HomeMy WebLinkAboutBLD2024-00588 SFR - BLD Application - 7/23/2024 BUILDING SETBACKS:
N15'14'30'W 75.53' FRONT: 10' SIDE 5' REAR: 10'
—————336————————————————————————— TCE =INSTALL TEMP. CONST. ENTRANCE
334---------------- ————————— F�_sj =INSTALL TEMP. SOIL STOCKPILE
PROPOSED-
CONTOURS ( 04.
Z_
w
BSBL
r
(TYP) TSS R-5"Medium density residential district
Front yard:10 feet.
PATIO Side yard:5 feet for accessory structures and 5 feet for the
dwelling unit.
12 22' Street side yard:10 feet.
ear yard:5 feet for accessory structures and 10 feet for the
3rJ' dwelling unit.
1 Street rear yard:10 feet.
HS 95 1 05/10/2024
PROPOSED I APPROVED
oti MASON COUNTY DCD PLANNING
LQ SFR SCOTI RIJE72Y,AICP
N I00 1 W
1
� Digitally
signed
1 by Swu
^� t Ruedy
i
can_ N
1667MF 1 EH APPROVED
EAVE Rhonda Thompson 05/13/2024
G GEL
BUILDING
ENVELOPE ", 16' CONC. 12.22'
10`-14 DRIVEWAY PORCH 12.22' Public sewer and water
11 SS STUB
s WALK
N � v
STORM c o N SOIL AMENDMENT NOTE:
STUB TCE m SEE BMP T5.13 "POST CONSTRUCTION
SOIL QUALITY AND DEPTH", WSDOE
WM STORMWATER MANAGEMENT MANUAL
SIDEWAL FOR WESTERN WASHINGTON.
_ POWER TRANSFORMER SETBACK NOTES:
1. MINIMUM DISTANCE FROM ANY POWER
NE OLYIMMI RICX`a�' TRANSFORMER TO ANY DOOR, WINDOW, ON ALL
L=31.69' INSTALL SILT FENCE, NON—COMBUSTIBLE MATERIALS SHALL BE
R=175.00' STRAW WATTLE, OR 8—FEET.
A=10*22'28* FUNCTIONALLY 2. MINIMUM DISTANCE FROM ANY POWER
EQUIVALENT TRANSFORMER TO ANY COMBUSTIBLE WALLS OR
LOT SIZE = 7,705 SF
N15'12'45�W 55.00' ROOF SHALL BE 10—FEET.
SEPARATION NOTE:
IMPERVIOUS ANY PORTIONS OF STRUCTURES WITH LESS THAN
TOTAL IMPERVIOUS: 2,584 SF (33.5%) 10—FEET OF SEPARATION SHALL BE FIRE RATED.
ROOF: 2,220 SF
DRIVEWAY: 322 SF FLAT WORK NOTE:
WALK: 33 SF LOT COVERAGE = 2,220 SF (28.8%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 9 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Job Number Srob , —20 ° 1° 2° 40 LENNAR NORTHWEST LLC.
21885 Barghausen OLYMPIC RIDGE
Sheet Dmw„ Dnrfggs Consulting Engineers,Inc. HOMESITE 95
18215 72nd Avenue South 0 Kent,W 98032 PARCEL NO. 12328-51-00095
1 of 1 Date 6/14/23 425.251.6222 barghausen.com 71 NE OLYMPIC RIDGE, BELFAIR, WA
File:P:\21000s\21885\lot\21885—Olympic Ridge—Plot Plans.dwg Plot Date/Time:6/14/2023 3:11 PM DBRIGGS
-� yynn`
Name Lauren Fafnis,Agent for Lennar Parcel 4 12328-51-00095 BLD#�g'OQ5 V
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction, installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area `All dimensions in feet
Buildings X =
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X
X = If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Z.6u,,A� n� Owner/Agent/Contractor(circle one)Date: 12/11/2023
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read,acknowledge and sign
the information provided on page 2 of 2.
Page I of 2
Name Lauren Fafnis,Agent for Lennar parcel it 12328-51-00095 BLD# — V
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
htto//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) X An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone: (360)-427-9670 EXT.450
100 W PUBLIC WORKS DR
SHELTON,WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352
615 W ALDER ST
SHELTON,WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Lauren Fafnis,Agent for Lennar Owner/Agent/Contractor(circle one)Date: 12/11/2023
Page 2 of 2
�•` � MASON COUNTY COMMUNITY SERVICES Permit No: B Lb 0502)
PERMIT ASSISTANCE CENTER:
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL RECEIVED
615 W.Alder Street.Shelton,WA 98584
Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 Phone MAY 0 9 2024
Beffair.(360)275-4467•Phone Dina:(360)482-5269 00
BUILDING PERMIT APPLICATION C
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lennar Northwest,LLC NAME: Lennar Northwest,LLC
MAILING ADDRESS:33455 6th ave S,Unit 1-B MAILING ADDRESS:33455 6th ave S,Unit 1-B
CTTY:Federal Way STATE:WA ZIP: 98003 CITY:Federal Way STATE:WA ZIP: 98003
PHONE#1: (253)308-0265 PHONE: CELL: (253)308-0265 z
PHONE#2: EMAIL: Lauren.Fafais@Lennar.com
EMAIL:Lauren.Fafnis(alLennar.com L&I REG#LENNANL783JO EXP. 03/18/24
PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Lauren Fafnis,Agent for Lennar EMAIL Lauren Fafnis@Lennar.com
MAILING ADDRESS 33455 6th ave S,Unit 1-B CITY Fe erg STATE WA ZIP 98003
PHONE_253 08-0265 CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12328-51-00095 ZONING
Q LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT
SITE ADDRESS 71 NE Olympic Ridge CITY
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO R SNOW LOAD:2525.00 sf
\J IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (checkaAthar appty):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER tR
L USE OF STRUCTURE(neo*noe,rnww,Coe mercia tat.Etc.)New SFR using approved sots k plan bld-root Plan 1667 MF GL
X IS USE: PRIMARY SEASONAL❑ NUMBER OF BEDROOMS 4 NUMBER OF BATHROOMS 2
C®�,f HEATED STRUCTURE? YES(NholeBldgl❑ YES(Pan[r)ojB1dg)R NO❑
DESCRIBE WORK New Single Family Residence bested and garage unheated
SQUARE FOOTAGE:(propos4
1 ST FLOOR 1581 sq.ft. 2ND FLOOR sq.fL 3RD FLOOR sq.ft BASEMENT sq.ft
J DECK sq.ft COVERED DECKJ,8 sq.ft STORAGE sq.fL OTHER sq.ft
i� GARAGE 386 sq.ft Attached® Detached❑ CARPORT sq.fL Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
v/ MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW® EXISTING❑
PLUMBING IN STRUCTURE? YES® NO❑ If yes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES® NO[] EXISTING SQ.FT. 2030
EXISTING BEDROOMS jy PROPOSED BEDROOMS TOTAL BEDROOMS
=4=:=-
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X 12/11/2023
Signature of OWNER(Must be sinned by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT J TL 1-2,5- c
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No:
PERMIT ASSISTANCE CENTER.
I^n6�. BUILDING •PLANNING •FIRE MARSHAL ���'��
615 W. Alder St-Shelton, WA 98584 RECEIVED
www.co.mason.wa.us
Phone Shelton: (360)427-9670 ext. 352• Fax:(360)427-7798 MAY 0 9 2024
+ Phone Belfair. (360)275-4467• Phone Elma: (360)482-5269
615 W. Alder Sleet
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lennar Northwest,INC. NAME: Lennar Northwest,INC
MAILING ADDRESS: 33455 6th Ave S,Unit I-B MAILING ADDRESS: 33455 6th Ave S,Unit 1-13
CITY:Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003
1"PHONE:(253)308-0265 PHONE: (253)308-0265
2nd PHONE: EMAIL :Lauren.Fafnis@Lennar.com
EMAIL:Lauren.Fafnis@Lennar.com L&I REG# LENNANL783JO EXP. 03 /18 /24_
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number): 12328-51-00095 Zoning:
LEGAL DESCRIPTION(Abbreviated): Olympic Ridge
SITE ADDRESS:71 NE Oympic Ridge CITY:
DIRECTIONS TO SITE ADDRESS:
TYPE OF JOB:
NEW X ADD ALT REPAIR OTHER USE OF BUILDING New Single Family
LOCATION OF FIXTURES/UNITS— IST FLOOR X 2ND FLOOR X BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Tyne of Fixture No.of Fixtures Fees Fuel Type:Electric X LPG Natural Gas Ductless_
Toilets 2 Type of Unit No.of Units Fees
Bathroom Sink 2 Furnace
Bath Tubs 2 Heat Pump 1
Showers 2 Spot Vent Fan 4
Water Heater I Propane Tank
Clothes Washer 1 Gas Outlets
Kitchen Sinks 1 Wood/Gas/Pellet Stove 1 Fireplace/stove
Dishwasher 1 Kitchen Exhaust Hood 1
Hose bibs 1 DryerVent 1
Other SolarPanel
Other Forced Air Unit 1
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is
by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this
permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of
interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of
Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void
if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF
OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS
WILL INVALIDATE THE APPLICATION.
x Z_ae fj 12/11/2023
Signature of ner Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT 4-nZ 25-L
PLANNING DEPARTMENT
FIRE MARSHAL
Rev: 1/27/2016 JBN