HomeMy WebLinkAboutFIR2008-00022 - FIR Permit / Conditions - 9/9/1986 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext. 352 Shelton, WA 98584 l� FIRE PROTECTION PERMIT FIR2008-00022 APPLICANT: TIENDA MEXICANA LUPITA'S RECEIVED: 4/3/2008 CONTRACTOR: H I J FIRE& SAFETY 206-353-9123 LICENSE: HIJFIS*988KO EXP.. 5/20/: ISSUED: 4/17/2008 SITE ADDRESS: 24090 NE STATE ROUTE 3 SUITE F BELFAIR EXPIRES: 10/17/2008 PARCEL NUMBER: 123283290030 LEGAL DESCRIPTION: LOT: B OF SP#178 PTN TR 3 OF NW SW PROJECT DESCRIPTION: Hwy 3 to address GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: N Zones: Heat Detectors: Wet Chemical?: Y Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:()- Second Floor: Auto Fire Alarm?: Third Floor;: Sprinkler System Plan $102.38 $102.38 Sprinkler System Permit $157.50 $157.50 Total: $259.88 $259.88 FIR2008-00022 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FIR2008-00022 CONDITIONS FOR FIR2008-00022 1.) The fire suppression system is required to be UL300 compliant. X . A type K fire extinguisher is required to be installed within 30 feet of the cooking appliances and no closer than 10 feet.. X iA T A automatic shut off for the gas/power to the cooking appliances must be installed that is UL listed and will shut off the gas/power when the fire suppression system is activated. x to .T All equipment, appliances and appurtenances must be installed per the manufactures installation specifications (listing). X r-k This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The ownerorthe agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWN ER OR AGENT: F W DATE:. o FIR2008-00022 Please refer to the following pages for conditions of this permit 2 of 3 RECEIVED MASON COUNTY FIRE MARSHAL >a?w l Mason County Bldg. III 426 W Cedar St APR 0 3 2008 PO BOX 186 Shelton,WA 98584 1, (360)427-9670 Ext.273 _SELFAIR OFFICE Permit # Mason County Fire Protection System Permit Application Incomplete application will not be accepted Owner: Phone#: Mailing Address: City: State: Zip: Site Address: ,2 City. 1 State: Parcel#: Legal Description: Lien/Title Holder: Address: jo 0 O B 3 City: Stater Zip:98 Contractor: �' Phone #: Address: City: State:/Z/M Zip: 1 Contractor Registration#: ILIX Expiration Date: ,?cue BuildingSquare Footage(existing&proposed): 1" / 2nd / '3rd / q g � "' " g Building Use: CAr�.V trot_Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry New System: Standpipe: Wet Dry Modification: AFA: Hood&Duct: Dry Chem: Wet Chem: V _ Fire Pump: UL certified Monitoring company: Phone #: Contractors Bid Price: \\CLUSTER]_HOME_SERVER\HOME\COMMON\BU(LD[NG\Fire Protection System Permit Application.doc i Plan Submittal Requirements Your plan submittal shall include the following_ • Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc. • Cut sheets and/or references for all new devices. • / e ri 1 new d ex' v'Location d sc phon of al an existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits, devices, and end—of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$150.00. A plan review fee will be calculated at 65%of the permit fee and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: Date: +-- \\CLUSTERI_HOME_SERVER\HOME\COMMON\BUILDING\Fire Protection System Permit Application.doc UPON ACTIVATI❑N OF SYSTEM, EXHAUST FAN SHALL REM61N 41BER45ING AND MAKE-UP AIR SHALL MU 1z.OFFI ALL FUEL AND POWER UNItER f4bODFO SHUT DOWN DETECT1WN "�'TH�450'F FUSIBLE LINK U w a� ry EMT c 12' HOOD BLACK PIPE 18 'X 18 ' DUCT RANGE GUARD GALLON _ _ _ _ _ _ _ _ _ 1 WET SYSTEM \ UL MAKE UP \ 300 AIR ULM X I 0 MANUAL PULL CJ STATIO C * C, x/ GAS VALVE �srdeK i l�l�i�N I PoT � y�'a HIJ FIRE & SAFETY HIJFIS)K988K0 (206) 353-9123 Q1 TOTAL TWO FLOW POINT PLENUM, TWO ADP NOZZLE RANGE GUARD O TOTAL TWO FLOW P❑INT DUCT, TWO ADP NOZZLE F I R E S U P P R E S S I ❑ N SYSTEM �/,ciT sTack�T o r4F ,R Il0��1c� SCALE, �' = 1'0• APPROVED BY. DRAWN BYl HIJ ® 7VO 420&J 1ti'7 emu' �' �- 7&,IoL R DATE- .3-25--Oe d JAMES HWANG SCPH-00798 REVISED- 5 77,tJo 1�KisV 1,41T /F^,Ark.. BUSDESS NAME, r/C BUSINESS LOCATION, .4 GALL❑N =/2 FLOW POINTS. T❑TAL /Q FLOW P❑INTS USED RAKE GUARD The Wet Chemical Fire Suppression System 3-22 Cylinder Sizing After finding how many nozzles of each type are required for a system, the sum of all the nozzle flow numbers is _ used to determine the number and size of the cylinders required, in accordance with the cylinder flow number limits given below. Table 3-3. Cylinder Flow Number Limits Maximum Flow Numbers of Cylinders Cylinder Flow Number RG-1.25G(4.7 L) 4 Single Cylinder Only (Cannot Manifold) RG 2 5G(9.5 L).. 8. Single Cylinder only PLC,anR(not Manifold} RG-4GT or RG-4GS (15 L)(Long or Short 1 Cylinder 12 2 Cylinders 24 Can Manifold 3 Cylinders 36 Up to 4 Cylinders 4 Cylinders 48 1 Cylinders x; 18 Can Manifold 2 Cylinde! 36 Up to 2 Cylinders 'Only like cylinders can be manifolded (ie, four RG-4GS,two RG-6G.) The system can be actuated through various controls, in accordance with Table 3-4. To actuate a single cylinder system, use either the Mechanical or Electric Control Head or the A+ Control Box with pressure operated actuator. To actuate two or three cylinders, use either one or two Tandem Control Heads and a Mechanical or Electric Control Head or the A+ Control Box with 1-3 Pressure Operated Actuator(s). To actuate from 1 to 5 cylinders, the A+ Control Box with Pressure Operated Actuator(s) must be used. For applications requiring 5-10 cylinders the BMCS-1 nitrogen releasing system is recommended. Larger systems, 10-100 cylinders, the BMCS-7 nitrogen releasing system is the recommended means of cylinder actuation. For complete details of the BMCS-1 and BMCS- 7 systems, refer to each respective manuals, P/N B900002 and P/N B9000003. Table 3-4. Actuation Controls Mechanical or Electric Tandem A+Control System Size Control Head Control Head Box BMCS-1 BMCS-7 1 Cylinder ✓ ✓ ✓••_ 2 Cylinders ✓' ✓ ✓_•• 3 Cylinders ✓" ✓ ✓_•- 4 Cylinders ✓" ✓ ✓••_ 5 Cylinders ✓— ✓ ✓••• 5-10 Cylinders ✓" ✓~• 10+ Cylinders ✓" ✓••• ✓••• ' Requires both a mechanical or electric control head and tandem control head " Requires a mechanical or electric control head and multiple tandem control heads *"BMCS series requires a mechnical or electric control head to actuate. The Wet Chemical Fire Su ressiort System Y stem 3-21 Nozzle Summary Table 3-2. Nozzle Summary Perimeter Diameter Nozzle iHazard Max. Max. Length Flow No. Duct 50"(165.1 cm.) 15.25"(39 cm) Unlimited. ADP/1 HazardLength Width Nozzle Max. Max. Filters Flow No. Plenum 10'(3.0 m) 4'(1.2 m) "V"Bank or Single ADP/1 Hazard Size Nozzle Height Notes Nozzle/ Hazard Inches/cm Inches/cm Inches/cm Flow Four-Burner Range 28 X 28(71 x 71) 20 to 42(52 to107) within 9(23)rad. _ _ q of mid point. RR11 Single Vat Deep Fat Fryer(Drip Boards 1 to 6[2.5 toll 8n 18 X 18(46 x 46) 27 to 45(6999,toll 14) y45°to 901 ?ejL F/2 a .... ..0 kM�w[ � Y.FTs;:i�. 4�.'•�"��"� .e..yam:. Split Vat Deep Fat Fryer 14 x 15(36 x 38) 27(69)to 45(117) 45.to 90' F/2 A F . Woks 14 to 28(36 to 71)Dia. within 2(5) 3 to 8(8 to 20)Deep 35 to 56(89 to 142) of mid point. GRW/1 Closed Top Chain Broilers 28 X 29(71 x 74) See3-12 See3-12 ADP/1 O'p—MopC an'lot ers .. ._ , Pumice Rock(Lava,Ceramic)Charbroiler 22 X 23(56 x 58) 24(61)to 48(122) 45°to 90% 2 Layers of rock F/2 Nat �' SS C�iar oaCha Yo.e 24 X 24 (61 61)z4 6 too C•� s .a" Electric Charbroiler(Open Grid) 24 X 21 (61 x 53) 24(61)to 48(122) 45"to 90° GRW/1 ss'T - - '� - rsta.i.i- - t ,. ''`",,•.+-xsa:�.t�t�a. :S�f7`l0 rr::_.r��+.: Mesquite Charbroiler(Chips,Wood,Logs) 30 X 24(76 x 61) 24(61)to 48(122) 45'to 90% 10(25)Fuel depth DM/3 d5q it.-Fia pfC toiler '; � 30h '" " 1 to!:$:7 Tilt Skillet and Braising Pan 24 x 24(61 x 61) 27.5 in(70 cm)to 46 in(117 cm) within perimeter F 12 ozzle Nozzle Part Identification No. Flow No. ADP(Appliance-Duct-Plenum) C12OO11 1 GRW(Gas Radiant-Wok) C12OO13 1 DM(Mesquite) C12OO15 3 Wet Chemical Instruction Manual AD-2 Designing for Plenum Protection A single ADP nozzle(P/N B120011)will protect a located at one end of the plenum.Longer plenums may single filter or'V'filter bank plenum with the following be similarly protected with a single ADP nozzle being maximum dimensions: used for each 10 ft. (3.0 m)of plenum length and each 4 ft. (1.2 m) of plenum width- Plenum Length I O Feet j3.O m) ADP nozzles may be used in combinations(see Plenum Width 4 Feet(I.2 m) Figure AD-2).Multiples may be installed facing in the When no filters are present, the nozzle protecting same direction, and/or at the ends of the plenum the plenum is used to discharge the wet chemical on pointing in. Each nozzle shall provide a maximum of the underside of the hood. In this case. the hood may 10 feet of coverage, not exceed a length of 10 ft_ (3.0 m) or a width of 4 ft. ADP nozzles must be centrally located in the plenum (1.2 in). with their discharge directed along the length of the A plenum with either a single filter bank or'V" filter plenum and located in relation to the filters as shown bank and a length of 10 ft. (3.0 m)or less may be in Figure AD-2, protected by one ADP nozzle- The nozzle shall be Note: All Range Guard systems are listed by UL for use with the exhaust fan either on or off when the system is discharged. lF-10 FEET -> � I 1� 4 FT.(1.2 M)PLENUM R WIDTH NOZZLE LOCATED AT EITHER END `Z 10 FT.(3.0 M)PLENUM LENGTH OF PLENUM LENGTH AIMED DOWN LENGTH OF PLENUM r ADP NOZZLE FILTERS 1 FLOW NUMBER r- 20 FEET -> jt-20 FEET --o f 10 10 E 10 ` 10 j i I 4FT 4 FT. 1 �►j 20 FT_ r 20 FT. r �1 70��1 ADP NOZZL ADP NOZZLES ACCEPTABLE NOZZLE POSITIONS FOR MULTIPLE NOZZLES ADP i 113 Wir NOZZLES 1 '/a H '� Ha -. — H t — �- H -t zA J "V"FILTER BANK 1�W COVERAGE SINGLE BANK FILTER COVERAGE Figure AD-2. Plenum Protection Nozzle P/N B120011 Wet Chemical Instruction Manual AD-5 Designing for Larger Duct Protection Ducts 50 to 100 inches in perimeter: Two ADP nozzles, P/N B120011, pointing in the same Note: All Range Guard systems are listed by UL for direction are required for protection of ducts with use with the exhaust fan either on or off when perimeters greater than 50 inches and less than or the system Is discharged. equal to 100 inches. Ducts can be of unlimited length (See Figure AD-5). For other option of ducts up to 75 perimeter inches (See Figure AD-7 on page AD1-9. DUCT HOOD x Y=�� �y 2�y Y<d '/d ,/�/�. � � z Maximum Diameter: 31.83 inches ••-s %A /N HHc-� NOZZLES TO BE ALONG ONE t ` C + ` + CENTERLINE AT THE%POINTS. NOZZLES TO BE 0"TO 6"UP FROM ENTRANCE OF VERTICAL DUCT Maximum Diagonal: 11.78 inches Maximum Diagonal: TYR(2)ADP NOZZLES, 11.78 inches B120011 SQUARE RECTANGULAR ROUND ADP NOZZLE t DUCT ENTRANCE OF VERTICAL DUCT --L - qLAIM OF HORIZONTAL DUCT w2 to 4 inches ADP NOZZLE POINT nozzle tip to duct hip �, VERTICAL/HORIZONTAL DUCT Figure AD-5. Duct Protection Using Two ADP Nozzles, P/N B120011 The Wet Chemical Fire Suppression System ftA a V AN F NOZZLE MAY BE LOCATED 3-5 Deep Vat Fryer and Griddle ANYWHERE WITHIN THE GRID 45"(114 cm) SINGLE VAT DEEP FAT FRYER WITH DRIP MAX DIAGONAL FROM BOARDS AIM POINT One F nozzle or Plenum nozzle will protect one 45"(114 cm) 45"(114 cm) Single Vat Deep Fat Fryer with a maximum hazard MAX MAX area of 18"x 18"(46 cm x 46 cm) and an appliance area 18"x 23" (46 cm x 58 cm) for fryers with a drip board. The nozzle is located at an angle of 45 degrees or more from the horizontal. It shall not be more than MIDPOINT OF 45" 014 cm) nor less than 27"(69 cm)from the top of HAZARD AREA the appliance and aimed at the midpoint of the hazard area. The nozzle can be outside the perimeter of the 18" appliance. (Hazard Area 18"x 18" (46 cm x 46 cm) - (46 cm) rr , \ 23" See Figure 3-7) MAX �� 4 I u ' ati��i� (58 cm) DRIP BOARD 18"(46 cm) I ♦ MAX. 48' Figure 3-7. Single Vat Deep Fat Fryer 122cm) Max GRIDDLE-FLAT COOKING SURFACE One ADP nozzle will protect one griddle (with or without raised ribs)with a maximum hazard area of 30"x 42"(76 cm x 107 cm).The nozzle is located at 3tr t any point on the perimeter of the appliance and (7 M ) 13• aimed at a point 3" (7.6 cm)from the midpoint of the AX (3M3 r. hazard area. It shall not be more than 48"(122 cm) j Top of Appliance nor less than 13" (33 cm) above the edge of the appli- ance perimeter. Positioning the nozzle directly over 1r ,r MAX AIM PT.-3'Radfus from the ♦—(107cm)MAK- 10- Mldpofntof Huard Area the appliance is not acceptable. (See figure 3-8.) Figure 3-8. Griddle-Flat Cooking Surface AN F OR PLENUM NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45" MAX DIAGONAL FROM SPLIT VAT DEEP FAT FRYER AIM POINT One F nozzle or Plenum nozzle will protect a Split 45" 45" Vat Dee Fat Fryer with a split vat hazard area maxi- (MAX., (114 cm) P rY P Mx" MAX., mum of 14"x 15" (36 cm x 38 cm)without drip board and 14"x 2 1" (36 cm x 53 cm)with a drip board. The nozzle is located at an angle of 45 degrees or more AIM POINT- from the horizontal. It shall not be more than 45" MIDPOINT OF HAZARD (114 cm) nor less than 27"(69 cm)from the top of the CENTERED ON DIVIDER appliance and aimed at the midpoint of the hazard 27"(69 cm MIN area. The nozzle can be outside the perimeter of the ,, � appliance. (Hazard Area 14"x 15" (36 cm x 38 cm) - (38 cm) 21"(114 cm) INTERIOR See figure 3-9) MAX OVERALL DRIP BOARD I� 14"(36 MAX"., Figure 3-9. Split Vat Deep Fat Fryer U.L.I. Ex 2458 3-5 Manual Part No.9127100(9/97)Badger Fire Protection The Wet Chemical Fire Suppression System RAM `'UM 3-13 Range RANGE One'R'nozzle will protect one four burner range with a maximum hazard area of 28"x 28"(71 cm x 71 cm). The nozzle is to be located directly over the midpoint of the hazard area and anywhere within the area of a circle generated by a 9"(23 cm) radius about the midpoint. The nozzle shall not be more than 42"(107 cm) nor less than 20" (51 cm) from the midpoint of the hazard area,aimed at the midpoint. (See figure 3-25) NOTE: SHAPE OF BURNER NOT IMPORTANT 18"(46 cm)DIX —42"(107 cm)MAX. (From Top of Range Surface) I I A'R'NOZZLE MAYBE LOCATED ANYWHERE WITHIN THE SHADED AREA. 20"(51 cm)MIN. AIM PT.