Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2019-00176 Completion of SFR for Cancelled BLD2001-01039 - BLD Inspections - 6/9/2022
1 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us B DD2019-00176 ADDITION OR REMODEL- RESIDENTIAL PROJECT DESCRIPTION: COMPLETION OF SFR SEE ORIGINAL ISSUED: 04/24/2019 TIDEMARK CASE FOR DETAILS (BLD2001-01039) 9/27: REVISION SUBMITTED -216 SQ FT OFFICE ADDITION EXPIRES: 10/21/2019 SITE ADDRESS: 410 E PROBERT RD SHELTON PARCEL: 221287690091 APPLICANT: AYALA, NORA OWNER: NORA AYALA WILLIAM F MCGOWAN WILLIAM F MCGOWAN SHELTON, WA 98584 SHELTON, WA 98584 VALUATIONS: FEES: Paid Due Covered Deck/Carport 56.00 $1,232.00 Plumbing Base Fee $25.00 $0.00 R-3 VB Residential, one- 1964.00 $237,153.00 Plumbing Fees $95.00 $0.00 and two-family Mechanical Fees $143.00 $0.00 R-3 VB Residential, one- 2/6.00 $26,187.84 State Fee-Residential $6.50 $0.00 and two-family Plan Check Fee $1,367.18 $0.00 Building Permit Fee $2,103.36 $0.00 Mechanical Base Fee $30.00 $0.00 Building Plan Review/Change of $110.00 $0.00 Use- Onsite Sewage Building Plan Review Revisions $80,00 $0.00 Total: $264,572.84 Totals : $3,960.04 $0.00 FIXTURES Qty Mechanical Fixtures (Qty Plumbing Fixtures 1.0000 Dryer Vent(s) 1.0000 Number of Bath Tubs 1.0000 Kitchen Exhaust Hood(s) 1.0000 Number of Clothes Washers 1.0000 Ductless Heat Pump 1.0000 Number of Kitchen Sinks 1.0000 Solid Fuel Burning Equipment: Wood, Pellet, LP 1.0000 Number of Showers and fireplace, barbeque appliances 1.0000 Number of Water Heaters and or Vent 2.0000 Spot Vent Fan(s) Printed by Ariane Paysse on:10/24/2019 03.24 PM Page 1 0(6 Mason County ( Mason County - Division of Community Development �yy 615 W. Alder St. Bldg. 8 Shelton, WA 98584 \ 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00176 CQt Plumbing Fixtures 2.0000 Number of Hose Bibs 2.0000 Bathroom Sink 2.0000 Number of Toilets REQUIRED INSPECTIONS Shearwall Inspection Mechanical Inspection Framing Inspection Insulation Inspection Rough- Plumbing Inspection BLD-Final Inspection CONDITIONS * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * WIND LOADS- Roof coverings shall be designed and tested to withstand the maximum basic wind speed. The basic wind speed for Mason County is 85 MPH. * Concrete encased grounding electrodes must be installed and used at each new building or structure that is built upon a permanent concrete foundation. In Mason County the electrical code is regulated by Washington State Department of Labor & Industries (L&I). For more information contact L&I for additional information. In Olympia call (360)902-6350 and in Bremerton call (360)415- 4000. * The plan review check list and corrections are part of the approved plans and must remain attached. It is the responsibility of the applicant, owner or contractor to make the required corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be cha,iged or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. Printed by:Ariane Paysse on:10/24/2019 0124 PM Page 2 of 6 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-0017 6 ' Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window (Max U- Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. 1a - EFFICIENT BUILDING ENVELOPE 1a: Prescriptive compliance is based on Table R402.1,1 with the following modifications: Vertical fenestration U = 0.28 Floor R-38 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total UA by 5%. 3d - HIGH EFFICIENCY HVAC EQUIPMENT 3d: Ductless Split System Heat Pumps, Zonal Control: In homes where the primary space heating system is zonal electric heating, a ductless heat pump system shall be installed and provide heating to the largest zone of the housing unit. 5a - EFFICIENT WATER HEATING 5a: All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. 