HomeMy WebLinkAboutCOM2014-00175 Final Furnace - COM Permit / Conditions - 5/5/2015 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
�P90 cootirl
Mason County Bldg. III Phone: (360)427-9670, ext. 352
426 W. Cedar
Shelton, WA 98584
AS4
COMMERCIAL BUILDING PERMIT COM2014-00175
OWNER: BELFAIR LOG PLAZA LLC RECEIVED: 12/1/2014
CONTRACTOR: INTERSTATE INDUSTRIES INC 206.387.2364 LICENSE: INTERII873D7 EXP: 3/27/2015 ISSUED: 1/7/2015
SITE ADDRESS: 23730 NE STATE ROUTE 3 SUITE C BELFAIR EXPIRES: 7/7/2015
PARCEL NUMBER: 123294400010
LEGAL DESCRIPTION: TR 1 OF SE SE S 1/124
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Furnace, spot vent fans, gas outlets, 2-type I exhaust hood
General Information Construction&Occupancy Information
No. of Units: Type of Constr.:
Type of Use: Insp.Area: No. of Bathrooms: Occ. Group: q
Valuation:Type Work: MEC Fire Dist.: 5 No. of Stories: Exit Design. Load:
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline&Planning Information
Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPA?: Comp. Plan Desig.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2014-00175 Please refer to the following pages for conditions of this permit. Page 1 of 6
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Exhaust Hood 2 Mechanical Base Fee rN 19i10MA T,9R sn c1gnlrnn
Furnace<100K 1 Plan Check Fee ni r. 19/11/gn1. All nn g1gn1x;nn
Gas Outlets 4 Non-Res. Energy Code ni r 17/11/?n1. T,7A nn S1gn15nn
Ventilation Fan 2 Building State Fee ni r. 19i11/9n1, ad Fn S1gn1rnn
Building Permit Fee ni r. 1gi11nn1. 4t1d1 nn g1gn1rno
Mechanical Permit Fee ni r. 17/11/7n1. -tRR Qn g17n1rnn
Total $388.90
CASE NOTES FOR
COM2014-00175
CONDITIONS FOR
COM2014-00175
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X "I W 1
2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title
14.28.
X W1 yy,\
3) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND OCCUPANCY
IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD RESULT IN PERMIT
REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x M yv-\
4) The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation) of any structure unless all asbestos containing materials have
been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the
owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623
www.orcaa.org
X re-N
COM2014-00175 Page 2 of 6
5) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE
ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in
conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a
Mason County Building Inspector shall be made prior to requesting additional inspections.
X \�'\M
6) If the tank size is between 125 and 500 gallons you must follow these guidelines: 1. Tank is to be 10 feet from any buidling, public way or property
line. 2. If the tank is exposed to probable vehicular damage, provide protective bollards. 3. All weeds, grass, brush, trash and other combustible
material shall be kept a minimum of 10 feet away from LP containers. X 'MYV-"\
7) New and replaced heating equipment shall meet the requirements of the Internation Energy Conservation Code as amended Washington State
Energy Code (WSEC), and applicable sections of the IBC and IMC. All new or replaced heating equipment shall meet the efficiency requirements
of WSEC C403.2.3.
Those parts of heating systems that are altered or replaced shall comply with the current Washington State Energy Code (WSEC), Section
C101.4.3.2. When a space-conditioning system is altered by the installation or replacement of space conditioning equipment(including
replacement of the air handler, outdoor condensing unit of a split system air conditioner or heat pump, cooling or heating coil, or the furnace heat
exchanger), the duct system that is connected to the new or replacement space-conditioning equipment shall be installed and sealed in
accordance with C403.2.7.
All new and replaced heating equipment shall comply with WSEC Section C403. Heating and design load calculations for the purpose of sizing
HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Provide design
calculations during inspection.
Referencing WSEC C403.2.7 and IMC Chapter 6, all new ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems.
Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for
mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and
shall be marked 181 B-FX for pressure-sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or
sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and
shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically
fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork
shall be installed in accordance with the manufacturer's installation instructions.
Duct tape is NOT permitted as a sealant on any new duct systems. When new ducts are located in unheated spaces the ducts shall be insulated to
R-8
8) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-compliant with Mason County ordinances and building regulations.
X ffi YY1
9) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the
time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control
of the permit holder have prevented action from being taken. No more than one extension may be granted.
X Mrn
COM2014-00175 Page 3 of 6
10) All commercial kitchen hood systems shall be protected with a UL300 compliant automatic fire extinguishing system installed in accordance with
manufacturer specifications and maintained as required by the 2012 International Fire Code, Building Code, and International Mechanical Code.
The fire extinguishing system shall require a separate fire protection permit and approval prior to installation. The system shall be inspected and
tested for proper operation at 6-month intervals unless approved otherwise. Maintenance records shall be available for inspectors during
inspections.
Commercial kitchen grease ducts shall be constructed in accordance with the International Mechanical Code (IMC) Section 506 with steel material
16g or better, stainless material 18g or better, or materials listed and labeled in accordance with UL1978. Kitchen grease ducts and exhaust
equipment shall have a clearance to combustible construction of not less than 18-inches and a clearance to noncombustible construction and
gypsum wallboard attached to noncombustible structures of not less than 6-inches. (Ref IMC 506)
X W n/1
11) Makeup air shall be provided during operation of commercial kitchen exhaust systems in accordance with the 2012 International Mechanical Code
Section 508. The amount of makeup air supplied to the building from all sources shall be approximately equal to the amount of exhaust exhaust air
for all exhaust systems for the building withou reducing the the effectiveness of the exhaust system. The makeup air shall not have a temperature
differential greater than 10 degrees Fahrenheit between the makeup air and air in the conditioned space. Makeup air systems shall be
automatically controlled to start and operate simultaneously with the exhaust system.
x mnn
12) This permit is approved to install 2-type I commercial kitchen hoods, an air handler for make-up air, gas outlets and ventilation fans. A separate
permit shall be required for the fire suppression system required for the type I exhaust hoods.
X 1��M
13) Install 2A10BC fire extinguishers throughout the building in accordance with chapter 9 of the 2012 International Fire code. The fire extinguishers
shall be installed such that the extingishers are located not more than a travel distance of 75 feet in any direction and mounted no more than 60
inches above floor to the top of the unit. At least one extinguisher is required on every level or floor. -
Not less than 1 type K portable fire extinguisher shall be located in the commercial kitchen area, within 30 feet of the cooking appliances and no
closer than 10 feet.
X YV\ m
COM2014-00175 Page 4 of 6
OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by
signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the
work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null &void if work or authorized construction is not commenced within 180 days or if
construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT PLICATION OF 80 YS WILL INVALIDATE THE APPLICATION.
( Z C) t
Signature Date
Mo•r1SSA �� � �1-� OWNER - REPRESENTATIVE - CONTRACTOR
Print Name (Circle one to indicate)
COM2014-00175 Page 5 of 6
�uU4, MASON COUNTY � ' PERMIT NOLDK)
DEPARTMENT OF COMMUNITY DEVELOPMENT 1 C
BUILDING•PLANNING d,FIRE MARSHAL I
WWW.CO.MASON.WA.US (360)427-9670 Shelton ext.352
Mason County Bldg. 111,426 West Cedar Street (360)275-4467 Belfair ext.352
PO Box 279,Shelton,WA 98584 (360)482-5269 Elma ext.352
PLUMBING & MECHANICAL PERMIT APPLICATION
OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME:_ 1-cq 1�\aZ�-I L1.C� _ NAME:
j MAILING ADbRESS:_-712,. ,vG Nc t1'1 `mot - MAILING ADDRESS: \Z\1 N\1n 1wc t' 1G3
CITY: 15 STATE: 1 ` Z -1�t 1G CITY: STATE: \N ZIP: cist?
PHONE:_'W 1 I - L_iN1lCELL: OI`S c) PHONE: 20L 3�s-1-��1,4CELL: �14 L Ici L
EMAIL: �(�5 nk i a \Vl CC:� EMAIL : ',►�ktr�Fc, i�c,�'�ky�c��1 411L � �.b�xul,t.�.t�
L&I REG# EXP. T/ /
PARCEL INFORMATION:
PARCEL NUMBER(12 DIGIT NUMBER):
LEGAL DESCRIPT ION(ABBREv1ATED): 'ct u c PL L tiq 5: 15-2 7-
SITE ADDRESS: ???13-v'AWwc�y F2 CITY: •\ L `-li�->2_
DIRECTIONS TO SITE ADDRESS:
-------------- ---------------
TYPE OF JOB
NEW ADD ALTO_REPAIR OTHER USE OF BUILDING
LOCATION OF FIXTURES/UNITS—1 ST FLOOR_2ND FLOOR BASEMENT GARAGE OTHER
PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS
Type of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas )4- Ductless_
Toilets Type of Unit No.of Units Fees
Bathroom Sink Furnace
Bath Tubs Heat Pump
Showers Spot Vent Fan _
Water Heater Propane Tank
Clothes Washer Gas Outlets
Kitchen Sinks Wood/Gas/Pellet Stove
Dishwasher Kitchen Exhaust Hood
Hose bibs Dryer Vent
Other Solar Panel
Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare
that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including
any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is
accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This
permit/application becomes null 8 void if work or authorized construction is not commenced within 180 days or if construction work Is
suspended for a period of 180 days.PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION.INACTIVITY OF THIS
PERMIT APPLI 7,
ATION OF 190 DAYS WILL INVALIDATE THE APPLICATION.
x `&-41 y
Sign n Date
x '-A-y ALL tiAOwner/Owners Representative/Contractor
Print Nam (indicate which one)
DEPARTMENTAL REVIEW,_-_ APPBPVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT 2• I)-
PLANNING DEPARTMENT
FIRE MARSHAL