Loading...
HomeMy WebLinkAboutCOM Plot / Site Plans - 6/25/2014 i OWNER v > LONNIE F055 cl 196bci 7th AVE NE POUL5BO, WA Q5370 o PHONE: 360-265-3432 m 241' AGENT/AFFL I CANT Tllul KARL DJORDJEVIC tu I PO BOX 1761 t � ' Y S I LVERDALE, WA 15555 �-�-1 = ' PHONE: 360-340-2025 o d i 51TE ADDRE55 a . 2020 NE OLD BELFAIR HWY O d r BELFAIR, WA 1 i BLDG ADDRE55 FIRE ACCESS GATE WILL NOT BE LOCKED = Ici86 NE OLD BELFAIR HAT' BELFAIR, WA 20' FIRE LANE EX 15TI NG ASPHALT z PARCEL NUMBER � I23I�-41-00050 (q) OARS O Y cl,x2g sP NCEE O dz ��� TURN-ABOUT AS PER w a�K � �y TITLE 14, MASON GNTY G pC i C BLDG GODS JGOI—L Cr a , FIRE LANE LINE TO n BE DELINEATED BY TO CONVERT A (1) STORY, WOOD TRU55 MANUFACTURING POLE a FROJEGT RED PAINT BARN INTO A (2) STORY, ENCLOSED GANIBUS5 PRODUCTION 4 BU I LD I NCB PROCESSING FACILITY. 103' H v �o o DE516N DATA: o • � MAIN ACCESS GRAVEL CODE 2012 IBC a 9ro lab' TYFE GONST. 1\/ qn OGG. GROUP U E-I * �E'; o - Rs tin OGGUFANGY 53 4 8Hg u FLOOR AREA 10/414 50. FT. 527 50. FT. gffi FIRST FLOOR 5544 5Q. ET. m PLANNING: g SECOND FLOOR 4150 5Q. ET. Hig t ALL SETBACKS ARE MEASURED N�� Ila Is " V i FROM THE FURTHEST HEIGHT TWO STORY NOTE: KNOX-BOX ON FIRE ACCESS GATE . IS NOT REQUIRED IF GATE 15 LEFT UNLOCKED P BUILDING--, OF THE BUILDIN - — - - ZONING R1 tu gPPROVED N MASON COUNTY DCD PLANNING NOTE: TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS : <j- FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES SITE NGEEJ SUBjE T TO BE ON SITE dj BETWEEN FIRE AREAS - 000 GROUP U = (1) HR FIRE RATING. 0 CHANGc.S SU3JEC i TO APPROVAL � - � � gY Date ( � — < 111 lQ a DRAW I NG I NDr=X REVISIONS SHEET NO. DESCRIPTION I SITE PLAN, NOTES, DESIGN DATA 2 FIRST FLOOR PLAN, WALL TYPE 3 SECOND FLOOR PLAN, DOOR SCHEDULE I 4 CRO55ECTION, STAIR SEC. 436' 5 EXTERIOR ELEVATIONS 6 i 51TE PLAN ill 1" = 50'-0" Lu _ N RESTROOM GALL OCCUPANT LOAD NET AREA USE SQUARE FOOTAGE FACTOR FROM TABLL 1004.1.2 OCCUPANT LOAD C, GENERAL NOTES USE GROUP 5 U I. NOTIFY DE5IGNER/ARCHITEGT/ENGINEER IF 51TE FIRE ALARM REQUIREMENT PLUMBING, FIXTURE GALL-- OGG &ROUP U (5) 4526 SF GROW AREA Ist FLR 4526 5F 300 GR055 15 N CONDITIONS AND/OR BUILDING DEPT. REQUIRE ANY WASHINGTON STATE AMENDMENTS - 2012 IFG WASHINGTON STATE AMENDMENTS GHPT 2q 2ci6 DRY ROOM 2CI6 300 6RO55 I MODIFICATIONS TO THESE PLANS PRIOR TO TOTAL NET FLOOR AREA = 10,561 5F COMMENCING WORK. 61 QUARANTINE 61 500 GRO55 I U OCCUPANCY - EXEMPT IN PARAGRAPH 1103 $ 907 2. CONTRACTOR TO CHECK L VERIFY ALL DIMENSIONS #2CIO1.2 MIN. REQUIREMENTS. ...ONE OCCUPANT BEFORE CONSTRUCTION. F-I OCCUPANCY - NOT REQUIRED BELOW (2) STORIES. PER UNIT OF NET FLOOR AREA AS PER TABLE 2`102.1 505 PRIOCE551NG 305 200 GR055 2 PARAGRAPH C107.2.4 4 1103.7 FOR GROUP 5 I: 1-10 MALE I: 1-10 FEMALE S. MUST MEET OR EXCEED 2012 VENTILATION 4 ENERGY FIRE EXTINGUISHERS FOR U 000 - NOT REQUIRED USE 5000 SF PER OGG. FOR THE MIN # OF FIXTURES. 5373 GROW AREA 2nd FLR I�i66 300 GR055 7 CODES. PARAGRAPH g0(o.1. REQUIRED IN F-I - I PER 1000 SF WITHIN 30 FT OF GOOK TOP. 2C102.1.2 OCCUPANCY LOAD DISTRIBUTION. THE OGG 2nd FLR - FUTURE EXPANSION 3407 300 GR055 II LOAD SHALL BE DIVIDED EQUALLY BETWEEN SEXES. FUTURE PERMIT N0TE5 GOOK HOOD - PARAGRAPH 60C1.2. THE HOOD WILL NOT BE RECEIVING GREASE VAPORS, ONLY WATER. TYPE 2 10,561/5000 = 2.1 HOOD TO BE INSTALLED. ENTIRE U OCCUPANCY 34 I. PROVIDE (2) 2A 205G FIRE EXINGUISHER5 TO BE MOUNTED 10,561 SF TOTAL OGG LOAD LESS ACCESSORY NEAR THE EXIT DOORS IN CLEAR VIEW $ REACH ILLUMINATED EXIT SIGNS TO HAVE BATTERY BACKUP. SEC. 2903.1: SEPARATE TOILET FACILITIES SHALL BE PROVIDED 2. PROVIDE A 516N ABOVE FRONT MAIN EXIT TO SAY FOR EACH SEX. 37 J� TOTAL OGG LOAD PLUS ACCESSORY "THIS DOOR TO REMAIN UNLOCKED DURING BUSINES HOURS" EXCEPTION: IN OGG 5ERVIN6 15 OR FEWER PERSONS, ONE (s) _ TOILET FAG I L I TY DE51 GNED FOR USE BY NO MORE THAN ONE PERSON AT A TIME SHALL BE PERMITTED FOR USE BY BOTH SEXES. DENOTES ACCESSORY