HomeMy WebLinkAboutBLD2024-00308 SFR - BLD Application - 3/7/2024 Permit No: 3 LM 0a 4—00305
MASON COUNTY RE C E I VED
COMMUNITY DEVELOPMENT
Permit Assistance Center,Building,Banning.
e,4AR 0 7 2024
BUILDING PERMIT APPLICATION 615 W. Alder Streetson
�..
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: r
NAME:markie smith,peter francis NAAJE:reality homes
MAILING ADDRESS:100 se evergreen dr MAILING ADDRESS:2720 s J st
CITY:shelton STATE:wa ZIP.98584 CTTy:Tacoma STATE:wa ZIP:98ao9
PHONE#1:390 490 2602 PHONE:253-722-2275 CELL:
PHONE#2:360 490 8396 EMAIL:
EMAIL:markiesmithl718@gmail.Com L&I REG#602170782 EXP.
PRIMARY CONTACT: OWNER E] CONTRACTOR OTHER
NAME marMe snft,peter twas EMAIL markiesmith
MAILING ADDRESS too se evergreen dr CITY 1h1°a" STATE wa ZIP98584
PHONE 360490M2 CELL 3604908396
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number)41910-34-00000 ZONING RR20
LEGAL DESCRIPTION(Abbreviated)se sw,s 49/210 FIRE DISTRICT 13
SITE ADDRESS 726 w wivell rd CITYshelton
DIRECTIONS TO SITE ADDRESS follow wivell rd to the end of county rd,follow private easement through cow fields,driveways on the right
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YESO NO❑ SNOW LOAD:25 psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM E]
TYPE OF WORK: NEW E] ADDITION❑ ALTERATION❑ REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Gamge,Commercial Bldg,Etc residence
IS USE: PRIMARY El SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2.5
HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Pan[s]ofBldg)Q NO❑
DESCRIBE WORK new home
SQUARE FOOTAGE:(proposed)
1 ST FLOOR2168 sq.ft. 2ND FLOOR sq.ft 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft- COVERED DECK280 sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE484 sq.ft. Attached I] Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGEISEWER SOURCE: SEPTIC E] SEWER❑ / NEW I] EXISTING❑
PLUMBING IN STRUCTURE? YES I] NO❑ Ifyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NOQ EXISTING SQ.FT.0
EXISTING BEDROOMS 0 PROPOSED BEDROOMS 3 TOTAL BEDROOMS 3
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this projecL The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection.This permitlapplication becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
nature o O NER( ust signed by the OWNER) 9-1 Date
DEPARTMENTAL REVIEW APPROVED DATE D D DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT W L
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
Permit No: 9 WJOA -00305
Alk MASON COUNTY
COMMUNITY DEYEUOPMENVECE E
N Permit Assistance Center, Building, Planning t=IAR 0 7 20124
PLUMBING & MECHANICAL PERMIT APPLICATION 615 W. Alder Street
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:made smith,peter francs NAME:reality homes
MAILING ADDRESS:100 so evergreen dr MAILING ADDRESS:27za s i st
CITY:sheltm STATE:wa ZIP:985e4 CITY:Tacoma STATE:wA ZIP:98409
I'PHONE:3eo49o2em PHONE:2m--m-2m CELL:
2"d PHONE:36o49oes96 EMAIL :
EMAIL:marrdesnith17l8@gmaii.com L&I REG# Q - - EXP.0XJ/
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Nuntber):4191034-MM Zoning.RR20
LEGAL DESCRIPTION(Abbreviated):se sw,s 491210
SITE ADDRESS:726w,,Wee�d CITY:shenom
DIRECTIONS TO SITE ADDRESS:
follow wivell to end of county rd, follow private easement through cow field, driveway on the right
TYPE OF JOB: `r
NEW 0 V ADD=AL-I=REPAIR=OTHER=USE OF BUILDING ( F,:'V'f S l'f,
LOCATION OF FIXTURES/UNITS— I ST FLOOR=2NDFLOOR=BASEMENT=GARAGEDOTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric[ LPG[= atural Gas[=3Ductless=
Toilets 3 Type of Unit No.of Units Fees
Bathroom Sink 4 Furnace 1
Bath Tubs 2 Heat Pump 1
Showers 2 Spot Vent Fan
Water Heater 1 Propane Tank
Clothes Washer 1 Gas Outlets
Kitchen Sinks 1 Wood/Gas/Pellet Stove
Dishwasher 1 Kitchen Exhaust Hood 1
Hose bibs 2 Dryer Vent
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
X )k W t N I S g /�-/Zjm
