Loading...
HomeMy WebLinkAboutFIR2005-00004 Final AFA - FIR Permit / Conditions - 6/27/2008 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 P14 FIRE PROTECTION PERMIT FIR2005-00004 APPLICANT: VALLEY FEED RECEIVED: 2/7/2005 CONTRACTOR: FIRE ONE INC 206-575-0311 LICENSE: FIRE01*099KW EXP: ISSUED: 2/15/2005 SITE ADDRESS: 461 NE OLD BELFAIR HWY BELFAIR EXPIRES: 8/15/2005 PARCEL NUMBER: 123291290082- Sti,i;LA Zw'f•0001D LEGAL DESCRIPTION: TR 12 NW NE TR 3 OF SP# 1627 EX S 20' PROJECT DESCRIPTION: AUTOMATIC FIRE ALARM -COMMERCIAL FEED STORE. GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: N Zones: Heat Detectors: Wet Chemical?: N Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: ALARM CENTER First Floor: 3,220.00 Type Amount Due Amount Paid Monitoring Phone No.:(800)752-2490 Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Plan $100.00 $100.00 Auto. Fire Alarm Permit $65.00 $65.00 Total: $165.00 $165.00 i'IR2005-00004 Please refer to the following pages for conditions of this permit. 1 of 3 i. Project VALLEY 1=CCD 1-1L1 OLD 6EU:P IR. WVJY ME Date Z- 3 - OS By D P,L E W KLE.t ND FIL E Cop Y. Manufactuer: SILENT KNIGHT- Model SI< y22�1 SUPERVISORY CURRENT ALAR-R-4 CURRENT # QTY MODULE/DEVICE CIRCUIT NAME MA Unit TOTAL MA UNIT TOTAL 1 \ SK H 2ZH CaNT•RaL PhI E-L ZS o Ls 2 1 51t ZI0L-1 DIGITAL DIALEIZ '75 '7S 3 Z Zw 13 3bKE DEffLm1- . S I 10a ZDC� 4 Z N S Zy MCW F(Z NORIs 5TRD E C I S 1 13 v _� 5 Z RSS .ST2C�CEC 6 1 MTWP ZL-I 95' F�L Owroo~ H/5 I LcI 129 7 8 I 9 10 11 I 12 13 14 15 16 17 18 Total Supervisory: Total Alarm: Supervisory: Z`1 hrs . X ISS y Alarm - OS3 hrs . X 11 zZ = q 3 • 1 System Total r7 '7' 1 Add Safety 12% = • ZO 1 . 3 8 -1 S .`1 devid b equals I '$�' AFC • I ed O Required: / O q Total MA. Hrs . q Y O Battery Selected : C- Z) \ZV 7AH MASON COUNTY FIRE MARSHAL Mason County Bldg.III 426 W.Cedar FILE Cur"PY P.O. Box 186 Shelton,Washington 9MU (360)427-9670 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION PERMIT NO. 0 - 0001 MASON COUNTY FIRE PROTECTION SYSTEM PERMIT APPLICATION PLEASE NOTE:This application must be completed and accompanied by a minimum of three (3) copies of plans,specifications, and applicable calculations per Mason County Fire Protection Standards, and submitted to the office of the Mason County Fire Marshal. This is not a permit and failure to submit all necessary information will cause a delay and/or rejection of your submittal. When a permit has been issued,you will be notified. PLEASE PRINT OWNER:_ Y ALL(:_-Y F -imp PHONE:3W_509_5363 FIRE DISTRICT N 6- SITE ADDRESS: LI G 1 0LO BCLFAtk kjCITY BaLc q�{Z STATE\VAZIP 9857-2 MAILING ADDRESS: S N M E CITY STATE ZIP LIEN/TITLE HOLDER: ADDRESS: CITY STATE ZIP CONTRACTOR FIRE ONE IN C ADDRESS: Z14 I Z SHTP AVr S CITY KE.N7 STATEWA ZIP 9803Z CONTRACTOR PHONE#<ux,) S`15 0311 CONTRACTOR REG# F I RF O 1 -X 0 9 9 K W PARCEL# it 3 1- / 91 2 / 9 U 0 Z Z LEGAL DESCRIPTION: BLDG. SQ. FT. (EXISTING/PROPOSED)1ST FL3Z20/ '2ND / 3RD / USE OF BUILDING F t_(O -STU(Z.F DESCRIPTION OF WORK: SPRINKLER: WET DRY STANDPIPE: WET DRY AUTOMATIC FIRE ALARM X HOOD & DUCT DRY CHEMICAL WET CHEMICAL HALON NEW SYSTEM MODIFICATION Pita?U94P MONITORING STN 4.