HomeMy WebLinkAboutBLD2024-00451 SFR - BLD Application - 5/8/2024 L=52.10' BUILDING SETBACKS:
FRONT: 10' SIDE: 5' REAR: 10'
R=2,804.93'
A=01'03'51"
TCE =INSTALL TEMP. CONST. ENTRANCE
- - - - - 354- - -
T =INSTALL TEMP. SOIL STOCKPILE
PROPOSED SS
CONTOURS Z--"" 0
EH APPROVE
Rhonda Thompson 04/12/2024
rr
N Tss Public sewer and water
BSBL "R-5"Medium density residential district
(TYP)
Front yard:10 feet.
Side yard:5 feet for accessory structures and 5 feet for the
dwelling unit.
01 Street side yard:10 feet.
z Rear yard:5 feet for accessory structures and 10 feet for the
PATIO dwelling unit.
16.14'
Street rear yard:10 feet.
_ 5'
40' 04/09/2024
w APPROVED
HS 75
MASON COUNTY DCD PLANNING
PROPOSED
SCOTf RUEDVAICP
SFR
Digitally
UJ
(" m Scott Ruedy
5.69' b signed Scott
_ _ y
to oN Ruedy
2439MF ' z
o EAVE GARAGE L
BUILDING
ENVELOPE 32, 27' CONC.
DRIVEWAY 5
Iv 15.28 — POR Ut. ...'; 5' _
N SS STUB
-- — -- - ;.
— — - AL.' — — STORM �„
A roof overhang,chimneys,copulas,bay windows,porch covers,
(CT1 STUB and door landings are allowed to project a maximum of two feel
TCE (n into a minimum setback.
--
MTCEM POWER TRANSFORMER SETBACK NOTES:
Z; ,,SIDEWALK 1. MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY DOOR, WINDOW, ON ALL
NE OLYMPIC RIDGE NON-COMBUSTIBLE MATERIALS SHALL BE
8-FEET.
L=49.91'
R=2,689.93' INSTALL SILT FENCE, 2. MINIMUM DISTANCE FROM ANY POWER
A=01'03'47" STRAW WATTLE, OR TRANSFORMER TO ANY COMBUSTIBLE WALLS OR
FUNCTIONALLY EQUIVALENT ROOF SHALL BE 10-FEET.
LOT SIZE = 6,030 SF
SEPARATION NOTE:
IMPERVIOUS ANY PORTIONS OF STRUCTURES WITH LESS THAN
TOTAL IMPERVIOUS: 2,498 SF (41.4%) 10-FEET OF SEPARATION SHALL BE FIRE RATED.
ROOF: 1,848 SF
DRIVEWAY: 502 SF FLAT WORK NOTE:
WALK: 40 SF LOT COVERAGE = 1,848 SF (30.6%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PATIO: 108 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
Job Number 0 10 20 40
21885 safe '"-20'
LENNAR NORTHWEST LLC.
Barghausen OLYMPIC RIDGE
Sheet Drown Dbriggs Consulting Engineers,Inc. HOMESITE 75
18215 72nd Avenue South
Kent,w 98032 PARCEL NO. 12328-51-00075
1 of 1 Date 5/30/23 425.251.6222 barghausen com 271 NE OLYMPIC RIDGE. BELFAIR, WA
File:P:\21000s\21885\lot\21885—Olympic Ridge—Plot Plons.dwg Plot Date/Time:5/30/2023 9:19 AM D9R G5
Name Sam Martin,Agent for Lennar Parcel# 12328-51-00075 BLD# (� o
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 1 of 2)
Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is
made for residential development, or redevelopment',with more than 2,000 square feet of impervious surface 2.
'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development
including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not
part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment.
'Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas,
concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the
natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces.
To Calculate Impervious Surfaces Please Complete This Table
Surface Type Length X Width = Area *All dimensions in feet
Buildings X =
X = Measurements for buildings are taken at the
X _ perimeter of the farthest projections(example:
eaves/gutters)
X =
Driveways X =
X = Length of drive begins at the right of way
X =
Parking Areas X =
X = Any paved, gravel or packed area per definition
above table
X =
Patios/Walks X =
X = Any paved, gravel or packed area per definition
above table
X =
Others X =
X If the total impervious area of the proposed site
X = development is greater than 2000 square feet a
Small Parcel Stormwater Site Plan is Required
Total Impervious Surface Area (sum of all areas)
If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below.
Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X �G.hYL W� Owner/Agent/Contractor(circle one)Date: 8/9/2023
If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read,acknowledge and sign
the information provided on page 2 of 2.
Page 1 of 2
Name Sam Martin,Agent for Lennar Parcel# 12328-51-00075 BLD#
Mason County
Department of Community Development
Small Parcel Stormwater Management Application/Worksheet (page 2 of 2)
Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity.
Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater
Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website:
http//www.co.mason.wa—us/code/commissioners/index.htm
Please follow the links to"Title 14,Chapter 14.48 Stormwater Management".
Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan
(Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document
entitled"Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist
you in preparing the necessary information and plans for Public Works to review and approve. Per Department of
Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in
their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health
information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval.
A design by a registered professional may be required for more complex sites.
*These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan
on the pages that begin with"Handout"
PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE
A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed
in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel.
B) X An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the
system will be located as not to adversely affect any septic systems on this,or any other,parcel.
If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works
Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at:
Phone:(360)-427-9670 EXT.450
100 W PUBLIC WORKS DR
SHELTON,WA 98584
If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of
Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or
any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason
County Division of Environmental Health can be reached at:
Phone:(360)-427-9670 EXT.352
615 W ALDER ST
SHELTON,WA 98584
A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met
prior to a request for final inspection of the building permit.
Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I
further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above-
described property for review and inspection as may be required.
X Sam Martin,Agent for Lennar Owner/Agent/Contractor(circle one)Date: 8/9/2023
Page 2 of 2
Azi
• MASON COUNTY COMMUNITY SERVICES Permit No:. L S �/
• PERMIT ASSISTANCE CENTER: RE C E 1y w kE D
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL �;�
615 W.Alder Street,Shelton,WA 985&4
• Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone APR 0w��l
Belfair.(360)2754467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION 615 W. Alder Sheet Ili...
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lennar Northwest,Inc. NAME: Lennar Northwest,Inc.
MAILING ADDRESS:_33455 6th aye S,i Tnit 1-11 MAILING ADDRESS: 33455 6th Ave S,Unit 1-B �u
CITY: Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003 Z
PHONE#1: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322
PHONE#2: EMAIL: Sam.Martin(Zd,Lennancom
EMAIL: Sam.Martin(&j ennar.com L&I REG# LENNANL783JO EXP. 03 /18/24
PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Sam Martin EMAIL Sam.Martin@Lennar.com
MAILING ADDRESS 33455 6th Ave S.Unit 1-B CITY Federal Way STATE WA ZIP 98003
PHONE (253)294-1322 CELL (253)294-1322
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12328-51-00075 ZONING
LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT
SITE ADDRESS 271 NE Olympic Ridge CITY Belfair
DIRECTIONS TO SITE ADDRESS 01 ywk p�+Z
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES❑ NOR SNOW LOAD:25 OOosf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW R ADDITION❑ ALTERATION❑ REPAIR❑ OTHER R
M USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.)New SFR using approved stock plan 42018-0033 Plan 2439 MF GL
1M1 IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS 4 NUMBER OF BATHROOMS 2.5
HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Partls]ofBidg)® NO❑
Q) DESCRIBE WORK New Single Family Residence heated and garage unheated
1 SOUARE FOOTAGE:(proposed)
1 ST FLOOR 989 sq.ft. 2ND FLOOR 1351 sq.ft. 3RD FLOOR sq.ft BASEMENT sq.ft
d DECK sq.ft. COVERED DECK_5ff_sq.ft STORAGE sq.ft OTHER_- sq.ft.
GARAGE 591 sq.ft. Attached� Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
J (� MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER R / NEW R EXISTING❑
PLUMBING IN STRUCTURE? YES R NO❑ !Eyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES R NO[] EXISTING SQ.FT. 1630 sqft
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.1 declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permitlapplicabon becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
x �5a4,1,7ea,t, 8/3/2023
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
MASON COUNTY COMMUNITY SERVICES Permit No: L - 0J/
PERMIT ASSISTANCE CENTER:-BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL R E ��/[r',C E y },,,,P.
Iy 615 W.Alder Street,Shelton,WA 98584
\ Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone APR 0 3 V `;
Belfair.(360)275-4467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION 615 W. A1dar Street
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Lennar Northwest,Inc. NAME: Lennar Northwest.Inc.
MAILING ADDRESS: 33455 6th aye S,iinit 1-B MAILING ADDRESS: 33455 6th Ave S.Unit 1-B
CITY: Federal Way STATE: WA ZIP: 98003 CITY: Federal Way STATE: WA ZIP: 98003
PHONE#1: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322 �+
PHONE#2: EMAIL: Sam.Marti Afennar.com
EMAIL: Sam.Martin(aJLennar.com L&I REG#LENNANL783JO EXP. 03 /18/24
PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER
NAME Sam Martin EMAIL Sam.Marbn@Lennar.com
MAILING ADDRESS 33455 6th Ave S.Unit 1-B CITY Federal Way STATE WA ZIP 98003
PHONE (253)294-1322 CELL (253)294-1322
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) 12328-51-00075 ZONING
LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT
SITE ADDRESS 271 NE Olympic Ride CITY Belfair
DIRECTIONS TO SITE ADDRESS plvr"Fi c. q Z
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO® SNOW LOAD:25.00nsf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Checkandwapply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
~ TYPE OF WORK- NEW® ADDITION❑ ALTERATION❑ REPAIR❑ OTHER
M USE OF STRUCTURE(Res dense,Garage,Commercial Bldg,Etc.)New SFR using approved stock plan 42018-0033 Plan 2439 MF GL
1 IS USE: PRIMARY❑ SEASONAL❑ NUMBER OF BEDROOMS 4 NUMBER OF BATHROOMS 2.5
vHEATED STRUCTURE? YES(WIw1eBW❑ YES(Part[s)ofBldg)® NO❑
DESCRIBE WORK New Single Family Residence heated and garage unheated
I SQUARE FOOTAGE:(proposed)
I ST FLOOR 989 sq.ft. 2ND FLOOR 1351 sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
O DECK sq.ft. COVERED DECK-0 sq.ft. STORAGE sq.ft OTHER _ sq.ft.
(� GARAGE 591 sq.& Attached g Detached❑ CARPORT sq.ft Attached❑ Detached❑
n7 MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
J (� MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER® / NEW® EXISTING❑
PLUMBING IN STRUCTURE? YES R NO❑ I,fyes,attach completed Water Adequacy Form
PERIMETERNOUNDATION DRAINS PROPOSED? YES® NO❑ EXISTING SQ.FT. 1630 scift
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further dedare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project, The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
x �5'a �;L 8/3/2023
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CON)MONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL