HomeMy WebLinkAboutBLD2024-00591 SFR - BLD Application - 7/25/2024 BUILDING SErRACKS:
TCE =INSTALL TEMP. CONST. ENTRANCE Retaining walls needed to support a surcharge such as structures, ntONI:10' SDL 5' RFAR:,0'
TSS =INSTALL TEMP. SOIL STOCKPILE roads,or to support slopes,shall require a separate building permit
and approval prior to construction of the retaining
47' 8' 50.51'
W
' ' RETAINING WALL PROPOSED
T S51'36'34W CONTOURS
I23.15'
PROPERTY BOUNDARY
N TRACT E -- ------ - I I t
0 10' 20' 40' /,' )NING WALL(TYP HS M SS H W� � 1_ 5,
PA1lQ PROPOSED I ! I b
SINGLE FAMILY $ l I
SCALE: 1"=20' i �� I RESIDENCE oC j
q Tss euIL01Nc� LL HS 30
N
ENVELOPE
LIM
rA
i $
"R-5"Medium density residential district �+ m�.p� CMO o SS I I STORM
HS 65 I cv I STUB j sTue
Front yard:10 feet. _ =I 7D .
Side yard:5 feet for accessory structures and 5 feet for the ——20` \ o�J,
dwelling unit. N88 35 04 131.28
Street side yard:10 feet.
Rear yard:5 feet for accessory structures and 10 feet for the1' zWM
dwelling unit. HS 32
Street rear yard:10 feet. °f DEWALK
80.67' 31' 19.62' - --
05/10/2024 INSTALL SILT FENCE,
A roof overhang,chimneys,copulas,bay windows,porch covers, MSSMH STRAW WATTLE, OR
APPROVED and door landings are allowed to project a maximum of two feet N37'35'50"E FUNCTIONALLY EQUIVALENT
MASON COUNTY DCD PLANNING nto a minimum setback. 2721' L-40.0'
5(30TF RUEDY,AIC'P � R-6o.o0'
A-39'00'46"
Digitally EH APPROVED Public sewer and water
�P
smnR"eeysigned Rhonda Thompson 05/13/2024
LOT SIZE = 9,971 SF by Scott Q�
Ruedy SOIL AMENDMENT NOTE:
IMPERVIOUS "" 0/ SEE BMP T5.13 "POST CONSTRUCTION
TOTAL IMPERVIOUS: 3,499 SF(35.1%) ��/ SOIL QUALITY AND DEPTH".WSDOE
ROOF: 2,004 SF STORMWATER MANAGEMENT MANUAL
DRIVEWAY: 1,347 SF FOR WESTERN WASHINGTON.
WALK: 40 SF LOT COVERAGE = 2,004 SF(20.1%) FLAT WORK NOTE:
PATIO: 108 SF (INCLUDES EAVES) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Jo Number
Barghausen For: L E N N ^ 12® Title. b
�,,, ,•_2D• OLYMPIC RIDGE
Consulting Engineers, Inc. RESIDENTIAL SITE PLAN 21885
33455 6th Ave S, Unit 1-B, Federal Way,WA 98003
18215 72nd Avenue South (253)590-2236 LennarSeattle•Lennar.com HOMESITE 31 Shei,t
12/11/23 Kent,WA98032 Everything's included by LENNAR PARCEL NO 12328-51-00031
425.251.6222 barghausen.com Leading homebuilder of new homes 331 NE BELFAIR STATION DR,BELFAIR,WA 1 1
of
FiN:P:\21000s\21885\1ot\21885-01ympic Ridge—Plot Plane.dwg Dot,/Ti-12/6/2023 4:40 PM DBRIGGS
L�—
Name Lauren Fafnir,Agent for Lennar parcel# 12328-51-00031 BLD# /��'(�
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page I of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area * All dimensions in feet
Buildings X =
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections (example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Z_azzit'¢yL Owner/Agent/Contractor(circle one)Date:8/23/2023
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name Lauren Fafnis,Agent for Lennar Parcel# 12328-51-00031 BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
htty//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) X An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
100 W PUBLIC WORKS DR
SHELTON,WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352
615 W ALDER ST
SHELTON,WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Lauren Fafnis,Agent for Lennar Owner/Agent/Contractor(circle one)Date: 1 2/4/2023
Page 2 of 2
MASON COUNTY COMMUNITY SERVICES Permit No:
PERMIT ASSISTANCE CENTER:
// •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
615 W.Alder Street,Shelton,WA 98584
Phone Shelton:(360)427-9670 ext.352•Fax.,(360)427-7798 Phone I A 1 O 9 2024
Belfair.(360)2754467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION 615 W. Alder Sti"t 03
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: C
n...
NAME: Lennar Northwest,LLC NAME: Lennar Northwest,LLC
MAILING ADDRESS:33455 6th aye S,Unit 1-B MAILING ADDRESS: 33455 6th ave S,Unit 1-B
CTTy;Federal Way STATE:WA ZIP: 98003 CTTY:Federal Way STATE:WA ZIP: 98003
PHONE#1: (253)308-0265 PHONE: CELL: (253)308-0265 ,r.v
PHONE#2: EMAIL: Lauren.Fafnis(cr),Lennar.cotn
EMAIL:Lauren.Fafnis(aLemwxom L&I REG#LENNANL783JO EXP. 03/18)24
PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Lauren Fafnis,Agent for Lennar EMAIL Lauren.Fafnis@Lennar.com
MAILING ADDRESS 33455 6th ave S,Unit 1-B CITY Fe e� STATE WA ZIP 98003
PHONE 253 308-0265 CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12328-51-00031 ZONING
^) LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT
` SITE ADDRESS 331 NE BElfair Station Or CTTy
O DIRECTIONS TO SITE ADDRESS
C)
` IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NO E SNOW LOAD:2525_oonsf
J IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Checkall that apply):
U SALTWATER❑ LAKE❑ RT MCREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
rr 11 TYPE OF WORK: NEW E ADDITION❑ ALTERATION❑ REPAIR ElOTHER
l--L.. USE OF STRUCTURE(juw*rce,Garage,Commercial Bidg,Etc)New SFR using approved stock plan#2018-0012 Plan 2631 MF GL
IS USE: PRIMARY 14 SEASONAL❑ NUMBER OF BEDROOMS 5 NUMBER OF BATHROOMS 3
S HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Pan[s)ojBldg)® NO❑
DESCRIBE WORK New Single Family Residence heated and garage unheated
4 SQUARE FOOTAGE:(proposed)
1 ST FLOOR 1137 sq.fL 2ND FLOOR 1485 sq ft. 3RD FLOOR sq.ft. BASEMENT sq.R
` DECK sq.R COVERED DECK_sq.ft. STORAGE sq.ft OTHER - sq.ft
GARAGE 594 sq.& Attached® Detached❑ CARPORT sq.fL Attached❑ Detached❑
v /
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL,HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW® EXISTING❑
PLUMBING IN STRUCTURE? YES® NO❑ I,fyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION D S PROPOSED? YES® NO❑ EXISTING SQ.FT. 1813 sgft
EXISTING BEDROOMS PROPOSED BEDROOMS ` TOTAL BEDROOMS 5
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.1 declare that I am the owner and I further declare that I am entitled to receive this peril and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X �Q�ft/d 12/4/2023
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT JT7 - -7-W-214
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No: -0051 l
PERMIT ASSISTANCE CENTER.
BUILDING •PLANNING •FIRE MARSHAL RECEIVED
615 W. Alder St-Shelton, WA 98584
www.co.mason.wa.us
Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 MAY 0 9 2024
Phone Belfair. (360)275-4467• Phone Elma: (360)482-5269
615 W. ceder St'eet
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lennar Northwest,LLC NAME: Lennar Northwest, LLC
MAILING ADDRESS:33455 6th Ave S Unit I-B MAILING ADDRESS:33455 6th Ave S Unit 1-B
CITY: Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003
Is'PHONE: (253) 308-0265 PHONE: CELL: (253)308-0265
2°d PHONE: EMAIL : Lauren.Fafnis@Lennar.com
EMAIL: Lauren.Fafnis@Lennar.com L&I REG# LENNANL783JO EXP. 03 /18 /24
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number): 12328-51-00031 Zoning:
LEGAL DESCRIPTION(Abbreviated): Olympic
SITE ADDRESS:331 NE Belfair StationDr' T c f�lrige
CITY:
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB:
NEW x ADD ALT REPAIR OTHER USE OF BUILDING New Single Family
LOCATION OF FIXTURES/UNITS—1sT FLOOR x 2r4DFLOOR x BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric x LPG Natural Gas Ductless_
Toilets 3 Type of Unit No.of Units Fees
Bathroom Sink 4 Furnace I
Bath Tubs 1 Heat Pump 1
Showers 2 Spot Vent Fan 5
Water Heater 1 Propane Tank
Clothes Washer 1 Gas Outlets 1
Kitchen Sinks 1 Wood/Gas/Pellet Stove
Dishwasher 1 Kitchen Exhaust Hood 1
Hose bibs 2 Dryer Vent 1
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null 8 void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
12/4/2023
Signature of d2lKWner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT ZS--
PLANNING DEPARTMENT
FIRE MARSHAL
Rev: 1/27/2016 JBN