Loading...
HomeMy WebLinkAboutBLD2019-00144 Final Window Replacement - BLD Permit / Conditions - 4/1/2019 INSPECTION CARD MASON COUNTY Mason County COMMUNITY SERVICES 615 W. Alder St. Bldg. 8, Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us PERMIT# BLD2019-00144 PROJECT ADDRESS 161 NE Riverhill Ln Belfair, WA 98528 PARCEL# 123215100006 PROJECT DESCRIPTION WINDOW REPLACEMENT SIZE FOR SIZE 13 WINDOWS IN TOTAL OWNER REANNE N STEWART ADDRESS 161 NE RIVERHILL LN PHONE CONTRACTOR RENEWAL BY ANDERSEN OF WA ADDRESS 7433 5TH AVE S PHONE 206.336.7434 CONTRACTOR LICENSE RENEWAW856K6 LENDER INSPECTION INSP DATE Comments INSPECTION INSP I DATE Comments �BLD-Final Inspection / ss A Mason County MASON COUNTY Mason County Community Services COMMUNITY SERVICES 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us BLD2019-00144 WINDOW REPLACEMENT PROJECT DESCRIPTION: WINDOW REPLACEMENT SIZE FOR SIZE ISSUED: 02/20/2019 13 WINDOWS IN TOTAL SITE ADDRESS: 161 NE RIVERHILL LN BELFAIR EXPIRES: 08/19/2019 PARCEL: 123215100006 APPLICANT: REANNE N STEWART OWNER: REANNE N STEWART 161 NE RIVERHILL LN 161 NE RIVERHILL LN BELFAIR,WA 98528-9682 BELFAIR,WA 98528-9682 GENERAL CONTRACTOR'S LICENSE: RENEWAL BY ANDERSEN OF WA License: RENEWAW856K6 7433 5TH AVE S Expires: 05/21/2019 SEATTLE,WA 98108 206.336.7434 FEES: Paid Due Window Replacement in $120.00 $0.00 Existing Openings State Fee-Residential $6.50 $0.00 Totals : $126.50 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection CONDITIONS " All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. " The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. Printed by:Ariane Paysse on:02/20/2019 03:32 PM Page 1 of 3 i Mason County MASON COUNTY Mason County Community Services COMMUNITY SERVICES 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us WINDOW REPLACEMENT BLD2019-00144 * Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer specifications and in accordance with IRC Section R315. Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level of the dwelling. EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or created. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. * Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC R403, applicable sections of the IRC, and IMC. Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including infiltration and ventilation. Design calculations shall be available for inspection during inspection. Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure- sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B and shall be marked 181E-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches(38 mm) and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint. Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation instructions. Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be insulated to R-8 DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not required if the air handler and all ducts are located within the heated space. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. Printed by Ariane Paysse on 02/20/2019 03:32 PM Page 2 of 3 r � Mason County MASON COUNTY Mason County Community Services COMMUNITY SERVICES 615 W. Alder St. Bldg. 8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us WINDOW REPLACEMENT BLD2019-00144 * Adopted IECC/Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U- Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances overning this type of work will be complied with whether specified herein r not. The g ing of a p it does not presume to give authority to violate or cancel the provisions any^other s e/local law reg lating construction or the performance of construction. Issued By. Contractor or Authorized Agent: Date: 201,P b I Printed by:Ariane Paysse on:02/20/2019 03:32 PM Page 3 of 3 MASON COUNTY COMMUNITY SERVICES Permit No: j3d 2l WI qy PERMIT ASSISTANCE CENTER: : •BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL 615 W.Alder Street,Shelton,WA 98584 • Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone C/ Belfair.(360)275-4467•Phone Elma:(360)482-5269 BUILDING PERMIT APPLICATION PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: e1y. 10 2019 NAME: NAME: I- &I AP bFkX&:/J MAIL G SS: MAILING ADDRESS: "s CITY: TATE: ZIP: CITY: 5�/I E STATE:J��ZIP: "Q@t PHONE PHONE-1 CELL: PHONE#2: EMAIL: irAfop r b a k; . Conn EMAIL:Qp G1�1P UCVJIt V n� E Q_P� L&I RE #CfTf2E/�IF,W41 SS('eMXP. PRIMARY CONTACT: OWNER CONTRACTOR❑ OTHER❑ NAME EMAIL tCP.AnII�SlPiva `�6�Ses�a C tJ MAILING ADDRESS CITY STATEW& ZIP � PHONE iftA— — CELL f1 B PARCEL INFORMATION: //�� f� PARCEL NUMBER(12 Digit Number) ( f —V Q V ZONING LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT SITE ADDRESS 1IQ N ­aU E(Q k�1L.L IJ CITY�_ l}t� DIRECTIONS TO SITE ADDRESS IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO1 9j IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): v SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑ TYPE OF WORK: NEW❑ ADDITION❑ ALTERATIION❑ REPAIR;K OTHER USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc..)2Lj e Ice, IS USE: PRIMARY,- SEASONAL❑ NUMBER OF BEDROOMS_3__ NUMBER OF BATHROOMS HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Part[s)ofBl ❑ NO I 1 DESCRIBE WORK IYC0J�,Crii / 4)v— Elea- SQUARE FOOTAGE:(propose+existing) 1 ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft. DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft. GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑ MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL YEAR LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC SEWER❑ / NEW❑ EXISTING,®' PLUMBING IN STRUCTURE? YES.®' NO❑ Ifyes,attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT. EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF TINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT LI ATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON COUNTY CODE 14.08.42) X �reb c q Si WNER Must signed ned by the OWNER Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH