HomeMy WebLinkAboutMIS93-0804 Cancelled Woodstove - MIS Permit / Conditions - 7/4/1994 MASON COUNTY
Mason County Bldg, III 426 W. Cedar
P.O, Box 186 Shelton, Washington 98584
M'xSCEE L EANE0l.! 5 1,. i-_ 14M -. a ! _ 1 ,
MIS93-0804 PAP, ! 1 l.� i.'t�1l��:si. ! l. I,( AI
I(01i ANIIRI ; ; - NV II HII.1.. RD t3FLFA.IR
AfJ I ! !. AN1 TIM DOUA 1761-6698
10.IN' 1< I IN DODA 21S —0690
I I l,Al f1 III-11 IF tilt NE 1 11111 Ili It 1 If 5PI1451 IS W14.3I-14 It $611 PERMIT
1 if' 1 14 '&R) r I ; uN VOID RY EXPIRATION
WOOD'S rOVF.
N LL=_BY
DATE
MORTII FROM t3E L FA I R ON OLD HL l FAIR HWY APPROX l . f, MI I f '� 1 URN R I611 t ON Nl WK I RK ifP H It.l I'll
RIVf:RHILL TURN LFFC FOLLOW AROUND CURVE . 10 Sl HANK OF MAILBOXES NF Iiiit RD 1URN IFf1 -- IIS 1HF
3RO 140USE ON LEFT . FOLLOW RAINES AUTO RfPAIR SIGH'i 'itARI IN& ON 011I 14FIFAIR HWf AND NFWKIRK
I>t;rl.1FCI N 0 1 L
I Y P i AM 11N ( k
,
AI fir. !4!
CONCRETE MECHANICAL MOBILE HOME
Footings-Setback date by Ribbons
date by Gas Piping date b
Foundation Walls date by Set Up
date by INSULATION date by
BG/SLAB Insulation Floors Final
date by date by date by
FRAMING Walls FIRE DEPT.
date by date by date by
PLUMBING OTHER
Groundwork Attic
date by date by
D.W.V. WALLBOARD NAILING
date by date by
Water Line FINAL INSPECTION
date by date by date by
Page No. 2 CASE HISTORY FOR CASE NO.; BLD93-1449
TIN DODA
NE71 HILL RD BELFAIR
11/15/95
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDC155 Final inspection 01/26/94 01/27/94 01/27/94 CORRECTIONS FAIL LW 01/27/94 LAW
1. PROVIDE A DUCT EXTENTION OFF THE
BOTTOM OF THE COMBUSTION AIR OPENING FOR
THE WOODSTOVE. EXTEND 3 INCHES BELOW THE
INULATION.
2. INSULATE WATER LINES IN CRAWL SPACE.
1�4INSULATE DUCT IN ATTIC
SEAL AROUND TOILET BASES AND SHOWER
STALL
Page No. 1 CASE HISTORY FOR CASE NO.; BLD93-1449
TIM DODA
NE71 HILL RD BELFAIR
11/15/95
Action Description Req/ Schd/ End/ Action Notes Disp By Update Upd
Code Sent Done Done Date By
------- ------------------------------ -------- -------- -------- --------------------------------------- ---- --- -------- ---
BLDA010 Application received / / / / 09/14/93 09/14/93 KW
BLDA100 Approved For Issuance / / / / 10/19/93 DONE KS 10/19/93 KS
BLDA100 Approved For Issuance / / / / 10/19/93 DONE KS 10/19/93 KS
BLDA500 (F) Issue building permit / / / / 10/22/93 DONE KS 10/22/93 KS
BLDA920 Miscellaneous action / / / / 12/08/95 SENT INSPECTION NOTICE, EXTEND BY 12-8 CS 11/08/95 CMS
BLDB110 Structural Plan Review 09/20/93 / / 10/18/93 DONE WLC 10/18/93 WLC
BLDB129 Sent to Planning / / / / 09/17/93 SENT MMT 09/17/93 MMT
BLDB130 Planning Review 09/20/93 / / 09/20/93 DONE MMS 09/20/93 MMS
BLDB135 Addressing / / / / 09/14/93 DONE GMM 09/14/93 GMM
BLDB200 Environmental Health Review 10/18/93 / / 09/17/93 Sent letter with requirements HOLD MMT 10/18/93 WLC
TO MARK FOR REVIEW
BLDB200 Environmental Health Review 10/18/93 / / 10/18/93 NEED TO SIGN OFF PERMIT IN STRUCTURAL AT DONE MMT 10/18/93 MMT
TIME OF REVIEW.
created records—septic system appears
to be adequately sized of the number of
bedrooms and soil type
Per Carolyn's review
BLDC110 Footing inspection 10/28/93 / / 10/28/93 1) Roto & stub steel into existing FAIL DLF 10/28/93 DF
footing (bend & lap)
2) Splices to be a min. of 15"
3) At step bend & lap steel stay 3" off
grade
4) Spec'd steel req's for 2' to 3 11 7/8
& 4' to 5 11 7/8
BLDC110 Footing inspection 11/04/93 11/04/93 11/04/93 PASS LW 11/12/93 CKR
BLDC115 Foundation wall inspection 11/09/93 11/09/93 11/09/93 PASS DH 11/12/93 CKR
BLDC125 Framing inspection 12/21/93 12/22/93 12/22/93 CORRECTIONS FAIL LW 12/27/93 LAW
1. REMOVE ROOFING IN ATTIC SPACE
2. PROVIDE H CLIPS EVERY OTHER TRUSS
3. WHEN SHEET ROCHING NAIL OFF 7 INCHES
O.C. WITH A MINIMUM OF 6d NAILS FOR
SHEAR
4. NAIL ALL FLOOR JOISTS TO DOUBLE TOP
PLATE WITH 2-16d NAILS
5. THE GLB'S DO NOT LINE UP WITH THE
EXISTING FOUNDATION. AT THE ENDS OF THE
BEAMS ON THE INTERIOR PROVIDE A 24X24X12
CONCRETE PAD WITH A POST UNDER THE LARGE
GLB AND A 18X18X9 CONCRETE PAD AND POST
UNDER THE SMALLER BEAM
BLDC125 Framing inspection 12/29/93 12/30/93 12/30/93 PASS LW 01/03/94 LAW
BLDC130 Plumbing inspection 12/20/93 12/21/93 12/21/93 PASS DH 12/22/93 CKR
BLDC135 Mechanical inspection 12/29/93 12/30/93 12/30/93 PASS LW 01/03/94 LAW
BLDC145 Insulation inspection 12/30/93 12/30/93 12/30/93 PASS LW 01/06/94 LAW
BLDC150 Wallboard inspection 01/05/94 01/06/94 01/06/94 PASS LW 01/06/94 LAW
Permit No.
MASON COUNTY
BUILDING PERMIT APPLICATION q
426 W. Cedar/P.O. Box 186, Shelton, WA 98584 427-9670/1-800-562-5628 �ID�
PLEASE PRINT .y�
#1 Owner Phone# Z-U(o -7-S-- b ( c1 6
Site Ad ss Fire District#
City St zip 2S�
Directions to Jog Site _
Owner Mailing A ess °C-
it St Zip
Lien/Title Holder
Address
Clty St Zip
#2 Contractor Na e Ld, Contractor Reg# 1VQlp T IV, 4�4D7_
Address P� Expiration Date
City St Zip ,' Phone# 0
#3 If septic is located on project site, includ re rds
Connect to Septic? Public Wat u ply
Connect to Sewer System? N me f S st
(If residential, proof of potable water is require )
#4 Parcel No.r -,)0 -0� /'
Legal Description o of i �AI WI O �� NWy�
y� cvj wa44.
#5 Building Square Footag (existing/proposed)
1 st FI 4eln / 2nd FI --/ 3rd FI -/ Loft
Basement / Deck / #bedrooms / #bathrooms /
Garage / Carport / (Circle:Attached or Detached?)