- MIDPOINT m(Fro Top of OF HAZARD AREA Range Si 28"(71cm) MAX. AIM POINT HAZARD AREA - 14"(36 cm) MAX. BURNER LENGTH CENTERLINE TO CENTERLINE 14"(36 cm) MAX. BURNER CENTERLINE TO CENTERLINE 28"(71 cm)MAX. HAZARD AREA WIDTH Figure 3-26.Two Burner Aim Point Center of Hazard Figure 3-25. Four Burner Range 18"(46 cm)DIA. 4 —42"(107)MAX. SINGLE BURNER RANGE )' A`R'NOZZLE MAYBE LOCATED ANYWHERE Special care is to be taken when aiming the'IV WITHIN THE SHADED AREA. nozzle over a single burner range. The aiming point is to be located 7" (18 cm) from the center of the burner. The nozzle placement shall fall within a cylindrical T, AIM PT. area generated by a 9"(23 cm)radius about the aiming point. The nozzle must be placed no more than 42" 007 cm) nor less than 20"(51 cm) above the hazard 20"(51cm) MIN area. (See figure 3-27) 7"(18 cm)FROM BURNER CENTERLINE TO AIM # POINT CENTERLINE Figure 3-27. Single Burner Range UPON ACTIVATION OF SYSTEM, EXHAUST FAN SHALL REMAIN OPERATING AND MAKE-UP AIR SHALL SHUT OFFj ALL FUEL AIgA PtqWER UNDER HOOD TO SHUT DOWN 4 DETECTION WITH 450°F FUSIBLE LINK "CIO O C & EMT C� LL 12' HOOD ' BLACK PIPE n- _j ui 18 'X►g ' DUCT 'Q o RANGE GUARD - -- - Q — - - - - - - - - - 1 ETGSYSOTEM 300 MAKE UP AIR C%V-L„ X I MANUAL PULL C STATIO T. 3 t GAS C VALVE HIJ FIRE & SAFETY HIJFISN988KO (206) 353-9123 ( TOTAL TWO FLOW POINT PLENUM, TWO ADP NOZZLE RANGE GUARD O TOTAL TWO FLOW POINT DUCT, TWO ADP NOZZLE FIRE SUPPRESSION SYSTEM Q3 omo: TZ0lJ 14;'OIA17- STCJCk T 0.4F R %• = 1'0• r SCALE' APPROVED BY, DRAVN Hri HIJ ® TWO + Ou/ �i�'/T 'Qu�i i'�. 7Z!/'O R A10ZoL� DATE, 3-25-08 JAMES HWANG SCPH-00798 REVISED 5 7vo Tz&) 1,1T TA(sk. avl_z /4- /"x,) �:/.e- HmpESS NAME, HUSDESS LOCATION � 9a Nwy L� GALLON FLOW POINTS, TOTAL /0 FLOW POINTS USED AM G�0 The Wet Chemical Fire Suppression System -22 Cylinder Sizing 3 y g After finding how many nozzles of each type are required for a system, the sum of all the nozzle flow numbers is used to determine the number and size of the cylinders required, in accordance with the cylinder flow number limits given below. Table 3-3. Cylinder Flow Number Limits . Maximum Flow Numbers of Cylinders Cylinder .- RG-1.25G(4.7 L) 4. Single Cylinder Only (Cannot Manifold) RG-2 5G(9.5 Lj 8 " Single Cylinder Only (Cannot Manifold) RG-4GT or RG-4GS (15 L)(Long or Short 1 Cylinder 12 2 Cylinders 24 Can Manifold* 3 Cylinders 36 Up to 4 Cylinders 4 Cylinders 48 RG-6,Cx(22.7 L) 1 Cylinder 18 Can Manifold 2 Cylinders 36 Up to 2 Cylinders 'Only like cylinders can be manifolded(ie, four RG-4GS,two RG-6G.) The system can be actuated through various controls, in accordance with Table 3-4.To actuate a single cylinder system, u'§e either the Mechanical or Electric Control Head or the A+ Control Box with pressure operated actuator. To actuate two or three cylinders, use either one or two Tandem Control Heads and a Mechanical or Electric Control Head or the A+ Control Box with 1-3 Pressure Operated Actuator(s). To actuate from 1 to 5 cylinders, the A+ Control Box with Pressure Operated Actuator(s) must be used. For