RESIDENTIAL BUILDING PERMIT BLD2007-00580
OWNER: REGINA HANNAN RECEIVED: 4/6/2007
CONTRACTOR: MILES BRAINARD CONST INC LICENSE: MILESBCO24QR EXP: 11/6/2007 ISSUED: 8/29/2007
SITE ADDRESS: 2731 NE OLD BELFAIR HWY BELFAIR EXPIRES: 2/29/2008
PARCEL NUMBER: 123093400050
LEGAL DESCRIPTION: TR 5 OF SE SW
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
CARPORT, RETAINING WALL (retaining wall is on the west side of the ST RT 3, L ON ST RT 300, FOLLOW TO OLD BELFAIR HWY TO SITE
carport) ADDRESS ON LEFT
General Information Construction &Occupancy Information Square Footage Information
No. of Bedrooms: Type of Constr.: V-B
Type of Use: SF Insp. Area: No. of Bathrooms: Occ. Group: U-1 Lot Size: Deck:
Type of Work: ACC Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building: Carport-Attached 600
Valuation: Building Height: 14 Occ. Status: Primary Basement:
Manufactured Home Information Setback Information Shoreline & Planning Information
Make: Length: Ft. Front: E 120.0 Ft. Shoreline: Ft. Water Body:
SEPA?: No
Model: Width: Ft. Rear: W 65.0 Ft. Slope: Ft. Shoreline Desi
Side 1: N Ft. 9 Not Applicable
Year: Serial No.: Side 2: S 65.0 Ft. Comp. Plan Desig.: Rural
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Plan Check Fee KS 4/6/2007 $163.31 S12007000
Planning Review Fee KS 4/6/2007 $170.00 S12007000
EH Plan Review TW 4/17/2007 $35.00 S12007000
Building State Fee RTB 8/22/2007 $4.50 S12007000
Building Permit Fee RTB 8/22/2007 $251.25 S12007000
Total $624.06
BLD2007-00580 Please refer to the following pages for conditions of this permit. 1 of 5
CASE NOTES FOR
BLD2007-00580
CONDITIONS FOR
BLD2007-00580
1) The international code requires a fire apparatus access road for every facility, building, or portion of a building that is more than 150'from an approved
access road. Roads are required to meet the minimum Mason County Fire Marshal standards for Fire Apparatus Access Roads up to the point where
such roads co nect with a county maintained public road or to another fire apparatus access road which connects to a county maintained public road.
X
2) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. X �
3) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division.
There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at
1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law.
x
4) X ater quality is not lie degraded to the detriment of the aquatic environment as a result of this project.
5) Prior to final approval, all upland areas disturbed or newly crea ecL by construction activities shall be seeded, vegetated or given an equivalent type of
erosion protection (silt fencing or straw matting). X� 6
6) Approved car dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
x
7) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
X 1403
8) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed.
X 1'/ I%�
9) All other necessary permits from Mason County, Washington State and/or Federal Agencies that are required for this proposed development and
construction must be obtained PRIOR TO SAME DEVELOPMENT AND CONSTRUCTION. X��f'I'
BLD2007-00580 Please referto the following pages for conditions of this permit. 2 of 5
10) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will
r.,zt be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building
Xepartm pyipr to any further inspections being performed or approvals granted.
11) Owner/Agent ',fs responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28.
X
12) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the
corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building
Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or
removal of app oved documents will result in failure of required building inspections.
X ,0 �
13) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use
permit shall be a lied for, reviewed and approved prior to the change.
X �9
14) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X
15) The"approved"site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then
approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the
Xuilding Department nor to any further inspections being performed or approvals granted.
16) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other
vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2).
X 411�2'
17) This structure is limited to U-occupancy use only(private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the
international codes.,ndNason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved.
X
18) Any changes in proposed construction shall be reviewed by the engineer or architect of record and submitted in writing to the Mason County Building
Department prior to construction. All engineering and/or architectural documents are a part of the approved set of plans and shall remain attached
thereto. If documents are removed, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be
charged and shall be collected the Building Department prior to any further inspections being performed or approvals granted.
X
T-
19) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the
State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in
permit revocation.
X
T
BLD2007-00580 Please referto the following pages for conditions of this permit. 3 of 5
20) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact
adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the
stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further
information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access
connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which
is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may
affect your project. n
X
21) All changes to "approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County
X ordinance or regulation, be reviewed and approved by Mason County prior to construction.
22) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED
BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance
with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building
Inspector shall be made prior to requesting additional inspections.
X /YI�g
23) All property lines shall be clearly identified at the time of foundation inspection. X /�
24) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure
to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with
Mason County ordinances and building regulations.
X
25) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for
action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit
holder have prevented a tion from being taken. No more than one extension may be granted.
X
26) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners,
X nnectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material.
27) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure
these structures meet the setback conditions listed.
X_ A �
T •
28) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your
"A
X pproved Site Plan"to ensure t se structures are shown and meet the setback conditions listed.
BLD2007-00580 Please referto the following pages for conditions of this permit. 4 of 5
29) This parcel is located in a smoke management zone. Please contact a fire warden at(360)427-9670 ext. 459 for further information.
X i�
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
C a
OWNER OR AGENT: DATE: �"� !�'— 7
BLD2007-00580 Please referto the following pages for conditions of this permit. 5 Of 5
o CONCRETE MECHANICAL MANUFACTURED HOME
D
o ate By//�� ,a, ��
� Footings f Setbacks 1591�t�AYAl ' Ribbons Z
s Piping D
o i tenor Date Interior•Oahe By Date By Z
o Exterior Date /�4dI BYoOOWV Exterior-Date By
Set-up
Point Load J Isolated Footings INSULATION Date By m
BG!SLAB INSULATION
Date By Data By FIRE DEPARTMENT D
Foundation Walls Floors Date By
Date . a? By Data By DECKS
FRAMING walls Date By
Date By Data By PROPANE TANKS
PLUMBING vault Date By
Date By OTHER
Groundwork Attic
Date By Date By Type.
Date By
O.W.v DRYWALL Type-
Int.Brace Wall Date By W
Date By Date By FINAL INSPECTION p
v Water Line Firs Seperation C
Dale By Date By Date ���j By� p
CD
Pass or Request Inspeok. c
0 Ty of Insp. Fail Date Date Dane By Comments ono
c
-v 9
0
8
a
o'
w
0
s
CD
m
O
J
Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2
Topic Index Contact Info%X"aA);f1g1m%State of
Labor and Industries
Search
Home Safety Claims Et Insurance Workplace Rights Trades 8 Licensing
Find a Law or Rule Get a Form or Publication
Look Up a Contractor, Electrician or Plumber
Printer Friendly Version
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope
of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment
of account and carry general liability insurance.
License Information
License MILESBCO24QR
Licensee Name MILES BRAINARD CONST INC
Licensee Type CONSTRUCTION CONTRACTOR
601909109-Verify_Workers Comp Premium
U BI Status
Ind. Ins. Account 42609602
Id
Business Type CORPORATION
Address 1 PO BOX 1851
Address 2
City BELFAIR
County MASON
State WA
Zip 98528
Phone 3602753470
Status ACTIVE
Specialty 1 GENERAL
Specialty 2 UNUSED
Effective Date 11/19/1998
Expiration Date 11/6/2007
Suspend Date
Separation Date
Parent Company
Previous License MILESC*090JH
Next License
Associated
License
https://fortress.wa.gov/lni/bbip/Detail.aspx?License=MILESBCO24QR 8/29/2007
PLA ING �o N�
-p°
�t , tp
PLANNING
�2 �a
PLANNING : �,�
ALL SETBACKS ARE MEASURED
FROM THE FURTHEST 5
PROJECTION OF THE BUILDING S,A
�A L
Ae vF
v�rs 9 i'tpfz k
OFF H
.� 'LPL S�.
V?
N p�
a y
MASON COUNTY PERMIT NO.
BUILDING PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT INFORMATION CONTRACTOR INIF R ATIO
Owner ,: I r ► I ! t l Company Name lr
Mailing Address O Mailing Add ess . CAL `� e
,J t f - Cit '` State i ode I` .` :'
City -r,' I a t_ State Zip Code Y �EF
"° Other Ph. Phone `�— 410 Other Ph.� S`d -
Phone C" Ex `
Lien/Title Holder Contractor Reg. k' p.
