Loading...
HomeMy WebLinkAboutStormwater Facilities Review for COM2001-00044 - COM Engineering / Geo-Tech Reports - 6/28/2001 T MASON COUNTY PUBLIC WORKS DIRECTOR/COUNTY ROAD ENGINEER Shelton,Washington 98584 DATE: June 28, 2001 INTER-DEPARTMENTAL COMMUNICATIONS TO: Scott Longanecker, DCD- Planner FROM: Alan A. Tahja, P/W- Co. Hydr. Engr. DCD WO# 2001-0144 SUBJ: Stormwater Facilities Review NAME: Belfair Safeway Service Station COM2001-00044 Scott, I have been in contact with Jim Harrison of BUSH, ROED& HITCHINS, INC., discussed the stormwater requirements pertaining to the proposed development of the service station with Jerry Hauth, and feel the proposal is acceptable. The following email correspondence has brought a couple of items in the Technical Information Report into compliance with County requirements: From: Jim Harrison <JimH@brhinc .com> To: 'Alan Tahja' <Aat@co.mason.wa.us> Date: 6/28/01 3 :41PM Subject: RE: Safeway Fuel Addition Thank you for your prompt response . The items noted herein will be addressed and the O&M covenant will be executed as instructed. I will forward revised pages of the T. I .R. to you for replacement . Thanks again. Jim Harrison -----Original Message----- From: Alan Tahja [mailto:Aat@co.mason.wa.us] Sent : Thursday, June 28, 2001 3 : 19 PM To: JimHQbrhinc .com Cc: aat@co.mason.wa.us Subject : Re : Safeway Fuel Addition Thank you Jim. My check of 40 CFR 112 indicates that the threshold for File: H:\WP\STRMWTR\REVIEWS\Blfr-Safeway.doc PERMIT#'. (E) Work Order C-0,o 2-Co I 4tY Requested lNumber. Authorized by. Date: Type of Work. r CHARGE TO: I/10e ,c ZZ- NME AGENCY/COMPANY ------------- 131LUNG ADDRESS PHONE Y- (a) Pub. Works Person In Charge: 4 (0) Proled Time Une: m -to dates H e— TO Projoct Start dew EvWueed Fir-gsh Date: Apffminate hxn: ESTIMATED TOTAL is: COST ESTIMATE - -------- (D) Hour ;3I Fffna*% TOTAL lep 3� —7 C-' 7; vwI B OTAL U EQUIPMENT USED: MATERIAL us ED. (F) Actual Cost s Euu:ts: PROJ DATE Eye Narne Hours §MQtAFl y TOTAL$ EWPMENT USED: JOT�L S'$ MATERIAL USED: TOTAL ALL (1G) BILLED DATE INV 9— PAID DATE REC-0— CKS requiring a Spill Control & Countermeasure plan is 42,000 gallons or greater of underground storage. . . the threshold is much lower for above ground storage. I've discussed the dead end sump versus oil water separator with the County Engineer, and checked how Ecology's Manual addresses the issue, and have come to the conclusion this proposal meets the minimum requirements. I also took a closer look at the plans to satisfy myself that the collection area for the fueling area wasn't connected to the stormwater sewer system that receives most of the site's runoff, and see where they cross, but are kept separate. The technical Information Report accompanying the plans contains 3 Core Requirements which will need to be addressed differently than promoted. These are Core Requirements 6 through 8. Mason County employs an Operation and Maintenance (O&M) Covenant to ensure that the designed and constructed stormwater control and treatment facilities are operated and maintained as designed. Attached please find a copy of the Covenant Form the County employs. The Covenant should be appropriately filled out, signed and notarized by the responsible individual, recorded with the Mason County Auditor's Office, and a copy of the recorded covenant delivered to Public Works for monitoring and administration. The O&M Covenant was developed partly to address the issue of Financial Guarantees and construction completion bonding. Belfair is an unincorporated town in the County, and has no municipal power to require or administer the bonding alluded to in your core requirement V. Core Requirement #8 alludes to a coalescing plate oil/water separator, which File: H:\WP\STRMWTR\REVIEWS\Blfr-Safeway.doc you intend to replace with the dead end sump. Because there appears to be no vehicle maintenance proposed at the fueling facility, a coalescing plate separator requirement by the County appears arguable, so is not being required at this time. Again, thank you for your help. Please feel free to call or email me if you have any questions regarding these comments, or if you have questions pertaining to the 0&M Covenant form. >>> Jim Harrison <JimH@brhinc.com> 06/28/01 10:33AM >>> Mr. Tahja The underground fuel storage consists of one-20,000 gallon and two-10,000 gallon capacity tanks for a total underground storage volume of 40,000 gallons. Please let me know if any additional information is required. James V. Harrison Project Manager Bush, Roed & Hitchings, Inc. (206) 323-4 144 (206) 323-7135 FAX Jim has called me and is rewriting their Core Requirements 6 thru 8 to bring them into compliance with the County requirements. Jim also indicated that the O&M Covenant would be completed and delivered to Public Works. Please feel free to contact me at County extension 461 if you have any questions regarding these comments,r if you feel anything else needs further attention. Si rely, Alan A.Tahja File: H:\WP\STRMWTR\REVIEWS\Blfr-Safeway.doc