Loading...
HomeMy WebLinkAboutCOM2000-00120 Cancelled Change in Tenant - COM Application - 10/18/2000 >R Case number: -001 ao (� Mason Count Y U TENANT REVIEW APPLICATION �'Eomplete the tenant view application and return with floor plan. site plan, pumpers report, and $100.00 fee to the Mason C r rtt 'sance Center, attn. M MacSems, P.O. Box 186, Shelton, WA 98584. The tenant review 1iN&% ivated on Wednesday after the application has been received. During the evaluation Mason County mbers from the Building, Fire Marshal, Environmental Health, Planning, and Public Works offices will identify compliance requirements, if needed, and advise whether a separate building permit will be required. Date: _, _ �J Assessor's Parcel Number: I2-3Z 61 - 1ttZ" 00 Legal Description: Building Site Address: ,�E S/ PO. Method of sewage disposal: O Septic O Sewer- name of district: Water source: O Well O Community Well O Public System, name of system: PEOPLE and FIRMS INVOLVED IN THE PROJECT Name of property owner: Mailing address: Day phone: Contact Person: Message phone: Name of applicant: C_0 ! `eg1UDA)� 11,4120w44, Mailing address: Pp 43ax t-J Day phone: 7 _0//3 Contact person: Message phone: Name of Tenant: Mailing address: Day phone: Contact person: Message phone: PROJECT INFORMATION Proposed business name: Proposed use: Number of employees: Previous business name: -" Previous use: INFORMATION ABOUT STRUCTURE Check one: ,$Detached single level/single tenant single level/multi tenant Multi level/single tenant Multi level/multi tenant Age of structure: Is structure currentl occupied? If not occupied, how long has it begin vacant? aS ��S Circle one: es No Yrs mos. _ List square footage for each floor level Basement: First:36 000 I Mezzanine: Second: Third: Will structure a heated: Type heating fuel: Circle one: -- - Circle one: es No ItIollaD Liquid Propane Natural Gas Oil Type of he ircle one urnace Heat Pump Electric baseboard or wall mount Radiant Will be any changes to the following? Circle yes or no, if applicable: Floor lay-out: Yes CNDo Lighting: Yes �Roo Heating: Yes Exterior Finishes: Yes o Interior Finishes Yes Parking: Yes SNo Number of restrooms provi Number of fixtures i each Is structure ADA Accessible? circle one Yes No Is the structure equipped with a fire sprinkler system? Yeo larm system? Yes No Return this application with: 1 j Floor Plan, 2)Site Plan, 3) dumpers Report, and 4) $100 Fee 1) Floor Plan: Include existing walls,proposed walls,and walls that will be removed. • Draw the floor plan to scale, '/4"= 1 foot min. • Use of rooms • Room Dimensions • Location of all exits and windows (include dimensions) • Location of plumbing and mechanical fixtures • Interior doors with swing radius 2) Site Plan: Note scale • Property lines, easements, & right of ways • Location of all existing structures& dimensions • Distance, in feet, from property line&structures Landscape buffer yards • On-site sewage tanks and drainfields, & reserve • Well location • Surface &stormwater run-off routes • Parking areas (number& arrangement • Location of fire hydrants &vehicle access roads • Slope of property 3) Pumpers Report 4) Fee: $100.00 Intake fee will be collected when submitted. Additional fees will be collected when the permit is issued. 1 ' Office Use Only Pre-Application Review Departmental Review Env. Health Env. Health Planning Planning Public Works Public Works Fire Marshal Fire Marshal Building Building NREC NREC Pre Application required? (circle one) Yes No Building Permit required? (circle one) Yes No Engineering Required? (circle one) Yes No Occupancy Classification: Occupancy Change? (circle one) Yes No Occupancy classification change from to Type of construction Occupant load calculated: persons. Existing occupant load design persons. Fee Schedule Building P"ermtt # MASON COUNTY BUILDING 111 426 W. CEDAR SHELTON, WASHINGTON 98584 (360) 427-9670 ORRECTION NOTICE Job Locations This structure has been inspected by Mason County Building Department and the following VIOLATION of County Laws and Ordinances has been found: Items Listed below must be corrected to gain code compliance Z���i� � � �-� i You are hereby notified that the above corrections shall be made BEFORE PROCEEDING WITH ANY FURTHER WORK ❑ Call for re-inspection when corrections are made before continuing ❑ Make corrections, items will be checked on next inspection ❑ OK to ❑ This is not a complete inspection Department Date Inspector �i LL nn NOT MnV ' TH1 TA,c ,G Printed by Mike Barth 7/21/2000 1:46pm -------- ------------------------------- From: Mike Barth To: Dave Salzer, Kelly Mayo Subject: fwd: Belfair Drug Building --------------------------------------- ===NOTE====------=====7/21/2000==11:02= Dave, I was in the true value hardware store yesterday and saw where they have disassembled the self closers on the fire doors between the two large portions of building, and have propped the doors open so that customers can freely walk between the two sides. This is a required fire wall between what used to be Belfair Drug and the hardware store, and the door is (or was as the case may be) a 1 1/2 hour rated door assembly. They have not yet applied for a tenant change, nor have they obtained any permits for remodeling. It appears that there are probably exiting issues that also need to be looked at. They currently have both sides open to the public. According to Kelly, he spoke with a Scott McLenden on several occasions (5/30, 6/6, 6/21) about what will be required for the change of use/change of tenant, and Kelly told them not to proceed until they have applied for the tenant review and submitted all necessary layouts, exiting, etc. Kelly also talked to the contractor, Skip at the counter about the same issues, specifically about the fire wall and how the building will exceed the allowable areas allowed by the UBC if this area separation wall is breached. I know you are busy, but I thought you would be interested in this, and that this circumstance might warrant a visit by you. Fwd=by:=Dave=Salzer===7/21/2000==1:44=P Fwd to: Mike Barth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I would ask that Building advise the occupant that the issues you addressed are significant and may result in the revocation of an Occuapncy Certificate unless resolved asap. --------------------------------------- Page: 1 Mode : INQUIRY Personal Property Master Parce h# 10 05300 COMMERCIAL Bus . Name : BELFAIR TRUE VALUE #308 Loc : 51 NE STATE HWY 300 - BELFAIR Assoc R/P: State of Incorporation: WA Taxpayer: BELF 4475 BELFAIR TRUE VALUE #308 T/P Chg Dt : Owner: K*K* 1000 KKLD, INC T/P Chg By: Form Status : W WORKED Form Returned: 3022000 Penalty °s Tax Code : 0276 1 403 A P3 F2 L C H W1 Tax Roll : R REGULAR Land Use : 5251 HARDWARE Tax Status : TX TAXABLE Comments : ABS # Description Amount 2 MANUF & CONTRACT EQ Change Reason: AR ANNUAL REVALUATION 3 OTHER EQUIPMENT 35165 Change Date : 6/02/1998 4 SUPPLIES & MATERIALS 250 Change By: DLC 8 IMPROVEMENTS EX LAND 8a IMPROVEMENTS/LEASED 8b IMPROVEMENTS ONLY 8c LEASED EQUIPMENT 10 OTHER P/P H-O-W Exempt Cd Total Assessed Value 35415 Sr Cit Code H-O-W Exemption Sr Cit Exempt AV Net Assessed Value 35415 CMD 6 - Comments Inquiry Type VL CMD 7 - EOJ HELP Allowed v Vl� Memorandum To: Mason County Building Dept From: Tom I lerstad Date: 06/20/00 Re: Acc hardware in Belfair Scott McLendon has asked me to look into the possibility of bleaching an existing firewall between the new hardware store and the existing Pharmacy store. Being an 'M' occupancy and about 17,000 + square footage in each area I checked the allowable floor area which is 14,000 sf and then the area increas allowable e fr o sprinklers. Under the UBC sec. 505 2 unlimited area it says- "The area of any one- or two-story building of Groups B: f, Division 1 or 2; M, S, Division 1, 2, 3, 4 or S; And 11, Division 5 Occupancies shall not be limited if the building is provided with an approved automatic sprinkler system throughout as specified in Chapter 9, and entirely surrounded and adjoined by public ways or yards not less than 60 feet in width " This building appears to meet this requirement It is sprinklered and has the space around it Also, the Iwo spaces are the same occupancy and would not require an area separation If my observation is wrong, the openings are not going to be too large, the owner could install fire doors that are activated by electromagnetic door holders that would be activated by fire alarm or sprinkler, Thank you for your consideration. If you have any questions please call at 876-6893 Respectfully submitted Torn I Ierstad 296 Tremont St. Port Orchard, WA 98366 t r C�r