E mail address E Mail Address
Drivers Lic.# DOB Drivers Lic.# DOB
SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic_ Existing Septic
Connect to Water System Name of Water System
Well Sewer System Name of Sewer System
PARCEL INFORMATION - 12 Digit Parcel No. a '. - `77 / Y Fire District
Legal Description t"' '♦i" -
Site Address (Please include street name, street number and city) F E•t 3(
Directions,to site � � l " "
Will timber be cut and sold in parcel preparation?Yes/ No
Is property within 200'of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff / Stream Slopes or Bltaffs /o
Is this permit submittal thytesult of a Stop Work Notice,Correcfigp Notice or other enforcement action?Yes/No
TYPE OF JOB - New Add—Alt— Repair ' they - PRIMARY RESIDEN [} SEASONAL ❑
--- y
Use of Building Describe Wori<
No. of Bedrooms No. of Bathrooms Squ t°e oota _e,::�AsfF•loor 2ndFloor
3rd Floor Basement Deck Cov k Other Sq. ft.
Garage-- Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit? Yes/ No
Installer Name Certification No.
OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all
the necessary parties. If permission is required from any easement holder or any other party in interest regardirfg this application or the work
proposed in the application, I have obtained permission from them to apply for this permit and conduct the work ptopowd. The owner or
agent on owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above
described property and structure for review and inspection. This permit/application becomes null &void if work or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY
MEANS OFA EROGRESS INSPEC IOtgvACTIV OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION.
X Date:
caner/Owners Representative/Contractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT Accepted by:.''l �'. f s Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department 2 7
Planning Department
Environmental Health Department
Fire Marshal
FEES
Building Permit Fee 0 — a3 Site Inspection
Plan Review Fee (D 3. 3 EH Review Fee
Plumbing & Base Fee Planninq Review Fee
Mechanical & Base fee `'—� Other
Wood/Gas/ Pellet Stove Fee State Fee s�
Violation Fee -J.1-4 Pre-Paid at Submittal
Valuation $ TOTAL FEES
FORM MUST BE COMPLETED ININK MASON COUNTY PERMIT NO. dV !^Vu
PLEASE PRESS HARD BUILDING PERMIT APPLICATION
426 W. Cedar• P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the web www.co.mason.wa.us
APPLICANT,WORMATIO CONTRACTOR INF R ATIO
Owner h Company Name _
Mailin A dress Mailina Add Z - 61el
City State Zip Code City StateUkA Zip Code
Phone Other Ph. Phone - 4_7 Q Other Ph.
Lien/Title Holder Contractor Reg. Exp.
E mail address E Mail Address
Drivers Lic.# DOB Drivers Lic.# DOB
SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Connect to Water System Name of Water System
Well Sewer System Name of Sewer System
PARCEL INFORMATIO - 12 Di Parc No. - Fire District
Legal Description
Site Address (Please include street name, street number and city) 7
irecti ns to site k'nD
ft� Set
Will timber be cut and sold in parcel preparation? /No
Is property within 200'of Saltwater Lake River/Creek Pond
Wetland Seasonal Runoff Stream Slopes or Bluffs
Is this permit submittal th,94esult of a Stop Work Notice,CoggDfion Notice or other enforcement action?Yes/No
TYPE OF JOB - NewV Add Alt Repair ter ARY RESIDE SEASONAL ❑
Use of Building Describe Work
No. of Bedrooms No. of Bathrooms Squ oot e- or 0 2n oor
3rd Floor Basement Deck Cov k er Sq. ft.
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit? Yes/ No
Installer Name o.
OWNER/BUILDER Acknowledges submission of inaccurate information may res NepC4 d tirmit revocation.
