Loading...
HomeMy WebLinkAboutBLD2024-00542 Repair Foundation Pin Piles, Piers - BLD Inspections - 9/17/2024 615 W.Alder St.Bldg 8,SHELTON,WA 98584 MASON COUNTY i�� SHELTON: 360-427-9670,EXT 352 COMMUNI 1 1 SER SERVICES ICES BELFAIR:360-275-4467,EXT 352 Building,Plarmuig,En ira­ tal health,Community Heald, ELMA:360-482-5269, EXT 352 -- www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY** To schedule an inspection call or visit http:/twww.co.mason.wa.us/community-services/bld-inspection.php Permit Number BLD2024-00542 Date Issued 0 611 2/2 0 24 Issued By •A-v-,,v-,_, Cv Project FOUNDATION REPAIR/STABILIZATION-PIN PILES&PUSH PIERS Site Address 70 N Cedardale Ln Applicant BAKER TERESA Contractor TERRA FIRMA FOUNDATION SYSTEM Contractor Phone 1.541.229.4050 Primary Code UPC IBC,IRC,IFC,IEC,IMC,& Type Permit Type REPAIR-RESIDENTIAL Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION,FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Building Official: Community Services Designee Department Concrete Setbacks Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches Foundation Stem Walls Other 41 eal g; _ C.&IM 9 2?1zy Rough-In Groundwork Plumbing Framing Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building R( / Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other 1(��(Zolz`l tom• s c x� wc���,,r,c� o., 3rd � �.�1 �ns�4,r,�, 2t,p,,�— Eoo-1 "r ok, 8(�a l zN �Ck �d�1c-u��1 SY� ��; par►- �5/d Pc-`rI WKS lac' +'V'n 1, �O't Ake, INSPECTION RESULTS Pagel AIIIIIIIIIIIIA Department of Community Development fIZA MASON COUNTY COMMUNITY SERVICES 615 W Alder St,Shelton,WA 98584 (360)427-9670 Application# BLD2024-00542 Application REPAIR-RESIDENTIAL Application# BLD2024-00542 Parcel# 422125110503 Site Address 70 N Cedardale Ln Hoodsport,WA 98548 8-20-24-JQ Joshua Quarders FOOTING INSPECTION CONDITIONA Footings ok this date/waiting on the 3rd party reports L please send prior to cover per approved plan pg S0.0 in red GENERAL OBSERVATIONS AWAITING INSPECTION Description Status Status Date Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2024-00542 REPAIR:RESI:D:ENTIAL PROJECT DESCRIPTION: FOUNDATION REPAIR/STABILIZATION - 2024PIN PILES& PUSH PIERS SITE ADDRESS: 70 N CEDARDALE LN HOODSPORT E2024 PARCEL: 422125110503 APPLICANT: BAKER TERESA OWNER: THOMPSON ET UX SHAINA GRACE 70 N CEDARDALE LN TERESA MARIE BAKER HOODSPORT,WA 98548 HOODSPORT,WA 98548 424-382-3684 CONTRACTOR: TERRA FIRMA FOUNDATION SYSTEM 10111 S TACOMA WAY STE D4 LAKEWOOD,WA 98499 1.541.229.4050 GENERAL CONTRACTOR'S LICENSE: TERRA FIRMA FOUNDATION SYSTEM License: TERRAFR931LH 10111 S TACOMA WAY STE D4 Expires: 06/16/2025 LAKEWOOD,WA 98499 1.541.229.4050 VALUATIONS: FEES: Paid Due Project Valuation (BID, 30471.96 $30,471.96 Technology Surcharge $16.04 $O:Do ESTIMATION..) Building Permit Fee $485.92 $0.00 Plan Check Fee $315.85 $0.00 State Fee-Residential $6.50 $0.00 Planning Review Fee $240.00 $0.00 Total: $30,471.96 Totals : $1,064.31 $0.00 REQUIRED INSPECTIONS 3rd Party Inspection Report BLD-Final Inspection CONDITIONS * Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. Printed by:Anna Schaffran on:06/12/2024 10:44 AM Page 1 of 3 r [ Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov REPAIR - RESIDENTIAL BLD2024-00542 * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. * All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant one or more extension of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicate that circumstances beyond the control of the permit holder prevented action from being taken. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. Printed by:Anna Schaffran on:06/12/2024 10:44 AM Page 2 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncoun"a.gov REPAIR - RESIDENTIAL BLD2024-00542 * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Code 14.28 and 14.17. • Project must conform with recommendations of Geotechnical report (GE02024-00048). " In addition to the inspections required in IBC,Section 110, the owner, the engineer or architect of record acting as the owner's agent shall employ one or more special inspectors who shall provide inspections during construction on the types of work listed under Chapter 17 and as specified by the design professional. The special inspectors duties&responsibilities shall be as specified in Chapter 17. Special inspection reports shall be submitted to the Mason County Building Department, 615 W Alder St, Shelton WA 98584 and available for inspection. Inspection reports shall be completed and submitted to the dept. in a timely manner and shall be submitted prior to the framing and final occupancy inspections. PILE DRIVING " Owner shall provide pile drivers report on all piles.Any pile supporting structure and over 10' in height from floor of body of water shall require engineered design and special inspection. Engineer of record (or certified special inspector)shall provide verification at time of inspection that piles are driven to point of refusal and/or installed per design. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent. Date: Printed by:Anna Schaffran on:0611212024 10:44 AM Page 3 of 3 DocuSign Envelope ID: D8D2B1 F8-6130-4DB5-B1 EA-60803EA55EC8 Special Inspection Requirements MASON COUNTY COMMUNITY SLRVIUS BLD2024-00542 Baker 123335 70 N Cedardale Ln Permit Number Project Title Project Address/Parcel Number Applicants of projects requiring Special Inspection or Testing per Chapter 1704&1705 of the International Building Code, as amended by Washington State. Please acknowledge and return this form to the Mason County Permit Center. THESE INSPECTIONS ARE NOT PERFORMED BY THE BUILDING DEPARTMENT AND MUST BE PERFORMED BY QUALIFIED SPECIAL INSPECTORS, HIRED BY THE OWNER AND APPROVED BY THE COUNTY PERMIT CENTER. Individuals certified in a special inspection category by Washington Association of Building officials(WABO) or individuals employed by a recognized testing laboratory and under the direct supervision of a Registered Professional Engineer are typically considered qualified at the discretion of the local jurisdiction having authority for enforcement. BEFORE A PERMIT CAN BE ISSUED: The Owner or his/her representative, on the advice of the responsible Project Engineer or Architect, shall fill out completely, sign and submit two (2) copies of the attached "Structural Tests and Inspection Schedule"to this Department for review and approval including any requirements related to the Mason County Municipal Code. The Owner, General Contractor, and Inspection/Testing Agency, where applicable, shall also acknowledge the following conditions applicable to Special Inspection and/or Testing. 1. Inspection/Testing Agency shall submit names and qualifications of on-site Special Inspectors to the Building Inspection Permit Center for approval PRIOR TO PERMIT/S BEING ISSUED. 2. All Special Inspections shall be noted on the approved plans or attached approved documents. 3. All special inspections shall be approved by the County or as recommended by the Engineer of Record (EOR). 4. It is the responsibility of the General Contractor to review County approved plans for additional inspection or testing requirements that may be noted or required per IBC as noted on approved plans. 5. The General Contractor is responsible for proper notification to the Inspection/Testing Agency for items listed on this form. 6. Special Inspectors shall provide detailed reports on company letterhead to the Building Inspector of all required inspection activities. These may also be provided when the inspector visits the jobsite for the scheduled inspection but must be completed before the subject of inspection is approved by the building inspector. 7. Copies of all ongoing laboratory and testing reports shall be sent directly to the Building Inspector by the Inspection/Testing Agency or other responsible party within a reasonable time to test results. 8. BEFORE A CERTIFICATE OF OCCUPANCY APPROVAL CAN BE ISSUED: The Inspection/Testing Agency shall submit a FINAL REPORT LETTER stating that all items requiring testing and inspection have been fulfilled and reported and a final inspection report shall be provided. A copy of the statement is to be maintained at the jobsite for the Building Inspectors review prior to final inspections. Page 1 of 4 DocuSian Envelope ID:D8D2B1 F8-6130-4DB5-B1 EA-60803EA55EC8 Special Inspection Requirements MASONCOUNIY COMMUNf1Y SERVICES ACKNOWLEDGEMENTS Prior to issuance of a building permit, the Owner, on the advice of the Project Engineer or Architect, shall complete,sign,and submit this form to the County Permit Center. Declaration of Owner I,as the owner of the project,declare that the testing agency firm/s or individual/s listed herein are hired by me to perform "Special Inspections" and/or "Structural Testing" in accordance with the provisions of the International Building code(IBC) Chapter 17. P-UGWAdW. Teresa Baker Li4Mr'Ti"dndture) bakx 6/5/2024 11:36:43 A Owner(print) (date) Declaration of Registered Professional Architect/Engineer I, as the design professional in responsible charge of the project listed herein, declare that the special inspection listed herein are required for this project in accordance with the provisions of the International Building Code(IBC) Chapter 17. Dennis Heier csM 1 Architect/Engineer(print) s x Architect/Engineer Stamp/Signature(date) 4 06/04 Vista Structural Engineering, LLC Testing Agency Name/Contact ��Wgif Wgpection by EOR) info: 971-233-6098 The Special Inspection/Testing Agency listed above must have a current Portfolio of Qualifications on file with the County prior to performing work. Declaration of the General Contractor I,as the General Contractor of the project,agree to comply with the"Contractor Responsibility"items noted herein. Ashley Haney � � 6/5/2024 General Contractor(print) General Contractor Signature (date) Page 2 of 4 DocuSion Envelope ID: D8D2B1F8-6130-4DB5-B1EA-60803EA55EC8 S p al Inspection Requirements MASON COUNTY COMMUNITY SERVICES Required Special Inspections International Building Code; Chapter 17: A completed and signed copy of pages 1 through 4 of this form shall be submitted to the "Permit Center" prior to building permit approval. Engineer shall check the applicable items: ❑ Special inspection of fabricated items 1704.2.5 ❑ Submittals to the building official 1704.5 ❑ Structures over 75' in height located in Seismic Design Category D, 1704.6.1 ❑ Structures classified as Risk Category III or IV located in Seismic Design Category D, 1704.6.1 ❑ Steel construction& structural Steel 1705.2.1 ❑ Cold form steel deck 1705.2.2 ❑ Open-web steel joists & girders 1705.2.3 ❑ Cold form steel trusses spanning 60 feet or greater 1705.2.4 ❑ Concrete construction 1705.3 &Table 1705.3 ❑ Shotcrete 1705.3 ❑ Welding of reinforcing bars 1705.3.1 ❑ Material Tests 1705.3.2 ❑ Masonry Construction 1705.4 ❑ Empirically designed masonry, glass unit&masonry in Risk Category IV 1705.4.1 ❑ Vertical masonry foundation elements 1705.4.2 ❑ Wood construction 1705.5 ❑ High Load Diaphragms 1705.5.1 ❑ Metal-plate connected wood trusses spanning 60 feet or greater 1705.5.2 ❑ Soils 1705.6 &Table 1705.6 El Driven deep foundations 1705.7 &Table 1705.7(PERIODIC UNDER PROVISIONS OF THE IRC) ❑ Cast in-place deep foundations 1705.8 &Table 1705.8 ❑ Helical pile foundations 1705.9 ❑ Fabricated items 1705.10 Page 3 of 4 DocuSicgn Envelope