Loading...
HomeMy WebLinkAboutMIS94-0033 Sprinkler System - MIS Permit / Conditions - 1/27/1994 E V E p5-CF:AVED MASON COUNTY JAN J 11994 JAid 2 7 �c 14 Mason County Bldg, III 426 W. Cedar I GENERAL SERVICES P.O. Box 186 Shelton, Washington 98584 PTtisg :A M = S G E L L +4 N E O lJ S P E R M IT FOR INSPECTIONS CALL 427-96 70 MIS94-0033 PARCEL : 12319750O010 PLAT : DIV: BLK : LOT : JOB ADDRESS : NE 1171 SAND HILL RD BELFAIR APPLICANT : PRINCE OF PEACE 275-6374 275-8760 OWNER : PRINCE OF PEACE 275-6374 275-8760 LEGAL : TR 1 Of SURV 16/95 fS 15141:A PROJECT DESCRIPTION : SPRINKLER SYSTEM PROJECT LOCATION : NORTH SHORE ROAD TO SAND HILL ROAD . APPROX 1 . 9 MILES SITE IS ON THE LEFT JUST PAST SAND HILL ELEMENTARY . PROJECT NOTES : TYPE AMOUNT BY DATE RECEIPT PRMT $ 175 . 00 KS 01 /26/94 0032 7,91 TOTAL : 175 . 00 / WNER 0 AGENT DATE T MIS_PR4T, rev: 0 4/0 1/9 2 COMPLIANCE TO ATTACHED CONDITIONS IS REQUIRED MASON COUNTY Mason County Bldg. 111 426 W, Cedar P.O. Box 186 Shelton, Washington 98584 Case No . : MIS94-0033 For : PRINCE OF PEACE Page : 1 FIRE MARSHAL COMMENTS : 1 . STATIC TEST REQUIRED . 2 . SCHEDULE FINAL ACCEPTANCE TEST AND COORDINATE WITH FIRE ALARM CONTRACTOR . | | F'NT I i iT F I REF'F'pTEC.T I UN 206 ' : � 615;, P. (1l ASON COUNlY FIRE MARVAL ffQII4n CoCln ii*y t1dQ-IN 420'vV.{:blot `. P.O Box 186 Shelton,Wasningron 98584 [2t}4J A2)-9G7U ENFORCENFNT FIRE IN$PE OTIONS FIDE INVESTIGATION E•`.'i''�:3;b�•t p MASON COUNTY FIRE PROTECTION PER :T ARIPLICATION FILE COPY NQTEr Th.ie application must be _i>mpleted and accompaniea by a viinimum of three (3) copies of plane, apecifications and applicable calculations per Mason County Fire Protecr.3.on Standards and brought to the office of the Mason County Fire. Marshal. This is not a pervi.t, and failure to submit all necessary information wiii ca'.zb-. a delay and/or rejection of your submittal. When a ;permit hats Leten in!I ued, you will' ne notified. #x OWNfiR I ►.'C' ' SYTE ADDRESS .. FT" DIST - {_ C YT'I[ ca.i T - STTATE j Z I n R.KCTTOXs TO J70H SITE - ti I � oV ltaR rn.ILIN ADDRESS CIT`l ►f= -- _ 5TATE � IP�J'� ";r L': .. "'7'L : HOLDER_��� #2 COWTR.ACTORJ- ra i�-, }J CONTRACTOR REG # ? -TfK!E .A.DIDRESS EXP. DATE: .._.STATE_j4�At; . ZIP. f ..... - 13Ck1 LEGS L'�FSCR1 PTXON #4 BLDG. SQ, FT (FXI5T1NGJFR0P08n) � 1,ST FL _ -— �O p[� / 2ND 3 RTC EASEMENT� / DECR ---_-- / #5R #BATg ---- ---------- GARAGE �..._._. ---- _ - ------_-/---- -- CARPORT_.__.. _-�- __-- -- -F►NCL ATTIC: Y.Y N US33 OR BUILDING ��'U► �� #5 DESCRIPTION OF WORK: SPRINKLER: WET DRY'g ST.ASTDPIPM: %-ET DRY AUTOMATIC FIRE AT,ARM- CORRIDOR S1.146kE.S U00D & DUCT DRY C i h.OAL WET CHEY-iCA.L _ HALON NEW SYSTSM MODIFICATION W NUMBER OF NEW DEVICES MOXITORTNG PATF.',7T FIRE FROTE1-710tl 2aG 91212 eiFFI #6 DOPS YOUR sMKITTAL IRCLUDE x 1. DrKENSIONS, SCALE, NORTH ARROW? AS NO 2 . FLOOR PLAN AIM CROSS SECTIONAL ELEVATION? yss;f—� NC- 3 , AT,t CONCEALED SPACES (LABELED COKBVS'VISLI AM NON-COMBUSTIBLE) ? 4 . ALL AREAS ON OPPOSITE SIDE OF ITEN WALL0 YES_NO_ -, . C"T SHEETS OR REFERENCES FOR ALL NEW DEVICHS? YES NG 6 . LOCATION/DESCRIPTION OF ANY EXISTING DEVICES "YES __K0_ 7 , BATTERY CALCULATIONS FOR FIRE ALARK SYSTEMS? YES NO F" FOR FIRE ALARM SYSTEMS? YES NU 8. RISER/WIRING DIAGRAM q , HYDRAULIC CALCULATIONS FOR SPRINXLER SYSTM4S? YES NQT&- WORK MAY PROCEED ON14Y IN ACCORDANCE KITE A VA PROTECTION SYSTEM PERMIT ISSUED BY THE MASON COW' " 21" MARSHAL- A VALID PERMIT AND AN "PkOVIFD SET OF PLANS NUST BE ON THE JOB SITE DURING CONSTRUCTION M MUST REMAIN THERt , UNTIL A FINAL INSPECTION IS DON"19 BY THE MASON'r C_01j14'1_y FlkE MAR,ShAL. FAILURE TO OBTAIN A VALID PERMIT PRICk TO WOPKING ON A FIRE PROTECTION SYSTEK AND/OR FAILURE TO PROVIDE THESE PLMS AIM PER141;T FOR TRR 'MASON COUNTY FIRE MMSEW, MAY RESULT IN A CITATION A11D FINE. I certify that I am exe-mPt from the requirem6=tg Of thG Ccutrac- tors Registration Law RCW 18.27, and am aware of the MasOn COuutY ordinance requirements for which this Psrlgit is issued and that all work will be dace in confo=ance therewith. No changes will be ,made without first obtajaing approval frOM the MaBOn COU"tY Fira I Certify that Ism a currently r6giStsrnd c0lltractOz in the gtat6 of Washington and I am aware of the ordinance ,requirements regillating the work for which the permit 18 issued =d all work dorte Wi3l he in Conformance therewith. No Chaages will be made without firot obtainiiag approval LXOm the MascJn "OLtaty F'" zz-I-7_A6-'