Loading...
HomeMy WebLinkAboutMIS95-0602 Final Retaining Wall Repair - MIS Permit / Conditions - 11/25/1996 MASON COUNTY Mason County Bldg, III 426 W, Cedar RO. Box 186 Shelton, Washington 98584 M 1,S C: F" t_. l._A N t--,- 01 lJ 11-3 p E F1 M 1 ..T 1-'OR 1 NSPFCT I ONS CAL..L. 42 7- 9670 MI S95-0602 PARCEL. ;32.2245000081 PLAT :CAPt.0 D 1 V : BLK : LOT - JOB ADDRESS : NF 11301 NORTH SHORE RD RULFAIR APPL. I CAN 1 : BONN I F PR I TCHARD 876--3206 OWNF R x BONN I f- PR 1 TCHARD 876- 3206 LEGAL - CAD1'S SUIRISF 11FACH 11. 7t SF 4F 10 1 1.1 . PROJECT USCR I PT I ON : REPAIR OF RETAINING WALL (TWO 13--FOOT SECTIONS) PROJECT IOCATION : 1 1 M 1 L F:S FROM BUL.f A 1 R ON NORTH SHORE RD, WATERSIDE , FENCE AND DECK NE: 11301 NORTH SHORE AD ON LIGHT POLE . PROJECT NOTES : TYPF AMOUNT BY DATE RFcr i PT PLCK $ 8 ,50 CPH 08/28/95 0000 PIiMT $ 23 .00 CPH 08/2€3/95 0000 STFI• $ 4 .50 CPH 08/28/95 0000 TOTAL- 36 .00 OWNER OR AGENT / bATF_ MIS_F111, rev, 0061192 COMPLIANCE'. TO ATTACHED CONDITIONS IS � REQUIRED CONCRETE MECHANICAL MOBILE HOME Footings-Setback date by Ribbons date by Gas Piping date b Foundation Walls date by Set Up date by INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date by PLUMBING date by OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION 'C C, date by day' l��G7�/ date by MASON COUNTY Mason County Bldg, III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 P FEE f'2M I J- 0t?N0 1 7 1 ON : Case No . : MIS95-0602 For : BONNIE PRITCHARD Page : 1 1 ) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Art , Its rules , and the Mason County Shoreline Master Program . x 2 ) Temporary erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands . X 3 ► Approved per site-plan . X_ __, 4 ) Perforated drain lines Installed behind the toe of each proposed wall shall be routed by tightiine to a location behind the existing bulkhead wall where existing bulkhead weep holes can drain . X 5)• All approved plans are required to be on-site for inspection purposes . If inspection Is railed for and plans are not on site, Approval WILL NOT be granted . In addition, a Re- Inspection fee In the amount of $30 .00 per hour (minimum 1 hour ) will be charged and must be collected by this department prior to any further Inspections being performed or MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 approval granted . X e _� 6 ) 11011SUAN1 'TO 1991 UNIFORM BUILDING CODE , SECTION 305(C ) AND SECTION h13 , ALL SITFIS MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY . MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS . A RE1NSPFCTION FEE , BASED ON RATES IN TABLE 3A OF THE 1991 UNIFORM BUILDING CODE Wilt EjE ASSFSSED IF OWNER/CONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS, X 7) ALL CONSTRUCTION MUST MEET OR EXCEED ALL. LOCAL CODES AND (16C REQUIREMENTS 8 ) Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code, 1991 Ventilation and Indoor Air duality Code, the Uniform Building Code and/or Mason County Rpqulations must be approved by Mason County prior to construct i onX _. `-�_� 9) AL._I. CONSTRUCTION MUST MEE:D OR EXCEED LOCAL CODES . IF ANY QUESTIONS, PLEASE CALL THIS OFFICE BEFORE CONSTRUCTION . X r 10) CONSTRUCTION PROCESS TO BE FIELD CORRECTED A REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE .x i