5c- EFFICIENT WATER HEATING 5c: Water heating system shall include one of the following: Gas, propane or oil water heater with a minimum EF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation (SRCC)Annual Performance of OG-300 Certified Solar Water Heating Systems or Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards of NEEA's Northern Climate Specifications for Heat Pump Water Heaters ` A Road Access Permit or Approval must be granted by the Mason County Department of Public Works. For more information contact Public Works, at (360) 427-9670, ext. 450 or 100 W Public Works Dr. Shelton. The building permit will not be finaled until the permit holder can show proof that the access permit from Public Works has been finaled and approved. The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Ariane Paysse on:10/24/2019 03:24 PM Page 3 of 6 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 Shelton, WA 98584 \ 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00176 * Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181 B-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches (38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall ':)e conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * All surface water and potential runoff must be controlled on site and shall not adversely affect any adjacent properties nor increase the velocity flow entering or abutting to any state or county culverting/ditching system or road way. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * All property lines shall be clearly identified at the time of foundation inspection. * By definition, propane tanks and heatpumps are structures,which must meet setback conditions. Please check your "Approved Site Plan"to ensure these structures meet the setback conditions listed. * REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * A minimum of 75 percent of all permanently installed lamps in lighting fixtures shall be high efficacy lamps in accordance with IECC/WSEC Section R404.1. Printed by Ariane Paysse on:10/24/2019 03.24 PM Page 4 0(6 Mason County Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 v Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00176 ' Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned worth:which may affect your project. " Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. " All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. " Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. ' A permanent certificate, completed by the builder or registered design professional, shall be posted on a wall in the space where the furnace is located, a utility room, or an approved location inside the building. When located on the elctrical panel, the certificate shall not cover or obstruct the visibility of the circuit directory label, service disconnect labek, or toher reqyired Iabels.The certificate shall list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundation (slab, fenestration;basement wall, crawlspace wall and/or floor), and ducts outside the conditioned spaces; U factors for and the solar heat gain coefficient(SHGC) of fenestration. Where there is more than one value for each component, the certificate shall list the value covering the largest area. The certificate shall list the type and efficiency of heating, cooling, and service water heating equipment, duct leakage rates including test conditions as specified in WSEC Section R401.3 & R402.4.1.2, and air leakage results if a blower door test was conducted. Building envelope air leakage control shall be considered acceptable when tested to have an air leakage less than 5 air changes per hour when tested with a blower door in accordanve with IECC/.WSEC Section R402.4.1.2. The blower door test results shall be recorded on the permanent certificate required located near the electrical distribution panel. Air leakage testing is not required for additions less than 500 square feet. Reference IECC/WSEC R402.4.1.2. Compliance certificates are available online at the WSU Energy program website titled, "WSEC 2015 Certificate" and are available in '/4 or'/z sheets. The Mason County Permit Center will also have some available. " The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where such roads connect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road. Printed by:Ariane Paysse on:10/24/2019 03:24 PM Page 5 of 6 Mason County ' Mason County - Division of Community Development 615 W. Alder St. Bldg. 8 `}h° •"IV F`\Y Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ADDITION OR REMODEL- RESIDENTIAL BLD2019-00176 " All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. ' A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public:Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. "NOTE if Stormwater Management option "A"was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan"constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/a gent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. ' The foundation/footing must be placed on undisturbed, firm-native soil. ' All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. ' Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. . On-site Septic System inspection required prior to temporary/final occupancy of the residence. • A letter/report is required from they engineer prior to scheduling a framing inspection with the Mason County Building Department. This letter or report must be stamped, signed, and dated by the engineer. Item that shall be addressed within the report are as follows; Structural Members (Columns, Beams, Connections, Strapping and Cables) and Cord-wood wall construction (motar used, connections, and compliance was achieved). Letter/Report must be submitted to the building department for review prior to framing inspection. If you have any questions, please conta t the Mason County building Department (360)427-9670 x352. X 1�._C � " The following inspection have been completed under permit# BLD2001-01039; Footings/setbacks—2-18-03 CMU foundation—9-12-05 Under floor plumbing—8-20-02 Slab Insulation—5-1-03 1 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized A ent: Date: Printed by:Ariane Paysse on:10/24/2019 03:24 PM Page 6 of 6 CONCRETE � h'EGHANICAL N{,4MURACTURED HONE its g-2 u-z l By J7Z_ oo.ings 1$e;txac Gas Piping Ribbons 1,Tte io:'Date By in=wrior-Date By ^a a ay Exierior Dat-- 3y Em-ior-Rafs E;Y Sc -ss�rr Point Laad t lscd=ad Footings INSULATION Esc Date- �y Boo 1 SAS lhZuLF.i l0h1 J - e-r- /f_ ,(cI By FIRE DEPARTMENT Foundaiian 1h'alis j Roam DaL- RY Dad` By `a� ey 1 DECKS FRAMING � Walls � Rates. By, Rate- /1-W-(g By D6cI`n--- 5- I I"R©PACE TANK S PLUMBING Vault � Dats By Data BY ETHER Gratn=8wa�k Atfic -type-- By a By ]a;e I DRYWAL1 Sy tv'.11ti'.'V 'Fy,tee: Day Int Brace WallDat Bq C4 By v 2y F1NAL INSPEC TION (� m Wzler Line Fire Seperation Ca e By I Date Zy o T{ _ Fuss or Request Ins ct. pe Ins . Fail Date Date CDI acne Ey Cram errs �R T� r,a �',�( r��--� •!4 I rtK✓me s0 t l ! � \ -A ZAl AI -Av- COW Car�-eGb*S MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfairext.352 360-482-5269 Elma ext.352 Building, Planning, Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIOWINSPECTION REPORT PERMIT/CASE NUMBER: L /9—06V 7�0' 1 ADDRESS/LOCATION: y/G Pro 4-e—F� -tJ - —IA�— FINDINGS: 14 Items listed above must be corrected to 1jain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. , Make corrections, items will be checked on the next inspection. ❑ OK to Date: 11, 6119 ❑ Please contact our office regarding possible Department:_��_ structural damage incurred by recent Inspector: "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 y MASON COUNTY 360427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building,Planning,Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIOWINSPECTION REPORT PERMIT/CASE NUMBER.: Lb 2'01 q —t01 CP / ADDRESS/LOCATION:_ y`D 67 /p'r S l 014 FINDINGS: ( kA/'C e C OV14 014 S dr All ff 2� D ar u ego zuwp4G Items listed above must be corrected to zain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. J*Make corrections, items will be checked on the next inspection. ❑ OK to Date: C2'2 `Zd ❑ Please contact our office regarding possible Department: L structural damage incurred by recent Inspector: ' ,�/j.G - "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 COMMUNITY SERVICES 36 60-482-52 Belfair ext.352 360-482-5269 Elma ext. 352 Building,Planning, Environmental Health,Community Health 615 W. Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: , [. . 2or9 _ D t1-1to / ADDRESS/LOCATION: �l1O 12 `a'L.t I4-01 ti FI ING 6411 ✓a /vt l<v/ ✓ew, . Co /.c k- Ns41q ll� 0,11 ca 4t14.4-r -n ct 1 I t C*ha I� a ti►,.� rc4 a e- 1 A u c �. Lwd K ke 14v o4 ?YaY�S c y � S-M i k ke✓t201 u+ra rc 't- ug .�OCS aH vUu�dC.i. L we r r�(P7) �f � s4,Sic 1 y vdcl� NrPCr o f�e'EvY 1'Ov 4.11 01 t -�•� rt � � � t tg� Items listed ab ve must be corrected to zain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. -Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make rrections--items will be checked on the next inspection. K 0- Date /0'let ❑ Please contact our office regarding possible Dep meet: structural damage incurred by recent Inspe tor: "natural/man made"disasters.This is NOT a -- CORRECTION NOTICE. O NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 36 Be ext.352 COMMUNITY SERVICES 360-482-5269 Elma 90) ext.352 Building,Planning, Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTIONANSPECTION REPORT PERMIT/CASE NUMBER: jad Zn\C:1 —coo\`� Ce ADDRESS/LOCATION: L E 2 robe-v' - r-CA . FINDINGS: _ e,r Aon v A v SS 0Y , bcD1NX-z- - �J ESQ +(-O IM ro�� OV�t_ CA.1n . rye rc� �0as U er �S � Selr\J� :oh.S row �ana� h ee�- Y�0yIe rl . X, -6SCkyyA t C r vvve -e- �e ��. �Y\ .M . Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. all for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: C - �. - ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector: �/ "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 MASON COUNTY 360-427-9670 Shelton ext.352 360-275-4467 Belfair ext.352 90), COMMUNITY SERVICES 360-482-5269 Elma ext.352 Building,Planning, Environmental Health,Community Health 615 W.Alder St. Bldg.8 - Shelton,WA 98584 www.co.mason.wa.us CORRECTION/INSPECTION REPORT PERMIT/CASE NUMBER: -LVZot F—Cif 76 ADDRESS/LOCATION: Pro 4.Cr_r R� Sr M91-1, FINDINGS: _ e&Z,W y dJd � liSiZI,CI� t ¢ �9/ Oar J-a CJ- S' )2 e?v w 'k& s - p/odJ �J�er" roa.�, f�.e, GLc9 •f Gw� o �ecaf Cort-eGr�foKs dkc GJ Gt Le el- is- eeef Items listed above must be corrected to gain compliance. ❑ THIS IS NOT A COMPLETE INSPECTION ❑ This structure has been inspected by Mason County Building Department and the items listed above are in VIOLATION of Mason County laws and/or ordinances. ❑ Call for re-inspection when corrections are made before proceeding with any further work. ❑ Make corrections, items will be checked on the next inspection. ❑ OK to Date: &' Z�7 _ ❑ Please contact our office regarding possible Department: structural damage incurred by recent Inspector:_ / �— — "natural/man made"disasters.This