HomeMy WebLinkAboutBLD2019-00144 Final Window Replacement - BLD Permit / Conditions - 4/1/2019 INSPECTION CARD
MASON COUNTY Mason County
COMMUNITY SERVICES
615 W. Alder St. Bldg. 8, Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
PERMIT# BLD2019-00144 PROJECT ADDRESS 161 NE Riverhill Ln Belfair, WA 98528
PARCEL# 123215100006 PROJECT DESCRIPTION WINDOW REPLACEMENT SIZE FOR SIZE 13 WINDOWS IN
TOTAL
OWNER REANNE N STEWART ADDRESS 161 NE RIVERHILL LN PHONE
CONTRACTOR RENEWAL BY ANDERSEN OF WA ADDRESS 7433 5TH AVE S PHONE 206.336.7434
CONTRACTOR LICENSE RENEWAW856K6 LENDER
INSPECTION INSP DATE Comments INSPECTION INSP I DATE Comments
�BLD-Final Inspection / ss
A
Mason County
MASON COUNTY Mason County Community Services
COMMUNITY SERVICES
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
BLD2019-00144 WINDOW REPLACEMENT
PROJECT DESCRIPTION: WINDOW REPLACEMENT SIZE FOR SIZE ISSUED: 02/20/2019
13 WINDOWS IN TOTAL
SITE ADDRESS: 161 NE RIVERHILL LN BELFAIR EXPIRES: 08/19/2019
PARCEL: 123215100006
APPLICANT: REANNE N STEWART OWNER: REANNE N STEWART
161 NE RIVERHILL LN 161 NE RIVERHILL LN
BELFAIR,WA 98528-9682 BELFAIR,WA 98528-9682
GENERAL CONTRACTOR'S LICENSE: RENEWAL BY ANDERSEN OF WA License: RENEWAW856K6
7433 5TH AVE S Expires: 05/21/2019
SEATTLE,WA 98108
206.336.7434
FEES: Paid Due
Window Replacement in $120.00 $0.00
Existing Openings
State Fee-Residential $6.50 $0.00
Totals : $126.50 $0.00
REQUIRED INSPECTIONS
BLD-Final Inspection
CONDITIONS
" All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
" The stamped approved site plan is required to be on-site for inspection purposes. If an inspection is requested and the
approved site plan is not on site, approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule,
minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being
performed or approvals granted.
Printed by:Ariane Paysse on:02/20/2019 03:32 PM
Page 1 of 3
i
Mason County
MASON COUNTY Mason County Community Services
COMMUNITY SERVICES
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
WINDOW REPLACEMENT BLD2019-00144
* Carbon monoxide alarms, listed as complying with UL 2075 shall be installed in accordance with manufacturer
specifications and in accordance with IRC Section R315.
Alarms shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each level
of the dwelling.
EXISTING DWELLINGS shall be equipped with carbon monoxide alarms when alterations (including addition or alteration of
fuel burning appliances), repairs, or additions requiring a permit occur, or when one or more sleeping rooms are added or
created.
* All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building
Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration.
Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No
more than one extension may be granted.
* Installation of heating equipment in a single-family residence shall meet the requirements of the current IECC/WSEC
R403, applicable sections of the IRC, and IMC.
Heating equipment shall be sized in accordance to ICC/WSEC, Section R403.7. Heating and design load calculations for the
purpose of sizing HVAC systems are required and shall be calculated in accordance with accepted practice, including
infiltration and ventilation. Design calculations shall be available for inspection during inspection.
Referencing IRC M1601.4, all ducts, air handlers, filter boxes, and building cavities shall be sealed. All joints of duct
systems and seams shall be made substantially air tight by means of tapes, mastics, liquid sealants, gasketing or other
approved closure systems. Closure systems used with rigid fibrous glass ducts shall comply with UL181A and shall be
marked 181A-P for pressure-sensitive tape, 181A-M for mastic or 181 A-H for heat-sensitive tape. Closure systems used
with flexible air ducts and flexible air connectors shall comply with UL181 B and shall be marked 181 B-FX for pressure-
sensitive tape or 181 B-M for mastic. Duct connections to flanges of air distribution system equipment or sheet metal fittings
shall be mechanically fastened. Mechanical fasteners for use with flexible nonmetallic air ducts shall comply with UL 181 B
and shall be marked 181E-C. Crimp joints for round metal ducts shall have a contact lap of at least 1-1/2 inches(38 mm)
and shall be mechanically fastened by means of at least three sheet-metal screws or rivets equally spaced around the joint.
Closure systems used to seal metal ductwork shall be installed in accordance with the manufacturer's installation
instructions.