applications requiring 5-10 cylinders the BMCS-1 nitrogen releasing system is recommended. Larger systems, 10-100 cylinders, the BMCS-7 nitrogen releasing system is the recommended means of cylinder actuation. For complete details of the BMCS-1 and BMCS- 7 systems, refer to each respective manuals, P/N B900002 and P/N B9000003. Table 3-4. Actuation Controls Mechanical or Electric Tandem A+Control System Size Control Head Control Head Box BMCS-1 BMCS-7 1 Cylinder ./ ✓ ✓�" 2 Cylinders ✓' ✓ ✓'"i 3 Cylinders ✓" ✓ ✓#'� 4 Cylinders ✓`" ✓ ✓'" 5 Cylinders ✓" ✓ ✓'�t 5-10 Cylinders ✓'" ✓��+ 10+Cylinders ✓" ✓�'i ✓*�� * Requires both a mechanical or electric control head and tandem control head ** Requires a mechanical or electric control head and multiple tandem control heads *"BMCS series requires a mechnical or electric control head to actuate. U.L.I.Ex 2458 3.22 Manual Part No.9127100(9/97)Badger Fire Protection The Wet Chemical'Fire Suppressiort System RAM `' 3-21 Nozzle Summary Table 3-2. Nozzle Summary Perimeter Diameter Nozzle Hazard Max. Max. Length Flow No. Duct 50"(165.1 cm) 15.25"(39 cm) Unlimited. ADP/1 e Length Hazard Max. Max. Filters Flow No. Plenum 10'(3.0 m) 4'(1.2 m) "V"Bank or Single ADP/1 Hazard Size Nozzle Height Notes Nozzle/ 'Hazard Inches/cm Inches/cm Inches/cm Flow Four-Burner Range 28 X 28(71 x 71) 20 to 42(52 to107) within 9(23)rad. of mid point. R/1 t ookit? �r OEM 10 F F (1OZx6R., j too _ Single Vat Deep Fat Fryer(Drip Boards 1 to 6[2.5 to18n 18 X 18(46 x 46) 27 to 45(69to114) 45'to 90' F/2 Split Vat Deep Fat Fryer 14 x 15(36 x 38) 27(69)to 45(117) 45'to 90' F/2 3 8 h d1 7 GSi,w: fle • .v � , 3 ��3 �• Deus �� .• n Woks 14 to 28(36 to 71)Dia. within 2(5) 3 to 8(8 to 20)Deep 35 to 56(89 to 142) of mid point. GRW/1 Upg't' orb`6Ii: ..5:9 ••Y.SY:rFS:. '..j... ..-S-,-r`6`t'�.' '..t�n..::�'iC • .rS.:d i:.u-, '.$ FY.c° femai Af1m [ Closed Top Chain Broilers 28 X 29(71 x 74) See3-12 See3-12 ADP/1 I' e�' ••r� n� �.»z L"S�.i u t > .f;oc4��. k �e+'u as ._, �.n,:3,4. at.,..: Pumice Rock(Lava,Ceramic)Charbroiler 22 X 23(56 x 58) 24(61)to 48(122) 45`to 90°; Ei 2 Layers of rock F/2 a coafR 4-X 6 : fi t F' t Electric Charbroiler(Open Grid) 24 X 21 (61 x 53) 24(61)to 48(122) 45°to 90° GRW/1 GazRadiahG ai roiled �� "w • , .�, 6`r v5-3 . yy1, ° (P` `' y. .,,mus.a�_...-� ; �Ay..mx��•-�, �sxf.�2s�� k� z kZ � 22 � �Z` '�% p. Mesquite Charbroiler(Chips,Wood,Logs) 30 X 24(76 x 61) 24(61)to 48(122) 45'to 90'; 10(25)Fuel depth DM/3 a -�uT arco 1� t ile �� 30 r 7� 1 4, , 1 � nr a ;t �4 6O Tilt Skillet and Braising Pan 24 x 24(61 x 61) 27.5 in(70 cm)to 46 in(117 cm) within perimeter F/2 Nozzle Nozzle Part Identification • - ADP(Appliance-Duct-Plenum) C12OO11 1 lit��+^nrs-���•�7�r-- Y�^s� � ZQO 2 ' GRW(Gas Radiant-Wok) C12nnOnO��1,3 1 DM(Mesquite) C12OO15 3 Wet Chemical Instruction Manual AD-2 Designing for Plenum Protection A single ADP nozzle ON B120011)will protect a located at one end of the plenum. Longer plenums may single filter or'V'filter bank plenum with the following be similarly protected with a single ADP nozzle being maximum dimensions: used for each 10 ft. (3.0 m) of plenum length and each Plenum Length 10 Feet(3.0 m) 4 ft. (1.2 m) of plenum width. Plenum Width 4 Feet(1.2 m) ADP nozzles may be used in combinations (see Figure AD-2). Multiples may be installed facing in the When no filters are present, the nozzle protecting same direction, and/or at the ends of the plenum the plenum is used to discharge the wet chemical on pointing in. Each nozzle shall provide a maximum of the underside of the hood. In this case, the hood may 10 feet of coverage. not exceed a length of 10 ft. (3.0 m) or a width of 4 ft. ADP nozzles must be centrally located in the plenum (1.2 m). with their discharge directed along the length of the A plenum with either a single filter bank or 'V' filter plenum and located in relation to the filters as shown bank and a length of 10 ft. (3.0 m) or less may be in Figure AD-2. protected by one ADP nozzle. The nozzle shall be Note: All Range Guard systems are listed by Ul-for use with the exhaust fan either on or off when the system is discharged. 10 FEET 4 FT.(1.2 M)PLENUM WIDTH j NOZZLE LOCATED AT EITHER END ��1 10 FT. (3.0 M)PLENUM LENGTH OF PLENUM LENGTH AIMED DOWN LENGTH OF PLENUM ADP NOZZLE 1 FLOW NUMBER FILTERS 20 FEET t -20 FEET 10 10 10 10 4 FT _I I I 20 FT. 20 FT. 10 AD ADP # NOZZLE NOZZLES ACCEPTABLE NOZZLE POSITIONS FOR MULTIPLE NOZZLES ADP 1!3 WIf NOZZLES I '/,H H H "V" FILTER BANK ��W -►� COVERAGE SINGLE BANK FILTER COVERAGE Figure AD-2. Plenum Protection Nozzle P/N 13120011 U.L.I. Ex 2458 ADi-4 December, 1997 Wet Chemical Instruction Manual AD-5 Designing for Larger Duct Protection Ducts 50 to 100 inches in perimeter: Two ADP nozzles, P/N B120011, pointing in the same Note: All Range Guard systems are listed by UL for direction are required for protection of ducts with use with the exhaust fan either on or off when perimeters greater than 50 inches and less than or the system Is discharged. equal to 100 inches. Ducts can be of unlimited length (See Figure AD-5). For other option of ducts up to 75 perimeter inches (See Figure AD-7 on page AD1-9. DUCT Y i:::::; HOOD x x --YX 1/4X y � 1/,d 1/2d Maximum Diameter: 31.83 inches /,x /zx NOZZLES TO BE ALONG ONE ` + + CENTERLINE AT THE''%POINTS. NOZZLES TO BE 0"TO 6"UP FROM ENTRANCE OF VERTICAL DUCT Maximum Diagonal: 11.78 inches Maximum Diagonal: TYR(2)ADP NOZZLES, 11.78 inches B120011 SQUARE RECTANGULAR ROUND ADP NOZZLE t DUCT ENTRANCE % OF VERTICAL DUCT --L- -- --- OF HORIZONTAL DUCT ' w� i i 2 to 4 inches ADP NOZZLE ' AIM POINT no tip to duct hip VERTICAL/HORIZONTAL DUCT Figure AD-5. Duct Protection Using Two ADP Nozzles, P/N B120011 U.L.I. Ex 2458 AD1-7 December, 1997 The Wet Chemical Fire Suppression System IWGE GtR AN F NOZZLE MAY BE LOCATED 3-5 Deep Vat Fryer and Griddle ANYWHERE WITHIN THE GRID 45"(114 cm) SINGLE VAT DEEP FAT FRYER WITH DRIP MAX DIAGONAL FROM BOARDS AIM POINT One F nozzle or Plenum nozzle will protect one 45"(114 cm) 45"(114 cm) Single Vat Deep Fat Fryer with a maximum hazard MAX MAX area of 18"x 18" (46 cm x 46 cm) and an appliance area 18"x 23" (46 cm x 58 cm) for fryers with a drip board. The nozzle is located at an angle of 45 degrees or more from the horizontal. It shall not be more than MIDPOINT OF 45" (114 cm) nor less than 27"(69 cm) from the top of HAZARD AREA the appliance and aimed at the midpoint of the hazard area. The nozzle can be outside the perimeter of the „ appliance. (Hazard Area 18"x 18" (46 cm x 46 cm) - 18" inl Ca� 23" See Figure 3-7) i) tG (58 cm) DRIP BOARD _ ~ 18"(46 cm) I — MAX. 48" Figure 3-7. Single Vat Deep Fat Fryer 122cm) Max GRIDDLE-FLAT COOKING SURFACE One ADP nozzle will protect one griddle (with or without raised ribs)with a maximum hazard area of =- 30"x 42" (76 cm x 107 cm). The nozzle is located at 30' 1 any point on the perimeter of the appliance and v6 G ) 13' aimed at a point 3" (7.6 cm)from the midpoint of the MAX (33cm) hazard area. It shall not be more than 48" (122 cm) Am1n Top of Appliance nor less than 13" (33 cm) above the edge of the appli- 47 MAX AIM PT,3"Radius from the ance perimeter. Positioning the nozzle directly over (♦--(107�) �4 Midpoint of Hazard Area the appliance is not acceptable. (See figure 3-8.) Figure 3-8. Griddle-Flat Cooking Surface AN F OR PLENUM NOZZLE MAY BE LOCATED ANYWHERE WITHIN THE GRID 45" MAX DIAGONAL FROM SPLIT VAT DEEP FAT FRYER AIM POINT One F nozzle or Plenum nozzle will protect a Split 45" 45" (114 cm) (114 cm) Vat Deep Fat Fryer with a split vat hazard area maxi- MAXI MAX" mum of 14"x 15" (36 cm x 38 cm)without drip board and 14"x 2 1"(36 cm x 53 cm)with a drip board. The nozzle is located at an angle of 45 degrees or more AIM POINT: from the horizontal. It shall not be more than 45" MIDPOINT OF HAZARD (114 cm) nor less than 27"(69 cm)from the top of the CENTERED ON DIVIDER appliance and aimed at the midpoint of the hazard 27"(69 cm MIN area. The nozzle can be outside the perimeter of the 15"38 c 114 cm) m) �` 21"( appliance. (Hazard Area 14"x 15" (36 cm x 38 cm) - (Mom„ INTERIOR See figure 3-9) 1 OVERALL DRIP BOARD I� 14"(36 cm) il— MAX" Figure 3-9. Split Vat Deep Fat Fryer U.L.I.Ex 2458 3-5 Manual Part No.9127100(9/97) Badger Fire Protection I The Wet Chemical Fire Suppression System R V 3-13 Range RANGE One 'R'nozzle will protect one four burner range with a maximum hazard area of 28"x 28" (71 cm x 71 cm). The nozzle is to be located directly over the midpoint of the hazard area and anywhere within the area of a circle generated by a 9" (23 cm) radius about the midpoint. The nozzle shall not be more than 42" (107 cm) nor less than 20" (51 cm) from the midpoint of the hazard area, aimed at the midpoint. (See figure 3-25) NOTE: SHAPE OF BURNER NOT IMPORTANT 18"(46 cm)DIA. —42"(107 cm)MAX. (From Top of Range Surface) A'R'NOZZLE MAYBE j LOCATED ANYWHERE WITHIN THE SHADED AREA. / 20"(51 cm)MIN AIM PT.- MIDPOINT (From Top of Range Surface) OF HAZARD AREA 28"(71cmtj AIM POINT HAZARD 14"(36 cm) MAX. BURNER LENGTH CENTERLINE TO CENTERLINE 14"(36 cm) MAX. BURNER CENTERLINE TO CENTERLINE WIDTH Figure 3-26.Two Burner Aim Point Center of Hazard Figure 3-25. Four Burner Range 18"(46 cm) DIA. 42"(107)MAX. X SINGLE BURNER RANGE A'R NOZZLE MAYBE " LOCATED ANYWHERE Special care is to be taken when aiming the 'R' WITHIN THE SHADED AREA. F nozzle over a single burner range. The aiming point is N.:' ���• to be located 7" (18 cm) from the center of the burner. ' The nozzle placement shall fall within a cylindrical P Y � <�<.;:rt<. :,.-. -AIM PT. area generated by a 9" (23 cm) radius about the aiming point. The nozzle must be placed no more than 42" (107 cm) nor less than 20" (51 cm) above the hazard 20"(51cm) MIN area. (See figure 3-27) 7" (18 cm)FROM BURNER CENTERLINE TO AIM POINT CENTERLINE Figure 3-27. Single Burner Range U.L.I.Ex 2458 3-13 Manual Part Nn P1971no!R/A71 Rarin-r Fir-Prnt-ntinn MASON CClu"i'lITY F--!:- 0 p'F,* DATE-:!-- (S�-6)6 I ALL APPLICARL CODES SHALL APPLY. r.;;tIr)nC, AND/OR OvISSIONS ON. P!-ANS ARF Sr!.F w-'(:- SPCMV01.'.ITY OF C,,)rqf-,C- TICNS P,EOUj.'ED FRO!.4 vll:t.r, 111SPECT-ON qWLL CE AT OtVNr--R/CONTRii,GTOP':; ZX Ei' THI$ PROVAL DOES �.!�OT U11ANT TO ANY t :RSO;4 tr,F RIGHT TO VIOLATE ANY CtT'f OR SIAT,-