�w �`c_,:u-L PHONE P8d6 -'ZSZ- Zy 9 0-'Z5Z- Z`l9 O YOUR SUBMITTAL MUST INCLUDE: 1. DIMENSIONS, SCALE, NORTH ARROW 2. FLOOR PLAN AND CROSS SECTIONAL ELEVATION 3. ALL CONCEALED SPACES (LABELED COMBUSTIBLE AND NON-COMBUSTIBLE) 4. CUT SHEETS OR REFERENCES FOR ALL NEW DEVICES 5. LOCATIONIDESCRIPTION OF ANY EXISTING DEVICES 6. BATTERY CALCULATIONS FOR FIRE ALARM SYSTEMS 7. RISER/WIRING DIAGRAM FOR FIRE ALARM SYSTEMS 8. HYDRAULIC CALCULATIONS FOR SPRINKLER SYSTEMS PLEASE NOTE: WORK MAY PROCEED ONLY IN ACCORDANCE WITH A VALID FIRE PROTECTION SYSTEM PERMIT ISSUED BY THE MASON COUNTY FIRE MARSHAL. A VALID PERMIT AND AN APPROVED SET OF PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION AND MUST REMAIN THERE UNTIL A FINAL INSPECTION IS DONE BY THE MASON COUNTY FIRE MARSHAL. FAILURE TO OBTAIN A VALID PERMIT PRIOR TO WORKING ON A FIRE PROTECTION SYSTEM AND/OR FAILURE TO PROVIDE THESE PLANS AND PERMIT FOR THE MASON COUNTY FIRE MARSHAL MAY RESULT IN A CITATION AND FINE. OWNER'S AFFIDAVIT I certify that I am exempt from the requirements of the Contractor's Registration Law RCW 18.27, and am aware of the Mason County ordinance requirements for which this permit is issued and that all work will be done in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal. OWNER: DATE: CONTRACTOR'S AFFIDAVIT I certify that I am a currently registered contractor in the State of Washington and I am aware of the ordinance requirements regulating the work for which the permit is issued and all work done will be in conformance therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal. BY: G�L ��" DATE: 2- :5- d 5 Mason County Dept. of Community Development Mason County Bldg. III, 426 W. Cedar, P.O. Box 186, Shelton, WA 98584 Shelton: (360) 427-9670 Belfair: (360) 275-4467 Elma: (360) 482-5269 t Web: http://www.co.mason.wa.us ENFORCEMENT ACTIONS PENDING May 16, 2008 CLINTON SHUMAKER 60 NE DAVIS FARM ROAD BELFAIR WA 98 528 Case Number: FIR2005-00004 Parcel Number: 123291290082 The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Fire code or the code your permit was issued. Your property is currently in violation status of occupancy and use and is pending enforcement actions. You have been made aware of these requirements and to date, have not made the necessary arrangements. Current violations consist of the followina: 2-15-05 Permit was issued for a fire alarm. 4-28-05 an inspection was done with temporary occupancy given for 180 days.11-30-07 Notice was sent requesting final inspection. To date there has been no response and enforcement actions are pending. To bring vour site into compliance. you must: Schedule the necessary inspection(s). A $68 inspection fee will be due prior to each inspection. Please call (360) 427-9670 ext.262 to schedule inspections. Please contact our office to make the necessary arrangements 10 days from the date of this letter. Failure to contact our office to make the necessary arrangements will result in enforcement actions. In the event that you feel you have received this notice in error or that the facts are inaccurate, I strongly encourage you to contact me immediately to discuss your concerns. If not, I will expect these issues to be resolved within 10 days from the date of this letter. If you should have any questions, I can be reached by phone at (360) 427-9670 ext. 285. Sincerely, Larry Waters Mason County Building Department FIR2005-00004 1 of 1