Loading...
HomeMy WebLinkAboutBLD2024-00500 SFR - BLD Application - 6/3/2024 BUILDING SETBACKS: EH APPROVED N 15'14'30"W 50.00' FRONT: 10' SIDE: 5' REAR: 10' Rhonda Thompson 0M23/202a Public sewer and water TCE =INSTALL TEMP. CONST. ENTRANCE ___34b— FTssl =INSTALL TEMP. SOIL STOCKPILE --- —_344-- I PROPOSED CONTOURS I I BSBL A roof overhang,chimneys,copulas,bay windows,porch covers, d door landings are minimum setback.lowed to project a maximum of two feet (TYP) into a TSS "R-5"Medium density residential district Front yard:10 feet. Side yard:5 feet for accessory structures and 5 feet for the dwelling unit. PATIO Z Street side yard:10 feet. Rear yard:5 feet for accessory structures and 10 feet for the dwelling unit. 9' 6' Street rear yard:10 feet. 35 04/22/2024 I S �� APPROVED MASON COUNTY DCD PLANNING H i PROPOSED SCotf RUEQVAfeP °O SFR Digitally signed +� °UJI I s by Scott Ruedy z 11217A I EAVE GARAG R BUILDING ENVELOPE 9' 16' CONC. 9' PORCH DRIVEWAY 6' I STORM S STU WALK �, — o STUB _So-__ rr, No SOIL AMENDMENT NOTE: 1 — � SEE BMP T5.13 "POST CONSTRUCTION c o _344i SOIL QUALITY AND DEPTH", WSDOE TRANSFORMER TCE STORMWATER MANAGEMENT MANUAL - FOR WESTERN WASHINGTON. WMW POWER TRANSFORMER SETBACK NOTES: SIDEWALK, 3 1. MINIMUM DISTANCE FROM ANY POWER TRANSFORMER TO ANY DOOR, WINDOW, ON ALL INSTALL SILT FENCE, NE OLYMPIC RIDGE NON—COMBUSTIBLE MATERIALS SHALL BE STRAW WATTLE, OR 8—FEET. FUNCTIONALLY 2. MINIMUM DISTANCE FROM ANY POWER EQUIVALENT N15'12'45'W 50.00' TRANSFORMER TO ANY COMBUSTIBLE WALLS OR ROOF SHALL BE 10—FEET. LOT SIZE = 5,949 SF SEPARATION NOTE: IMPERVIOUS ANY PORTIONS OF STRUCTURES WITH LESS THAN TOTAL IMPERVIOUS: 2,163 SF (36.4%) 10—FEET OF SEPARATION SHALL BE FIRE RATED. ROOF: 1,813 SF DRIVEWAY: 308 SF FLAT WORK NOTE: WALK: 33 SF LOT COVERAGE = 1,813 SF (30.5%) FLAT WORK IS SHOWN FOR ILLUSTRATIVE PATIO: 9 SF (INCLUDES EAVES) PURPOSES ONLY. FINAL CONDITIONS MAY VARY. Job Number ° 10 20 40 LENNAR NORTHWEST LLC. 21885 Scale 1"=20' Barghausen OLYMPIC RIDGE Sheer Drown Obriggs Consulting Engineers,Inc. HOMESITE 84 18215 72nd Avenue South Kent,w 98032 PARCEL NO. 12328-51-00084 of Date 6/5/23 425.251.6222 barghausen com 181 NE OLYMPIC RIDGE, BELFAIR, WA FIe:P:\21000s\21885\lot\21885—Olympic Ridge—Plot Plans.dwg Plot Date/Time:6/5/2023 3:46 PM DBRIGGS Name Sam Martin,Agent for Lennar Parcel# 12328-51-00084 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page I of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area " All dimensions in feet Buildings X = X = Measurements for buildings are taken at the X _ perimeter of the farthest projections(example: eaves/gutters) X = —Driveways X = X = Length of drive begins at the right of way X = Parking Areas X X = Any paved, gravel or packed area per definition above table X = Patios/Walks X X = Any paved, gravel or packed area per definition above table X = Others X X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) If the Total Impervious Surface Area is LESS THAN 2000 Square Feet,please read,acknowledge and sign below. Based Upon the information you have provided a Stormwater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X_ 7�u� Owner/Agent/Contractor(circle one)Date: 8/17/2023 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet,please read, acknowledge and sign the information provided on page 2 of 2. Page 1 of 2 Name Sam Martin,Agent for Lennar Parcel# 12328-51-00084 BLD# QM-O o2 Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction.A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14,Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70).You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan".This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details*are to be installed in their entirety AND no part of the Stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) X An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples.(Section 14.48.130)contact Public works at: Phone:(360)-427-9670 EXT.450 100 W PUBLIC WORKS DR SHELTON,WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel.You may also wish to consult with the septic design professional involved with the project.Mason County Division of Environmental Health can be reached at: Phone:(360)-427-9670 EXT.352 615 W ALDER ST SHELTON,WA 98584 A condition will be added to the building permit that states, in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X Sam Martin,Agent for Lennar Owner/Agent/Contractor(circle one)Date: 8/17/2023 Page 2 of 2 • MASON COUNTY COMMUNITY SERVICES Permit No: PERMIT ASSISTANCE CENTER: E- I„* .BUILDING-PLANNING-PUBLIC HEALTH-FIRE MARSHAL p-t t =- Y w 615 W.Alder Street,Shelton,WA 98584 1 1 •rs.,i �. Phone Shelton:(360)427-9670 ext.352-Fax:(360)427-7798 Phone APR Beltair(360)275-4467-Phone Elma:(360)482-5269 }3i)'R 1 7 202 00 BUILDING PERMIT APPLICATION 615 W. Alder Street C PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: r NAME: Lennar Northwest,Inc NAME: Lennar Northwest,Inc MAILING ADDRESS: 33455 6th ave S Unit 1-B MAILING ADDRESS: 33455 6th ave S,Unit 1-B CTfy: Federal Way STATE: WA ZIP: 98003 CITY:Federal Way STATE:WA ZIP: 98003 PHONE#1: (253)294-1322 PHONE:(253)294-1322 CELL: (253)294-1322 PHONE#2: EMAIL: Sam.MartinALennar.com EMAIL:Sam.Martinp.Lennar.com L&I REG#LENNANL783JO EXP. 03/18/24 PRIMARY CONTACT: OWNER❑ CONTRACTOR❑ OTHER R NAME Sam Martin,Agent for Lennar EMAIL Sam.Martin@Lennar.com MAILING ADDRESS 33455 6th ave S,Unit 1-B CITY Federal Way STATE WA ZIP 98003 PHONE (253)294-1322 CELL (253)294-1322 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number) 12328-51-00084 ZONING LEGAL DESCRIPTION(Abbreviated) Olympic Ridge FIRE DISTRICT SITE ADDRESS 181 NE Olympic Ridge CITY Belfair DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NOR SNOW LOAD:25_00psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that appl)): r, SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW R ADDITION❑ ALTERATION❑ REPAIR❑ OTHER USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc.)New SFR using approved stock plan#bid-xxx Plan 1217 A GR IS USE: PRIMARY% SEASONAL❑ NUMBER OF BEDROOMS 3 NUMBER OF BATHROOMS 2 HEATED STRUCTURE? YES(H%oleBldg)❑ YES(Parr[s)ofBldg)R NO❑ DESCRIBE WORK New Single Family Residence heated and garage unheated SQUARE FOOTAGE: (propose4 (� 1 ST FLOOR 1185 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK_sq.ft. STORAGE sq.ft. OTHER sq.ft. OGARAGE 400 sq.ft. Attached R Detached❑ CARPORT sq.ft Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIItONMENTAL HEALTH: SEWAGFJSEWER SOURCE: SEPTIC❑ SEWER® / NEW® EMSTING❑ PLUMBING IN STRUCTURE? YES R NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION D S PROPOSED? YES® NO[] EXISTING SQ.FT. 1645 EXISTING BEDROOMS PROPOSED BEDROOMS_ 3 — TOTAL BEDROOMS -7� — OWNER acknowledges that submission of inaccurate information may result in a stop work order or pemut revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) x c'5'G.Y)L� 8/17/2023 Signature of OWNER(Must be signed by the OWNER) Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH MASON COUNTY COMMUNITY SERVICES Permit No: L -C(500 PERMIT ASSISTANCE CENTER: a BUILDING •PLANNING •FIRE MARSHAL 615 W.Alder St-Shelton, WA 98584 RECEIVED www.co.mason.wa.us Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 APR 17 2024 Phone Belfair. (360)275-4467• Phone Elma.(360)482-5269 PLUMBING & MECHANICAL PERMIT APPLICATION 615 W. AJd°r Street OWNER INFORMATION: CONTRACTOR INFORMATION: NAME: Lennar Northwest,INC. NAME: Lennar Northwest,INC MAILING ADDRESS: 33455 6th Ave S,Unit 1-B MAILING ADDRESS: 33455 6th Ave S,Unit 1-B CITY:Federal way STATE: WA ZIP: 98003 CITY: Federal way STATE: WA ZIP: 98003 I'PHONE: (253)294-1322 PHONE: (253)294-1322 CELL: (253)294-1322 2nd PHONE: EMAIL : Sam.Martin(&Lennancom EMAIL: Sam.Martin@Lennar.com L&I REG# LENNANL783JO EXP. 03 /18 /24— PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number): 12328-51-00084 Zoning: LEGAL DESCRIPTION(Abbreviated): Olympic Ridge SITE ADDRESS: 181 NE Olympic Ridge CITY: Belfair DIRECTIONS TO SITE ADDRESS: TYPE OF JOB: NEW X ADD ALT REPAIR OTHER USE OF BUILDING New Single Family LOCATION OF FIXTURES/UNITS—1sT FLOOR X 2NDFLOOR X BASEMENT GARAGE OTHER PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Tyne of Fixture No.of Fixtures Fees Fuel Type:Electric LPG Natural Gas Ductless_ Toilets 2 Tyne of Unit No.of Units Fees Bathroom Sink 2 Furnace Bath Tubs 2 Heat Pump Showers Spot Vent Fan 3 Water Heater 1 Propane Tank Clothes Washer 1 Gas Outlets Kitchen Sinks 1 Wood/Gas/Pellet Stove 1 Fireplace/stove Dishwasher 1 Kitchen Exhaust Hood 1 Hose bibs 1 Dryer Vent 1 Other Solar Panel Other Ductless heat pump 1 Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. x �5'�W� 8/17/2023 Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT J-rL— PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN