Loading...
HomeMy WebLinkAboutExhaust - COM Engineering / Geo-Tech Reports - 12/31/2005 Page 1 Michael Grohs -duct wrap,pdf 3M Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions s NFPA96 eo—c'es"Hi•h :cndec C A Com Ed— inle�natronai $Iannd�n IDBtl Etlmm� Mochanical Cole Mec hanical Code Michael Grohs- FIELD HOUSE FOR HARGIS- Submittal.pdf �Greenheck 06/30/05 JOB: FIELD HOUSE FOR HARGIS Kitchen Ventilator MARK: TYPE 1 HOOD G H E W Type I, Baffle Filter Exhaust Only Wall Canopy CONSTRUCTI ON FEATURES Ktchen Ventilation hood(s)shall be of the Type I,exhaust only wall canopy suitable for all types of cooking applications.The hood(s) shall be U. L.Listed for 400 OF,600 OF,or 700 OF rated cooking appliances. Make-up shall be independently provided. The hood(s)exterior shall be constructed of a minimum of 18 ga stainless steel with a 94 Kool line finish.The hood(s) shall be constructed using the standing seam method for optimum strength. Front panels shall be of single wall construction. An integral 3 in air space is provided to meet NFPA 96 clearance requirements against limited combustable walls.All seams,joints and penetrations of the hood enclosure shall be welded and/or liquid fight. Lighter material gauges, alternate material types and finishes are not acceptable. All unexposed interior surfaces shall be constructed of minimum 18 ga corrosion resistant steel including, but not limited to ducts, plenum,and brackets. SELECTE D OPTIONS &ACCESSORIES Incandescent Light Fixtures-Quantity of 1 -20 footcandles Duct collar with 1 in mounting flange. Grease Cup mounted on right end of Food. Integral 3 in air space on back of hood U.L.Listed without Fire Damper Aluminum Filters Hood to be mounted 78in after the finished floor. 18 ga Type 304 Stainless Steel Where Exposed DESCRIPTI ON Model Overall Width(in) Height(in) Length (in) GHEW 60 39 24 PERFORMANCE (Elevation ft=0) All calculations done with a Open atthe left end ofthe hood and an Open atthe right end ofthe hood. The static losses calculated are internal to the hood and DO NOT include extemal losses, such as ductwork. EXHAUST DATA Section Total Duct Filter Face Qty. Qty. Hood Length Volume SP(in �y Exhaust Dud Velocity Velocity Filter HL 16 20 VA.(lb) # (in) (CFM) w9) Sze(in) (ft/min) (ft/min) (in) in in 1 A 60 675 0.325 1 8 x 8 1,519 101 20 0 3 155 CAPS 2610 Michael Grohs - FIELD HOUSE FOR HARGIS- Submittal.pdf Page 2 &Greenheck 06/30/05 JOB: FIELD HOUSE FOR HARGIS Kitchen Ventilator MARK: TYPE 1 HOOD Hood ID 1 30 3 8 8 39 60 3 4 24 C&us NSF NOTES: All dimensions shown are in units of inches —DRAW INGS NOT TO SCALE— CAPS 25.1.0 Michael Grohs - FIELD HOUSE FOR HARGIS -Submittal.pdf Page 3 1� Greenheck 06/30/05 JOB: FIELD HOUSE FOR HARGIS Kitchen Ventilator MARK: TYPE 1 HOOD Hood ID 1 APPLIANCE LINE UP NOT AVAILABLE Calculation Method: Total —DRAWINGS NOT TO SCALE— -- -- — �ichael Grohs - FIELD HOUSE FOR HARGIS-Submittal.pdf Page 4 Greenheck 06/30/05 JOB: FIELD HOUSE FOR HARGIS Kitchen Ventilator MARK: FSS FL+ L+ Fire Suppression System Wet �7�7 Chemical CONSTRUCTION FEATURES Prepiping of the kitchen hood Fuel shut-off device One double-pole, double-throw microswitch for electric appliances All detectors, links,release mechanism, tank,and fire suppressant agent. One manual pull station for remote mounting (This must be in the path of egress, at a maximum distance of 50 ft feet from the Ansul Automan). An ANSUL tank and release mechanism housed in a cabinet. Final field hook-up to be performed by a nwunion certified ANSUL distributor. Factory coordination offinal system hook-up between jobsite contact and the assigned ANSUL distributor. Notes: The installation of the mechanical or electrical type gas valve is the responsibility Of the plumbing contractor. 0 A double-pole, double-throw microswitch is provided for use with electric appliances. This device also can be used with alarm systems,fan shut down, and electric solenold gas valves. The wiring of this device is the responsibility of the electrical contractor. Permit and Puff test fees. One trip out to the jobsite is included. This program applies only to the continental United States. For an ANSUL hook-up in Alaska,Hawaii,Canada or any International destination, please consu It Greenheck FSSC - 12 1 for details and pricing. Greenhec k HOOD MTD.FIRE CABINET HOOK-UP to consist of: NOTES: Must maintain 6 in clearance between top ofhood mannuualup of detection lines,hock-up of supply lines,mount Shook-up remote and pipe connections. pull,hook-up mechanical gas valve(If Applicable), charge and tag system. ANSUL REMOTE MTD.FIRECABINET HOOK-UP toconsist of: Hood Marks Contained in this System Hang automan and additional tanks if multiple system,hook-up of detection lines, hook-up ofsupply lines,mount&hook-up remote manual pull,hook- Number of Protected up mechanical Hood Mark Appliances gas valve(If Applicable), charge&tag system. The basic firesuppression system does not include the following: TYPE 1 HOOD 1A 0 Permit and testing fees are not included, unless noted under Selected Options and Accessories. Morethan one triptothe jobsite orspecial transportation orovernight lodging requirement in remote areas. A shut-off device (shunt-trip breaker)for electric cooking equipment. Installation ofthe gas shut-off valve. Special drawings required to satisfy a state or local code. -Union tabor, Government labor, or Prevailing wages required for the final field hock-up. Any and all electrical connection required to shut dawn fan(s),electric cooking DESCRIPTI ON equipment, activate an alarm system,etc. Any dismantling or reassembly required togain access tothe firesuppression Total Flow Points Tanks Gallons Aping located on the top of the hood. Plan examination fees 12 2 4.50 Rough-in conduit for remote pull station or gas valve(for flush mounted pull station). Additional remote pull stations. SELECTEDOPTIONS &ACCESSORIES Parts or labor required to correct piping due to cooking equipment changes or deviation Mechanical Gas Shut-Off Valve 1 1!2 inch Required from plans. Chrome Appliance Drops �Any charges for missing or additional parts other than those indicated on the Permit Fee attached Mounting Position,Right End NoteeSuppression Detail. The customer is responsible for and will be invoiced separately for any additional work performed in accordance with the above items. The ANSUL fire cabinet contains the release assembly that must be mounted within 60 in of the canopy. CAPS 2 6?C