Loading...
HomeMy WebLinkAboutCOM2014-00003 Special Inspection - COM Inspections - 10/20/2014 D MASON COUNTY f DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg, 111,426 West Cedar Street :- PO Box 279, Shelton,WA 98584 M 4 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4467 Elma(360)482-5269 SPECIAL INSPECTION (SI) & STRUCTURAL OBSERVATION (SO)REQUIRMENTS 2012 International Building Code Permit# Project Name Project Address Mason County Tax Parcel Number Have the responsible Registered Design Professional(RDP)identify all the items which apply to this project&indicate which agency(by NUMBER 1-6, see below-no h's)is responsible for each SI or SO.See the 2012 IBC for further info. IBC RDP SIA 50 IBC Section Title Section (Number (Number only) only) 1705,1.1 S eaal cases list cases here-includes sus ended ceilin s. 1705.2.1 SE Structural Steel,(see tables per AISC 360-if required include in Structural Plans)._ 1705.2.2 SE Steel construction other than Structural Steel,(see Table 1705.2.2-if reqwired include table in Structural plans). 1705.3 SE Concrete construction,(see Table 1705.3&WAC table 1705.3-if required include table in Structural plans). 1705.4 SE Masonry construction,(see Tables per TMS 420/ACI,530/ASCE 5& TMS 602/ACI 530.1/ASCE 6 if required include tables in structural tans). 1705.5 SE Wood construction. 1705.6 GEO Soils see Table 1705,6-if required include table in Structural plans). 1705.7 SE Driven deep foundations,(see Table 1705.7-if required include table in Structural plans). 1705.8 SE Cast-in-place deep foundations(see Table 1705.8-if required include table in Structural plans). 1705.9 SE Helical pile foundations. 1705.10.I SE Structural Woad for Wind Resistance. 1705.10.2 1 SE I Cold-formed steel li ht-frame construction for Wind Resistance. 1705.10.3 SE Wind-resistin com nents roof or wall cladding). 1705.11.1 SE Structural Steel for Seismic Resistance. 1705.11.2 SE Structural Wood for Seismic Resistance, 1705.11.3 SE Cold-funned steel light-frame construction,for Seismic Resistance. 1705.11.4 SE Designated seismic systems. 1705.11.5 Arch NA I Architectural components. 1705.1L6 ME NA Mechanical and Electrical components. 1705.11,7 SE Storage racks. 1705.11.8 SE Seismic isolation systems. 1705.13 Arch NA Sprayed fire-resistant materials, 1705.14 Arch NA Mastic and intumescent fire-resistant coatings. 1705,15 Arch NA Exterior insulation and finish stems EIFS, 1705.16 Arch Fire-resistant penetrations&joints by Mfg representative.(There are NO WABO certified personnel in this area yet). 1705.17 ME NA Smoke control. 1704.5 SE NA Structural Observation in Seismic Design Category D areas when a structure is a Occupancy Categoy III or IV structure or over 75`AFG AGENCIES AND REGISTERED DESIGN PROFESSIONALS WASO approved special Inspection agencies(SIA-PRINT) SIA1 /�i���S _SIA2 Registered design professional(ROP)in responsible for structural observation(SO) RDP 3 RDP 4 Registered geoterhnical engineer(GE)in responsible for inspection of soils GEO 5 GEO 6 SIGNATURES Registered Design Professionals As the design professional in responsible charge of a portion of this project I have made a reasonable effort to note all required special inspections and structural observations for that portion of the project.*All are required. Name (print) Signature Date *Arch GEO ME *SE 6—If441LAS71Pr,,) CS( �C7 **Owner or Agent **The signature of the owner or owner's agent merely indicates that he or she has reviewed the completed form. ABBREVIATIONS Arch architect GEO geotechnical engineer IBC International Building Code ICCES International Code Council Evaluation Services ME mechanical engineer MCBD Mason County Building Department RDP registered design professional SE structural engineer SI special inspection(IBC 1704) SIA special inspection agency SO structural observation(IBC 1710) WABO Washington Association of Building Officials SPECIAL INSPECTION&STRUCTURAL OBSERVATION TASKS OWNER OR OWNER'S AGENT: -The signature of the owner or the owner's agent merely indicates that he or she has reviewed the completed SI&SO form.The definition of the agency relationship(see 1704.1)is beyond the score of this form. -Attend preconstruction meeting on SI and SO If required. DESIGN PROFESSIONALS: -Include in the contract documents the information on SI,SO and quality assurance required in Chapter 17 -Obtain a copy of County Annex.Complete the form and give a signed copy to the permit applicant prior to permit application. -Attend preconstruction meeting on SI and SO if required. PERMIT APPLICANT: -verify that the inspection agency is registered with WABO by checking the website:htW:/Ivmw wabo orci/soecialinsoection-aaendes -Submit certificate for fabricators approved by ICC Evaluation Services httn'/1www.icc-es.oro/(This eliminates the need for special inspection of shop fabricated components.) CONTRACTORS: -Submit certificate of approval by ICC Evaluation Services if a fabricator supplying items requiring SI has ICCFS approval if required. -Coordinates SI and SO and provide a copy of all required reports to the Mason County inspector -Maintain records of all SI and SO -Correct any non-complying items noted during SI or SO SPECIAL INSPECTION AGENCY -Attend preconstruction meeting on SI if required. -Furnish inspection reports to the Mason County Building Department and provide a copy on site for inspection and RDP -Bring to immediate attention of the Mason County Building Inspector and RDP,any discrepancies which are not corrected by the contractor. -Submit final letter documenting special inspection and resolution of all discrepancies to the Mason County Building Department at PO Box 279,Shelton,WA 98584/FAX: (360)427-7798