Loading...
HomeMy WebLinkAboutFIR2005-00049 - FIR Permit / Conditions - 5/4/2006 .5uMASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 s Shelton,WA 98584 FIRE PROTECTION PERMIT FIR2005-00049 APPLICANT: MASON COUNTY PARKS RECEIVED: 12/22/2005 CONTRACTOR: LICENSE: EXP: ISSUED: 5/4/2006 SITE ADDRESS: 1000 NE SAND HILL RD BELFAIR EXPIRES: 11/4/2006 PARCEL NUMBER: �4M460000 LEGAL DESCRIPTION: N 3/4 OF NE EX PROJECT DESCRIPTION: New System GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: Y Dry Chemical?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Zones: Heat Detectors: Wet Chemical?: Y Sprinkler?: Standpipe?: SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:()- Second Floor: Hood & Duct Permit Fee $100.00 $100.00 Auto Fire Alarm?: Third Floor;: Hood and Duct Plan $65.00 $65.00 Hood and Duct Plan $100.00 $100.00 Hood and Duct Plan $65.00 $65.00 Total: $330.00 $330.00 FIR2005-00049 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FIR2005-00049 CONDITIONS FOR FIR2005-00049 1.) Hood suppression system is approved as submitted providing the 36 inch grill is electric. If a gas grill is utilized, an approved gas shut off valve is required. X C .W . Provide a type K fire extinguisher and mount in an approved location. X If the building has an automatic fire alarm system, connect the hood suppression system to the alarm and report as a separate zone. XL. � , Upon completion of installation, call to schedule a trip test at 360-427-9670 x 273. X C,cj This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerorthe agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and strycture fob r vie an ection. &1L0(' OWNERORAGENT: DATE: FIR2005-00049 Please refer to the following pages for conditions of this permit. 2 of 3 JUN. 2. 2006 12. 50FM SANDERSON SAFETY NO. 673 P. 2/2 A����� AN3ULINCORPORATED DISTRIBUTOR CERTIFICATION MARINETrE.WI 54143.2542 QN4:STALLATION Ifdtd FOR ANSIUL RESTAURANT FIRE SUPPRESSION SYSTEM L Custoltr Name 5AAD RI U— ft?,h Address O©O 1 %E. rj6Kb g( LF�e �'�• �5 ZCL SYSTEM ONE Model MVO. 1�10 Soo 115 c-A"M Number of nozzles and Part No, I - -PLC N� r (0VCC— Number of detector(s) and degree rating 1 (a 3w I? �1' _ 4 Energy shut-off devices-type and size MSCIZOSW VttA �--�ZHC*� .�y ►�N Other accessory equipment provided 5W10 puLL �c7 ir P B r Mrl� COO KINGNENTILATING EQUIPMENT Number of duct(s) and size L i / x Plenum Slze �� Cooking Appliances and size (NOTE: Llst appliances from left to right) EM TWO Model Number of nozzles and Pa Number of detector(s) and degree rats Energy shut-off devices-type and size Other accessory equipment provided COOKINGNENTILATING EQUIPMENT Number of duct(s) and size Plenum Size Cooking Appliances and size (NOTE: List appliances from left to right) 1 TO BE COMPLETED BY INSTALLER YES ❑ NO The restaurant flre suppression system Is UL300 listed and installed in accordance with the manufacturer's instructions, NFPA Standard 96 and 17A(current issue), and all applicable state and local codes. It Is a requirement of the manufacturer and recommendation of the National Fire Protection Association that the fire system be Inspected and maintained every 6 months for proper system operation. Exceptions to other provisions of NFPA 96 that were observed are noted below, Exceptions: ( ] YES ❑ NO All electrical work or work provided by others to complete system installation completed. YES q NO Copy of owner's manual left with owner. _INSTALLER NAME _ Cb� SIGNATURE DISTRIBUTOR S - i ADDRESS 34 1 n0-4 inn —— 206)3 4 DATE � I sp ct wi - and approved by: ANSUL 19 A replatered trademark. m Fire spector PAR No,2 9.05 P 998 Ansul Incorporated Litho in U.S,A. APR. 28. 2006 10: 48AM SANDERSON SAFETY NO. 885 P. 1 �V, ft -1 AT 2 k4 FAX TRANSMISSIO For Review t Call if incomplete F4 please reply i L t To: U-Prt C) Fax, �`?>�u� ` 211 - ✓� Company: i 6UI D, Date: !2,b4 From: Dave Carlsen Fire Service Manager Pages including cover letter: 2600 Airport Way S. Seattle, WA. 98134 Phone: 206-340-4300 Fax: 206-340-4301 Pager: 206-314-6640 Comments: C � ) Rvob -A- wt7' S uf hi% I 3T,� P RC 1 Pc-) F MASON COUN-TiN FIRE MARSHAL DA — � 9MlaRn� � c�iw Q mow: a r�F'?�Y7; fs�'.'tv7�It41li;wf:�1f�Q'.NFi�IC;i.1fi idir- T+M5 0MIF- �,�7"+�r.l�l�i��+Mfkns,rr• A V THE Rlf� iF r; .+FtkA h A�is;r:¢Sm (z;. -l'X7`-1 LAWS- SANDEFISON SAFE I V SUPPLY CO. 11 of S.E.3rd Avenue, Portland,OR 97214 (503)238.5700 ORFOON WASHINGTON. CALIFORNIA IDAHO ELSana Seattle 80111n9112m Richmond Bolas 850 Conger St.97402 2600 Airport Way,S.90134 355 Ohlo St.98225 4909 Central Ave.94805 (541)683.9333 (206)340.4300 (360)734-1110 (510)559.8400 (208)343.1323 EQUIPMENT EEGEM `- -bpi£ H JODj 5'-L' (64') - Slif'f'LY R I I+e47ERTAt LFEEh'D P') LABEL MESCRIPTLIN ISLL PIPING Its 3/8' SCiL 40 ALAtC PIPE IWCi: 9' 1( in, U[n 4 FED-V P1711iTS UT1i- DESCRIPTION 410913 1 FART t fL� A 36' GRCLL LS fAL. ANSUL STSTEP I Igo - - ALL FIELD DwasEO PiPw SLEETED IN cft?uw TUTX 4 FLUY POINTS ALT I Ilc 4i9345 I E)OMET FM TU RUWJ)? ❑PL HUEUP AIR, CiA.S 1 26( 419352 2 ALL Ei�Cr_iRIC TO SHUT-DIIti4a INS SYSTEM _ RLT[iATB i I SVIVEL ADAPTER 423512 cv NOZZLE Pr AMMENT ITS ANSUL UL-30D IMIERIA - - - TL1SE L-JMS TO aE f ETE"INU D/ INSTALI.Eft IDOF *,GAS VALVE RFMPE0 cry - NU "IZONTAL PIPING It¢-= THE FOCI] CID ..J�1`11J IF,�� `�� • 1-0 -------t fIxS o E7.R � Ly 1 i 1 - - I311 ----57�---- 4510 03 o-) m (10 m UL30 ryl SYS H Ln w HUD Q . - cr) CD o Z7 Q S DC -• RECITE PALL ACTUATHIR STAUM CARTR[BC m�� ca1Ay E �� 0 GREASE sail 1ULL PARK L w .� C- �VSAS'I'E R_ru EDG VDGD VA 12/9/Q5 s�83s� 2 5' (isvi URS_L E17DIX 8521 9231 R�I(770 521 ssia rM L FIRE SYSTff7! DEW1 RY PCALE rlm DATE 0 infoBgreasemasT r_cu�r� _ - AIRE/PRU INC. fRDlIOSzm RM 14TS -- 1IN I or 1 --- d�Ry a�r�.vnr�rsr ♦IacK�4• I�cuQ� "'--'-APR. 28. 2006` 10:48AM'15RERISANDERSON SAFETY 56336888818 TO:12063,10M. 885 P. 81.0a3 0e3 PACKINQ,LIST T[,;<•E FOLLOWING MATRIUA1L IS,BETTIG SENT TO YOU,FORT .bb NRMQ: 5A.NI?HTr L PARK Upd�{P.a1,: 2/8/2U05 ol.lr Joho 1148311 SI1ip; 12/231200S CREASE MACTUR ANSUL D13SC IPTION S141PPED INSTAT-LED PROV.ID6'Ll TOTAT. TO nv >3� PARTPART 8 .01S'IR BUTOR H.-CODS INSTALLER RUANITY GM FPAS/SA,UTOMAN 429353 AUTQ1IVIA•N(SIS ENCLOSURB 1. 1 'OMFPASWi7C,HUrDT. 423;619 M•LC o,SW.TC1 GM FPA REMOT PULL 4539 krN! TB PUL'> S 1 9 CAM.aP• LSTANX 429 64' '1.5 g L.L01`1IANIC 1 1 GM.VFA$9ALADP 423253 moo _A1.ADAPTORS 1 1 1 CAM FP L1IC KSPAL3/8 QSA.t 3/0' QVICKSEALS ROOKS 3 9 CM FPA PULLYELDOCO'NJ.P 423251 itib.Rr4tR Pf tBYS 10 1 I1 GM FPDSJ?.P-rRSDBTPC 417369 SCISS 1:t DET LLNK I40T..DER9 grab T78 i 1 y..3 CKRST.n13'V CS38 CT41i MP SI:, pwrNCt nOCKS;2 FT Lgl}1O' H". 1. 