Loading...
HomeMy WebLinkAboutGRD2005-00011 Cancelled - GRD Permit / Conditions - 8/4/2005 Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext. 352 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton, WA 98584 LAND MODIFICATION BUILDING PERMIT GRD2005-00011 OWNER: KURT OLSON RECEIVED: 6/17/2005 CONTRACTOR: LICENSE: EXP: ISSUED: 8/4/2005 1 ENGINEER: LICENSE: EXP: EXPIRES: SITE ADDRESS: LOG YARD RD BELFAIR PARCEL NUMBER: 123217500060 LEGAL DESCRIPTION: TR 6 OF ILLS 02-0002 PROJECT DESCRIPTION: DIRECTIONS TO SITE: 7900 CUBIC YARDS BELFAIR TO LOG YARD RD TO SR3 Inspection Area: Fill?: Comp. Plan Desig.: Urban Growth Grading?: IRO Desig.: Cutting?: Shoreline Desig.: Unknown Area Graded: SEPA?: Yes Cubic Yards: 7,900.00 FEES Type By Date Amount Receipt Grading Plan Check Fee KS 6/17/2005 $49.25 S12005000 Planning Review Fee KS 6/17/2005 $155.00 S12005000 Public Works Review AT 6/29/2005 $78.44 612005000 Public Works Review AT 7/20/2005 $39.22 B12005000 Grading Permit Fee TLG 8/1/2005 $296.00 612005000 Total $617.91 GRD2005-00011 Please refer to the following page(s)for conditions of this permit. 1 of 4 CONDITIONS FOR GRD2005-00011 1) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. � 1 X 2) All upland areas disturbed or ne y_. reated by construction activities shall be seeded, vegetated or given some other equivalent type of protection against erosion. X �, ; 3) Proper disposal of constru ti(aQ debris must be on uplands, in such a manner that debris cannot enter wetlands or cause water quality degradation of adjacent waters. X if 4) Approved per site plan and topographic cross-section. X C� 5) Access Roads to the site must not be degraded as a result of work. X 6) A 20 foot wide fire apparatus access road is required to extend within 150 feet of any portion of the exterior walls of the building. An unobstructed vertical clearance of 13 feet, 6 inches is required. Dead-end fire apparatus access r a�lstTger than 150 feet are required to have an approved turnaround. The maximum grade of a fire apparatus access road is 14%. X yy 7) ALL CLEARING,CUTTING, GRADING, EXCAVATING, TERRACING, FILLING AND SIMILIAR WORK WILL BE REGULATED BY THE REQUIREMENTS PURSUANT TO THE MASON COUNTY GRADING PERMIT STANDARDS ADOPTED BY RESOLUTION 141-96 and MASON COUNTY CQt ITLE 14, CHAPTER 14.44. X I () 8) All fills shall be compacted to a minimum of 90 percent of maximum density.X� 9) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE TOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAYx 10) The owner/applicant shall provide to Mason County inspection reports prepared by the engineer record, complying with the requirements as noted in Chapter 14.44, section 14.44.220 through 14.44.230. X GRD2005-00011 Please referto the following page(s)for conditions of this permit. 2 of 4 11) Cut and fill slopes shall be setback from site boundaries in accordance with Section 14.44.190. X 12) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS. X L<� '� 13) This permit approval is granted for the grading and construction of stormwater features only and does not grant approval for business operations or construction of structures. X 14) Completion of O & M Covenant requirements and final inspection and acceptance of the completed facilities must meet the satisfaction of Mason County Public Works prior to any occupancy or use of site as indicated. X 15) Fire apparatus access roads standards chapter 14.17 of the Mason County Building Code shall be adhered to. X A rapid access " system is required for this compound. Contact Mason County Fire District#2 at 360-275-6711 for an application and mounting instructions. X This permit becomes null and void if work r construction authorized is not oommenoed within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of con in ation o> ork r �1ro�ress inspection within the 180 day period. Final inspection must be approved before building can be occupied. ' / -Q OWNER OR AGENT: —T DATE: GRD2005-00011 Please referto the following page(s)for conditions of this permit. 3 of 4