Geotechnical Assessment Review Acceptance Letter
November 14, 2014
BLUE STAR PROPERTIES LLC
BOB DRESSEL
P O BOX 275
Case No.: GE02014-00040
Parcel No.: 123217500020
Proiect Description: REVIEW / UPDATE OF GEO INFORMATION FOR FILLAND GRADE SITE
FOR FUTURE DEVELOPMENT
The Geotechnical Assessment for BLUE STAR PROPERTIES LLC has been received and
reviewed by the Planning Department. The assessment was prepared by Michael Staten dated
8/29/2007.
Based on the certification provided by the licensed engineer/geologist, the referenced Geological
Assessment was prepared in general accordance with the requirements in the Mason County
Resource Ordinance, Landslide Hazard Areas 17.01.100.EA. Mason County considers the review
valid until such time as scope of project, site conditions, and/or regulations change. Should the
scope of work, site conditions, and/or regulations change after the original review, then an
addendum from the original author of the assessment may be required to address these changes.
The assessment would only be re-reviewed if a permit for development were submitted after these
changes occur. Mason County does not certify the quality of the work done in this Geological
Assessment.
Please contact me at (360) 427-9670, ext. 365 if you have questions.
Sincerely, *6�1� �-
Allan Borden
Land Use Planner
Mason County Planning Department
Comments:
11/14/2014 Page 1 of 1 GE02014-00040
r
20 C 000 �d
GeoResources, LLC
Ph.253-896-1011 5007 Pacific Hwy. E.,Suite. 20
Fx.253-896-2633 Fife, Washington 98424
August 22, 2014
Blue Star Trust
NE 431 Logyard Road
Belfair, Washington 98528
Attn: Mr. Bob Dressel
Geotechnical Consultation
Blue-Star Re-Grade Phase 1
Logyard Road
Belfair, WA 98528
Job No: BlueStarTrust.LogyardRd2.L2
This letter summarizes our site observations and data review for the Blue-Star Re-
Grade Project, Phase 1 for proposed site development. We previously visited the site and
provided geotechnical documents in a earlier phase of the project in 2009. Included in our
current review was the geotechnical engineering recommendations and design criteria for
the current and next phase of site development, provided by Envirotech Engineering in
2007. We previously visited the site and explored the subsurface conditions by performed
test pits and infiltration tests on a nearby parcel. A copy of the proposed site layout is
illustrated on the attached map, Figure C1.0.
Based on our previous experienced in the site area, our review of the project plans
and the previously geotechnical report, it is our opinion that there have been no significant
changes in site conditions and that the proposed site development remains feasible as
previously described.
We appreciate the opportunity to be of service on this project. Should you have
need of additional information or services please call.
Yours Very Truly,
GeoResources; c'_
In inp G
2223
Brad P. Biggerstaff, LEG Dana C. Biggerstaff, PE
Principal Sr. Engineer
BPB:DCB:bpb
DocID:BlueStarTrust.LogyardRd.Phl.L
Attachm ents:
Figure 1—Site Plan
V.
BLUE STAR RE-GRADE PHASE 1 ■��■
A PORTION OF THE NE 1/4 AND THE SE 1/4 OF SEC. 219 TWN. 23 N., RGE. 01 W. W.M. i
MASON COUNTY, WASHINGTON _
\ PARCEL 1232y-,3mo6o
\ B�IJE STAR PROP�E�R�T�I�ES;PLC T A C O M A SEATTLE SPOKANE TRI-CITIES
/ (UNDER S V'_jTE GRADE k WIIT GRD20OB4=13)
\ / '/� ♦ \ \\ /'^\`— 'I''/'-' / I / �.-J 25 5 North
o th TEt Street,
Suite
300 Tacoma,WFAx WAA 98403
wm
------1 I 1 312 �\ \ \ / -\\\ —i �,!J/ /// /
{ GRAPHIC SCALE Praiect Title!
\\ \ ` a '� _ ✓� I %/i=—\� 0 25 50 ,00 BLUE STAR
`�RCEL 12321-14-00000 \ / �./\ \ \ ,y.�t �_ ( ♦ i I I(� I/
/ I BLUE VTAR PROPERTIES,LLC \\� \\ v �� 1Illll /I 1" FEET RE-GRADE
( , (UND PERA ER SEPARATE GRADE IfT GRD20�&00013) \\ ,. 'I / / I / 6 \ I! PHASE 1
J �!� JII' ,\ PAR
CEL1z321-75 BLUE STAR
\ // �/ 1 �ii 3� Tom, I \ 3-54� �„/// /i'�/� ` \sir— \ uEs gRGPER uc \ 1 f PROPERTIES LLC
> / J ` / / \— 63A9-(hROJECT18fTE) I / / ♦ /_/ _— \ \ \ I {I 1
---_ / _J 1
� -— \ N.E9�a�wA9&%8�
(360)2754411
10,
_ 1 - ------ _- r - \ \wN j`� I��
\ \\\\ (,
e 2140121.10
------ 11- \' \ / —' \��' 1 \ \\\\ �J J 11 rr$ Issue Set & Dote-
------- - --- — -- ' - —'- 77 `912 / \' \ \\
------�,s --_ -- -- _----_—— —_3;0= _——__----------- — „ t ,'' \' I \ \\\\ \\I �/ PERMIT
306--- ------------------------- -
-_-_--_-_---__ --_- ---_--_---_---- _-------------- `_`tea
_--_---( ft -- _-----___ _302—___— ———_———_— _ -_ _=-T' —'� - 3V — �r� � 1 // '� / ( 1 2014.08.06
-4G=YARD" _\1 � � \ ,- - \ �,/ - ry/ �\ �1 \\ $�o i \\\-
=y=-�--i _
(PRiVATF RETr` }__3� — �1� /
StoNAL ' II
NAlt- ER08'-
L-276— `1 \ I / / / / / / / / / / / r E:1,52791
f 1 / / / / / / / / i / / ♦ l \ / / Qi c` ncc
AN413 0z--i'1 / \
-rtEemT Two cal-
:178ses.zzl7
e /
nsz9z6.0ss9
1 ELEN.331�13
TESC LEGEND
CL i m■In a m®® CLEARINGIPROJECT LIMITS
SF ® SILTATION FENCE k
CE CONSTRUCTION ENTRANCE 8 F
0
Revisions t
Sheet Title
T.E.S.C. &
GRADING PLAN
- � s
e g
Designed bv: Drown bv. Checked br a
STK STK JLM 0
Know whaVs below. f
Call before you dig. Sheet No.
THESE DRAWINGS ARE NOT TO BE 1 O s
USED FOR CONSTRUCTION UNLESS
SIGNED BY THE REVIEWING AGENCY