Sig na ie of Owner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE I TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT (�E� y.Zl�'
PLANNING DEPARTMENT
FIRE MARSHAL
Rev:1/27/2016 1BN
�l' PLN SETBACKS
Front PLN Approved (doe o, a
08/01/2024 f0d Sides:20'
Mason County Community Development r / �. Rear:20'
Gavin Scouten ��\ / N.' all setbacks measured from the farthest
All Changes Subject to Approval / projection of the building
Disclaimer �__T� J I subject to EH setbacks
Mason County does not require surveys for -
building.As a result,site plans may not reflect
accurate data. It is the applicant's responsibility
to comply with setback requirements. /o
EH Setbacks f°
A.) Drainfield/Reserve requires 10'setback from footing/foundations < r
1aoe�J
B.)Septic tank(s)requires 5'setback from all footing/foundations
C.)No foundation/Perimeter Drains within 30ft,downgradient of �n
Drainfield/Reserve area
D.)No Cut Bank(s)(greater than 5ft and over 45 degrees)within fy (7 �
50ft,down gradient of Drainfield/Reserve area �
\ V " ��
c9�
EH APPROVED ��P i
Rhonda Thompson 09/17/2024
New well is located on 41910-33-00000 /•r^,6
NOT AN APPROVED SEPTIC DESIGN
Must use SWG 2022-00540 for septic installation
-I---- ——- - • -------
ct7i
o
1p,
17=
7;;7
jl
I
Name%jVa ffi�AA Parcel# q�� ' 3�1�( _ BLD# 07OA4 020�i
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
Buildings X =
60 X 61 = 3660 Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X
X If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area(sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described propelr`ty/for review and inspection as may be required.
X o� =� pwner/ gent/Contractor(circle one)Date:
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet.please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name_ Parcel#markie smith, peter trancis 41910-34-00000
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet(page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
httu//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A)Abrhe relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone:(360)-427-9670 EXT.450
Mail: P 0 Box 1850,Shelton WA 98584
Physical:415 N 6th St, Shelton WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352
Mail:P 0 Box 1666,Shelton WA 98584
Physical:426 W Cedar St,Shelton WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required. /
X i\wws \ 1�t" Owtner gent/Contractor(circle one)Dater
Page 2 of 2
Small Parcel Stormwater Site Plan Written Description
Markie Smith, Peter Francis
Parcel# 1910-34-00000
The site is located at the end of W Wivell Rd, Shelton, WA, driveway on the right. It is a 40-
acre lot with 39 acres forestry land and 1 acre residential. The build site is the NW corner of
the parcel. There is a stream type F that runs roughly through the middle of the parcel.
There is a slope (greater than 35%) in the NW corner right side of proposed build location.
Build site in a precleared prior to purchase location. Neither the stream buffer nor the slope
will be disturbed.The driveway is 20x15 ft (250 sq ft) and house 3660 sq ft total impervious
surface roughly 3910 sq ft.
To avoid saturating soils near the foundation of the house, roof runoff will be directed
towards vegetated flow paths via downspout extensions. An onsite septic system is
installed.
Prevent erosion/trap sediments within the project site:
- Mulch will be spread over all cleared areas of the site when they are not being
worked on. Mulch will consist of straw.
- Clear/grade only what is necessary for construction.
- Will gravel driveway immediately.
- Clearing/grading area will be marked.
- Rocked- lined ditch will intercept and direct water from slope.
Aw
cr
S � �
M
X
r �
s. � � tiU►ray v-
-� g�l
ro.
b
�.�+,�+Y,,;;�.,.c�,,.,..,rr iw+.'�•>-,�...»-ww--��«crweae..en.++s���r- �
4 os�vriIs e d �►�,rH- Cave �1a r�
y6yyv\
� � mv1 c�,c� Vv1� ��� ����
te tt
-VVVVVW