined by
USDA Textural Classification. The report does not describe test pits but plan sheet 1f 3 indicates .
five test pits were located on site. Were any in-situ field measurements performed? Was-any
mottling noted? The pits did not extend to the depth of the proposed pond floor elevation. is
there any reason to believe there may be fine silt, clay or other layer that would reduce the
infiltration rate? Given the use of a low correction factor and uncertainties, at a minimum, an
Operation and Maintenance Plan must be prepared and an O&M Agreement recorded prior to
occupancy.
Page 2 of 5
Mr.Michael Staten,PE
August 15,2016 .
Page 3 _..
9. Page 4 4.3 Drainage Tributary to and Beyond the Project—Downstream Analysis
This seems to contradict what is stated-in 7.above. Is the amount of surface water entering the
site sign flcant or negligible? A small portion of the north-:east property corner where the drain
field is located will drain off--site through the temporary access to Gladwin Road. The pre-
developed condition was woodland and it is now bare dirt..How will runoff be managed in this
corner of the property?
10.:Page A 4.4 Wells=Septics—Aquifers
The proposed infiltration pond is approximately 200.feet northeast of.and.below the nearest on-
Mapping system, Mapping does not indicate there.is a critical..aquferrecharge areas near the
site: However 1th6ee are private wells and community water systems with.yvellhead protection
zones nearby, .The proposed infiltration facility appears to be Just upgradient of the 5-year time .
of travel tone and within the 10-year time oftravel zone for the Lynch Cove Divisian.l Water.
Association. It also appears to be within 1000 feet of the Group 8 R{dgerunner water.system'.
Please describe horn the infiltration facilities comply with state:Department of stealth wellhead
protection program requirements, :.
•
11.;Ra je 6.'.i.Developed Condition Basin
The table.describing land use acreages under existing and developed conditions does not match
the`:model inputs for mitigated land use. The table.indicates 2.41 developed acres are
irrmperv{ous but 1.75 acres are modeled. The table also indicates 1.75 developed acres are .
woodland young second growth,but 2.41 acres are modeled as f6rest..J1.69 acres and pasture.
(0:72 acresj. i'lease adjust to reflect the correct acreage, Additional{y,chiaracterizingthe
developed pervious as forest and pasture will likely over-represent the amount of infiltration
occurring: Isn't lawn a more accurate description partkuiady given the extensive vegetation
removal from the.site? Or,will soil amendment and native plantings be installed?
12. Pages 6,7 5.1 Infiltration Pond with Water Quality Cell
Runoff Treatment:
It appears that basic treatment{s provided and the narrative does not describe the treatment
facility selection process. Please describe the treatment selection process.and why basic
treatment only is appropriate.
The plans include a pre-settling basin presumably designed to pretreat runoff from the new
building and parking lots before flowing into the infiltration pond. The pre-settling basin does
not appear to meet the length to width ratio that will allow good settlement to occur. It also
does not have a treatment liner specified. Given the soils and location within the wellhead
protection area it seems that a liner or soil amendment to reduce the infiltration rate.is needed..
Please revise the plans to show the correct dimensions and provide liner or soil amendment
specifications. Please note this will change the infiltration rate and likely require upsking the
pre-settling basin. What is the volume necessary for the pre-settling basin?
Paue 3 of 5
I
Mr.Michael Staten, PE
August 15,2016
Page 4
Flow Control:
The narrative describes the use of the model and results, but the project report data, narrative
in 5.2 and the plan sheets do not track. It appears that after subtracting the pre-settling volume
the combined volume of cells 1 and 2 on the plan sheets are at least one half the calculated
volume. Please show how the calculations,narrative and plans are consistent with each other..
13. Page 7 5.3 Catch Basin
A pipe tee typically is not an effective way to provide oil/water separation unless an elbow is
installed. The detail shown on page 3/3 is better described as a spill control separator and is not'
used for treatment purposes, but for temporarily trapping small volumes of oil.
14. Page 8 6.0 Construction Sequence
The construction sequence recommendations and procedure need to be implemented. The
commercial permit conditions state that the engineer of record or authorized representative is
to perform inspections to ensure the plan is implemented as designed. An as-built needs to be
submitted to the Department of Community Development prior to occupancy.
Stormwater Management Plans
15. Sheet 1/3 last revised 10/27/2014 ,
■ Please provide a detail for the berm and weir placed between cell 1 and 2. What I's the
berm elevation and dimensions%elevation of the weir and weir notch?
■ Please provide a detail for the emergency overflow. - -
Please provide inlet debris barrier detail and any scour control measures to be installed.
■ Please provide hydraulic profile(s) on the pond cross section to represent design criteria
conditions.
i
■ Please provide surrounding topography information on the pond cross section. Is it all
cut or is any portion of cell 2 fill'? i
■ Please.provide more detail on the pre-settling basin to demonstrate how it meets design
standards,particularly 3:1 length to width ratio and liner specifications.
■ Please provide more detail on the infiltration cell to demonstrate how it meets design r
standards. Is this cell to be seeded? Is soil amendment necessary?
Sheet2/3 dated 9/19/2013
■ The plans show a temporary sediment pond located where the permanent ponds will be
constructed and a stockpile in the same area. How will infiltration capacity be protected
for the permanent stormwater ponds?
There is no conveyance along Gladwin(ditch)as shown on the plans. How will runoff be
managed particularly from the drainfield vicinity?
Sheet3/3 dated 9/19/2013
■ Please provide the details requested above under sheet 1/3 notes. I
f
Page 4 of 5
Mr.Mithae)Staten;PE
August 15,2016
Page 5
Thank you in advance for addressing these comments and please to contact me if you have.any
questions.
Sincerely, •.
• - �� `ash � �• • : _ - . . .- .
Loretta Swanson
Technical Services Manager.
Cc: . Department bf Community Development
Asemblea de Dios International Agua Viva
Page 5 of 5
360-427-967004 305 MASON COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
PLANNING DIVISION
-F-e. BON-Q79, Shelton, WA 98584
ALL PERSONS ARE HEREBY ORDERED TO AT ONCE
TOP WORK
VkJ
On These Premises at 3�D 6`? Vl �_r0
This order is issued because ( I K� .J���/` 4ry
NA P
A.M. ?L,o-Ll2-J.,q&-7ox 3195
Posted l"- -
� q /,ZLC I I co By h �^
The failure to stop work, the resuming of work without permission from the
WARNING Department of Community Development,or the removal,mutilation,destruc-