ID:D8D2B11`8-6130-41D85-131EA-60803EA55EC8 Special Inspection Requirements MASON COUNTY COMMUNITY SERVICES ❑ Special inspections for wind resistance 1705.11 ❑ Structural wood 1705.11.1 ❑ Wind resisting components 1705.11.3 ❑ Cold formed steel light frame 1705.11.2 ❑ Special inspection for seismic resistance 1705.12 ❑ Special inspection for structural steel per 1705.12.1 ❑ Seismic force-resisting systems 1705.12.1.1 ❑ Structural steel elements 1705.12.1.2 ❑ Special inspection for structural wood per 1705.12.2 ❑ Special inspection for cold-formed steel per 1705.12.3 ❑ Designated seismic systems 1705.12.4 ❑Architectural components 1705.12.5 ❑ Plumbing,mechanical& electrical components 1705.12.6 ❑ Storage racks 1705.12.7 ❑ Seismic isolation systems 1705.12.8 ❑ Cold-formed steel special bolted moment frames 1705.12.9 ❑Testing for seismic resistance 1705.13 ❑ Structural steel 1705.13.1 ❑ Seismic fore-resisting systems 1705.13.1.1 ❑ Structural steel elements 1705.13.1.2 ❑Nonstructural components 1705.13.2 ❑ Designated seismic systems 1705.13.3 ❑ Seismic isolation systems 1705.13.4 ❑ Sprayed fire-resistance materials 1705.14 ❑Physical and visual tests 1705.14.1 ❑ Structural member surface conditions 1705.14.2 (1705.14.3 through 1705.14.6.3) ❑ Mastic & intumescent fire-resistance costings 1705.15 ❑ Exterior insulation&finish systems(EIFS) 1705.16 ❑ Fire-resistance penetrations and joints 1705.17 ❑Penetration firestops 1705.17.1 ❑Fire-resistant joint systems 1705.17.2 ❑ Testing for smoke control 1705.18 ❑ Testing Scope 1705.18.1 Page 4 of 4 Portland,Oregon R V 1 S T A Kansas City, Missouri � ay —STRUCTURAL— 8/27/2024 TerraFirma Foundation Systems 10111 S Tacoma Way D5 Tacoma,WA 98499 Re:70 Cedardale Ln. Hoodsport,WA 98548 Permit#: BLD2024-00542 Final Summary Letter: This letter certifies that we have performed an inspection of the above-referenced project with respect to the approved structural plans dated January 3, 2024 and revised July 22, 2024. Note that push pier#1 was installed as drawn on the original drawing, per installer. On August 19,2024,a representative of Vista Structural Engineering, LLC observed the installation of one Foundation Supportworks Incorporated model PP288 push pier and two model PP237 pin piles (periodic inspection per adopted code). In addition,Vista Structural Engineering, LLC has examined the job photos,drive logs and pier locations as provided by TerraFirma Foundation Systems and approves of the installation means and methods for this project. All push piers and pin piles reached or exceeded the plan specified minimum installation depth and pressure or refusal. Inspection has been provided in an effort to meet the requirements of the building code and does not constitute a guarantee of the installed work. It is the responsibility of the contractor to execute the work in accordance with the approved structural drawings. On-site inspections were not performed by Vista Structural Engineering, LLC. Our firm appreciates the opportunity to serve you. If you have any questions or if you need anything further, please feel free to contact us. Sincerely, Vista Structural Engineering, LLC LS M Dennis Heier, P.E. f' x 08/27/2 VISTA STRUCTURAL ENGINEERING, LLC 11575 SW Pacific Hwy#2262 PHONE: 971.233.6099 Tigard, OR 97223 - 1 - VISTASTRUCTURAL.COM i - ri�rllrr y'0 a, r'r t xt d c S° tip k ! Yz .L. .. 4 yam. 1. f-tri r x r�� � �f'��F�rF S ✓ P���•, `�` ii �� •�� f �7�[j�;"F ;•,. X�,��y��.f'; of ` r '✓,>, t /"`� ,r r,�h. * t`.rl`,3iv {. ✓F ,P.`�.Yts�.f�L•",x.A; t.'6'I`r.''' S 3i 4 � ; ; Ul .Ern 5 � a ti F� ��T,�.� �a17*=w LL.al+� Yam+' `• � _ A n .tea m r � '� j k L.. ..� � r��„y,�aw ,� < .P,;,. . Y�� � ��� F, .�,.�rbx s„L'..�, �� ��i „{� s 7fC 4 yy ,� _ __ �:� . - �lMw� � � � i�� ¢- �, �f T----- ,� �..... �� � '� I ♦ 1 !" �,Y� - __ . ._