HomeMy WebLinkAboutFIR2002-00033 Hood Duct - FIR Permit / Conditions - 1/16/2003 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352
Ir Shelton, WA 98584
flo
FIRE PROTECTION PERMIT FIR2002-06033
APPLICANT: PEDRO LOPEZ RECEIVED: 9/18/2002
CONTRACTOR: BE ANTHONY CONST MANAGMENT LICENSE: EXP: ISSUED: 1/16/2003
SITE ADDRESS: 23969 NE STATE ROUTE 3 SUITE C BELFAIR EXPIRES: 7/16/2003
PARCEL NUMBER: 123294190021
LEGAL DESCRIPTION: TR 2-A OF NE SE TR A OF SP#423#351008 PCL 1 OF BLA#98-58#671493
PROJECT DESCRIPTION: HOOD AND DUCT
GENERAL INFORMATION System Information
Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations:
Fire District: 2 Flow Switches: Visual Devices: Door Releases:
Hood & Duct?: Y Pressure Switches:: Smoke Detectors: Duct Detectors:
Dry Chemical?:
Zones: Heat Detectors:
Wet Chemical?:
Sprinkler?:
Standpipe?: SQUARE FOOTAGE FEES
Monitoring Station No.: First Floor: Type Amount Due Amount Paid
Auto Fire Alarm?: Second Floor:
Third Floor;: Hood & Duct $100.00 $100.00
Hood and Duct Plan $65.00 $65.00
Total: $165.00 $165.00
FIR2002-00033 Please refer to the following pages for conditions of this permit. 1 of 2
CASE NOTES
FIR2002-00033
CONDITIONS FOR
FIR2002-00033
This project becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended fora period of 180 days at any time after work is
commenced. Evidence o continuation of work is a progress inspection within the 180 day period.
Owner or Agent: _ 1 Date: (/
FIR2002-00033 Please refer to the following pages for conditions of this permit. 2 of 2
' MASON COUNTY FIRE MARSHAL RECEIVED
Mason County Bldg.111 426 W.Cedar P.O.Box 186 Shelton,Washington 98584 'JAN 1 100
(360)427-9670
426 W: CEDAR STe
CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION
PERMIT NO. ��(�
MASON COUNTY FIRE PROTECTION SYSTEM
PERMIT APPLICATION
PLEASE NOTE:This application must be completed and accompanied by a minimum of three (3) copies of
plans,specifications, and applicable calculations per Mason County Fire Protection Standards, and
submitted to the office of the Mason County Fire Marshal. This is not a permit and failure to submit all
necessary information will cause a delay and/or rejection of your submittal. When a permit has been
issued,you will be notified.
PLEASE PRINT
OWNER: odro /�pUco-,- PHONE: FIRE DISTRICT a
SITE ADDRESS: % / CITY - STATE' ZIP
MAILING ADDRESS`<2Zt212, CITY STATE ZIP
LIEN/TITLE HOLDER:
ADDRESS: CITY STATE ZIP
CONTRACTOR Z< <�
ADDRESS:— . X S CITY f1 u,r STATEkAIP
CONTRACTOR PHONE#A 3G� d 2 -r CONTRACTOR REG# 16
PARCEL* J l l ctX-;21 LEGAL DESCRIPTION:7k Q-h OF A)E -SF 7Q A OF
(�F #ya3 -* 351oo8 prA 1 oF, gLA
BLDG. SQ. FT. (EXISTING/PROPOSED)lST FL / 2 / 3RD /
USE OF BUILDING PP �,4 0("V-P
DESCRIPTION OF WORK: SPRINKLER: WET DRY STANDPIPE: WET DRY
AUTOMATIC FIRE ALARM HOOD & DUCT:X_DRY CHEMICAL
WET CHEMICAL N,HALON NEW SYSTEM—)(-_ MODIFICATION
MONITORING STN PHONE
4
YOUR SUBMITTAL MUST INCLUDE:
1. DIMENSIONS, SCALE, NORTH ARROW
2. FLOOR PLAN AND CROSS SECTIONAL ELEVATION
3. ALL CONCEALED SPACES (LABELED COMBUSTIBLE AND NON-COMBUSTIBLE)
4. CUT SHEETS OR REFERENCES FOR ALL NEW DEVICES -
5. LOCATION/DESCRIPTION OF ANY EXISTING DEVICES
6. BATTERY CALCULATIONS FOR FIRE ALARM SYSTEMS
7. RISER/WIRING DIAGRAM FOR FIRE ALARM SYSTEMS
8. HYDRAULIC CALCULATIONS FOR SPRINKLER SYSTEMS
PLEASE NOTE: WORK MAY PROCEED ONLY IN ACCORDANCE WITH A VALID FIRE PROTECTION
SYSTEM PERMIT ISSUED BY THE MASON COUNTY FIRE MARSHAL. A VALID PERMIT AND AN
APPROVED SET OF PLANS MUST BE ON THE JOB SITE DURING CONSTRUCTION AND MUST REMAIN
THERE UNTIL A FINAL INSPECTION IS DONE BY THE MASON COUNTY FIRE MARSHAL. FAILURE TO
OBTAIN A VALID PERMIT PRIOR TO WORKING ON A FIRE PROTECTION SYSTEM AND/OR FAILURE TO
PROVIDE THESE PLANS AND PERMIT FOR THE MASON COUNTY FIRE MARSHAL MAY RESULT IN A
CITATION AND FINE.
OWNER'S AFFIDAVIT
I certify that I am exempt from the requirements of the Contractor's Registration Law RCW 18.27, and am
aware of the Mason County ordinance requirements for which this permit is issued and that all work will be done
in conformance therewith. No changes will be made without first obtaining approval from the Mason County
Fire Marshal.
OWNER: DATE:
CONTRACTOR'S AFFIDAVIT
I certify that I am a currently registered contractor in the State of Washington and I am aware of the ordinance
requirements regulating the work for which the permit is issued and all work done will be in conformance
therewith. No changes will be made without first obtaining approval from the Mason County Fire Marshal.
DATE:
BY: _ i—