Acknowledgement of such is by signature below. I declare that I am the owner,owners le al re resents he contractor. I further declare
that I am entitled to receive this permit and to do the work as proposed in the applicatio M� r��tt� I ave obtained the permission from all
the necessary parties. If permission is required from any easement holder or any other party in i egarding this application or the work
proposed in the application, I have obtained permission from them to apply for th r�p i nd conduct the work proposed. The owner or
agent on owners behalf, represents that the information provided is accurate ands 1@o�[esjpfif County access to the above
described property and structure for review and inspection. This permit/application becomes nuTT((& i f rk or authorized construction is
not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY
MEANS OFABROGRESS INSPEC 101�1ACTIV OF THIS PERMIT APPLICATION OF 180 A S WILL INVALIDATE THE APPLICATION.
X Date: U
wner/Owners Representative/C ntractor (indicate which one)
FOR OFFICIAL USE BEYOND THIS POINT Accepted by: 6 all u Date
DEPARTMENTAL REVIEW APPROVED DENIED NOTES
Building Department
Planning Department
Environmental Health Department
Fire Marshal
FEES
Building Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing & Base Fee Planning Review Fee
Mechanical & Base fee Other
Wood/Gas/ Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal
Valuation $ TOTAL FEES
9�
PLANNING
t j4 y��N
z -o Z O cc`9t1�
cn - N� GAF
I m ----
r•� -
L7
Z� •
--
�
e4<Pon: fvF
Fitt-�
*D f'Tru / iA-1 a
o j 4vusE 4P2tx
i44c ' rOFF Huj-1
t!1
J�a-b�b` btu
N. L. OLSON & ASSOCIATES, INC. IN'TrVEQ
2453 Bethel Avenue
P.O. Box 637
PORT ORCHARD, WASHINGTON 98366 DATE JOB NO
(360) 876-2284
FAX (3 ) 876-1487 ATTENTION
TO
RE
WE ARE SENDING YOU �ttached ❑ Under separate cover via the following items:
❑ Shop drawings ❑ Prints ❑ Plans ❑ Samples ❑ Specifications
❑ Copy of letter ❑ Change order ❑
COPIES DATE NO. DESCRIPTION
THESE ARE TRANSMITTED as checked below:
❑ For approval ❑ Approved as submitted ❑ Resubmit copies for approval
❑ For your use ❑ Approved as noted ❑ Submit copies for distribution
❑ As requested ❑ Returned for corrections ❑ Return corrected prints
❑ For review and comment ❑
❑ FORBIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS
COPY TO
SIGNED:
M enclosures are not as noted,kindly notify us at once.
A
k-AI,i N.L.01son&Associatesinc.
Engineering, Planning and Land Surveying.
August 16, 2007
Miles Construction
PO Box 1851
Belfair, WA 98528
RE: Carport Framing Modifications for Hannon Remodel
Dear Mr. Brainard,
In June 2007, 1 provided analysis for the remodel at 2731 Old Belfair Highway. I
designed a stemwall foundation and a retaining wall foundation for the garage.
One of the walls that I assumed was going to be framed will actually be built with a post
and beam. For this wall,the foundation detail I provided for wall thickness and
reinforcing is still acceptable, but the anchor bolts and sill plate can be removed. Posts
on this wall shall be 4x6 treated posts with Simpson PB46 Bases cast into the concrete
stemwall and BC46 caps connecting the posts to the Glue-lam beam above.
If the plans examiner or yourself have any questions, please feel free to contact me at
(360) 876-2284.
Sincerely,
A ?0�1
Matthew Za locki, P.E.
N.L. Olson& Associates, Inc.
M.Zq I p
'S 0 AS 00
O.t �GIS7Tii� 1,y�4
�SS%NALV:�'G
EXPIRES !L/o 0
2453 BETHEL AVENUE, P.O. BOX 637, PORT ORCHARD, WASHINGTON 98366
(360) 876-2284 FAX (360) 876-1487
/ 3 a� - 31-[ - anal SNO
7-'774,
RECEIVED
MAY 161007
MASON COUNTY
Li
4�Otli
WIASflN COUNTY
(P
PLANNING =�7 �
.If j4
0G��t�
0-
0 > 103
rrl 0
z
z � n \2 O
0 >
rl
C) ryl
co 0
I o r-
0 z >
z
U)
ri
o
vc
OF
Hoosz: 4pfzcx
t4o ' OFF HLa
44S
in S7,
C)C