1 am FPN 1.100 43091.2 NOZZLES l l.00 t. 3 CM FPN IN 419344 NOZZLES.IN i 0-W FDN 260 419352 N07 ,Us 260 1' 1 amp FPSWV1:,N07_ 422572 N07 .:5,4,WN L ADAPTORS M FPC 01•10CART' I5310 10'1-1tI Att ;12i17f1E? 1 CrM,FVL1.5QALAN9T 7C 79694 .1.5 GAL AN'SULEX � 1 GM FPFFUSELINX 173967 J?USE .TNKS 1 1 QM•T+PF?'Ust?L1NKT,8ST 2A9l6 TUST .MO, t 1 f ' Ci;/FiRS3p3tOT1:CTTON/T'F Vy!oTkel�Eec1 YcT x 1.21918005 APR, 28, 2006 10: 48AM SANDERSON SAFETY NO. 885 P. 4 SECTION IV — SYSTEM DESIGN UL EX, 3470 ULC CEx747 Page 4-30 4-30-02 REV.2 NOZZLE PLACI=MENT 111EQUIREMENTS(Continued) Nozzle Appticatlon Chart The following chart has bean developed to assist In calculating the quantity and type of nozzle required to protect each duct,plenum, or appliance. NOTICE -This chart is for general reference only. See complete details for each type of hazard. Maximum Hazard Nozzle Nozzle Nozzle Tip ar Nozzle Stamping— 1f Part No o i DOctw-1r4trleldbn to"ri'tjTpi-UNii`nitea 1 430912 (Single Nozzle) Perimeter—So in.(127 cm) 1100' Diameter—16 in.(40.6 cm) Duct or Transition Length—Unlimited 1 4,19337f78078'(Single Node) P'6k titer-10'0 I6.(254 cn1) 2W/2WH' ' Diameter--31 718 In. (81 crnj Duct or Transition Length—Unlimited 2 419337/78078' 2W/2WH" (Dual Nozzle) Perimeter—150 in,(381 cm) Diameter—48 In. (122 cm) Electrostatic Precipitator Individual Cell 1 419334 (At Base of Duct) 112N Plenum L®nglh—10 ft(3,1 m) 1 — 419335/417332 1 t 1 NSS (Horizontal Protection) �� Plenum Length—4 ft. (1,2 m) 1 — 419336/417333 1 W11MS (Vertical Protection) Width—4 ft (1.2 m) Pryer/Split Vat Fryer" Maximum Size (without drip board) 15 In, (38 cm)x 14 in. (36 cm) High Proximity 1 27—47 in. 419339 230 Medium Proximity 1 20—27 in, 419340 245 Maximum Size (without drip board) 19 1/2 in,(49.5 ern)x 19'in,.(46.2 cm) High Fmximity 1 21 -•34,in, 419338 3N Low Proximity 1 13—16 in, 419342 290 Maximum Size (without drip board) 18 in.(45.7 cm)- x 18 in. (45,7 Cm) High Proximity 1 25—35 in. 419338' 3N (54-89 cm) a , Use 2M Heine on 1.5 gnpon,8 now,dodt 4 Mamim prvlaogon ony. "For mukl*noizle prod Uon of single hynm,see datnbd hderinndon on PSW 4-12 IMmugh 4-14. APR, 28. 2006 10: 49AM SANDERSON SAFETY NO. 885 P. 5 SECTION IV - SYSTEM DESIGN UL EX.3470 ULC CEx747 Page 4-32 4-30-02 REV. 3 NOZZLE PLACEMENT REQUIREMENTS (Continued) Nozzle Application Chart (Continued) Nozzle'rip Maximum Hazard Nozzle Nozzle Nozzle Stamping- Mmensigns pjAnfiIx H.j= Part No, pj�w Kim Griddle Longest Side(High Proximity) 1 30-50 in, 419341 CD48 in, (122 cm) (70--127 cm) Area-1440 sq.in, (perimeter (9290 sq.cm) located) Longest Side(High Proximity) 1 30-50 In. 419342 290 30 In.(76 cm) (76-127 cm) Area-720 sq. in. (center located) (1829 sq.cm) Longest Side(High Proximity) 1 35—40 in, 419335/417332 1 N/1 NSS 36 in. (91 cm) (89-.102.cm) Area-1080 sq.In. (perimeter located) (2743 sq.cm) Longest Side 1 20-310 in. 419342 290 (Medium Proximity) (51-76 cm) 48 in. (122 ern) (perimeter Area-1440 sq.in. located) (9190 sq,cm) Longest Side(Low Proxlmity) 1 10 20 in. 419343 2120 48 in.(122 cm) (25-51 cm) Area-1440 sq.In. (perimeter (9290 sq.cm) located) Chain Broiler" Longest Side- 34 In. (86 cm) 2 10-26 In. 419330/417333 1 W/1 WSS (Overhead Protection) Area-1068 sq. In. (25-66 cm) (7019 sq.cm) Chain Broiler Length-43 In.(109 cm) 2 1 -3 in. 419335/417332 1N/1NSS (Horizontal Protection) Width-31 in, (79 cm) (3-8 cm) Gas-Radiant Char-Broiler Longest Side--36 in.(91 cm) 1 15-40 in, 4193351417332 1 N/1 NSS Area—B64 sq.In. (38-102 cm) (5574 sq.cm) Electric Char-Broiler Longest Side-34 in,(86 cm) 1 20-50 In. 419335/417332 1 N/1 NSS Area-680 sq. In. (51 -127 cm) (4388 sq, cm) Lava-Rock Broiler Longest Side- 24 In.(61 cm) 1 18-35 in, 419335/417332 1 N/1 NSS Area-312 sq.in. (46-89 cm) •(2013 sq.cm) Natural Charcoal Broiler Longest Side-24 In. (01 cm) 1 18-40 In. 419335/417332 1 N/1 NSS Area--288 sq.in. (46-102 cm) (1858 sq.cm) Lava-Rock or Natural Longest Side-30 In. (76 cm) 1 14-40 In. 419338 3N Charcoal Char-Broiler Area-720 sq.in, (36-102 cm) (4645 sq.cm) ' minimum chain brellor oxhouet opening—12 in.K 12 In.(31 cm x 31 cm),"not lew Ihan rdaly of Inlofnal Droner alze. The WR. 28. 2006AI0: 49AMced McSANDERSON SAFETY NO. 885 P. 6 Assemoly(3,0 gallon _ part No. 79290 or 1,b gallon — ran too. , eXp@l contains the regulated release mechanism, agent � q-102 RESTAURANT RANT lank, expellant gas hose for agent tank hookup,and enclosure r7 �J knockouts to facilitate installing actuation piping; expellant6 � SUPPRESSION piping;detection system;and additional equipment.This regu 6 lated release assembly is used in single,double, and multiple- �S ���11DD11�td tank systems And must be mounted to a rigid surface- The ff � e� +�+.7�/��yy release mechanism Can be used to interconnect bath the actu• (Standard &J ® Listed) and expellant oas lines as required per system design.The regulator is deigned to allow a constant flow of gas into the tank at 100 psi (690 kPa) when the system is actuated. In single,double,and multiple-tank systems,the providec expel- rant gas hose connects the agent tank to the bottom outlet of Nozzle Identification Chart the regulator,In double and multiple-tank system configurations, the back outlet of the regulator is used as an expeltant gas feed Nozzle Nozzle Nozzl for one additional tank-enclosure or tank-bracket hookup.The Ngz LP Part No Stamoing ELO � enclosure contains the required knockouts to facilitate this con- 1W Nozzle 419336 1 W 1 nection, If a pressure switch is to be attached to the regulator, 1 WS5 Nozzle 417333 1 W 1 additional fittings are required. The tank is mounted within the enclosure. The tank contains IN Nozzle 419335 IN 1 an adaptor/tube assembly with a burst disc union,The burst disc 1 NSS Nozzle 417332 1 N 1 helps prevent siphoning of the agent up the pipe due to signifi— cant temperature fluctuations in the area where the tank is located. The tank is mild steel and. under normal conditions, 3N Nozzle 419338 3N 3 requires hydrostatic testing every twelve years. ..� 2W Nozzle 4 2W 2 19337 The agent lank is shipped uncharged and must be filled with 2WH Nozzle 19337 2WH 2 1.53 gallons (5,8 L)or 3,05 gallons (11.6 L)of only ANSULEX Low pH Liquid Fire Suppressant during installation. The detection and additional equipment required per system design are connected to the release mechanism.The enclosure 230 Nozzle 419339 230 2 contains knockouts to facilitate detection and additional hookups. 245 Nozzle 419340 245 2 The system can be actuated automatically or manually, Auto- _ip 260 Nozzle 419341 260 2 matic actuation occurs when a fusible link within the detection 290 Nozzle 419342 290 2 system separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull 2120 Nozzle 419343 2120 2 station pull ring, 1 F Nozzle 419333 IF 1 EXTINGUISHING AGENT '7 11DO NDZU4 A30912 1100 1 ANSULEX Low pH Liquid Fire Suppressant (1.5 gallon — Part No. 79694 or 3.0 gallon — Par No. 79372)is a potassium-based solution designed for fast knock-down and suppression of grease-related fires.The agent is shipped in plastic containers which provide one complete tank charge. Agent storage life expectancy is twelve years,The distributor must record the batch numbers and date of shipment receipt to be filed with each instal- lation record. Total Tank Type of Nitrogen Carbon Dioxide i MNo., Quanti S T a Cartndae Req+ e a Re 1-5 1 Single 1.5 Ga.l, Reg. Rai LT-20-R (7032) 101.10(15850) 6-11 1 Single 3.0 Cal, Rag.Release LT 30-R (5373) 101-20(17492) ELECTRICAL SWITCHES IK EPtCf{ A(1TDY1 sot The electrical switches are intended for use with electric gas valves, alarms, contactors, lights, contractor supplied electric Power shutoff devices and other electrical devices that are designed to shut off or turn on when the system is actuated. Switches are available in kits; One Switch Kit, Part No. 423878, Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. 423880, and Four Switch Kit, Part No.423861. Each switch has a set of singlO-pole, double-throw contacts rated at 21 amp, ,1 HP, WN��125,250,277 VAC or 2 HP, 25D, 277 VAC. Mounting hardware is provided with each kit COMMON N.C. 5\ PLY A(K SAUT5 OX 0 0 41 "VVo td.Va i-ZLA OUV 4L1 / IOU aUx Viv %IV rr1AM11 \.1K 1(/. UUL MASON COUNTY FIRE MARSHAL -Fl nth Mason ounBldg-11426 W Co PO BOX 186 Shelton I WA 98584 danCEIVED (360)427-9670 Ext.273 DEC 2 0 2005 ermit# Fl a �� MASON COUNTY Mason County Fire Protection System Permit Application .Incomvlete application will not be accented.' Owner: ht'd""'s 1- Phone#: Mailing Address: City: State: zip: Site Address: �U)o A•C ,S"A(L_T City; 1 (-LFrrj 2 State: 4r Zip: 5 Z9 -Parcel.*:.- 6--� - o�� -L� Legal Description: Lien/Title Holder: Address: City: State: Zip: Contractor: _Sp): R t, �e'l� Phone#• t'5b� -55 Z.— Address: (,(�;,v 1 l S= S City: State: U* Zip: ,/U134 Contractor R-epistration#: Expiration Date: 0 Building Square Footage(existing&proposed): lgt / 2nd / 3A / Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry New System: Standpipe: 'Wet Dry Modification: AFA: Hood&Duct: Dry Chem: - Fire Pump: UL certified Monitoring company: Phone#: Contractors Bid Price: $ �Q bl) too 1L/VA/GVVJ 11)1V rAA JOV 41C1 11VO IT"OVly 1..V rrIIkM11 klin WJUU1/UUI 1 I Plan Submittal Requirements Your plan submittal shall include the following: • Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and for area separation walls,partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floorplan. • Electrical riser diagram showing all zones,circuits,devices, and end--of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a r mnimum of V00.00. - - - i plan review fee will be calculated at 65%of the permit fee and is due upon submittal of permit application. Contractor's Affidavit I certify that I aim a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance_ No changes will be made without first obtaining approval from the Mason County Fire Marshal. --- By, --- Date: -'D kV- O LSM EQUIPMENT LEGEND NOTE, NwDi 5'-0' (601 SUPPLY R 1 FATERTAL LEGEND { LABEL DESCRIPTRN Dmn,19' X In, (38•) 4 PLOY P13ItITS 1 19 -� ALL PIPING A 3/R' SCH. 40 ELACK PIPE UTY DESCRIPTION PART ! fLEPd m GRILL m LS CAL ANS(A SYSTEM 1 11D0 43D913 1 ALL FIELD EXPOSED PIPING SLEEVED IN CHR01'E TUTAL 4 FLUW POINTS 1 IH 41934L I - - EXHAUST FAN TO iOXM)4 ON. MAKEUP AIR. GAS 1 264 419352 2' AND ALL ELECTRIC TO SHUT-1)ONt: ON SYSWK - - ACTUATICkl 1 SWIVEL ADAPTER 423572 NOZZLE PLALEW-NT MEETS ANSUL UL300 CRITERIA - - - _ FUSE L-D&S TO BE DETERMINED F-Y INSTALLER GAS VALVE REQUIRED NO HIMIZONTAL PIPING HIDE THE HOOD CD S'(�(VS� I- \L)— fK4 CD IT fri60A------ �D CD CP j �] 0 27,E I ' 13fl,�----47d---- 45.0 co ----`ti co O] co �� 1.5 CALLEN SYSTEM u7 LfOD Lr 0i uu..w tl, �� 1 260 _ Sa C- \ U spA)k (6 �� � REMDTE PULL ACTUATION <I STATELTN CARTRIDGE LU 240b H(4M- Lk Aj S ; �►� c Pal T 0,r-c-C,K�s CD LL CD �01 GREASE SAND HILL PARK f v MASTER Tu EDGEWD(ID, VA 12/9/05 F48339 2 _" GSWI GRILL T POST 0MCE 80X D3 p;(3 WI TRAA- NC 26D7S U TEU94tWE (704) 82t-92t1 FAX (704) 821-6616 ANSUL FIRE SYSTEM DFLWJ E<f WEE:f W Info Ckj eosemast,erx*m AIRE/PRl7 INC. CRD8D520) RM NTT — HN 1 GF 1 i DEC-09-2005 16:56 FROM:6REASE MASTER 256536888818 TO:12063404301 P-003/003 PACKING LIST r M I TM FOLLOWING MATERIAL IS BEING SENT TO VOU FOR! Job Nnme: SAN I HILL PARK 1! dsl:ccl� 2/8/20� 05 Ourdoho F48323 Ship: 1212-1/200S GREASE MASTER ANSUL DESCRIPTION SHIPPED INSTALLED PROVIDED TOTAL TO TN BY PART# PART DISTRMUTOR HOODS INSTALLER QUANITY GM FPAS/SAUTOMAN 429853 AUTO`MAN S/S ENCLOSURE 1 1 GM FPASWIxCHDPDT 423879 M.ICRb,S�V�TCT�bPUT 1 ] GM FPA REMOTEPULL 4835 REMOTE FULLS I I GM FM. .S'TANK 4298fi4 1.5 Q LLON TANK ] 1 GM,FPASFALADPT 423253 HOOD SEAL ADAPTORS i 1 GM FP UICKSEAL3B QSA.1 319" CKSEALS ROOKS ; 3 GM FPA PULLYEL DOCOMP 423251 CORN 3k PtPLLEYS 10 7 11 GM FPDSERLESDETP,C 417369 SCISSOR DET LINK HOLDERS SERIES 1 t GM 3/SCH SL.EEV CS39 CMOME SLEEV?Nfl ROOKS;2 FT LE�1OTf 1. t GM FPN 1.100 4-10912 NOZZLES 1100 1 1 GM FPN IN 419346 NOZ US,IN t 1 IaM:FPN 260 419352 N077LES,260 1 GM;"SWVLNa2 423572 N077LES,SWIVEI ADAPTORS ( 1 OM FPC101-10CART' 15850 101-10 CARTR3OQE 1 1 GM.FPLI.50ALANSLX 79694 1.5 GA.L ANSULEX t 1 GM FPFFUSELINK 73867 FUSE INKS t 1 GM.FPFFUSELINK'TEST 249t6 ITESTONKS. L i „ r Work-sheets VcP0�/FTRLPROTECTTON/ I A f. aa,xrii ,F k. L�it, v `I 1.V9/2005 T"'pryi-7S t •'�=` �•r,n 'A.� c�- yic( dd,a�j S,, Ic E:'.+,.:s.a `.9td3c 53� '.�1v+x� r� '^.+, 1 ,rRW�h l q x a + '� i�.— .t.. .,j.Tw, w,'.y,Y -.t c4d• {^,c.. t: ,�T '.;.i. °X - x ....ti..' r...?z�"yr?°,'r'a' :`'.�.a„...Yh.}." w,.;�'1z# '•rr..krTJis4.,L'h. t SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-30 4-30-02 REV.2 `. NOZZLE PLACEMENT REQUIREMENTS(Continued) Nozzle Application Chart The following chart has been developed to assist in calculating the quantity and type of nozzle required to protect each duct,plenum, or appliance. NOTICEThis chart is for general reference only. See complete details for each type of hazard. Maximum Hazard Nozzle Nozzle Nozzle Nozzle TipStamping— Hazard Dimensions Quantity Heiahts Part No. Flow No. ► Transition LengthUnlimited 1 — 430912 ingle Nozzle) Perimeter—50 in.(127 cm) Diameter—16 in. (40.6 cm) Duct or Transition Length—Unlimited 1 — 419337/78078` 2W/2WH' (Single Nozzle) Perimeter—100 in.(254 cm) ' Diameter—31 7/8 in.(81 cm) Duct or Transition Length—Unlimited 2 — 419337/78078' 2W/2WH (Dual Nozzle) Perimeter—150 in.