is NOT a CORRECTION NOTICE. DO NOT REMOVE THIS TAG MCC14.12 =� N.L. Olson & Associates . �c February IL 2021 Nora Ayala RECEIVED d 10 E Probert Road Shelton, WA 98584 APR 19 2021 RE: Framing Inspection of Structure at 410 E Probert 615 W. Alder Street ,Ms. Ayala, NIL Olson and Associates was retained by you and your husband to prepare plans for a new single-family residence at 410 Probert Road.Construction had started on a house then stopped and the framing was left exposed to the elements. A building permit was subsequently issued and 1 understand that the county has requested that I perform another inspection of the framing prior to continuing with your permit.This letter is a summary of my follow-up inspection on January 26, 2021. At the time of my inspection. the house was"dried in"and siding was installed. A minor change to the upper floor framing was included in the permit package and that framing was complete.All the framing I witnessed was acceptable. The steel rod bracing at the North wall (adjacent to the turret area)was missing a nut on the end of the diagonal rod.At this point in time,there is likety no way to install nut and washer. I also noticed that:the stair landing on the first floor was less than 36"wide with the diagonal cable bracing. The original plans in 2001 assumed the exterior walls were going to be constructed using cord wood.The diagonal rods and cables were to provide the shear resistance missing for the cord wood wall system. Your contractor has framed the exterior walls using 2x6 studs and plywood sheathing. As a result of my review of the bracing I have the following recommendations. 1. I checked the north exterior wall without the diagonal rods and only using the shear wall sheathing on the stud walls. I recommend that the north exterior wall on the first floor be sheathed on the inside with !!"plywood and nailed with 8d nails spaced 6"on center at the panel edges. 2. 1 also checked the shear capacity of the exterior wall at the stair landing at the main floor. I recommend that the cable bracing be removed and the inside wall be sheathed with ', plywood and nailed with 8d nails at 6"on center at panel edges. Both wall recommendations above will use the existing timber columns as chords.The stud adjacent to the timber column will have the interior shear wall edge nailing pattern.Therefore, that adjacent stud should be fastened to the post w ith 16d nails spaced 3"on center. I am attaching with this letter a sketch of the first floor showing the locations of the recom it abo%c and a shear wall calculation for each wall. Please let me know if there are questio 0� 14ASk Off Respectfully submitted, iypC f_ y try-�'slG 46 Matthew Zawlocki, PE. SESclO C PO Box 637 - 2453 Bethel Avenue Port Orchard, WA 98366 (360)876-7284 t 'Vvxvxxv.nIOISOT].com RFC -� N.L.Olson&Associates,Inc. 6, � 4 ? Engineering, Planning and Land Surveying. �!q1C, trel.t February 19, 2019 Ao QE ktp Nora Ayala 4 T 410 E Probert Road '�RC,� N rhF Shelton, WA 98584 RE: Inspection of Structure at 410 E Probert 0/ Ms. Ayala, NL Olson and Associates was retained by you and your husband to prepare plans for a new single-family residence at 410 Probert Road. Construction had started on a house then stopped and the framing was left exposed to the elements. Our scope of work included a site inspection of the building and preparation of a set of plans to reactivate the prior building permit. The house is not a typical stick-framed house. My initial building inspection was on May 23, 2018. At the time of my inspection, the columns, "X" bracing and roofing was installed. All of the existing materials were in good condition. As a result of the site visit and subsequent structural analysis, I prepared a set of building plans at the end of July 2018. As a result of a recent meeting with the building department, I have made additional clarifications/additions to the structural plans and attached them with this letter. Please let me know if there are questions. Respectfully submitted, Matthew Zawlocki, PE, SE ���c.OF wA 4 T � 409 �SS�ONAL ECG 2453 BETHEL AVENUE, P.O. BOX 637, PORT ORCHARD, WASHINGTON 98366 (360) 876-2284 FAX (360) 876-1487 G ntil WINDOW ERS J1bg o BA EIpAT@ 4x6 POST USESUPP�T FLAT D2x16BV, tll 4x6POSTC6--�1' CMST12 G mx 2040 I I & ST12 to 20A0 �090 2030 rC6�2X c> DOUBLE 2x6 A 6%12 W o TOP PLATE o �p W/2x6 @ 16' CMST14 O.C. STUD WALL CMST12 ua BELOW °' 6 CS14 FRIDGE CTYP) N z Rm 6x6 POST x BH 5.5/11.25 PANTRY BATH O w LIVING ROOM © C4 x6 POS7 N DUCTLESS MINI W/HUC68X, MAX UC612 MAX ON o SPLIT HVAC 6x6 POST 4x6 W/HUC612X W/HSPF>9.0 MST14 � Eke 6%�2 640 - a Apyp D S16 Z U 0 U ,o 0 2x6 @ 16 OC x xx x6 POST x m S76 � - to V' a W/HUC612X co a C� '° 00 x m W o0 to 2x6 STUD m QOi xo j WALL DECK d m 6klp x� N S16 mi c3 MBHA3.56/9.2 -HANDRAIL t x � 4x6 W/HUC612X x 2x8 @ m� ,0 nu f-lU W L7 3 16 OC N`° 4x C3 O % OPEN TO v mr CSI 303 .q 4x10 m 6x$ BELOW W xx 4x4 W/HUC410X CMST1 0 .o p}fp CS16 MST14 t` MST14 C3 DN HCSTR 6x6 PATIO OR - 2x8 @ 16 OC C3 CMST12 C4 UP x6 POST in� o %J K CMST14 C m ...�s��_. .. .. _"_._ .. ..". _... .d 00 CS16 40760 40760 40760 40760 x6 POST � N 4x6 d o PC44 ON 4x4 � � � POSTSSTRAP BEAMS TOGETHER WITH HORIZONTAL d .� HCSTR2 OR CMST12 ACROSS POSTS 41 FIRST FLOOR FLOOR PLAN FIRST FLOOR FRAMING PLAN :�TCl va' %' CABLE BRACE = 1-o• NOTES, 1/4' = V-0' � C3, CABLE BRACE �' CABLE BRACE • C41 CABLE BRACE • C51 7�' CABLE BRACE • C6� 1' CABLE BRACE • ALL CABLE BRACES MAY BE 1'O STEEL RODS Xa4 INSTEA➢ OF CABLE SIZES LISTED ABOVE. • ALL STRAPS ARE INSTALLED HORIZONTAL ACROSS POSTS. INTERIOR OR EXTERIOR OR BOTH SIDES. QT = TEMPERED GLASS WINDOW 0 = 80 CFM FAN W/TIMER TO RUN 15 MIN/HR 4 to yr a` C ° d APR 15 2019NWA 0 $ g zW /�+\ MASON COUNTY ENVIRONMENTAL HEALTH l �✓ 2-0 1 (��--'1 — � © ^�7 W LJ � SCALE: AS SHOWN 1 ` DATE: July 2018 DRAWMWUMBER 10327-18 SHEET S2 A F. 10' HIGH BLOCK WALL 2040 - p 'L p0 3020 p� 2'-9' � 16, 9'-4' HIGH 2'x6' STUD DRYER WASHER / WALL W/6' FIBERGLASS TUB WER o / ROLL INSULATION w BETWEEN STUDS @ 16' O.C. BATHROOM J S R6'-9' O.C, I I o aO. w 3'-3' FOOTING 4 \\ I I I w MIN EF = 0.91 0 W/#6 @ 12' D.C. E.W. 9'-4'BLOCK \ I -I �'Oq� - MI z WALL \ ( I = \ \ �6•� I 8' BLOCK ROWS WALL I I HDSA 2BTWNCHIMNEYC& H/W COMBUSTABLEllr8 E12 - MATERIALS WOOD Mi p; (CONSTRUCTED ED AS IN I I 00 2' FOOTING I FDN PLAN)2" FOOTING I I I DSA STOVE Mi C7 c Q 9'-4' BLOCK J I Jam. 1� O a WALL v o 0 CMS � � K 0 2'-T FORTING C3 J, I I 3%zo HD35 20 STEPS - 6'RISE, 10' DEEP, 3' WIDE J CONC SLAB I I Y m z BASEMENT TO IST FLOOR 3 x 0 co HD1 MASTER BEDROOM o / / I I v HD14 C4� OIL w i / 5' FOOTING I I =0 3 INFILL W/4' CONC ON w o 3 2' RIGID INSULATION < - by 0000 _ I _ I I ,^,"' ANDING 42' d. 4'-3' FOOTING I I C4 OFF FLOOR 2' FOOTING AILING o Q L-- - -- - - - - - -- — — —— — - - --� I � a3 HD14A 46560 46560 46560 46560 W G 4'-8' HIGH BLOCK WAIL 9'-8' HIGH BLOCK WALL (EGRESS WINDOW) - Q (14 ROWS - B'x8'xl6' M1 16 ROWS - Wx8'x16') 1 ROW - 4'x8'xl6') FOUNDATION PLAN DAYLIGHT BASEMENT FLOOR PLAN = 1'-0' NOTES, 1/4 = 1'-0 NOTES 1/4' ' ' • C2, CABLE BRACE • C3, CABLE BRACE • C41 CABLE BRACE • Mll 8' CONCRETE BLOCK WALL W/#4 BARS @ 2' O.C. VERTICAL AND HORIZONTAL ' a • M2- 8' CONCRETE BLOCK WALL W/#7 BARS @ 8' ❑.C. VERTICAL AND #4 BARS @ 2' ❑.C. HORIZONTAL ALL CABLE BRACES MAY BE 1'0 STEEL RODS INSTEAD OF u CABLE SIZES LISTED ABOVE. m • USE SSTB28 ANCHORS FOR HD6A & HD8A °p " • FOR HD14A & HD15A USE 1'0 A36 ANCHOR BOLTS EMBEDDED w B A MINIMUM OF 12 INCHES WITH A �'4"x332'x332' WASHER ;? PLATE. o m a Q = 80 CFM FAN W/TIMER TO RUN 15 MIN/HR --e� obo QS = IlOV/BATTERY BACKUP SMOKE DETECTOR 4 w R7 a d QT = TEMPERED GLASS WINDOW 5 c m g ® = CARBON MONOXIDE DETECTOR a .° SCALE: AS SHOWN DATE: Imy 2018 DRAWING NUMBER 10327-18 SHEET Sl ` l '� I PSI-Olson&Associates,Inc. Project Title: ��T, PO Box 637 Engineer 2453 Bethel Ave Project ID: (� Port Orchard,WA 98366 Protect Descr: w , (360)876-2284 Csented 19 FE8 21727 .: Wood Shear Wall sa3aAa�au�uez< DESCIUMON: north main floor wall General Information Calculations psr NDS 2015,IBC 2015,CDC 2016,ASCE 7 10 Total Wall Length 18.0It Framing&Chord Material Number of Storys 1 Wood Species: Hem-Fir Story#1 Height 8 0 ft Wood Grade: No.2 Fc-Pdl= 1300 psi Ft-Tension 525 psi FC-Perp= 405 psi E 1300 ksi Specific Gravity= 14301 SDC:Seismic Design Category : D Sheathing Main Sheathing SDPWS 2015 Construction Table: 4.3A Wood Structural Panels,Sheathing,15f32'Thk,1-3+'8'Min Pen,8d Nominal Seismic ties(A' 6'Spac. 520 _,,.3`Spac. 'y980 4'Spac. --6-' 2'Spac. 1280 Nominal Wind Shear Capacities(plf) 6'Spac, 730 3'Spac. 1370 4'Spac, 1065 2'Spac. 1790 Chard Data Chord Member Size for each level: See Chord Summary Tables for number of Chords required at each panel end Level 1 Chord Size: 2x6 Chord Cf. Comp 1.0 Tens: 1.0 Max.Allow Stress Ratio: 10 :1 Chord Area= 8.250 in"2 All chords treated as fully braced about both axes Opening ID Dist to Opening Dist to Opening Left Edge Width Bottom Height ft ft ft i ft � ft t ft NL Olson&Associates,Inc Project Title: PO Box 637 Engineer. 2453 Bethel Ave Project ID: j Port Orchard,WA 98366 Project Descr: �► (360)876-2284 o,j,.,ea 11 FES 25� _ Wood Shear Wall son Iwc,�1�t ttz2asu DESCRIPTION: Stair landing exterior main Boor wall General Information Caku a bm per NDS M5,8C 2015,CBC 2016,ASCE 7.10 Total Wall Length 7.0ft Framing&Chord Material Number of Storys 1 Wood Species: Hem-Fir Story#1 Height 8 0 ft Wood Grade: No2 Fc-Pdl= 1,300.0 psi Ft-Tension 525.0 psi Fc-Perp= 405 0 psi E 1,300.0 ksi Specific Gravity= d.4301 SDC:Seismic Design Category : D ....--Sheathing Main Sheathing SDPWS 2015 Construction Table 4.3A Wood Structural Panels,Sheathing,15132'Thk,1-3/8'Min Pen,8d Nominal Seismic Shear Capacities(pff): 6'Spac. 520 3'Spac. 980 4'Spac. 760 2'Spac. 1280 Nominal Wind Shear Capacities(ptf) 6'Spac. 730 3'Spac. 1370 4'Spac 1065 2'Spac. 1790 Chord Data Chord Member Size for each level: See Chord Summary Tables for number of Chords required at each panel end. Level 1 Chord Size: 2x6 Chord Ct Comp: 1.0 Tens: 1.0 Max.Allow Stress Ratio: 10 1 Chord Area= 8250 in"2 AN chords treated as fully braced about both axes Dist to Opening Dist to Opening Opening ID Left Edge Width Bottom Height fi r, fi ft ft ft i it ) ft � ft { I � r-� N.L. Olson & Associates, INC. June 8,2022 Nora Ayala 410 E Probert Road Shelton, WA 98584 RE: Final Inspection at 410 E Probert Ms. Ayala, NL Olson and Associates was retained by you and your husband to prepare plans for a new single-family residence at 410 Probert Road. I have been to the house several times to inspect various elements of construction. I understand that at the last inspection,the county requested something from the engineer stating that the corrections to the shear wall as described in my Feb 2021 letter are acceptable. In my opinion,the revisions to the shear wall system noted in my Feb 2021 letter were appropriately implemented and are acceptable. Please let me know if there are further questions. Respectfully submitted, Matthew Zawlocki,PE, SE " °F WA.-V �o cTt40916���'� �F4 R A L 6 SS�06�t0 PO Box 637 • 2453 Bethel Avenue - Port Orchard, WA 98366 (360) 876-2284 www.nlolson.com