Loading...
HomeMy WebLinkAboutMIS95-0914 Cancelled 2 Sink, Oven, Stove, Dishwasher - MIS Permit / Conditions - 6/15/1996 MASON COUNTY y Mason County Bldg. III 426 W. Cedar t >✓ P.O. Box 186 Shelton, Washington 98584 M 1 C E 1— L_.. A N F C71..1 S F" FF R M 1 T FOR INSPECTIONS CALL 427-9670 M I S95--0914 PARCEL 0 23 1 9750001 0 PLATS DIVI BLK : LOTS JOB ADDRESS : WE 1171 SAND H I L !. RD BFI_FA I R APPLICANTS PRINCE OF PEACE CATHOLIC 275-6374 275-8760 OWNER : PRINCE OF PEACE CATHOLIC 275--6374 275-8760 LEGAL : T1 f Of SIIY 16195 EXCEPT RE 1 f li SAND if LL 18 PROJECT DESCRIPTION : INSTALL 2 SINKS CONVECTION OVEN AND COUNTER TOP GAS STOVE , DISHWASHER PROJECT LOCATIONS HWY 300 WES'f OF 8FL.FAIR RIGHT ON SANDHILL RD 1 MILT ON LEFT, WEST OF SAND Hli_L ELEMFNTARY SCHOOL . PROJECT NOTES : TYPE AMOUNT BY DATE RECEIPT PL.FE $ 9 .00 KS 12/ 18/95 0 P' IS * 15 .00 KS 12118/95 0 MC F E S .00 KS 12/ 18/95 0 MCE3S 9t 1 5 .00 KS 12/ 18/95 0 TOTAL : 45 .00 WNER OR AGENT DATE #IS fill, rev: 0091192 COMPLIANCE TO ATTACHED CONDITIONS IS REQUIRED CONCRETE MECHANICAL MOBILE HOME Footings-Sett-ack date by Ribbons date by Gas Piping date b Foundat" Nlaiis date b Set Up date by. INSULATION date by BG/SLAB Insulation Floors Final date by date by date by FRAMING Walls FIRE DEPT. date by date b date by PLUMBING y OTHER Groundwork Attic date by date by D.W.V. WALLBOARD NAILING date by date by Water Line FINAL INSPECTION date by date by date by i MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 i" � RM I T Ct:yNt7 I T I C�N :� Case No . : MI895-0914 For : PR !NCE OF PEACE CATNOL. I C Page : 1 1,) Not approved for LPG, electric only , hood to be installed according to listing and URIC . 2 ) All approved plans are required to be on-site for inspection purposes . If inspection is x_ called for and plans are not on site, Approval WILL NOT be granted . In addition , a Re- Inspection fee In the amount of $30 .00 per hour (minimum 1 hour ) will be charged and must be collected by this department prior to any further inspections being performed or approval grantee . 3 ) . ALL TRUCTION MUST MEET OR EXCEED ALL LOCAL. CODES AND i.lBC . REQUIRFMENTC _ ) Changers to approved PProved building plans that effect compliance to the 1991 Washington }fate Energy Code, 1991 Ventilation and indoor Air Quality Code , the Uniform Building Code and/or Mason County Regulations must be approved by Mason County prior to construct I onX_ �A MASON COUNTY • Mason County Bldg. III 426 W Cedar P.O. Box 186 Shelton, Washington 98584 tk) CONS-rP.UCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE .x _____ p1/ �) 1 . AS INDICATED ON THE PLANS, THIS HOOD IS DESIGNED TO REMOVE GREASE-LADEN VAPORS , AS SUCH, A FIRE SUPPRESSION SYSTEM IS REQUIRED UNDER THE HOOD . THE FIRE SUPPRESSION SYSTEM SHALL ME THE REQUIREMENTS OF UL. 300 . ACTIVATION OF THE SYSTEM SHALL BE SEPARATELY ZONED TO THE FIRE ALARM PANEL. AND WILL ALSO DISCONNECT THE FUEL SOURCE TO THE COOKING SURFACES . SEPARATE PLANS ARE REQUiRFD AND A SEPARATE PERMIT SHALL. BE. ISSUED . 2 . PROVIDE A NON A-RATED 406C PORTABLE FIRE EXTINGUISHER WITHION 30 FEET OF THE COOKING SURFACE . MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 M I SCE L. L_ A N E C3 U S P E R M I T FOR INSPECTIONS CALL 427-9670 MIS95-0914 PARCEL : 123197500010 PLAT : DIV : BLK : LOT : JOB ADDRESS : NE 1171 SAND HILL RD BELFAIR APPLICANT : PRINCE OF PEACE CATHOLIC 275-6374 275-8760 OWNER : PRINCE OF PEACE CATHOLIC 275-6374 275-8760 LEGAL : TR 1 OF SURV 16195 EXCEPT NE 1171 SAND HILL RD PROJECT DESCRIPTION : INSTALL 2 SINKS CONVECTION OVEN AND GAS STOVE , DISHWASHER Ft:j�e 5j"AND!10C, M�J ?� 44:5I`Z. PROJECT LOCATION : HWY 300 WEST OF BELFAIR RIGHT ON SANDHILL RD 1 MILE ON LEFT, WEST OF SAND HILL ELEMENTARY SCHOOL . PROJECT NOTES : TYPE AMOUNT BY DATE RECEIPT PLFE $ 9 .00 KS 12/ 18/95 0 PLBS $ 15 .00 KS 12/ 18/95 0 MCFE $ 6 .00 KS 12/ 18/95 0 MCBS $ 15 .00 KS 12/ 18/95 0 '�,L_ -Aj J TOTAL : 45 .00 OWNER OR AGENT DATE MIS PRMT, rev: 04/01192 COMPLIANCE TO ATTACHED CONDITIONS IS REQUIRED MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 P E R M I T C ONO I T I O N S Case No . : MIS95-0914 For : PRINCE OF PEACE CATHOLIC Page : 1 - � hood to be installed according to listing and UMC . / All approved plans are required to be on-site for inspection purposes . If inspection is called for and plans are not on site , Approval WILL NOT be granted . In addition , a Re Inspection fee in the amount of $30 .00 per hour (minimum 1 hour ) will be charged and must be collected by this department prior to any further inspections being performed or approval granted . X ALL ONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND UBC REQUIREMENTS X Changes to approved building plans that effect compliance to the 1991 Washington State Energy Code , 1991 Ventilation and Indoor Air Quality Code , the Uniform Building Code and/ or Mason County Regulations must be approved by Mason County prior to constructionX �1CQ MASON COUNTY Mason County Bldg, III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM BUILDING CODE . x �I) 1 . AS INDICATED ON THE PLANS , THIS HOOD IS DESIGNED TO REMOVE GREASE-LADEN VAPORS . AS (� SUCH , A FIRE SUPPRESSION SYSTEM IS REQUIRED UNDER THE HOOD . THE FIRE SUPPRESSION SYSTEM SHALL ME THE REQUIREMENTS OF UL 300 . ACTIVATION OF THE SYSTEM SHALL BE SEPARATELY ZONED TO THE FIRE ALARM PANEL AND WILL ALSO DISCONNECT THE FUEL SOURCE TO THE COOKING SURFACES . SEPARATE PLANS ARE REQUIRED AND A SEPARATE PERMIT SHALL BE ISSUED . 2 . PROVIDE A NON A-RATED 40BC PORTABLE FIRE EXTINGUISHER WITHION 30 FEET OF THE COOKING SURFACE . MASON COUNTY Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton, Washington 98584 -TA) 5 PEC.TSO �j R'E pd kt M I -0 V7 i_. L A N F F f3 U � P E- R M I _T FOR INSPECTIONS CALL 427-9670+ MI S95-0914 PARCE:1. : 1 23 1 9750001 0 PLAT : DIVI BL.K : LOT .- JOB ADDRESS : NE 1171 SAND Hill RD RFLFAIR APPLICANT : PRINCE OF PEACF CATHOLIC 975-6374 27.5-8760 OWNER : PRINCE Of" PEACE CATHOLIC 975--6374 275-8760 LEGAL : TA 1 Of SHAY 16195 EXCEPT IF 1171 SAND HILL AD PROJECT DESCRIPTION : INSTALL 2 SINKS CONVECTION OVEN AND COUNTER TOP GAS STOVE , DISHWASHER PROJECT LOCATION : HWY 300 WEST OF BFLFAIR RIGHT ON SANDHILL RD 1 MILE ON LEFT , WEST OF SAND BILL. ELEMENTARY SCHOOL . PROJECT NOTES : PaYCe-1 I2-31(;'—) S000 10 TYPE AMOUNT BY DATE RECEIPT PLFE $ 9 .00 KS 12/ 18/95 0 PLBS N 15 .00 KS 12/ 18/95 0 MCFE 6 ,00 KS 12/ 18/95 0 MCBS $ 15 .00 KS 12/ 18/95 0 _ TOTAL : 49 .00 (PWNERI OR AGF.MT DATE NIS 1AN1, rev: 94i91192 COMPLIANCE TO ATTACHFD CONDITIONS IS REQUIRED r r t MIS95-0914 DATE OF INSPECTION 6/27/96 PRINCE OF PEACE CATHOLIC CHURCH PRE-CONSTRUCTION INSPECTION COMMERCIAL KITCHEN PRE CONSTRUCTION INSPECTION 1 . Scope of project : Install convection oven and counter top gas stove, dishwasher. Code sections referenced in report are from 1994 UBC, 1994 UMC, and 1991 UPC. At the time of inspection 6/27/96 there was a 16ga. stainless steel kitchen hood mounted at aprox. 18" from the ceiling at the closest point, and mounted directly to the back wall . the hood was suspended with noncombustible hanger brackets and secured to the ceiling framing . SECTION 5.05 . 7 UMC REQUIRES THAT HOODS BE MOUNTED WITH THE SAME CLEARANCE TO COMBUSTIBLES AS THAT REQUIRED FOR GREASE DUCTS SYSTEMS. 2 . There is also a 16ga. stainless steel grease duct extending from the top of the hood to the exterior of the building and terminating horizontialy through the exterior wall to a point 91above grade at its lowest point, aprox. 5' from an exterior fire door opening to the kitchen. SECTION 507 . 11 UMC REQUIRES EXHAUST OUTLETS FOR GREASE DUCTS SERVING COMMERCIAL FOOD HEAT-FOOD PROCESSING EQUIPMENT SHALL EXTEND THROUGH THE ROOF UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICAL. SUCH EXHAUST SHALL BE AT LEAST 2 ' ABOVE THE ROOF SURFACE, AT LEAST 10' FROM PARTS OF THE SAME OR CONTINUOUS BULDINGS, ADJACENT PROPERTY LINE OR AIR INTAKE OPENING INTO ANY BUILDING, AND SHALL BE LOCATED AT LEAST 10' ABOVE THE ADJOINING GRADE LEVEL. 3 . The grease duct passes through the kitchen side wall, and is protected by a 5/8" wrap of type X gwb elevated with 26ga. sheet metal saddle to provide the required 3" clearance . SECTION 507 . 6 UMC REQUIRES THAT THE DUCT ENCLOSURE BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATIONAND VENTED TO THE EXTERIOR THROUGH WEATHER -PROTECTED OPENINGS . THE ENCLOSURE SHALL BE SEPERATED FROM THE DUCT BY AT LEAST 3" AND NOT MORE 12" AND SHALL SERVE A SINGLE GREASE DUCT EXHAUST DUCT SYSTEM. 4 . The fan provided to service the hood is a 3/4 hp rated at 1350 rpms, the factory specs were not at the site at the time of inspection the contractor will provide them for verifacation of the required minimun and maximun air velocity. SECTION 507 . 8 UPC REQUIRES THAT GREASE DUCT SYSTEMS SERVING A TYPE 1 HOOD SHALL BE DESIGNED AND INSTALLES IN A MANNER TO PROVIED AN AIR VELOCITH WITHIN THE DUCT SYSTEM OF NOT LESS THAN 1, 500 FEET PER MINUTE AND NOT TO EXCEED 2 , 500 FEET PER MINUTE . 5 . During the pre-site inspection the requirment for make up-air was not addressed but will need to be provided. SECTION 402 . 4 UMC REQUIRES EACH COMMERCIAL KITCHEN SPACE PROVIDED WITH AN EXHAUST SYSTEM SHALL HAVE AIR SUPPLIED TO THE ROOM EQUAL TO THE AMOUNT OF AIR TO BE EXHAUSTED. MAKE UP DIFFUSERS SHALL BE LOCATED TO PREVENT A SHORT-CIRCUITING OF AIR FURNISHED TO THE EXHAUST SYSTEM. WINDOWS AND DOORS SHALL NOT BE USED FOR THE PURPOSE OF PROVIDING MAKEUP AIR. THE EXHAUST AND MAKE UP-AIR SYSTEM SHALL BE CONNECTEED BY AN ELECTRIC INTERLOCKING SWITCH. COMPENSATING HOOODS SHALL MEET THE AIR FLOW REQUIRMENTS SPECIFIED IN SECTIONS 508 . 7 . 2 THROUGH 508 . 7 . 4 . COMPENSATING HOODS SHALL EXTRACT AT LEAST 20 PERCENT OF THEIR REQUIRED EXHAUST AIRFLOW FROM THE KITCHEN AREA. ------------------------------------------------------------------- 6 . APPROPRIATE PERMITS AND PLANS WILL BE REQUIRED FOR THE PROJECT AS SPECIFIED IN SECTION 106 UBC , SECTION 112 UMC , AND SECTION 30 . 2 UPC. ------------------------------------------------------------------- 7 . PLUMBING REQUIRMENTS AS PER 1991 UPC. DETAILS FROM THE ILLUSTRATED HANDBOOK ARE ATTACHED skm H: \wp\PoP ? UPC ILLUSTRATED TRAINING MANUAL i Fixture Unit Equivalents } The unit equivalent of plumbing fixtures shown in Tables 4-1 shall be based on the size of the trap required. The unit equivalent of fixtures and devices not shown in Table 4-1 shall be based on the rated discharge capacity in GPM (gallons per minute) (liters per minute or per second) in accordance with Table 4-2. Maximum trap loadings for sizes up to four(4) inches (101.6 mm) are as follows: 1-1/4"- (31.8 mm) - 1 unit 1-1/2"- (38.1 mm) - 3 units 2" - (50.8 mm) - 4 units 3" - (76.2 mm) - 6 units 4" - (101.6 mm) 8 units rI EXCEPTION: On self-service laundries. The exception is made for self-service laundries because of the footnote at the end of Table 4 1. This ` states that clothes washers in groups of three (3) or more shall be rated at six (6) units each for the purposes i of common horizontal and vertical waste pipe sizing. It is common practice, without any difficulties, to install three (3) clothes washers on a three inch (76.1 mm) trap or four (4) clothes washers on a four(4) inch (101.6 mm) trap. Without this exception traps would be overlooked by sizing according to this table. TABLE 4-1 Minimum Trap &Trap Arm Size Kind of Fixture (inches) (mm) Units 38.1 2 Bathtubs ......................................................................................................... 1-1/2 (38.1) 2 Bidets .............................................................................................................. 1-1/4 (31.8) 1 Dental units or cuspidors ................................................................................ 1-1/4 (31.8) 2 1 Drinking fountains l ....................................................... (50.8) 2 1 ins .................................... Floordrains ..................................................................................................... 'Interceptors for grease, oil, solids,etc. .......................................................... 3 (762) 6 "Interceptors for sand, auto wash, etc........................................................................ 2 (50.8) 2 1-1/2 (38.1) 2 Laundrytubs ........................................................................................ Clotheswashers .............................................................................................. 'Receptors (floor sinks), indirect waste receptors for refrigerators, 1 coffee urns,water stations, etc. .............................................................. 1 1/2 (38.1) `Receptors, indirect waste receptors for commercial sinks, 3 ' dishwashers, air-washers, etc. ............................................................... 2 (50.8) Shower, single stalls ....................................................................................... 2 (50.8) 2 `Showers, gang, (one unit per head .•• "'j p ) ...:......rite) 1-1/2 ' (38.1) 1 Sinks, bar, private (1 1/2" (38.1 mm) min.waste) .......................................... 2 Sinks, bar, commercial (2" (50.8 mm) min.waste) ......................................... 1-1/2 (38.1) Sinks,commercial or industrial, schools, etc. including dishwashers, 1 1/2 (38.1) 3 wash up sinks,and wash fountains(2"(50.8mm) min. waste) ..............: 3 (76.2) 6 E Sinks,flushing rim, clinic ""...... "' ' Sinks, and/or dishwashers (residential) (2" (50.8mm) min.waste) .............. 2 (50.8) 3 Sinks, service .................... ........................................... 3 ( ) Mobile home park traps (one (1)for each trailer) ........................................... 3 (76.2) 6 Urinals, pedestal,trap arm only ................................................................. 50.8) 2 Urinals, stall, separate trap ••••• • ......••.. """'................"" 2 ( 2 2 Urinals,wall (2" (50.8mm) min.waste) mounted,washout, separate trap...... 1-1/2 (58.8) Urinals,wall mounted,was or siphon jet, integral trap,trap arm only... 2 2 (50.8) 3 Urinals,wall mounted, blowout, integral trap,trap arm only............................ 3 (76.2) 6 ' Urinals,wall mounted, blowout integral trap,trap arm only..........................•• 1-1/4 (31.8) 1 Wash basins (lavatories) single ...................................................................... 1-1/2 (38.1) 2 ................................................ 3 (76.2) 4 I Wash basins, in sets ................................... . . 76.2 *Water closet, private installation, trap arm only ....................................... 3 (76.2) 6 Water closet, public installation,trap arm only ............................................... iI i 212 7 DRAINAGE CHAPTER 4 *NOTE- The size and discharge rating of each indirect waste receptor and each interceptor shall be based on the total rated discharge capacity of all fixtures, equipment, or appliances discharging therein to, in accordance with Table 4-2. Drainage piping serving batteries of appliances capable of producing continuous flows shall be adequately sized to provide for peak loads. Clotheswashers in groups of three (3) or more shall be rated at six (6) units each for the purpose of common horizontal and vertical waste pipe sizing. Water closets shall be computed as six(6)fixture units when determining septic tank size based on Appendix 1 of this Code. Trap sizes shall not be increased to a point where the fixture discharge may be inadequate to maintain their self-scouring properties. TABLE 4-2 Discharge Capacity (In gals. per min.) (liters per sec.) For Intermittent Flow Only GPM Us Up to 7-1/2 Up to .47 Equals 1 Unit 8 to 15 .50 to .95 Equals 2 Units 16 to 30 1 to 1.89 Equals 4 Units 31 to 50 1.95 to 3.15 Equals 6 Units Over 50 gals. per min. (3.15 Us) shall be determined by the Administrative Authority. For a continuous flow into a drainage system, such as from a pump, sump ejector, air conditioning equipment, or similar device, two (2) fixture units shall be allowed for each gallon per minute (0.06 Us) of flow. A fixture unit is a quantity in terms of which the load-producing effects on the plumbing system of P 9 P 9 Y different kinds of plumbing fixtures are expressed on some arbitrarily chosen scale. The size of drainage piping is determined from the total number of fixture units connected thereto. This is the load producing effect. Most of the common types of plumbing fixtures with yp t their assigned fixture unit values are listed i P 9 g n Table 4-1. For any fixture, which is to be connected to a drainage system, and for which the fixture unit value is not given in Table 4-1, it will be necessary to assign a fixture unit value based on the gallon per minute (liters per minute or per second) discharge as given in Table 4-2. Size of Drainage Pipe p (a) The minimum size of vertical and/or horizontal drainage piping shall be determined from the total of all fixture units connected thereto, and in addition, the case of vertical drainage pipes, in accordance with their length. (b) Table 4-3 shows the maximum number of fixture units allowed on any vertical or horizontal drainage pipe, building drain or building sewer' of a given size; the maximum number of fixture units allowed on any branch interval of a given size; the maximum length (in feet) (meters) of any vertical drainage pipe of a given size. "For building sewer 8" (203.2 mm) and larger use Table 11-2 ;r z 213 UPC ILLUSTRATED TRAINING MANUAL TABLE 4-3 Maximum Unit Loading and Maximum Length of Drainage and Vent Piping Size of Pipe(inches) 1-1/4 1-1/2 2 2-1/2 3 4 5 6 8 10 12 (mm) 31.8 38.1 50.8 63.5 76.2 101.6 127 152.4 203.2 254 304.8 Maximum Units Drainage Piping' Vertical 1 22 163 323 484 256 600 1380 3600 5600 8400 Horizontal 1 22 83 143 354 2165 4285 7205 26405 46805 82005 Maximum Length Drainage Piping Vertical (feet) 45 65 85 148 212 300 390 510 750 (m) 13.7 19.8 25.8 45 64.5 91.2 118.6 155 228 Horizontal(Unlimited) Vent Piping Horizontal and Vertical Maximum Units 1 83 24 48 84 256 600 1380 3600 Maximum Lengths(feet) 45 60 120 180 212 300 390 510 750 (m) 13.7 18.2 36.5 54.7 64.5 91.2 118.6 155 228 (See Note) 1 Excluding trap arm. 2 Except sinks, urinals and dishwashers. 3 Except six-unit traps or water closets. 4 Only four (4) water closets or six-unit traps allowed on any vertical pipe or stack; and not to exceed three (3) water closets or six-unit traps on any horizontal branch or drain. 5 Based on one-fourth (1/4) inch per foot (20.9 mm/m) slope. For one-eighth (1/8) inch per foot (10.4 mm/m) slope, multiply horizontal fixture units by a factor of 0.8. NOTE: The diameter of an individual vent shall not be less than one and one-fourth (1-114) inches (31.8 mm)nor less than one-half(112)the diameter of the drain to which it is connected. Fixture unit load values for drainage and vent piping shall be computed from Tables 4-1 and 4-2. Not to exceed one-third(113)of the total permitted length of any vent may be installed in a horizontal position. When vents are increased one (1)pipe size for their entire length, the maximum length limitations specified in this table do not apply. Properly sizing a drainage system requires thorough familiarization of Table 4-3. With the exception of the one and one-fourth inch (1-1/4) ( 31.8 mm) size all other sizes allow more unit loading on a vertical pipe than on a horizontal pipe of the same size. Also, footnotes from one (1) to five (5) are noted in Table 4-3 in specific locations and provide regulations as follows: (1) This excludes trap arms from being sized by this table. Trap arm sizes are sized by Table 4-1. (2) Except sinks, urinals, clothes washers and dishwashers. Most fixtures with one and one-half inch (1-1/2) (38.1 mm) traps and an assigned value of two (2) fixture units, by Table 4-1 will usually have a one and one-half (1-1/2) (38.1 mm) vertical drainage pipe, with the exception of sinks and urinals which are required to have a minimum size drainage pipe of two (2) inches (50.8 mm). (3) Except six-unit traps or water closets. You will note that footnote 3 is with reference to those units associated with two (2) inch (50.8 mm) and two and one-half (2-1/2) inch (63.5 mm) drainage piping. Six unit traps and water closets are required to have a minimum three (3) inch (76.2 mm) drainage pipe. It would be impractical to reduce the drainage piping in the direction of flow. (4) Only four(4) water closets or six-unit traps are allowed on any three (3) inch (76.2 mm) vertical pipe or stack and not to exceed three (3) water closets or six-unit traps on any three (3) inch (76.2 mm) horizontal branch or drain. i; F i `. i 214 E mot• �. . INDIRECT AND SPECIAL WASTES CHAPTER 6 INDIRECT AND SPECIAL WASTE SYSTEMS General The purpose of an indirect waste (airbreak or airgap) applied to any appurtenance or device used for the purpose of handling or preparing food, is to prevent the possibility of wastes backing up to a compartment where food is being stored or being processed and contaminating it. The improper connection of equipment of this type can cause a severe health hazard, so the installer should be well aware of the regulations governing such installations. No evaporative cooler, air washer, or similar air conditioning equipment and no cold storage room, refrigerator, cooling counter, compartment, receptacle, appurtenance, or device which is used, designed, or intended to be used for storage of food or drink shall have any drain pipe in connection therewith directly connected to any soil, waste, or vent pipe. All such equipment shall be drained by means of an indirect waste pipe. All wastes draining such equipment shall discharge through an airbreak into an open floor sink or other approved type receptor which is properly connected to the drainage system. ExcEPnoN: The foregoing does not apply to any dishwashing or culinary sink in any food preparation room, unless such receptacle is used for soaking or washing ready to serve food, or to walk-in refrigerators and combination walk-in, reach-in refrigerators used for storage and sales of products packaged in bottles, cartons or containers. Approval Required No plumbing fixtures served by indirect waste pipes or receiving the discharge thereof shall be installed until first approved by the Administrative Authority. An indirect waste pipe does not connect directly with the drainage system, but conveys liquid wastes by discharging into a plumbing fixture, interceptor or receptacle, directly connected to the drainage system. An airbreak is a physical separation which may be a low inlet into the indirect waste receptor from the fixture, appliance or device indirectly connected. See Fig. 6-1 a for an illustration of an airbreak. The size and construction of the indirect waste pipe and fittings in those systems shall conform to Section 603. Physical Separation Trap, if over 5 feet (1.5 m)in length ::1 i Figure 6-1a 247 UPC ILLUSTRATED TRAINING MANUAL The Uniform Plumbing Code covers only the basic plumbing problems in food processing sanitation in requiring the separation of certain critical equipment from sewer connected drains. The Health Department is vitally involved and generally works hand in hand with the Plumbing Official in arriving at the ultimate decision as to how fixtures of this type should be wasted. Design ,VP 7r►ip°C vfor Indirect waste pipes less than five (5) feet (1.5 m) in length need not be trapped or vented. Indirect waste y/oxy � pipes in excess of five (5) feet (1.5 m) in length but less than 15 feet (4.6 m) shall be directly trapped but these traps need not be vented. The size and construction of indirect waste pipes in excess of 15 feet (4.6 m) Y shall be directly trapped and vented and comply with the Code requirements regarding drainage and venting pipe. (See Fig. 6-3.) I I I I I I I I I I I I I � 15' (4.6m) • i I I I I I N-5' (1.5 m) Z 15' (4.6 m) I I I I . I I I L5' (1.5 m) I I I I I I 'TOTAL DEVELOPED LENGTH I I I Figure 6-3 Indirect waste pipe which is fifteen (15) feet (4.6 m) or less in length need not be larger than the outlet or tailpiece of the fixture served. No indirect waste pipe shall be less than one half (1/2) inch (12.7 mm) in size and that all angles and changes of direction shall be provided with a cleanout to permit cleaning and flushing of the lines. 250 INDIRECT AND SPECIAL WASTES CHAPTER 6 Basic Design and Size The basic design and size of an indirect waste pipe is dictated by the type of fixture and/or appurtenance being served. The UPC permits the use of a one-half (1/2) inch (12.7 mm) line as a minimum size for an indirect waste pipe, provided that it is sized in accordance with the sections of the Code on drainage and vent piping. A good example of this is a double compartment sink used to soak and wash ready-to-serve food. Proper design dictates that the drain outlet of each compartment be served by an one and one-half (1-1/2) inch (38.1 mm) tailpiece, which sets the size of the indirect waste pipe at one and one-half (1-1/2) inch (38.1 mm) and that if it exceeds five (5) feet (1.5 m) in length, it be directly trapped. The fifteen (15) foot (4.6 m) limit applies to its length. See Fig. 6-4 below. Over 5'(1.5 m)in length must be directly trapped. II Maximum length of indirect waste pipe is 15'(4.6 m). II I) II Airgap of not less than 1" than trap is needed if less I '% than 5'(1.5 m). Each change in direction shall be served by a cleanout. I - - Airgap of not less than 1" 0 Figure 6-4 Types and Location All plumbing fixtures or other receptors receiving the discharge of indirect waste pipes shall be approved for the purpose served. The capacity and shape of such receptors shall be designed to prevent splashing and flooding. All such receptors shall be located where they are readily accessible for inspection and cleaning. An indirect waste receptor shall not be located in any toilet room, cupboard, storeroom, or any portion of a building not in general use by the occupants. A clotheswasher standpipe receptor may be installed in a toilet or bathroom area, provided the clotheswasher is installed in the same room. 251 INDIRECT AND SPECIAL WASTES CHAPTER 6 Whether you are the inspector or the installer, extreme care shall be taken to see that an airgap is used, and not an airbreak when the use of sterile equipment is involved. An illustration of an indirectly wasted sterilizer is provided to clearly show how sterile equipment should be installed. See Fig. 6-2d for illustration of sterilizer wastes. All appliances. devices, equipment or other apparatus not regularly classed as plumbing fixtures which are equipped with pumps, drip or drainage outlets. may be drained by indirect waste pipes discharging into an approved type receptor. Again, here the decision as to whether an airbreak or an airgap is used hinges upon the type of equipment being served An example of this point is that the Code provides that no domestic dishwasher shall be directly connected to a drainage system or food waste disposer without the use of an approved dishwasher airgap fitting on the discharge side of the dishwashing machine. See Fig. 6-6. APPROVED DISHWASHER AIRGAP FITTING I I I I I I I DISHWASHER DIRECTIONAL TEE WASTE INLET APPROVED FOOD WASTE DISPOSER y FIN. FLOOR SEE UPC FOR LIMITATIONS ON GRAVITY HORIZONTAL WASTE. Figure 6-6 Domestic Dishwasher Hook-Up Condensate Wastes Condensate waste from air conditioning coils may be directly connected to a lavatory tailpiece or a bathtub overflow. However, it must be noted that when a condensate waste discharges by direct connection to a lavatory tailpiece or to an approved accessible inlet on a bathtub overflow. The connection shall be located in the area controlled by the same person controlling the air conditioned space. The Uniform Mechanical Code also covers indirect waste connections in reference to air conditioning f systems, especially with reference to location. The last sentence of this section states that condensate or waste water shall not drain over a public way. Clean running water used exclusively as a cooling medium in an appliance device or apparatus. may discharge into the drainage system through the inlet side of a fixture trap in the event that a suitable fixture is not available to receive the discharge. Such trap connection shall be by means of a pipe connected to the inlet side of an approved fixture trap, the upper end terminating in a funnel shaped receptacle set adjacent to, and not less than six (6) inches (152.4 mm) above the overflow rim of the fixture. See Fig. 6-7. 253 TRAPS AND INTERCEPTORS CHAPTER 7 6 ' I .� � 20' 18' VARIABLE MIN." c INLET OUTLET V a e• 6 • 0 l y 1'-10, TYP. � i Figure 7-41 Grease Interceptor APPENDIX H Recommended Procedures for Sizing Commercial Kitchen Grease Interceptors H 1 Waste Discharge Requirements (a) Waste discharge from fixtures and equipment in establishments which may contain grease, including but not limited to, scullery sinks, pot and pan sinks, dishwashing machines, soup kettles and floor drains located in areas where grease-containing materials may exist, may be drained into the sanitary waste through the interceptor when approved by the Administrative Authority. (b) Toilets, urinals, and other similar fixtures shall not waste through the interceptor. (c) All waste shall enter the interceptor through the inlet pipe only. H 2 Design (a) Interceptors shall be constructed in accordance with the design approved by the Administrative Authority and shall have a minimum of two compartments with fittings designed for grease retention. (b) There shall be an adequate number of manholes to provide access for cleaning all areas of an interceptor; a minimum of one (1) per ten (10) feet of interceptor length. Manhole covers shall be gastight in construction having a minimum opening dimension of twenty (20) inches. (c) In areas where traffic may exist the interceptor shall be designed to have adequate reinforcement and cover. H 3 Location (a) Each grease interceptor shall be so installed and connected that it shall be at all times easily accessible for inspection, cleaning, and removal of the intercepted grease. A grease interceptor may not be installed in any part of a building where food is handled. Location of the grease interceptor shall meet the approval of the Administrative Authority. (b) Interceptors shall be placed as close as practical to the fixtures it serves. (c) Each business establishment for which a grease interceptor is required shall have an interceptor which shall serve only that establishment. 289 UPC ILLUSTRATED TRAINING MANUAL H 4 Sizing Criteria (a) Parameters. The parameters for sizing a grease interceptor are hydraulic loading and grease storage capacity, for one or more fixtures. (b) Sizing Formula.The size of the interceptor shall be determined by the Following formula: rn i• Number of meals Waste flow retention storage Interceptor size per peak hour x rate x time x factor4 = (liquid capacity) 1 Meals Served at Peak Hour 2 Waste Flow Rate a. With dishwashing machine...........................................................................................................6 gallon flow b. Without dishwashing machine......................................................................................................5 gallon flow c. Single service kitchen.......................................... ..................2 gallon flow ....................................................... d. Food waste disposer....................................................................................................................1 gallon flow 3 Retention times Commercial kitchen waste Dishwasher........................................................................................................................................2.5 hours Single service kitchen Singleserving....................................................................................................................................1.5 hours 4 Storage Factors Fully equipped commercial kitchen...........................................................................................8 hour operation: 1 .........................................................................................................................................16 hour operation:2 .........................................................................................................................................24 hour operation:3 SingleService Kitchen.......................................................................................................................................1.5 H 5 Effluent Sampling An effluent sampling box on grease interceptors may be required by the Administrative Authority. H 6 Abandoned Grease interceptors Abandoned grease interceptors shall be pumped and filled as required for abandoned sewers and sewage disposal facilities in Section 1119 of the Uniform Plumbing Code. i 290 SIZING GREASE INTERCEPTORS APPENDIX H RECOMMENDED PROCEDURES FOR SIZING COMMERCIAL KITCHEN GREASE INTERCEPTORS This chapter covers the Appendix H requirements for commercial kitchen grease interceptors and Chapter 7 requirements for grease and garbage, sand-silt oil and silt-lint grease interceptors. Although Appendix I deals y specifically with private sewage disposal systems, the conditions and design requirements are the same in both sections of the UPC for commercial grease interceptors. Interceptors of these types have always been important in the functioning life of a private sewage disposal system. Public sewer systems also can benefit, and interceptors are being required by some sewer districts. This is especially true of commercial kitchens and industrial plant operations which discharge large amounts of grease, heavy oils or sand, such as metal finishing plants, commercial garages and repair shops or car washes. Even small amounts of grease, oil and solids from a number of sources can produce increased maintenance costs and deterioration of sewage or industrial waste collection systems. GREASE INTERCEPTORS A grease interceptor is sometimes called a grease-garbage interceptor when a waste disposal unit is installed in the waste line to the interceptor. Normally, the food waste disposal unit is not connected to the interceptor when the waste is discharged into a public sewer system. On the other hand, if a commercial waste disposal unit is to be used with a private sewage disposal system, it must discharge into a grease-garbage interceptor. The key word here is commercial waste disposal unit, rather than a domestic waste disposal unit, which a properly sized septic tank system can handle. Section H-1(a) "Waste discharge from fixtures and equipment in establishments which may contain grease, including but not limited to, scullery sinks, pot and pan sinks, dishwashing machines, soup kettles and floor drains located in areas where grease-containing materials may exist, may be drained into the sanitary waste through the interceptor when approved by the Administrative Authority." The use of the word may in this section might imply that the use of an interceptor is optional. The Code makes its clear in Sections 304(a) and 305(a) that such interceptors are necessary if there are sufficient amounts of these waste materials to cause damage to the sewer system or a private sewage disposal system. The purpose of the interceptor is to intercept the liquid greasy waste and/or garbage and retain it for a sufficient time to allow the greasy liquid to coagulate, and to allow the garbage to separate from the discharging liquid. Because a drop in temperature is necessary, it is a good practice to connect any other cold water or waste fixtures to the system to help reduce the water temperature in the interceptor. This might include bar sinks or ice machine drains. When possible, chemical sterilization rather than hot water should be used on dishes and utensils. Toilets, urinals, and similar fixtures should not be connected to the interceptor. Lavatories in public restrooms also should be excluded. LOCATION OF INTERCEPTORS Probably the most important feature for the successful operation of an interceptor is the maintenance program. Regardless of the size or design, an interceptor is only as good as its maintenance. For this reason the UPC requires any type interceptor be installed and located so that it will be easily accessible for v inspection, cleaning and removal of intercepted waste products. There must be an adequate number of manholes to permit access for cleaning all areas of the interceptor. At least one manhole should be located over the inlet, over the outlet, and one for each ten (10) feet of length between the inlet and outlet. In the F case of the silt-lint grease interceptors for laundries and self-service laundromats, the rock filter should be completely accessible. Manholes should not be less than twenty (20) inches in the least dimension. All manholes should be extended to grade with gastight construction. For ease of cleaning, the interceptor should be installed as near the grade surface as possible. The interceptor should be located near the source of the waste for the best protection of the piping system. A grease and/or garbage interceptor may not be located in any part of a building where food is handled or stored. A sand-silt-grease interceptor in large 489 t UPC ILLUSTRATED TRAINING MANUAL buildings is sometimes located inside a building near the point the waste enters the piping system. The interceptor should be located with proper clearances from the property line, water lines, building, etc. Appendix H does not specifically mention location. Generally, horizontal distances for septic tanks should be used for locating an interceptor. Appendix I, Section 1-9(b) specifies that interceptors coming under Appendix I are to be located according to Table 1-1. Table 1-1 has no category for interceptors, but it is logical to use distances for septic tanks as they serve a similar function. This is a reasonable approach, but can be modified by the local Administrative Authority when circumstances justify such action. DESIGN CONFIGURATIONS 1. Grease and/or Garbage Interceptors The UPC requires that these interceptors be of not less than two compartments with fittings designed for grease retention. The inlet, outlet, and compartment fitting should be of the septic tank tee type design with the vertical leg extending to within twelve (12) inches of the interceptor floor and extending well above the water level. The fitting should not be less than four (4) inches or the size of the building sewer, whichever is greater. The vent openings above the fittings allow the interceptor and sewer to vent back to the building vents, thus no vent is required on the outlet end of the interceptor. See Figure H-1. It is best to check with the local Administrative Authority for any local governing regulations because requirements may vary between various jurisdictions. Some jurisdictions may require a sampling box so an inspector can verify proper treatment or maintenance. 2. Sand-Silt-Oil Interceptors The UPC establishes no specific design configuration except for Section 708. Note that Section 708(c) requires that the interceptor have a 6 (six) inch minimum water seal trap and Section 708(d) requires a relief vent. If a part of the waste constituency is sand and silt, usually the individual floor drains, drainage trenches or other collecting means do not contain a trap due to the plugging by the sand. In these cases the interceptor must be trapped and vented to prevent sewer gases and odors from coming into the building through floor drains and similar fixtures. The vent is installed in the line from the interceptor to protect the trap seal. This is on the outlet side of the interceptor. See Figure H-2. In general, not less than two compartments should be used, similar to a grease interceptor. Usually the inlet fittings is a tee turned crosswise (horizontal) without any leg going into the liquid. When extending a line into the liquid, there is a tendency for sludge build-up which can cause a blockage. In this type of interceptor we are dealing with oils which are not greatly effected by the waste temperature. The minor disturbance of floating oil does not effect the retention ability of the interceptor. Access to this type of interceptor should be the same as for a grease interceptor. If the interceptor has a trap and vent on the outlet, it may not be necessary to have gastight covers if the intrusion of rain or storm water is not a problem. 3. Silt-Lint, Grease Interceptors For Laundries and Laundromats The UPC establishes no configurations for this type of interceptor. In general, to be effective this interceptor needs to have two or three settling compartments, a rock filter, and a final settling chamber. The rock filter is made up of clean ment should be extended three-quarter (3/4) inch rock. grade. A manhole should also be located overt complete compartment he inlet and outlet fittings and at least one in every compartment. s and automatic This interceptor need vented in a conventional tional man apped or vented ner.. All manholes cause floor nshoud be gastighta r standpipe risers are trapped a This interceptor is usually only used with a private sewage disposal system. Check the local Administrative Authority for local regulations. 490 SIZING GREASE INTERCEPTORS APPENDIX H SIZING GREASE-GARBAGE INTERCEPTORS i1.The formula for sizing can be found in Section H4, shown at the end of this chapter. The first step is to estimate the number of meals possible to serve during a peak hour of operation. If this figure cannot be obtained from the owners or from a similar operation, it can be estimated as follows: For restaurants, multiply the number of seats by 60 divided by the estimated time a patron takes to eat. A restaurant which serves people quickly may have a seating time from 30 minutes to 45 minutes. Another restaurant may be the type for leisurely meals with a seating time from 90 minutes to 120 minutes. In establishments such as rest homes, camp kitchens, the peak meals are equal to the occupant load. The waste flow rate varies with the type of kitchen equipment used. Storage factors help to provide space for storage of grease and/or garbage or other waste material and vary with the amount of loading. The loading is established by the hours per day of operation. A single service kitchen is one where the meals are served using disposable plates and utensils. Single service kitchens are usually not fully equipped. Cleanup is the only dishwashing involved, therefore the storage factor will be a"1," regardless of the hours of operation. EXAMPLES (a) A restaurant has seating for 125 patrons. Located next to a freeway, it operates 24 hours per day. Equipment includes a dishwasher and a waste disposal unit. It will use a private sewage disposal system. 1. Estimated meals served per peak hour: 125 x 60 - 45 minutes = 167 meals per peak hour 2. Waste flow rate: 6 gal. + 1 gal. = 7 gallons per meal 3. Retention time: 2.5 hours 4. Storage factor: 3 SOLUTION: 167 x 7 x 2.5 x 3 = 8768.5 gallon interceptor (b) A restaurant has seating for 125 patrons. It is designed for leisure dining and has a cocktail lounge. It operates 12 hours a day and equipment includes a dishwasher and a waste disposal unit. The property will be connected to a public sewer system. 1. Estimated meals served per peak hour: 125 x 60 - 90 minutes = 83.3 meals per peak hour 2. Waste flow rate: 6 gallons (waste disposal unit piped to bypass interceptor) 3. Retention time: 2.5 4. Storage factor: 2 (12 hours should be figured as 16 hours) SOLUTION: 83.3 x 6 x 2.5 x 2 =2499 gallon interceptor (c) A fast food chain establishment estimates it will serve 250 persons per peak hour including drive-through window. It has a single service kitchen, with no waste disposal unit. It operates 16 hours a day and has a private sewage disposal system. 1. Peak meals per hour: 250 2. Waste flow rate: 2 gallons 3. Retention time: 1.5 hours 4. Storage Factor: 1 (not a fully equipped kitchen) 491 .l i 9 UPC ILLUSTRATED TRAINING MANUAL SOLUTION: 250 x 2 x 1.5 x 1 =750 gallon interceptor NOTE: This is the minimum size permitted by the definition of grease interceptor in Chapter 1. (d) A rest home has 100 beds with 25 employees during any meal time, 3 meals per day. The kitchen is equipped with a dishwasher, waste disposal unit and will be connected to the public sewer. 1. Peak meals per hour: 125 2. Waste flow rate: 6 3. Retention time: 2.5 4. Storage factor: 2 (meals would be spread over 12 or more hours) SOLUTION: 125 x 6 x 2.5 x 2 = 3750 gallon interceptor Sand-Silt Oil Interceptors Refer to tables in Appendix I, Section 1-9. Also see Table 1-3. (e) A car wash can wash 25 cars per hour. The manufacturer states it takes 17 gallons to wash and rinse each car.The car wash is employee operated. 1. Cars per hour: 25 2. Waste flow rate: 17 gallons per car 3. Retention time: 2 hours 4. Storage factor: 2 SOLUTION: 25 x 17 x 2 x 2 = 1700 gallon interceptor (f) A manufacturing plant estimates it will use 3500 gallons to wash metal parts before painting. This will be over an 8 hour shift. What size interceptor should be used? The UPC does not specify requirements for this specific application although the formula may be adapted as follows: 1. 3500=8 =437.5 gallons per hour discharge 2. Retention time: 2 hours 3. Storage factor: 2 SOLUTION: 437.8 x 2 x 2= 1750 gallon interceptor 492 UPC ILLUSTRATED TRAINING MANUAL INSPECTION AND TESTING Inspection and testing should be the same as for septic tanks. Refer to Appendix I, Section 1-10 and the chapter on Appendix I in this book. H4 Sizing Criteria (from Appendix H of the UPC) (a) Parameters. The parameters for sizing a grease interceptor are hydraulic loading and grease storage P 9 9 P Y 9 9 9 capacity, for one or more fixtures. (b) Sizing Formula. The size of the interceptor shall be determined by the following formula: Number of meals Waste flow retention storage _ Interceptor size per peak hour' x rate2 x time3 X factor4 — (liquid capacity) 1 Meals Served at Peak Hour 2 Waste Flow Rate a. With dishwashing machine................................................................................................6 gallon flow b. Without dishwashing machine...........................................................................................5 gallon flow c. Single service kitchen........................................................................................................2 gallon flow d. Food waste disposer.........................................................................................................1 gallon flow 3 Retention times Commercial kitchen waste Dishwasher................................................................................................................................2.5 hours Single service kitchen Singleserving.............................................................................................................................1.5 hours 4 Storage Factors Fully equipped commercial kitchen.............................................................................8 hour operation: 1 ..................................................................................................................................16 hour operation:2 ..................................................................................................................................24 hour operation:3 SingleService Kitchen.........................................................................................................................1.5 494 MASON COUNTY *t e < ini '» ' s y � ou - Permit No. U ownew ��, Contractor �_ Job Description 1 ` Inspection Bg Approved for Cover /1—0 —9 _ _ _ Date Remarks Applicant Must Call _ I"ued By Post this card in a conspicuous plac: for Required Inspection at Front of Premises 1 a 311-77s-- ono 0 -OUNTY Mechan 'ical P rlhIits N��Q�C-Y- Da �_— ,P 4 • qc- On Contractor Job DescripVnii , �• - 9"—Sk—tAG— InSPBOWE - — �B;)r I ru -Appro for Cover I �- �D--9 �_— ' Date Remarks �;�� — ,l i rant Must Call y�7-9670 - � , Issied By Post this card in a cor--)icl'' For Regi,; - at Front MASON COUNTY DEPARTMENT of GENERAL SERVICES Mason County Bldg. III 426 W.Cedar P.O.Box 186 Shelton,Washington 98584 (360)427-9670 BUILDING PARKS& RECREATION FAIR/CONVENTION CENTER ADMINISTRATION December 2 , 1996 Prince of Peace Catholic Church NE 1171 Sand Hill Road Belfair, Washington MIS95-0914 FINAL INSPECTION OF MECHANICAL AND PLUMBING To. Don Hochause Gloria Lincoln Joseph Testu Enclosed please find the final inspection for the above permit . If you have any questions, please contact me at the Mason County Building Department . Thank you. Sincerely, Mike Byrne, uilding Official Page No. 1 CASE HISTORY FOR CASE NO.: MIS95-0914 PRINCE OF PEACE CATHOLIC NE1171 SAND HILL RD BELFAIR 12/02/96 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MISA010 Application received / / / / 11/21/95 11/21/95 KW MISA050 Approved For Issuance / / / / 12/18/95 DONE KS 12/18/95 KS MISA500 (F) Issue permit / / / / 12/18/95 DONE KS 12/18/95 KS MISA900 Telephone call / / / / 07/19/96 recived call from prince of peace of DONE SKM 07/19/96 SKM church asking about the requirment of the floor sink and the grease trap why, where, and how come and I advised them to get a code book and see what the book requires . MISB009 Fire Marshal Review 12/15/95 / / 12/18/95 see conditions. DONE DLS 12/18/95 DLS MISB110 Structural Plan Review 11/21/95 / / / / need more information PEND DH 12/15/95 DWH MISE110 Structural Plan Review 12/15/95 / / 12/15/95 not approved for LPG. Electric only. DONE DH 12/15/95 DWH MISB128 Addressing / / / / 11/21/95 DONE GMM 11/21/95 GMM MISB130 Planning Review 11/21/95 / / 11/21/95 DONE AHB 11/21/95 AHB MISB131 Environmental Health Review 12/18/95 / / 12/18/95 They need to become a certified kitchen DONE PSD 07/19/96 SKM priot to serving food to the public.psd MISB135 RLC Checklist Review / / / / 11/21/95 N/A AHB 11/21/95 AHB MISC050 Pre-site Inspection 06/26/96 06/27/96 06/27/96 see h:\wp\pop file for report. DONE SKM 07/19/96 SKM copy has been given to Mike Byrne and Dave Salzer. MISC050 Pre-site Inspection 07/05/96 / / / / SENT REPORT TO APPLICANT SENT SKM 07/05/96 SKM JOESEPH TESTIS / CO PRINCE OF PEACE CHURCH 1171 SAND HILL RD BELFAIR, WA. MISC130 Plumbing inspection 07/10/96 07/11/96 11/25/96 1. ON THE 3 COMPARTMENT FOOD PREP SINK DONE MJB 12/02/96 MJB THE DRAIN OFF THE BOTTOM NEEDS TO BE TO AN INDIRECT WASTE. 2. THERE NEEDS TO BE A GREASE TRAP TANK INTERCEPTOR, I SPOKE WITH JOB TESTO HE STATES THERE IS ONE INSTALLED ON THE EXTERIOR OF THE BUILDING AND IT WAS INSPECTED BY THE HEALTH DEPT. 3. ON THE HAND WASH SINK A STANDARD P TRAP FITTING NEEDS TO BE USED. 4. ON THE 2 DISH WASHER DRAINS CENTER THE PIPES OVER THE INDIRECT WAST FLOOR SINK AND LEVEL A 1 INCH GAP BETWEEN THE TERMINATION ON THE PIPE AND THE TOP OF THE FLOOR SINK. Completed..Site inspection..11-25-96 mjb Page No. 2 CASE HISTORY FOR CASE NO.: MIS95-0914 PRINCE OF PEACE CATHOLIC NE1171 SAND HILL RD BELFAIR 12/02/96 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By MISC135 Mechanical inspection 07/17/96 07/19/96 11/25/96 1. Mechanical portion of kitchen is as DONE MJB 11/25/96 MJB per code.EXCEPT FOR THE EXHAUST OF THE P i KITCHEN FAN , WHICH WILL NEED TO BE APPROVED BY THE BUILDING OFFICAL. 2. Fan specs show that the fan cfm is above 1500cfm and less than 2500cfm which is acceptable. 3. Will still need specs on the liquid tight sealer that is used on the hood to duct connection instead of the welded joint that the UMC calls for at this conection point. ---------------------------------------- ----------------- THEY HAVE SUBMITTED A SET OF PLANS TO SHOW WHAT IS ACTUALY IN PLACE IN THE KITCHEN, and they are being sent to the file, and attached to the hard card. FINALED PER SITE INSPECTION 11-12-96. ANY REMODELING OF KITCHEN WILL REQUIRE DUCT WORK TO MEET MECHANICAL CODE. MJB 11-25-96 MISC155 Final inspection 11/22/96 11/25/96 11/25/96 DONE MJB 12/02/96 MJB 1 MASON COUNTY DEPARTMENT of GENERAL SERVICES Mason County Bldg. III 426 W.Cedar P.O.Box 186 Shelton,Washington 98584 (360)427-9670 BUILDING PARKS& RECREATION FAIR/CONVENTION CENTER ADMINISTRATION October 17, 1996 Don Hochause P.O. Box 482 Grapeview, Washington 98546 Re : Prince of Peace Catholic Church NE 1171 Sandhill Road Belfair, Washington MIS95-0914 MECHANICAL PERMIT Dear' Don, The current status of the above permit indicates that a final has not been completed. The exhaust for the kitchen fan does not specifically meet the 1994 Uniform Mechanical Code on the outside of the structure, however the installation will allow temporary use until I can meet with the installer and discuss an alternative method that will meet the intent of the code . I have discussed a meeting time with Mark Lincoln, and we are prepared to visit the site and discuss the issue. The facility may be used until we resolve the issue of an alternative extension of the exhaust . Please contact me at (360) 427-9670, if you need and additional information. Sincerely, Mike Byrne, Building Official Permit No. M 566-Oil MASON COUNTY PLUMBING/MECHANICAL PERMIT APPLICATION 426 W. Cedar/P.O. Box 186, Shelton, WA 98584. 427-9670 PLEASE PRINT . C / c', #1 wner 01r 4� '1�� ����"� Phone# S� 7 Z 7J SOS ddress WE 1111 SA140 4i4 QOP40 I46)!� i y St WR Zip38520 Directions to Job Site g%d"Ay 3a0 Wts t); jpzrAie. Ridarow Sf4wo 1 OAO 1 M%Le OLI Lt W LL ttC*JrWrAgy SC1400L Owner Mailing Address SArNE City St Zip Lien/Title Holder Address City St Zip #2 Co tractor Name Contractor Reg. # Address Expiration date City St Zip Phone Parcel No.12 3 _ '� LQ 7. ` .S'0CY)'6 I Legal Description S t LTI 0 W #4 Use of building e14VQC Describe work.1 N 1rA4j Z S 1 1111446 COirlvevrlou OV LSW N/AS*& #5 Type of Job: New 14 Add AR M I h ni I Fixtures 6 each P umbin� Fixtures�$3 each F�e ec D a to es No._Toilets NOV 16 CIRCLE FUEL TYPE: Electric _Bath Basins Heatpump, Other Bath Tubs SER No. nit Fees Showers VICES _ Furn BTU _Hot Water Htr _ Heatpumps _Laundry Washer _ Vent Systems Sinks 6 _ Spot Vent Fans _Floor Drains No. Boilers/Compressors Laundry Basins HP Dishwasher 3 No.. Air Handling Units _Disposal _ cfm# Urinals No. Other _Other Gas Outlets Wood, Gas, Pellet Stove �5O Permit Basic Fee 15.00 C'OOV44 01� OVl� TOTAL PLUMBING ` $ ' %P.� go-2d Permit Basic Fee 15.00 TOTAL MECHANICAL $,01 — No Basic Fee for Wood, Gas, Pellet Stove NOTICE: This permit becomes null and void if work or construction authorized is not commenced • within 180 days or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced. Proof of continuation of work is by means of a progress inspection. NOTE: If this permit application includes the placement of a fuel tank, heat pump or other unit to be located outside of the existing structures, a plot plan MUST be submitted as required below: Show following on the site plan below: Lot Dimensions, Existing Structures, Structure Setbacks, Water Lines, Septic Systems, Flood Zones, Wells, Shorelines, Easements, Name of Flanking & Fronting Streets. Indicate directional by N, S,10 E, W, etc. OWNERS AFFIDAVIT CONTRACTORS AFFIDAVIT I CERTIFY THAT I AM EXEMPT FROM THE REQUIREMENTS OF I CERTIFY THAT I AM A CURRENTLY REGISTERED CONTRAC- THE CONTRACTORS REGISTRATION LAW RCW 18.27,AND AM TOR IN THE STATE OF WASHINGTON AND I AM AWARE OF THE AWAREOFTHE MASON COUNTYORDINANCE REQUIREMENTS ORDINANCE REQUIREMENTS REGULATING THE WORK FOR FOR WHICH THIS PERMIT IS ISSUED AND THAT ALL WORK H THE.PEF3 T IS ISSUED AND ALL WORK DONE WILL BE IN DONE WILL BE IN CONFORMANCE THEREWITH. NO CHANGES NF(3RMAIVC HEREWITH. NO CHANGES SHALL BE MADE SHALLBE MADE WITHOUT FIRST OBTAINING APPROVAL FROM WITHOUT FIRST OBTAINING APPROVAL FROM THE BUILDING THE BUILDING DEPARTMENT. DEPARTMENT. X OWNE X BY DATE `� DATE Return permit to: Department of General Services 426 W. Cedar/P.O. Box 186, Shelton, WA 98584 • 427-9670/1-800-562-5628 FOR OFFICIAL USE ONLY: b Accepted : Date: p Y Receipt No. Referred To DEPARTMENTAL REVIEW W jr,fk"4 CkAW cV, 0) Ords-_"iFOR OFFICIAL USE ONLY Proposal Proposal j,?_ -�04 Approved Denied Planning: Building: X0AQQPzUM R)P_ L?6 &j,=G Dvoh/ Fire Marshal: ""�� \ ks l t � Page No. 1 CASE HISTORY F&R CASE NO.: MIS95-0914 PRINCE OF PEACE CATHOLIC NE1171 SAND HILL RD BELFAIR t 07/11/96 Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd Code Sent Done Done Date By ------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- --- MISA010 Application received / / / / 11/21/95 11/21/95 KW MISA050 Approved For Issuance / / / / 12/18/95 DONE KS 12/18/95 KS MISA500 (F) Issue permit / / / / 12/18/95 DONE KS 12/18/95 KS MISB009 Fire Marshal Review 12/15/95 / / 12/18/95 see conditions. DONE DLS 12/18/95 DLS MISB110 Structural Plan Review 11/21/95 / / / / need more information PEND DH 12/15/95 DWH MISB110 Structural Plan Review 12/15/95 / / 12/15/95 not approved for LPG. Electric only. DONE DH 12/15/95 DWH MISB128 Addressing / / / / 11/21/95 DONE GMM 11/21/95 GMM MISB130 Planning Review 11/21/95 / / 11/21/95 DONE AHB 11/21/95 AHB MISB131 Environmental Health Review 12/18/95 / / 12/18/95 They need to become a certified kitchen DONE PSD 12/18/95 DPB priot to serving food to the public.psd MISB135 RLC Checklist Review / / / / 11/21/95 N/A AHB 11/21/95 AHB MISCO50 Pre-site Inspection 06/26/96 06/27/96 06/27/96 see h:\wp/pop file for report. DONE SKM 07/03/96 SKM copy has been given to Mike Byrne and Dave Salzer. MISC050 Pre-site Inspection 07/05/96 / / / / SENT REPORT TO APPLICANT SENT SKM 07/05/96 SKM JOESEPH TESTIE / CO PRINCE OF PEACE CHURCH 1171 SAND HILL RD BELFAIR, WA. MISC130 Plumbing inspection 07/10/96 07/11/96 07/11/96 1. ON THE 3 COMPARTMENT FOOD PREP SINK FAIL LW 07/11/96 LAW ,rf THE DRAIN OFF THE BOTTOM NEEDS TO BE TO I V C��� V AN INDIRECT WASTE. �PCK.e d 2�Tt� E: _-2. THERE NEEDS TO BE A GREASE TRAP TANK s y INTERCEPTOR, I SPOKE WITH JOE TESTO HE{mod v ��/ STATES THERE IS ONE INSTALLED ON THE EXTERIOR OF THE BUILDING AND IT WAS INSPECTED BY THE HEALTH DEPT. S eG• 3. ON THE HAND WASH SINK A STANDARD Pr 7�i. Gl�aS"� rGf7l� TRAP FITTING NEEDS TO BE USED. CleGk ON THE 2 DISH WASHER DRAINS CENTER THE PIPES OVER THE INDIRECT WAST FLOOR • SINK AND LEVEL A 1 INCH GAP BETWEEN THE V' THE FLOOR SINK. 1 MIS95-0914 DATE OF INSPECTION 6/27/96 PRINCE OF PEACE CATHOLIC CHURCH PRE-CONSTRUCTION INSPECTION COMMERCIAL KITCHEN PRE CONSTRUCTION INSPECTION �. Scope of project : Install convection oven and counter top gas O stove, dishwasher. Code sections referenced in report are from 1994 UBC, 1994 UMC, and 1991 UPC. At the time of inspection 6/27/96 there was a 16ga. stainless steel kitchen hood mounted at aprox. 18" from the ceiling at the closest point, and mounted directly to the back wall . the hood was suspended with noncombustible hanger brackets and secured to the ceiling framing . SECTION 505 . 7 UMC REQUIRES THAT HOODS BE MOUNTED WITH THE SAME CLEARANCE TO COMBUSTIBLES AS THAT REQUIRED FOR GREASE DUCTS SYSTEMS . J There is also a 16ga. stainless steel grease duct extending � from the top of the hood to the exterior of the building and terminating horizontialy through the exterior wall to a point 91above grade at its lowest point, aprox. 5' from an exterior fire door opening to the kitchen. SECTION 507 . 11 UMC REQUIRES EXHAUST OUTLETS FOR GREASE DUCTS SERVING COMMERCIAL FOOD HEAT-FOOD PROCESSING EQUIPMENT SHALL EXTEND THROUGH THE ROOF UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICAL. SUCH EXHAUST SHALL BE AT LEAST 2 ' ABOVE THE ROOF SURFACE, AT LEAST 10' FROM PARTS OF THE SAME OR CONTINUOUS BULDINGS, ADJACENT PROPERTY LINE OR AIR INTAKE OPENING INTO ANY BUILDING, AND SHALL BE LOCATED AT LEAST 10' ABOVE THE ADJOINING GRADE LEVEL. \3 . The grease duct passes through the kitchen side wall, and is protected by a 5/8 wrap of type X gwb elevated with 26ga. sheet metal saddle to provide the required 3" clearance . SECTION 507 . 6 UMC REQUIRES THAT THE DUCT ENCLOSURE BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATIONAND VENTED TO THE EXTERIOR THROUGH WEATHER -PROTECTED OPENINGS . THE ENCLOSURE SHALL BE SEPERATED FROM THE DUCT BY AT LEAST 3" AND NOT MORE 12" AND SHALL SERVE A SINGLE GREASE DUCT EXHAUST DUCT SYSTEM. G`C -4 . The fan provided to service the hood is a 3/4 hp rated at 1350 rpms, the factory specs were not at the site at the time of inspection the contractor will provide them for verifacation ' of the required minimun and maximun air velocity. �+ SECTION 507 . 8 UPC REQUIRES THAT GREASE DUCT SYSTEMS SERVING A TYPE 1 HOOD SHALL BE DESIGNED AND INSTALLES IN A MANNER TO PROVIED AN AIR VELOCITH WITHIN THE DUCT SYSTEM OF NOT LESS v� THAN 1, 500 FEET PER MINUTE AND NOT TO EXCEED 2 , 500 FEET PER MINUTE. 5 . During the pre-site inspection the requirment for make up-air was not addressed but will need to be provided. SECTION 402 .4 UMC REQUIRES EACH COMMERCIAL KITCHEN SPACE PROVIDED WITH AN EXHAUST SYSTEM SHALL HAVE AIR SUPPLIED TO THE ROOM EQUAL TO THE AMOUNT OF AIR TO BE EXHAUSTED. MAKE UP DIFFUSERS SHALL BE LOCATED TO PREVENT A SHORT-CIRCUITING OF AIR FURNISHED TO THE EXHAUST SYSTEM. WINDOWS AND DOORS SHALL NOT BE USED FOR THE PURPOSE OF PROVIDING MAKEUP AIR. THE EXHAUST AND MAKE UP-AIR SYSTEM SHALL BE CONNECTEED BY AN ELECTRIC INTERLOCKING SWITCH. COMPENSATING HOOODS SHALL MEET THE AIR FLOW REQUIRMENTS SPECIFIED IN SECTIONS 508 . 7 . 2 THROUGH 508 . 7 .4 . COMPENSATING HOODS SHALL EXTRACT AT LEAST 20 PERCENT OF THEIR REQUIRED EXHAUST AIRFLOW FROM THE KITCHEN AREA. ------------------------------------------------------------------- 6 . APPROPRIATE PERMITS AND PLANS WILL BE REQUIRED FOR THE PROJECT AS SPECIFIED IN SECTION 106 UBC , SECTION 112 UMC , AND SECTION 30 . 2 UPC. ------------------------------------------------------------------- 7 . PLUMBING REQUIRMENTS AS PER 1991 UPC. DETAILS FROM THE ILLUSTRATED HANDBOOK ARE ATTACHED skm H: \wP\PoP