Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FIR2006-00003 Final - FIR Permit / Conditions - 5/11/2006
1/2008 Case Activity Listing 3/1 35AM 9:13:35AM ( Case#: FIR2006-00003 tT Assigned Done Activity Description Date t Date 2 Date 3 Hold Disp To By Updated Updated By FIRA010 Application Received 1/25/2006 1/25/2006 None DONE KS 1/25/2006 KS FIRA200 Inspection 3/21/2006 3/16/2006 None PASS CJH CJH 3/21/2006 CJH Hydro test initiated on 03-14-06 by Fox Fire Prevention and noted on 03-15-06(0,1840 with 212 PSIG at the lower level piping located directly above the riser location.An extensive visual inspection of all heads and plugs noted(1)lower level plug with a miniscule seepage,less than one drop per minute,that will be replaced with a pipe and head after installaton of the lower level dropped ceiling. On 03-16-06 @ 0830 noted 205 PSIG FIRA100 Fire Marshal Review 1/25/2006 7/28/2006 None DONE LAW 7/28/2006 LAW System already installed and inspected by fire marshal. FIRA40 Approved for Issuance 7/31/2006 7/31/2006 None DONE CMH 7/31/2006 CMH FIRA230 Miscellaneous Action 8/1/2006 8/l/2006 None DONE KS 8/l/2006 KS SENT TO BELFAIR 8/l/06 KS FIRA20 Issue Permit 8/7/2006 None DONE KKK 8/7/2006 KKK FIJW5 Print Inspection Card 8/7/2006 None DONE KKK 8/7/2006 KKK FIRA950 LTR-Notice Final Inspection 11/30/2007 None DONE LAW 11/30/2007 LAW FIRA30 Reprint Permit 3/11/2008 None DONE PIB 3/11/2008 PIB Reprinted for Fire Marshal. Page 1 of 1 CaseActivity:spt MASON COL.Aaf :; T. OF COMMUNITY DEVELUPI`S ENT inspection Line(360)427-7262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352 Shelton,WA 98584 FIRE PROTECTION PERMIT FIR2006-00003 APPLICANT: EARL LINCOLN RECEIVED: 1/25/2006 CONTRACTOR: FOX FIRE PREVENTION (360) 871-1985 LICENSE: FOXFIP1127M8 EXP: ISSUED: 8/7/2006 SITE ADDRESS: 23552 NE STATE ROUTE 3 BELFAIR EXPIRES: 2/7/2007 PARCEL NUMBER: 123294390173 LEGAL DESCRIPTION: TR 17-B OF SW SE LOT: 3 OF SP#1852 PROJECT DESCRIPTION: GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood& Duct?: N Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: N Zones: Heat Detectors: Wet Chemical?: N Sprinkler?: Y Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: First Floor: Type Amount Due Amount Paid Monitoring Phone No.:()- Second Floor: Auto Fire Alarm?: Third Floor;: Sprinkler System Permit $906.35 $906.35 Sprinkler System Plan $589.13 $589.13 Fire Re-Inspection $68.00 $68.00 Total: $1,563.48 $1,563.48 FIR2006-00003 Please refer to the following pages for conditions of this permit. 1 of 3 CASE NOTES FIR2006-00003 CONDITIONS FOR FIR2006-00003 1.) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF OWNER/CONTRACTOR FAILS TOP T ADD ESS N SITE � R TO REQUESTING INSPECTIONS. 2.) Ttjtsprinkler sytem must m e requirements of NFPA 13 2002 edition. This permit becomes null and void if work or construction authorized is not commenced within 180 days,cr if construction or work is suspended fora period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The nerorthe agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the above described property and ture for re and i ection. OWNER OR AGENT DATE' b �6 RECEIVED AUG 212005 426 W. CEDAR ST. � ,Cf Au G 2006 0 FIR2006-00003 Please refer to the following pages for conditions of this permit. 2 of 3 -n CONCRETE MECHANICAL MANUFACTURED HOME z C) Date By O Footings 'Setbacks Gas Piping Ribbons (7) O r- C) interior Dale ay interior-Date By Date By z C) Exterior Date By Exterior-Date By C) Set-up M CD INSULATION > Point Load I Isolated Footings Date By ;0 [--)ate R BG�SLAB INSULATION Dato By E FIRE DE PA Foundation Walls Floors Date By Bate By Data By DECKS FRAMING Walls Date By Date. By mate By PROPANE TANKS PLUMBING Vault Date By Date By OTHER Groundwork Attic Dato By Date By Type- Date 13Y D,W.V DRYWALL Type: Int.Brace Wall Date By CD Date By FINAL INSPECTION CD Water Line Fire Seperation CD Date By Date By Ddzu y CD o Pass or Request Inspect. C)C) Type of Insp. Fail I Date Date Doge-By, Comments C) (D 0 g L 0 OAlv4SS V_ A)A-L, 0 0 0 Q. (D 3 0 w -n r 55 CONCRETE MECHANICAL MANUFACTURED HOME OFootings I Setbacks Date B} Ribbons � Gas Piping I ; Interior Date By Interior-Date By Dato By CD Exterior Date By Exterior-Date By Set-up W INSULATION Point Load I Isolated Footings Date By BG I SLAB INSULATION Date By Data By FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING walls Date By Date By,, Data By PROPANE TANKS PLUMBING Vault date By Date BY OTHER Groundwork Attic l�OW By Type- Date B y Date By n.Vv.V DRYWALL Type_ Int Brace v t II Date Rn. Date By Date By SY . FINAL INSPEC11ON 0 water Line Fire Seperation Date By Date By Date By fD , o. o Pass or Request Inspect Type of Insp. Fail Date Date Done By Comments w c F,Rg sAR,N�c� �y TG t,5 ; _a6 �� a >v 0 0 0 F o 0 ; U) �} p �t Fi t fff r; O rJJ f Mason County Dept. of Community Development Mason County Bldg. III, 426 W. Cedar, P.O. Box 186, Shelton, WA 98584 Shelton: (360) 427-9670 Belfair: (360) 275-4467 Elma: (360) 482-5269 IP14 Web: http://www.co.mason.wa.us ENFORCEMENT ACTIONS PENDING May 16, 2008 EARL LINCOLN P.O. BOX 368 BELFAIR WA 98584 Case Number: FIR2006-00003 Parcel Number: 123294390173 The Mason County Department of Community Development is currently reviewing all permits that are expired and have not been approved for occupancy and use. Pursuant to Mason County Code, Title 14 Building and Construction, a permit and final inspection for this type of activity is required under the 2006 International Fire Code or the code your permit was issued. Your property is currently in violation status of occupancy and use and is pending enforcement actions. You have been made aware of these requirements and to date, have not made the necessary arrangements. Current violations consist of the followina: 8-7-06 Permit was issued for a sprinkler system. 11-30-07 Notice was sent requesting final inspection. To date there has been no response and enforcement actions are pending. To brina vour site into compliance, you must: Schedule the necessary inspection(s). A $68 inspection fee will be due prior to each inspection. Please call (360) 427-9670 ext.262 to schedule inspections. Please contact our office to make the necessary arrangements 10 days from the date of this letter. Failure to contact our office to make the necessary arrangements will result in enforcement actions. In the event that you feel you have received this notice in error or that the facts are inaccurate, I strongly encourage you to contact me immediately to discuss your concerns. If not, I will expect these issues to be resolved within 10 days from the date of this letter. If you should have any questions, I can be reached by phone at (360) 427-9670 ext. 285. Sincerely, Larry Waters Mason County Building Department FIR2006-00003 1 of 1 '01/20/2005 15:28 FAX 360 427 7798 MASON CO PERMIT CTR [a 002 MASON COUNTY FIRE MARSHAL �t& M35M County Bldg_111426 W Cedar St PO BOX 186 Shelton,WA 985M (360)427-%70 Ext.273 Permit#_/~/T 2?00 -� Mason County Fire Protection System Permit Application Incomplete application will not be accented Owner: F,4R1 LS�J C c c_, Phone#; Mailing Address: City: State: WA Zip:---9 sag Site Address: SeZ 3 City: 8��r StateW� Zip: 9 Parcel#: Z� Z� 3��,l 3 Legal Description: '� - 51r�1 3f85 Lien/Title Holder: Address: City: State: Zip: Contractor. Fox er e4 �R.EJEnI Tl1 Phone#:,_ b 8�?-( i f q d S Address: City c u,9,90 State: UA Zip:� (a Contractor Registration#: fox rorj Expiration Date: Z 3 Building Square Footage(existing&proposed): 1"Z�o 2°4 2G9� 3'a Building Use: Occupancy Classification: Construction Type: Type of System: Type of Work: Sprinkler: Wet Dry X New System: StmdPlpe: Wet Dry 4'� Hood&Duct:Dry Chem: JAN 2 52006 F�P�'p: MASON COUNTY UL certified Monitoring company: Phone#: Contractors Bid Price: $ S 5 Sep 01 06 02: 48p Fox Fire Prevention, INC. 3608712262 p. 2 �91' SON COUNTY Department of Community Development FIRE PROTECTION SYSTEMS INSPECTION CARD* PO BOX 186, 426 W Cedar ST, Shelton WA 98584 General Questions: (360) 427-9670 ext 352 Inspection Requests: (360) 427-7262 Permit Number FIR2006-00003 Date 08/07/2006 Issued By Project Site Address 23552 NE STATE ROUTE 3 BELFAIR Applicant EARL LINCOLN Contractor FOX FIRE PREVENTION License Number FOXFIP1127M8 Con. Phone (360) 871-1985 Expiration Date 07/01/2008 Primary Code 20041FC Wet Chem N Sprinkler Y rY Use COMM D Chem N Standpipe N Hod and Duct N Public Works Access/Driveway Other Health De t Septic Well Plannin De t Site Inspection Fire Marshal Fire Apparatus Access Fire S rinkler p k Auto Fire Alarm Hpod and Duct Other it Fin ©/1 • o��o/- D!o GJh`�Building Dept Building Official: tt Dobey Concrete Setbacks Slab - ------------ Footing Perimeter Ret. Wall/Bulkhead Footing Interior Footing Decks/Porches Foundation Stem Other Rough-In Groundwork Plumbing Plumbing Groundwork Mechanical Other Groundwork Gas Pipe Gas Piping Fram ing Mechanical Insulation Slab Ceiling Floor Vaulted Ceilin Walls Vapor Barrier Other Wallboard Nailing Interior Wall $race Panels Fire walls Other Final Building Manuf. Home Setbacks Setup Concrete Foot/Runners Final Other PPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS HIS STRUCTURE MAY NOT BE USED FOR OCCUPANCY UNITL ALL APPLICABLE FINAL INSPECTIONS ARE COMPLETED O NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVALS ARE GIVEN. DST THIS CARD IN A CONSPICUOUS PLACE ON THE FRONT OF THE PREMISES CONVENIENT FOR MAIQNG REQUIRED VTRIES. LL PERMITS EXPIRE 180 DAYS AFTER PERMIT ISSUANCE OR 180 DAYS AFTER LAST INSPECTION ACTIVITY IS PERFORMED. dNNER/AGENT IS RESPONSIBLE FOR CALLING FOR ALL INSPECTIONS RIOR TO CALLI NG FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET- Sep 01 06 02: 48p Fox Fire Prevention, INC . 3608712262 p. 3 WASNINHI WRCTON STATE PATROL CONTRACTORS' MATERIALS & TEST REPORT FOR ABOVEGROUND PIPING ^ 2 1 PROCEDURE Upon completion of work, inspection and test shall be made by the contractor's representative and witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. PROPERTY NAME DATE Earl Lincoln Office Building May 11, 2006 PROPERTY ADDRESS 23552 NE State Route 3 Belfair, WA ACCEPTED 13Y APPROVING AUTHORITIES(NAME) MCFMO ADDRESS PLANS Shelton, WA INSTALLATION CONFORMS TO ACCEPTED PLANS ®YES ❑NO EQUIPMENT USED IS APPROVED ®YES ❑NO IF NO,EXPLAIN DEVIATION HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTOL VALVE AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? YES ®NO IF NO,EXPLAIN INSTRUCTIONS HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: 1. SYSTEM COMPONENTS INSTRUCTIONS ®YES ❑NO 2. CARE AND MAINTENANCE INSTRUCTIONS EYES LINO 3. NFPA 13 ® YES [INC) LOCATION SUPPLIES BUILDINGS Earl Lincoln Office Building OF SYSTEM MAKE MODEL YEAR OF QRIFICE SIZE QUANTITY TEMPERATURE RATING MANUFACTURE Tyco TYFRB Upright 2005 '/2 49 200 Tyco TYFRB Pendent 2005 '/2 62 155 Reliable F3QR Dry Pendent 2006 '/2 12 155 SPRINKLERS i TYPE OF PIPE PIPE AND Sch. 40, BLT FITTINGS TYPE OF FITTINGS BCI, MI, Grooved ALARM DEVICE MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION II TYPE MAKE MODEL MINUTES SECONDS i 1 ALARM VALVE OR 30 FLOW INDICATOR Flow Switch Potter WSFR-2 0 j 1 I i 30W-450-OD1 9t02