II `. . Page No. 1 CASE HISTORY FOR CASE NO.: MIS95-0914 PRINCE OF PEACE CATHOLIC NE1171 SAND HILL RD BELFAIR 12/09/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MISA010 Application received / / / / 11/21/95 11/21/95 KW MISA050 Approved For Issuance / / / / 12/18/95 DONE KS 12/18/95 KS MISA500 (F) Issue permit / / / / 12/18/95 DONE KS 12/18/95 KS MISA900 Telephone call / / / / 07/19/96 recived call from prince of peace of DONE SKM 07/19/96 SKM church asking about the requirment of the floor sink and the grease trap why, where, and how come and I advised them to get a code book and see what the book requires . MISB009 Fire Marshal Review 12/15/95 / / 12/18/95 see conditions. DONE DLS 12/18/95 DLS MISB110 Structural Plan Review 11/21/95 / / / / need more information PEND DH 12/15/95 DWH MISB110 Structural Plan Review 12/15/95 / / 12/15/95 not approved for LPG. Electric only. DONE DH 12/15/95 DWH MISB128 Addressing / / / / 11/21/95 DONE GMM 11/21/95 GMM MISB130 Planning Review 11/21/95 / / 11/21/95 DONE AHB 11/21/95 AHB MISB131 Environmental Health Review 12/18/95 / / 12/18/95 They need to become a certified kitchen DONE PSD 07/19/96 SKM priot to serving food to the public.psd MISB135 RLC Checklist Review / / / / 11/21/95 N/A AHB 11/21/95 AHB MISC050 Pre-site Inspection 06/26/96 06/27/96 06/27/96 see h:\wp\pop file for report. DONE SKM 07/19/96 SKM copy has been given to Mike Byrne and Dave Salzer. MISC050 Pre-site Inspection 07/05/96 / / / / SENT REPORT TO APPLICANT SENT SKM 07/05/96 SKM JOESEPH TESTIE / CO PRINCE OF PEACE CHURCH 1171 SAND HILL RD BELFAIR, WA. MISC130 Plumbing inspection 07/10/96 07/11/96 11/25/96 1. ON THE 3 COMPARTMENT FOOD PREP SINK DONE MJB 12/02/96 MJB THE DRAIN OFF THE BOTTOM NEEDS TO BE TO AN INDIRECT WASTE. 2. THERE NEEDS TO BE A GREASE TRAP TANK INTERCEPTOR, I SPOKE WITH JOE TESTO HE STATES THERE IS ONE INSTALLED ON THE EXTERIOR OF THE BUILDING AND IT WAS INSPECTED BY THE HEALTH DEPT. 3. ON THE HAND WASH SINK A STANDARD P TRAP FITTING NEEDS TO BE USED. 4. ON THE 2 DISH WASHER DRAINS CENTER THE PIPES OVER THE INDIRECT WAST FLOOR SINK AND LEVEL A 1 INCH GAP BETWEEN THE TERMINATION ON THE PIPE AND THE TOP OF THE FLOOR SINK. Completed..Site inspection..11-25-96 mjb Page No. 2 CASE HISTORY FOR CASE NO.: MIS95-0914 PRINCE OF PEACE CATHOLIC NE1171 SAND HILL RD BELFAIR 12/09/97 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MISC135 Mechanical inspection 07/17/96 07/19/96 11/25/96 1. Mechanical portion of kitchen is as DONE MJB 11/25/96 MJB per code.EXCEPT FOR THE EXHAUST OF THE KITCHEN FAN , WHICH WILL NEED TO BE APPROVED BY THE BUILDING OFFICAL. 2. Fan specs show that the fan cfm is above 1500cfm and less than 2500cfm which is acceptable. 3. Will still need specs on the liquid tight sealer that is used on the hood to duct connection instead of the welded joint that the UMC calls for at this conection point. ---------------------------------------- ----------------- THEY HAVE SUBMITTED A SET OF PLANS TO SHOW WHAT IS ACTUALY IN PLACE IN THE KITCHEN, and they are being sent to the file, and attached to the hard card. FINALED PER SITE INSPECTION 11-12-96. ANY REMODELING OF KITCHEN WILL REQUIRE DUCT WORK TO MEET MECHANICAL CODE. MJB 11-25-96 MISC155 Final inspection 11/22/96 11/25/96 11/25/96 DONE MJB 12/02/96 MJB