Other sq. ft. /
#6 Use of building Describe work '
#7 Type of Job: New Add v-" Alt Repai1h"
#8 MOBILE/MAN ACTU ED HOME INFORMATION
DEC 2 7 1995
Model Year ake Model
Length Wi Serial No. GENERAL SERVICES
#Bedrooms # ooms Type of Heat
Purchase Price
#9 Indicate by circling the applicable source if any water is on or adjacent to subject property:
River Pond Creek Stream Wetland Lake Marsh Saltwater Seasonal Runoff Other
Show following on the site plan
Lot Dimensions Flood Zones
Existing Structures Fences
Structure Setbacks Driveways
Water Lines Shorelines
Drainage Plan Topography
Septic Systems Wells
Proposed Improvements Easements
Name of Flanking Street Indicate Directional by (N, S, E, W)
Name of Fronting Street in relation to plot plan
APPLICANT TO DRAW SITE PLAN BELOW
APPLICANT TO DRAW TOPOGRAPHY PROFILE BELOW
Plumbing Fixtures ($3 each) Fee Mechanical Fixtures ($6 each)
No. Toilets CIRCLE FUEL TYPE: Gas, Electric,
Bath Basins Heatpump, Other
Bath Tubs No. Units Fees
Showers Furn BTU
Hot Water Htr Heatpumps
_Laundry Washer _ Vent Systems
Sinks _ Spot Vent Fans
_Floor Drains No. Boilers/Compressors
_Laundry Basins HP
Dishwasher No. Air Handling Units
_Disposal cfm#
Urinals No. Fire Protection Systems
Other _ Auto. Fire Alarm Sys 50.00
Fixed Fire Supp. Sys 50.00
Permit Basic Fee 15.00 Auto Fire Sprink Sys 25.00
TOTAL PLUMBING $ No. Other
Gas Outlets
Wood, Gas, Pellet Stove
NOTICE: THIS PERMIT BECOMES NULL AND VOID IF
WORK OR CONSTRUCTION AUTHORIZED IS NOT COM-
MENCED WITHIN 180 DAYS OR IF CONSTRUCTION OR Permit Basic Fee 15.00
WORK IS SUSPENDED OR ABANDONED FOR A PERIOD
OF 180 DAYS AT ANY TIME AFTER WORK IS COM-
MENCED. PROOF OF CONTINUATION OF WORK IS BY
MEANS OF A PROGRESS INSPECTION.
OWNERS AFFIDtVIT CONTRACTORS AFFIDAVIT
I CERTIFY THAT I AM EXEMPT FROM THE REQUIRE- I CERTIFY THAT I AM A CURRENTLY REGISTERED
MENTS OF THE CONTRACTORS REGISTRATION LAW CONTRACTOR IN THE STATE OF WASHINGTON AND I
RCW 18.27, AND AM AWARE OF THE MASON COUNTY AM AWARE OF THE ORDINANCE REQUIREMENTS REGU-
ORDINANCE REQUIREMENTS FOR WHICH THIS PER- LATING THE WORK FOR WHICH THE PERMIT IS ISSUED
MIT IS ISSUED AND THAT ALL WORK DONE WILL BE IN AND ALL WORK DONE WILL BE IN CONFORMANCE
CONFOR CE THEREWITH. CHANGES SHALL BE THEREWITH. NO CHANGES SHALL BE MADE WITHOUT
MADE H T FIR TA I APPROVAL FROM FIRST OBTAINING APPROVAL FROM THE BUILDING
THE BU LDI DEPA TM NT DEPARTMENT.
X OWN Z X BY
DATE I _ i-3 DATE
FOR OFFICIAL USE ONLY: Accepted by: �"" Date: `2 9
1
DEPARTMENTAL REVIEW
FOR OFFICE USE ONLY
Approved Cond. Hold
Approval
Planning:
Environmental Health:
Building Plan Review
Occupancy Group: Type of Const:
Fire Marshal:
Other:
Special Conditions: FEES
Building Permit
Plan Check
Plumbing Fee
Mechanical Fee
Wood/Gas/Pellet Stove
Radon Monitor
Violation Fee
Site Inspection
Building State Fee
Other
Other
Building Valuation: TOTAL FEE a.� .
r
aa oo
ova
Gel a �v�, �g� 1 s �-, _ 3
.3 g, .� i
t
Ash �►r y�y '" .
t:va t:, N rlI F APB
i