Duct tape is NOT permitted as a sealant on any ducts. When ducts are located in unheated spaces the ducts hall be
insulated to R-8
DUCT TIGHTNESS TESTING shall be conducted by person(s)trained to perform such testing. A signed affidavit
documenting test results in accordance to IECC/WSEC Section R403.3.3 shall be provided to the Mason County Building
Department prior to the final occupancy inspection. Affidavit forms are available on at the WSU-Energy Program website
titles, "Duct Leakage Affidavit" or"Duct Leakage Testing Results (Existing Construction)." Duct tightness testing is not
required if the air handler and all ducts are located within the heated space.
* CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING
DEPARTMENT AND THE ADOPTED BUILDING CODE.
The construction of the permitted project is subject to inspections by the Mason County Building Department. All
construction must be in conformance with the international codes as amended and adopted by Mason County. Any
corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting
additional inspections.
Printed by Ariane Paysse on 02/20/2019 03:32 PM
Page 2 of 3
r �
Mason County
MASON COUNTY Mason County Community Services
COMMUNITY SERVICES
615 W. Alder St. Bldg. 8
Shelton, WA 98584
360-427-9670 ext 352
www.co.mason.wa.us
WINDOW REPLACEMENT BLD2019-00144
* Adopted IECC/Washington State Energy Code Compliance has been approved as follows:
Heat Type: Electric or other than electric, Compliance Method: Prescriptive option Marine-4C, Window(Max U-
Factor):0.30, Skylight (Max U-Factor):0.50, Doors (Type/Max U-Factor):0.30 or less, Wall insulation R-21, Floor insulation
R-30, Ceiling Insulation min. R-49, Vault Insulation R-38, and Slab Insulation R-10.
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
* All building permits shall have a final inspection performed and approved by Mason County Building Department prior to
permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property
records on file with Mason County as being non-compliant with Mason County ordinances and building regulations.
* Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly
corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of
pressure treated material.
* Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance
with Mason County Title 14.28 and 14.17.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances overning this type of work will be complied with whether
specified herein r not. The g ing of a p it does not presume to give authority to violate or cancel
the provisions any^other s e/local law reg lating construction or the performance of construction.
Issued By.
Contractor or Authorized Agent: Date: 201,P b I
Printed by:Ariane Paysse on:02/20/2019 03:32 PM
Page 3 of 3
MASON COUNTY COMMUNITY SERVICES Permit No: j3d 2l WI qy
PERMIT ASSISTANCE CENTER: :
•BUILDING•PLANNING•PUBLIC HEALTH•FIRE MARSHAL
615 W.Alder Street,Shelton,WA 98584
• Phone Shelton:(360)427-9670 ext.352•Fax:(360)427-7798 Phone C/
Belfair.(360)275-4467•Phone Elma:(360)482-5269
BUILDING PERMIT APPLICATION
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: e1y. 10 2019
NAME: NAME: I- &I AP bFkX&:/J
MAIL G SS: MAILING ADDRESS: "s
CITY: TATE: ZIP: CITY: 5�/I E STATE:J��ZIP: "Q@t
PHONE PHONE-1 CELL:
PHONE#2: EMAIL: irAfop r b a k; . Conn
EMAIL:Qp G1�1P UCVJIt V n� E Q_P� L&I RE #CfTf2E/�IF,W41 SS('eMXP.
PRIMARY CONTACT: OWNER CONTRACTOR❑ OTHER❑
NAME EMAIL tCP.AnII�SlPiva `�6�Ses�a C tJ
MAILING ADDRESS CITY STATEW& ZIP �
PHONE iftA— — CELL f1 B
PARCEL INFORMATION: //�� f�
PARCEL NUMBER(12 Digit Number) ( f —V Q V ZONING
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITE ADDRESS 1IQ N aU E(Q k�1L.L IJ CITY�_ l}t�
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO1
9j
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check all that apply): v
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW❑ ADDITION❑ ALTERATIION❑ REPAIR;K OTHER
USE OF STRUCTURE(Residence,Garage,Commercial Bldg,Etc..)2Lj e Ice,
IS USE: PRIMARY,- SEASONAL❑ NUMBER OF BEDROOMS_3__ NUMBER OF BATHROOMS
HEATED STRUCTURE? YES(Whole Bldg)❑ YES(Part[s)ofBl ❑ NO I 1
DESCRIBE WORK IYC0J�,Crii / 4)v— Elea-
SQUARE FOOTAGE:(propose+existing)
1 ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC SEWER❑ / NEW❑ EXISTING,®'
PLUMBING IN STRUCTURE? YES.®' NO❑ Ifyes,attach completed Water Adequacy Form
PERIMETER/FOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF TINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT LI ATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
COUNTY CODE 14.08.42)
X �reb c q
Si WNER Must signed ned by the OWNER Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH