Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MIS94-1110 Lower Floor of Church - MIS Permit / Conditions - 8/19/1994
CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date _ -Z 3 - 5 y lam, date by date by PLUMBING OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by Page No. 1 CASE HISTORY FOR CASE NO.: BLD94-1110 PRINCE OF PEACE CATHOLIC CHRC NE1171 SAND HILL RD BELFAIR 02/02/95 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By ------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- --- BLDA010 Application received / / / / 07/26/94 07/26/94 KW BLDA100 Approved For Issuance / / / / 08/17/94 DONE KS 08/17/94 KS BLDA500 (F) Issue building permit / / / / 08/17/94 DONE KS 08/17/94 KS BLDA600 File Possession / / / / 09/17/94 SENT TO BELFAIR TO BE ISSUED. KS 08/17/94 KS BLDB009 Fire Marshal Review 10/13/94 / / 10/24/94 COMMENTS ARE INCLUDED ON MEMO ATTACHED DONE DLS 10/24/94 DLS TO APPROVED BUILDING PLANS. BLDB110 Structural Plan Review 08/02/94 / / 08/10/94 DONE WLC 08/10/94 WLC BLDB110 Structural Plan Review 10/13/94 / / 10/13/94 going to frame all interior walls know. DONE WLC 10/13/94 TDH BLDB120 WSEC Compliance Review 08/10/94 / / 08/16/94 originally reviewed 10,000 feetwhich DONE DC 08/17/94 DLC included the basement - all is ok! BLDB130 Planning Review 07/26/94 / / 08/02/94 DONE JEM 08/02/94 JEM BLDB134 RLC Checklist Review / / / / / / 07/26/94 KW BLDB135 Addressing / / / / 07/29/94 DONE GMM 07/29/94 GMM BLDC125 Framing inspection 01/19/95 01/20/95 01/20/95 NO APPROVED PLANS ON SITE. FAIL LW 01/23/95 LAW BLDC125 Framing inspection 01/19/95 01/20/95 01/20/95 DONE LW 01/23/95 LAW BLDC150 Wallboard inspection 01/30/95 01/31/95 01/31/95 PENDING MORE INFORMATION, PLANS UN-CLEAR PEND LW 02/02/95 LAW IF CORRIDOR NEEDS TO BE RATED OR NOT. BLDC150 Wallboard inspection 02/01/95 02/01/95 02/01/95 I SPOKE WITH WARREN C., HE STATED THE FAIL LW 02/02/95 LAW PLANS HAD AN ATTACHMENT THAT SHOWS THE CORRIDOR AS BEING RATED. CORRECTIONS: 1. PLASTIC PIPE CAN NOT PENETRATE THE CEILING OF THE CORRIDOR, ALSO SHEETROCK OVER 2X6 BLOCKS USED AS HANGS FOR PIPES. 2. FIRE DAMPERS NOT IN PLACE, DAMPER SLEEVES NEED TO BE ANCHORED TO FRAMING NOT JUST SHEETROCK. MASON COUNTY Mason County Bldg. 111 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 pt lAnn At r-qo1r -d I "n i I - 1 -0 "4 arp No! "t) n ) 10 , Apr! "-Al Hit 1 14" 1 5, qva" i -d I I f YN In- Am"lAt " I. JA0 . 00 h-"r t m i 0 1 midi! I h-"rl " M h, on % .. ... ., I It I !lot mp"t • hot "" AI 'mi "t; i 'it,f�, , 61111DIN6 16M , bi C I I ON '04 ( 1 ) "NH "I I I I "" 4 1 Al I I: HAVF APPkQVfD NURRI- kA OR 6D0RFSQ % VROVIIII'll IN 41I1 " A PONIVION A4 10 RV VIAJNlY Vl lhl ! ANO IFIVIVIV FRON ME SIRFET OR NUAD 1-PONI16 l "f PROPFPIY N6MON VO"NfY H" IIDINli DEPARIMIN ! PFA" IREK 71HAI IHIS Hf CONPIFIED PAIDW In VA11106 ! OR ANY 411V I.N41VIC111rNs PI- Itl';i`% I i f ON M . RAW ON RMS IN IARIF 1A OF IHr 14- 1 ONJU"PM H" 111 IM6 Coon Will HI ANSI` n flt ; V OUMMI "OlvaVIOR VAkI5 10 PO% I AUDRFAS ON " m pkl "R 1`0 1NqPFV11ON', At I mll` t mt i VO K I I m At mj: c he Nq , Pplvqd b" Iand W ldi "l o-I plow ' An ! i I of 1 mp I �v h- 1 q i r1 , "it I I I i il i (I�'e I i 1. o 144 1 vw"I lol- tu" 000l Alt r"Aw , the UnLform HlAildinq ( ado amd/m ma""" v I —;N I bo 6ppt "-wd by mak"" vo""Iv Prim i " "P . l I "i V, IoNnIp"V11ON vp"Cf4s 10 HF till " COMM tt " m" OF On I Ili I. -f "" Of- VARIMNI ANO HNJIOPM kffliOINK 1 001 L/ f WAUMTtu MASON COUNTY AUG 19 1994 f Ai-_r Mason County Bldg. III 426 W. Cedar GENERAL SERVICES. P.O. Box 186 Shelton, Washington 98584 .. "7" n„a .....�: `> %0„nr,n NE 1171 SAND HILL 01-JIVER : PRINCE Or PEACE Cf:712�01.TC CHPC LEGAL : TR i OF 'URV IG115 [5 3S141:A �TYP'_ A13U\' Cy C:1TE ,;� „ , ,�- il' C T'i'P r 0 E USE )CCl1P . GROUP . . C:. _ ;• _ ; 58.08 KS `; Y P C 0E CONST . ;'_ 39.3t KS ; Jr_!. L _ UNIT .. r ; 7N7,PECTTON AREA, ? ^;i I "! -,:- � a,;A � : ^TA: . ..3.SZ .. _I'll:A'„ti, CI -__ _ , _. TOT Lt_1"., I T',. , _ , . .,•., ., ••_ FRONT. . . ? 0 . 0ft BATH SASINc' 0 f? 1P 0 REAR . . . . Q" I, Y, `;ATH TIIP. S10E ( 1) . ? 0 . 0 t `',I10t"I R 0 r !.Ii'N 1001: RF 1 ' TCE ( ') . . Si1.. ._1NE . ' 0 o) I. .. LOT SI 'E . . . E3UIll3ING . . . . BASEMENT . . . . 0.,f CAR/CARP . :' 0� D1 1000G1 r, T r "R0 ACT OESCP,IPTION:TO CCMP:E71 I 'WE 7,"C? Sr PROJECT LOCATIOM:FROM BELFAIR LE'T 3H NORTHSHCRE .fC,",", 3'^r', 31 ..'.:iDi!Tl: RCA' . AS'. EI,'L i1 YTAP THIS PERMIT BECOMES MU!l AND VOIO T:F WCRK OR CONSTR!!C'I^'i rI'TUM"T'[C 'c k^,' r^XMrNC'S :T" 1 13P OF 181 DAYS AT ANY TIME AFTER WORK IS CCMMENCED. EVIOENCE OF CONTINUA'ION OF WORK IS A PP,3GRESS INS E'. T"I W"•'+'.N T''.' APPROVED BEFORE BUILDING "NI, CE CCC2"IED. OWNER OR AnEM': 0 -T[ EL PRMT, , . . . O3�'.' C Oi":' T gNCF Tr 117TAC T Permit No. MASON COUNTY BUILDING PERMIT APPLICATION 426 W. Cedar/P.O. Box 186, Shelton, WA 98584 427-9670/1-800-562-5628 PLEASE PRINT #1 Owner Pat NEE OC 004C 4fAT140u4- C Phone# z75,13 760 dress Q �1 ��'10 < <4• Fire District# Z $� St WA Zip $� Directions to Job Site -9&CA-12- i.. Ot4 14047 1r S Owner Mailing Address 4''I`rC 1061 34SE04 le "rks V V G t City 6 ctrx e- St VVA Zip BISZ40 Lien/Title Holder Address City St Zip #2 Contractor Name Contractor Reg# Address Expiration Date City St Zip Phone# #3 If septic is located on project site, include records. Connect to Septic?_ Public Water Supply Well Connect to Sewer System? Name of System (If residential, proof of potable water is required) StP'(te, 5`1ST4vK AloV PorAt(4-. WA-rdt PO&V 10 uscy APP Ral VA) #4 OTLe ascription 4t $COG Q�iLyV14� �- 104� #5 Building Square Footage: (existing/proposed) 1st FI / 2nd FI / 3rd FI / Loft / Basement 440 / Deck / #bedrooms / #bathrooms / Garage / Carport / (Circle: Attached or Detached?) Other sq. ft. / #6 Use of building �I�VitGZ-�— T1+tS 14 TO G'OtMP u��Descnb`woorrk �`0 #7 Type of Job: New Add Alt Repair Other #8 MOBILE/MANUFACTURED HOME INFORMATION Model Year Make Model Length Width Serial No. #Bedrooms # Bathrooms Type of Heat Purchase Price $ #9 Indicate by circling the applicable source if any water is on or adjacent to subject property: River Pond Creek Stream Wetland Lake Marsh Saltwater Seasonal Runoff Other Show following on the site plan Lot Dimensions Flood Zones Existing Structures Fences Structure Setbacks Driveways Water Lines Shorelines Drainage Plan Topography Septic Systems Wells Proposed Improvements Easements Name of Flanking Street Indicate Directional by (N, S, E, W) in relation to plot plan Name of Fronting Street APPLICANT TO DRAW SITE PLAN BELOW N W o S �c Ay P�e10tt Ko744L Lq UJC16L u� 9oa ► CIO APPLICANT TO DRAW TOPOGRAPHY PROFILE BELOW Plumbing Fixtures ($3$3 eachl Fee Mechanical Fixtures ($6 each) P Movit-i t µSTA4w No. ZToilets CIRCLE FUEL TYPE: Gas, Electric, —Bath Basins Heatpump, Other Bath Tubs No. Units Fees —Showers Furn BTU c � Hot Water Htr 7 _ Heatpumps _Laundry Washer _ Vent Systems 3 Sinks Spot Vent Fans l —Floor Drains No. Boilers/Compressors _Laundry Basins HP mac=. l Dishwasher No.. Air Handling Units Disposal — cfm# %Urinals CIO 00 No. Fire Protection Systems —Other Auto. Fire Alarm Sys 50.00 Fixed Fire Supp. Sys 50.00 Permit Basic Fee 15.00 Auto Fire Sprink Sys 25.00 00 — TOTAL PLUMBING No. Other Gas Outlets Wood, Gas, Pellet Stove NOTICE: THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COM- MENCED WITHIN 180 DAYS OR IF CONSTRUCTION OR Permit Basic Fee 15.00 WORK IS SUSPENDED OR ABANDONED FOR A PERIOD TOTAL MECHANICAL $� OF 180 DAYS AT ANY TIME AFTER WORK IS COM- MENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIRE- I CERTIFY THAT I AM A CURRENTLY REGISTERED MENTS OF THE CONTRACTORS REGISTRATION LAW CONTRACTOR IN THE STATE OF WASHINGTON AND I RCW 18.27, AND AM AWARE OF THE MASON COUNTY AM AWARE OF THE ORDINANCE REQUIREMENTS REGU- ORDINANCE REQUIREMENTS FOR WHICH THIS PER- LATING THE WORK FOR WHICH THE PERMIT IS ISSUED MIT IS ISSUED AND THAT ALL WORK DONE WILL BE IN AND ALL WORK DONE WILL BE IN CONFORMANCE CONFORMANCE THEREWITH. NO CHANGES SHALL BE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT MADE WITHOUT FIRST OBTAINING APPROVAL FROM FIRST OBTAINING APPROVAL FROM THE BUILDING THE BUILDING DEPARTMENT. DEPARTMENT. X OWNER X BY DATE DATE FOR OFFICIAL USE ONLY:Accepted by: Date: DEPARTMENTAL REVIEW FOR OFFICE USE ONLY Approved Cond. Hold Approval Planning: 1.00 Environmental Health: Building Plan Review r� Occupancy Group:_ Type of Const:S— o N Fire Marshal: Other: Special Conditions: FEES Building Permit Plan Check o Plumbing Fee tj Z- `='© Mechanical Fee 27 . `� d Wood/Gas/Pellet Stove Radon Monitor Violation Fee Site Inspection Building State Fee 4j .S0 Other Other Building Valuation: TOTAL FEE "MASON COUNTY STRUCTURAL REVIEW COMMENTS" RE: Job: BLD94-1110 Prince of Peace C� 1) (Per table 33-A #29 UBC) Max. occupancy load = 244 persons 2) (Per table 5-A) Occupancy Classification: A-3 3) Proposed Floor area = 5,000 G 4) (Sec. 2201 UBC) Type of construction = V One-Hour *Sprinkler system installed 5) Occupancy construction requirements per classification: A) Light: (Sec. 605 UBC) Must provide natural light by means of exterior glazing with an opening area of not less than one tenth of the total floor area, 5000 sq. ft. = 500 sq. ft. of exterior glazing, or shall be provided with artificial light. B) Ventilation: (Sec. 605 UBC) Must provide natural ventilation by means of open able exterior openings equal to one twentieth of the total floor area. 5000 sq. ft. = 1000 sq. ft. of exterior opening area or shall have a mechanically operated venting system capable of supplying minimum of 5 cubic feet per minute of outside air per occupant with a total circulation of not less than 15 cubic feet per minute per occupant while building is being occupied. If air velocity at registers exceeds 10 feet per second, the register shall be placed more than 8 feet above the floor directly beneath. C) (Exiting: (Sec. 3302 UBC) A) Posting of room capacity; any room having an occupant load of 50 or more must provide sign capacity. Sign must be posted in a conspicuous place on an approved sign near the main exit from the room. Such signs shall be maintained legible by the owner authorized agent and shall show the max occupant load. D) (Doors: (Sec. 3304) B) The door latch shall release when subjected to 15 lbs. of force, and the door shall be set in motion when subjected to 30 lbs. of force. The door shall swing to a full-open position when subjected to 15 lbs. of force. E) Panic Hardware: (Sec. 3304-D) When installed shall comply with the requirements of UBC Standard No. 33-4. The activating member shall be mounted at a height not less than 30" or more than 44" inches above the floor. When balanced doors are used and "Panic Hardware" is installed. The push pad shall not extend across more than one half the width of door measured from the latch side required. Prince of Peace Page 2-2 F) Landings: (Sec. 3304-I) regardless of the occupant load there shall be a landing at each side of the door. The floor or landing shall not be more than 1/2 an inch lower than the threshold of the door way. G) Landings at doors: (Sec. 3304-J) Landings shall not reduce the landing dimension to less than half it's required width in any position. Dimension of such landing per ADA requirements is 60". H) Doors (Sec. 3304-J): Doors shall not reduce the landing dimension to less than half it's required width in any position. Dimension of such landing per ADA requirements is 60" STAIRWAY: A) Rise and Run: (Sec. 3306-C) Max rise 7" run shall not be less than I inches. No tread shall differ in height greater than 3/8". HANDRAILS: K) Handrails: (Sec. 3306-H): Must provide a graspable handrail down one side min. 1 1/2" to 2" inch cross dimension. Located 34" to 38" above stair tread nosing. Must be h f it and must extend not less than 12 beyond bottom riser. End shall full length o stairs a � Y terminate or return to newer posts or safety terminals. L) Exit Sign Illumination: (Sec. 3306-I) Exit shall be illuminated at any time the building is being occupied with having a light intensity of not less than 1 foot candle at floor level. M) Exit Signs: (Sec. 3314) Shall be installed at all required exits from the room. DUE TO THE INCREASE OCCUPANT LOAD THE BASEMENT BATHROOOMS MUST BE FINISHED PER SHOWN ON PLANS. THIS WOULD MEET REQUIREMENTS PER SANITATION. FINAL NOTE: NO INTERIOR PARTITIONS ARE GOING UP. THIS PERMIT IS FOR THE FINISH OF EXISTING BASEMENT BUT LEAVING IT A FULLY OPENED. EXIT DOORS THAT ARE IN PLACE ARE LARGE ENOUGH FOR THE EXITING REQUIREMENTS. *OK TO FRAME STORAGE ROOM WALLS ONLY. IT MUST BE FIRE BLOCKED AT THE TOP PLATES OF ALL FURRED OUT WALL AND NOT TO EXCEED 10' IN THE HORIZONTAL DIMENSION OF THE WALLS LENGTH. The BJSS GROUP C � � a ARCHITECTS & PLANNERS, AIA --- AUG 141yg2 GENERAL SERVICEF August 10, 1992 Mr. Dana Herron Mason County Building Department 426 W. Cedar Shelton, WA 98584 RE: New Prince of Peace Catholic Church Project File # 920211/B.6.a Dear Mr. Herron: In response to your letter to BJSS dated August 5, 1992, we would like to request your reconsideration regarding the classification of the Lower Floor Classroom #03 as an E-2 occupancy. Upon reviewing the UBC definition in Table No. 5-A and Chapter 8, Section 801, and the Owner's intended use of the subject room, it does not meet the E-2 classification definition. Per the Owner's programmed use, this room would be occupied up to two hours maximum each Sunday and one hour on one other day each week for rcligicu >;ucatio ., ro a to,ai of Three flours per week. This ievei of use is considerably less than the Code-defined "12 hours per week or four hours in any one day". We would propose t the occupancy classification for this room would more appropriately be B-2 or A-3. As an assembly area of less-concentrated use, its occupant load factor would be (27) maximum. Per Table No. 5-13, no occupancy separation would be required. Again, the "educational" use of the subject room consists of just one to two hours on Sundays and one hour one other day per week. Given that this level of use does not fall under the "E" classification, we request that a one hour occupancy separation not be required. A DIVISION OF THE BJSS GROUP INC. 320 WEST BAY DRIVE SUITE 212 OLYMPIA WA 98502 (206) 943-4650 FAX (206) 357-9022 . PAGE 2 We would appreciate your review and response, and feel free to call either myself or Todd Tovani should you have any questions. Thank you for your assistance on this project. Respectfully, THE BJSS GROUP Dwayne E. arkness, AIA cc: Tony Hannan, Prince of Peace Chris Fynboe, Fynboe & Oye Lee Becker, BHU Tom Urquhart, BHU Todd Tovani, BJSS I r "MASON COUNTY STRUCTURAL REVIEW COMMENTS" RE: Job: BLD94-1110 Prince of Peace 1) (Per table 33-A #29 UBC) Max. occupancy load = 244 persons 2) (Per table 5-A) Occupancy Classificatigg: A-S 3) Proposed Floor area = 5,000 4) (Sec. 2201 UBC) Type of constwr ion = V One-Hour *Sprinkler system installed 5) Occupancy construction requirements per classification: A) Light: (Sec. 605 UBC) Must provide natural light by means of exterior glazing with an opening area of not less than one tenth of the total floor area, 5000 sq. ft. = 500 sq. ft. of exterior glazing, or shall be provided with artificial light. B) Ventilation: (Sec. 605 UBC) Must provide natural ventilation by means of open able exterior openings equal to one twentieth of the total floor area. 5000 sq. ft. = 1000 sq. ft. of exterior opening area or shall have a mechanically operated venting system capable of supplying minimum of 5 cubic feet per minute of outside air per occupant with a total circulation of not less than 15 cubic feet per minute per occupant while building is being occupied. If air velocity at registers exceeds 10 feet per second, the register shall be placed more than 8 feet above the floor directly beneath. C) (Exiting: (Sec. 3302 UBC) A) Posting of room capacity; any room having an occupant load of 50 or more must provide sign capacity. Sign must be posted in a conspicuous place on an approved sign near the main exit from the room. Such signs shall be maintained legible by the owner authorized agent and shall show the max occupant load. D) (Doors: (Sec. 3304) B) The door latch shall release when subjected to 15 lbs. of force, and the door shall be set in motion when subjected to 30 lbs. of force. The door shall swing to a full-open position when subjected to 15 lbs. of force. E) Panic Hardware: (Sec. 3304-D) When installed shall comply with the requirements of UBC Standard No. 33-4. The activating member shall be mounted at a height not less than 30" or more than 44" inches above the floor. When balanced doors are used and "Panic Hardware" is installed. The push pad shall not extend across more than one half the width of door measured from the latch side required. 01 Prince of Peace Page 2-2 F) Landings: (Sec. 3304-I) regardless of the occupant load there shall be a landing at each side of the door. The floor or landing shall not be more than 1/2 an inch lower than the threshold of the door way. G) Landings at doors: (Sec. 3304-J) Landings shall not reduce the landing dimension to less than half it's required width in any position. Dimension of such landing per ADA requirements is 60". H) Doors (Sec. 3304-J): Doors shall not reduce the landing dimension to less than half it's required width in any position. Dimension of such landing per ADA requirements is 60" STAIRWAY: A) Rise and Run: (Sec. 3306-C) Max rise 7" run shall not be less than I inches. No tread shall differ in height greater than 3/8". HANDRAILS: K) Handrails: (Sec. 3306-H): Must provide a graspable handrail down one side min. 1 1/2" to 2" inch cross dimension. Located 34" to 38" above stair tread nosing. Must be full length of stairs and must extend not less than 12" beyond bottom riser. End shall terminate or return to newer posts or safety terminals. L) Exit Sign Illumination: (Sec. 3306-I) Exit shall be illuminated at any time the building is being occupied with having a light intensity of not less than 1 foot candle at floor level. M) Exit Signs: (Sec. 3314) Shall be installed at all required exits from the room. FINAL NOTE: NO INTERIOR PARTITIONS ARE GOING UP. THIS PERMIT IS FOR THE FINISH OF EXISTING BASEMENT BUT LEAVING IT A FULLY OPENED. EXIT DOORS THAT ARE IN PLACE ARE LARGE ENOUGH FOR THE EXITING REQUIREMENTS. *OK TO FRAME STORAGE ROOM WALLS ONLY. IT MUST BE FIRE BLOCKED AT THE TOP PLATES OF ALL FURRED OUT WALL AND NOT TO EXCEED 10' IN THE HORIZONTAL DIMENSION OF THE WALLS LENGTH. k-Y\,Je.4 �b9 V\ Mou ri � 9 �5 vvl �rSoIQ Coub� Rom_ 2UIL0106 PLQMt-,-S 4"V R6W 9 Z -104 7 L,4�w L-kL Slz'2ViLL-L LaWt* V L 6P, — 9 - l 110 (4Y-r(4(f-I4L-� 1 S o 0 2. A P P L L I1Z! O k G IZ 0 PLO MSf06 /M E6+A-t-�Ic-AL PL--Qvn tT FOQ OUC Gau'Z(�4 ✓i-r614 -mil 0 U-t b-4E Lo w 022- 1;Looi2 _ 4 L S b R-Z7 n 6" L-0 'A 2,E rA LJ Pq 06T h41 L L EIZ S4a7 MtT4L, S c-U P Owl t46 m SM 00l ` S 9 8ZA FIG (t'76 0 4� OE-S. 14 l WILL OURLIP� v OEIQ- i j4L- 1 ,331 utiltwvQrl� MEeRgbtlC.RL 4/-00E 5vz4- 506 padE 3s Y:3fS oflo V i Q l ls" (- ►M E��-IS P 0P. Q tWW VA L 0C v`) R ` /� i� K.]va IV�.V C,&y 6-r A L O GO IM P L 4 E-� W r4 j E Q EC)Uj QG-M e r.1,- 4 oS. �l 06 , pg6E -Z o Fov ( D� � vi�6 �o C tJ - 126Z-r VL-47 1-100LI'n " Ct -'�t+ V7 A-LL (�,t Q �o�, S o UUT�6 0 F� TtYI a VD E21 �Ep i2ov fl r 4 j � PN-�l2 L I�tJt(� jq l.L t;. LU L�- Aj.� To ?I-FL oC) c`S t. 1pE- C+ 11 PL, n-to 14 L C1 Q(U4 3 -z�s-3 50.E 13 a%"/. 