(381 art) Diameter—48 in_ (122 am) Electrostatic Precipitator Individual Cell 1 — 419334 1/2N (At Base of Duct) ' i Lft. (3.1 m) 1 — 419335/417332 AW1 NSS onzontal Protection) Plenum Length—4 ft. (1.2 m) 1 — 419336/417333 1 W/1 WSS (Vertical Protection) Width—4 ft. (1.2 m) Fryer/Split Vat Fryer" Maximum Size (without drip board) 15 in. (38 cm)x 14 in_ (36 cm) High Proximity 1 27—47 in_ 419339 230 Medium Proximity 1 20—27 in. 419340 245 Maximum Size (without drip board) 19 1/2 in.(49.5 cm)x 19 in. (48.2 cm) High Proximity 1 21 —34 in. 419338 3N Low Proximity 1 13—16 in. 419342 290 Maximum Size (without drip board) 18 in.(45.7 am) x 18 in. (45.7 cm) High Proximity 1 25-35 in. 419338 3N (64-89 cm) Use 2WH noaie on 1.5 gaflon,6 Now.duct and plenum protection only. '^ For multiple nozzle Protection of single tryers,see detailed informacon on Pages 4-12 through 4-14. - t ` SECTION IV — SYSTEM DESIGN UL EX. 3470 ULC CEx747 Page 4-32 4-30-02 REV 3 NOZZLE PLACEMENT REQUIREMENTS (Continued) Nozzle Application Chart (Continued) Nozzle Tip Maximum Hazard Nozzle Nozzle Nozzle Stamping— Hazard Dimensions Quantity Heights Part No. Flow No. Griddle Longest Side(High Proximity) 1 30—50 in. 419341 260 48 in.(122 cm) (76—127 cm) Area—1440 sq.in. (perimeter (9290 sq.cm) located) Longest Side(High Proximity) 1 30—50 in. 419342 290 30 in. (76 cm) (76—127 cm) Area—720 sq. in. (center located) (1829 sq.cm) Longest Side(High Proximity) 1 35—40 in. 419335/417332 1 N/1 NSS 36 in. (91 cm) (89—102 cm) Area—1080 sq.in. (perimeter located) (2743 sq.cm) Longest Side 1 20—30 in. 419342 290 (Medium Proximity) (51 —76 cm) 48 in. (122 cm) (perimeter Area—1440 sq.in. located) (9190 sq.cm) Longest Side(Low Proximity) 1 10—20 in. 419343 2120 48 in. (122 cm) (25—51 cm) Area—1440 sq.in. (perimeter (9290 sq.cm) located) Chain Broiler' Longest Side—34 in. (86 cm) 2 10—26 in. 419336/417333 1 W/1 WSS (Overhead Protection) Area—1088 sq. in. (25—66 cm) (7019 sq.cm) Chain Broiler Length—43 in.(109 cm) 2 1 —3 in. 419335/417332 1 N/1 NSS (Horizonta! Protection) Width—31 in.(79 cm) (3—8 cm) Gas-Radiant Char-Broiler Longest Side—36 in.(91 cm) 1 15—40 in. 419335/417332 1 N/1 NSS Area—864 sq.in. (38—102 cm) ► (5574 sq.cm) Electric Char-Broiler Longest Side—34 in.(86 cm) 1 20—50 in. 419335/417332 1 N/1 NSS Area—680 sq.in. (51 —127 cm) (4388 sq.cm) Lava-Rock Broiler Longest Side—24 in.(61 cm) 1 18—35 in. 419335/417332 1 N/1 NSS Area—312 sq.in. (46—89 cm) (2013 sq.cm) Natural Charcoal Broiler Longest Side—24 in.(61 cm) 1 18—40 in_ 419335/417332 1 N/1 NSS Area—288 sq.in. (46—102 cm) (1858 sq.cm) Lava-Rock or Natural Longest Side—30 in. (76 cm) 1 14—40 in. 419338 3N Charcoal Char-Broiler Area—720 sq.in. (36—102 cm) (4645 sq. cm) Minimum chain broiler exhaust opening—12 in.x 12 in.(31 cm x 31 cm),and not less than 60%of internal broiler size. The ANSUL AUTOMAN Regulated Mechanical Release Assembly(3.0 gallon - Part No. 79290 or 1.5 gallon - Par No. 79291) contains the regulated release mechanism, agem 4, s e ,� tank, expellant gas hose for agent tank hookup.and enclosure e - 1 0 ml! E knockouts to facilitate installing actuation piping; expellant piping;detection system;and additional equipment.This regu- l R S r� N lated release assembly is used in single.double,and multiple- tank systems and must be mounted to a rigid surface. The release mechanism can be used to interconnect both the actu- 6 �� ation and expellant gas lines as required per system design.The (Standard � �(�L��x� regulator is designed to allow a constant flow of gas into the tank at 100 psi (690 kPa)when the system is actuated. In single,double,and multiple-tank systems,the provided expel- lant gas hose connects the agent tank to the bottom outlet of the regulator.to double and multiple-tank system configurations. Nozzle Identification Chart the back outlet of the regulator is used as an expellant gas feed Nozzle Nozzle Noz for one additional tank-enclosure or tank-bracket hookup.The Nozzle Type Part No. Stamping ping Flou enclosure contains the required knockouts to facilitate this con- 1 W Nozzle 419336 1 W 1 nection. If a pressure switch is to be attached to the regulator, additional fittings are required. 1WSS Nozzle 417333 1 W 1 The tank is mounted within the enclosure. The tank contains 10mozzle 419335 1 N 1 an adaptor/tube assembly with a burst disc union.The burst disc 1 NSS Nozzle 417332 1 N 1 helps prevent siphoning of the agent up the pipe due to signifi- cant temperature fluctuations in the area where the tank is 1/2N Nozzle 419334 1/2N 1/2 located. The tank is mild steel and,under normal conditions, 3N Nozzle 419338 3N 3 requires hydrostatic testing every twelve years. 2W Nozzle 41 2W 2 The agent tank is shipped uncharged and must be filled with 1.53 gallons (5.8 L)or 3.06 gallons(11.6 L) of only ANSULEX 2WH Nozzle 78078 078 2WH 2 Low pH Liquid Fire Suppressant during installation. The detection and additional equipment required per system design are connected to the release mechanism.The enclosure 230 Nozzle 419339 230 2 contains knockouts to facilitate detection and additional hookups. 245 Nozzle 419340 245 2 The system can be actuated automatically or manually. Auto- 10 Nozzle 419341 260 2 matic actuation occurs when a fusible link within the detection system separates in a fire condition. Manual actuation of the 290 Nozzle 419342 290 2 system occurs when personnel pull on the remote manual pull 2120 Nozzle 419343 2120 2 station pull ring. IF Nozzle 419333 1 F 1 EXTINGUISHING AGENT NOW AS0912 Iloo I ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon - Part No. 79694 or 3.0 gallon - Part No. 79372)is a potassium-based solution designed for fast knock-down and suppression of grease-related fires.The agent is shipped in plastic containers which provide one complete tank charge- Agent storage life expectancy is twelve years.The distributor must record the batch numbers and date of shipment receipt to be filed with each instal- lation record. Total Tank Type of Nitrogen Carbon Dioxide Flow No." Quantity System Type of Hardware _ Cartridge Reauired Cartridge Reauired 1r6� i Single .5_Gai.Reg. Release MOM(7032) 101-10 (15850) 6-11 1 Single 3.0 Gal. Reg. Release LT-30-R (5373) 101-20(17492) ELECTRICAL SWITCHES —1_0CATtp:p It3 Ems{ h T D The electrical switches are intended for use with electric gas valves, alarms, contactors, lights, contractor supplied electric Power shut-off devices and other electrical devices that are designed to shut off or turn on when the system is actuated. Switches are available in kits: One Switch Kit, Part No. 423878, Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. 423880,and Four Switch Kit, Part No.423881. Each switch has a set of single-pole, double-throw contacts rated at 21 amp, 1 HP, 125,250,277 VAC or 2 HP,250,277 VAC. Mounting hardware is provided with each kit. E�"P�v�TN 5 r— yS or COMMON / N.C. SV L� k I R_ T5 OK o \ ^ M C N.O.