5 L7 iR&.m L Q- . WR 0 q 5 Z� Prince of Peace Catholic Church P.O. Box 517 Belfair, WA 98528-0517 (206) 275-8760 November 15, 1992 �1 Mark Tompkins �� NpV 231992 Mason County Dept. of Health0 Box 86 e Services P S Shelton, WA. 98584 uENERALRER��C� Dear Mark, RE: Parcel Nos. 12319-75-00011 & 12319-75-00012 Bldg. Permit No. 92-1047 Prince of Peace Catholic Church Enclosed is our Application for a Perc TEst on our proposed building site. We are also enclosing the Fee of $140.00 The test holes are now available for inspection and we have enclosed a sketch of the Building Site and the Drain Field. Please advise us when you have made the inspection. We will be forwarding to you the Sewage System Design as soon as possible. If further information is required please call (206) 275-3505 Si erely �< —a;C'4- Joseph K. Testu, Acting Chm. Building Committee JKT:ab cc: Pat McCullough Encl Map to Property Cy Health Dept. Payment Schedule Memorandum, Prince of Peace Billing Sewage System Permit Application 0n-Site Sewage System Site Evaluation & Disposal Permit Check for $140.00 PQ o� pt�ec.� ��?��u �c C� u Q c pwcicl rho, !Z 3 5 .7S. y �3 •� �y S_ o0o r�o � 6u�co}�G Q °oo i I Z-eMtT i4.o, ap 92. ivq7 0� 4rjt.Lp S HNO 14 i LL EZCw►�T� �G��L ji �_ PJ(Qrl4 SIB ` R D • 3d� Q0� �luQtt sk°Q� �o¢Tq wo-r o 4 .SfµD i-f ILL �Zv TAN UFFT O W 8 ELFAi Q r lgI40 Q RO-QP. pgpt►N F�ttp S MC 4%40 TEST �+O LLS "F L 0CA Tc P t nl S O u iW War doQ M•& OF w � PQOOtQry, 4PP(2o>er mAT4t-{ 1oo l t*Sr 1 Prince of Peace Catholic Church P.O. Box 517 Belfair, WA 98528-0517 (206) 275-8760 August 25, 1993 Larry Waters, Inspector Mason County Dept. of General Services Post Office Box 186 Shelton, Washington 98584 Reference: Prince of Peace Catholic Church Building Permit 92-1047 Dear Larry, Because of the delay in complying with the Fire Marshal's requirements, we have been unable to proceed with con- struction under the subject permit. We are applying for an extension of Permit 92-1047. Please advise us of your action on this matter. S'q;�4, k/ �"T42XA.A. Joseph K. Testu, Acting Chm. Building Committee cc: Mike Byrne, Bldg. Dept. I i Page No. 1 CASE HISTORY FOR CASE NO.: BLD92-1047 PRINCE OF PEACE ............... 12/21/92 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By ------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- --- BLDA010 Application received / / / / 09/03/92 09/03/92 DJK BLDA600 File Possession / / / / 12/18/92 sent to Dave Salzer for review DH 12/18/92 DWH BLDB009 Fire Marshal Review 09/14/92 / / 09/15/92 DC 12/18/92 DWH BLDB110 Structural Plan Review 12/17/92 / / 12/17/92 DONE DH 12/18/92 DWH BLDB120 WSEC Compliance Review 09/11/92 / / / / NEED ENERGY CODE INFORMATION (WINDOW 12/18/92 DWH SCHEDULE, COMPLIANCE DATA ETC.) 09/14/92 mailed letter requesting information and compliance form to be completed and returned. RETURN TO ENERGY CODE WHEN DONE. BLDB129 Sent to Planning DC 09/150921SM92 / / 09/15/92 On Jason's Desk BLDB130MP138013@92eVEtlw 09/11/92 / / 10/13/92 Sent to Dan for WESC review. 10.13.92 BLDB200 Environmental Health Review 10/22/92 / / / / Forwarded to Mark Tompkins for Enviro. HOLD MMT 10/28/92 MMT Health Review while Debbera awaits WSEC Return to Compliance Info. 10-22-92. Need Energy when U B Dun. tanks. approved permit and design. BLDB210 Water Adequacy 10/28/92 / / / / Need application for determination of HOLD MMT 10/28/92 MMT water adequacy. BLDB220 Bldg Pre-issue Review 09/11/92 / / / / 09/11/92 DWH � J