Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
COM2022-00075 Roof Solar - COM Inspections - 11/17/2022
INSPECTION CARD Mason County 615 W. Alder St. Bldg. 8, Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us PERMIT# COM2022-00075 PROJECT ADDRESS 35846 N US Highway 101 Lilliwaup, WA 98555 PARCEL# 324260004000 PROJECT DESCRIPTION Install 47.88kW roof-mounted, grid-tied Solar PV Array OWNER HAMA HAMA COMPANY ADDRESS AQUA CULTURE PHONE 360-877-5811 CONTRACTOR FORECAST ROOFING AND SOLAR LLC ADDRESS 12820 Avondale Way PHONE CONTRACTOR LICENSE FORECRS883DG LENDER INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments BLD-Final Inspection Framing Inspection Setback Inspection Rough-Plumbing Inspection Footing Inspection Mechanical Inspection Foundation Wall-Pre-Pour Insulation Inspection Shearwall Inspection Re-Roof-Final Inspection �aQ� S90WZ MASON COUNTY COMMUNITY SERVICES Permit No: YYIZOZZ -66o75 PERMIT ASSISTANCE CENTER: •BUILDING •PLANNING •FIRE MARSHAL A r 615 W.Alder St-Shelton, WA 98584 r \C C'ET,V www.co.mason.wa.us D Phone Shelton:(360)427-9670 ext. 352• Fax:(360)427-7798 Phone Belfair. (360)275-4467• Phone Elma:(360)482-5269 6 AUK 0??�?2 PLUMBING & MECHANICAL PERMIT APPLICATION 15 w Alder @t OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Hama Hama Company NAME:Forecast Solar LLC MAILING ADDRESS:35846 N us Hwy 101 MAILING ADDRESS:12820 Avondale way CITY:Lilliwaup STATE:wA ZIP:98555 CITY:Everett STATE:WA ZIP:98204 1"PHONE:360-463.6999 PHONE:425-487.6000 CELL: 2"d PHONE:206-240-2809 EMAIL :office@forecastsolar.com EMAIL:Kendra@hamahamaoysters.com lissa@hamahamaoysters.com L&I REG#FORECRL955MK EXP. 08 / 14 /2023 PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):324260004000 Zoning:83-Resource-Agricultural LEGAL DESCRIPTION(Abbreviated):cOVT LOT 34 a TAX 995,957 SITE ADDRESS:35846 N us Hwy 101 CITY:Lilliwaup DIRECTIONS TO SITE ADDRESS: Heading south on US Hwy 101, pass intersection of N Eldon Rd.After 0.2 mile,the destination will be on the left-hand side. TYPE OF JOB: NEW=ADD=ALT[�REPAIR=OTHER=USE OF BUILDING Agricultural/Aqua Culture LOCATION OF FIXTURES/UNITS—I ST FLOOR=2ND FLOOR=BASEMENT=GARAGED OTHER=✓ PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No. of Fixtures Fees Fuel Type:ElectricE ILPG=Natural Gas=Ductless= Toilets Type of Unit No. of Units Fees Bathroom Sink Furnace Bath Tubs Heat Pump Showers Spot Vent Fan Water Heater Propane Tank Clothes Washer Gas Outlets Kitchen Sinks Wood/Gas/Pellet Stove Dishwasher Kitchen Exhaust Hood Hose bibs Dryer Vent Other Solar Panel 1 Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor.I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Elizabeth James Digitally signed by Elizabeth James 08/0 1/2022 X Date:2022.08.01 16:08:09-07'00' Signature of Owner Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL Rev:1/27/2016 JBN Mason County c` Mason County - Division of Community Development 615 W. Alder St. Bldg.8 �`'��•Hnv ''= Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us FPROJECT 2-00075 ROOF MOUNT SOLAR PANEL- COMMERCIAL ESCRIPTION: INSTALL 47.88KW ROOF-MOUNTED, GRID- ISSUED: 10/13/2022 PV ARRAY ESS: 35846 N US HIGHWAY 101 LILLIWAUP EXPIRES: 04/11/2023 PARCEL: 324260004000 APPLICANT: HAMA HAMA COMPANY OWNER: HAMA HAMA COMPANY AQUA CULTURE AQUA CULTURE LILLIWAUP,WA98555 LILLIWAUP,WA98555 360-877-581 1 CONTRACTOR: Forecast Solar LLC 12820 Avondale Way Everett, WA 98204 4254876000 GENERAL CONTRACTOR'S LICENSE: FORECAST ROOFING AND SOLAR LLC License: FORECRS883DG 12820 Avondale Way Expires: 03/07/2024 EVERETT,WA98204 FEES: Paid Due Final Inspection $80.00 $0.00 Technology Surcharge $3.20 $0.00 Solar/PV Base Fee $30.00 $0.00 Solar/PV Fee $19.00 $0.00 State Fee-Commercial $25.00 $0.00 Plan Check Fee $80.00 $0.00 Totals : $237.20 $0.00 REQUIRED INSPECTIONS BLD-Final Inspection Framing Inspection Setback Inspection Rough- Plumbing Inspection Footing Inspection Mechanical Inspection Printed by:Anane Paysse on:10/13/2022 09:06 AM Page 1 of 4 Mason County Mason County - Division of Community Development 615 W.Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ROOF MOUNT SOLAR PANEL- COMMERCIAL COM2022-00075 Foundation Wall-Pre-Pour Inspection Insulation Inspection Shearwall Inspection Re-Roof-Final Inspection CONDITIONS * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982.The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. Printed by:Ariane Paysse on:10/13/2022 09:06 AM Page 2 of 4 Mason County � Mason County - Division of Community Development 615 W. Alder St. Bldg.8 Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ROOF MOUNT SOLAR PANEL- COMMERCIAL COM2022-00075 * The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International Mechanical Code, Uniform Plumbing Code,the International Fire Code, and be shall be listed and labeled in accordance with UL1703. Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the inspection by the Mason County Building Inspector. Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings. Not less than two-3-foot wide access pathways shall be provided from the eave to ridge. Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be available at time of inspection. Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors listed for the utility interaction Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number, collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are compatible with the collector. Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit. Solar energy collectors, controls, dampers,fans, blowers and pumps shall be accessible for inspection, maintenance, repair and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be constructed of noncombustible materials, flashed and sealed to prevent entry of water, rodents, and insects. The building inspector may require additional information, including an engineered design, to verify that existing roof or floor construction are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for inspection. * All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy code (WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth in the WSEC and international mechanical code. * The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency (ORCAA). It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos containing materials have been identified and removed from the area to be demolished. Work shall not commence on an asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B Limited Lane NW, Olympia WA98502, 360.586.1044/800.422.5623 www.orcaa.org Printed by:Ariane Paysse on:10/13/2022 09:06 AM Page 3 of 4 "^ _N Mason County ` Mason County - Division of Community Development 7� yrt; 615 W. Alder St. Bldg.8 ' i Shelton, WA 98584 360-427-9670 ext 352 www.co.mason.wa.us ROOF MOUNT SOLAR PANEL- COMMERCIAL COM2022-00075 OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. Applicant has indicated this is a replacement unit. Prior to Mason County allowing any occupancy of the new proposed unit, the existing unit which is on-site and is being replaced MUST be removed from the parcel. Qualifies for Over the Counter(OTC) Building Permit I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: �/ahg Contractor or Authorized Agent: /' 1,�/"�/ Date: Printed by:Ariane Paysse on:10/13/2022 09:06 AM Page 4 of 4 OVER-THE-COUNTER BUILDING PERMIT CHECKLIST FOR RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEMS: ROOFTOP MOUNTED c Contractors can apply for an Over-The-Counter(OTC)permit where the PV system meets the req it ie is in this Checklist.All project plans and supporting documentation must be provided on site for the inspector.1 S/Zep< ,pD --------TO BE COMPLETED BY APPLICANT------- 61 AUG 02 2022 © Project Information 5 w Alder Street Property Owner Name: Hama Hama Company Project Address: Parcel# 35846 N US Highway 101 324260004000 City: State. ZIP: Lilliwaup WA 98555 Day Phone: 360-877-5811 Contractor Name Forecast Solar LLC Contractor License#: FORECRL955MK Contractor day phone: 425-487-6000 Describe project: conventional framed built dwelling orgorage, Install solar PV system on a masonry building Pole structure,steel building,etc. at the Hama Hama Oyster Company Note: Manufactured/mobile homes require W Approval PV system description Install 47.88kW grid-tied, roof-mounted solar PV system. 1 - (include manufacturer SolarEdge SE40KUS inverter, 126 - Canadian Solar CS3N-390MS and model#of PV solar modules, 63 - SolarEdge SE-P860 optimizers, mounted on S-5-N modules and metal roof clamps and IronRidge solar racking system. inverters): ©Determine if your project qualifies for expedited permitting: Yes No 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three stories above grade or detached accessory structure that ❑ is code compliant to setbacks and height,or code allows expansion of nonconformity for solar modules. [IRC 101.2] 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by ❑ the local jurisdiction. 3. Rooftop is made from lightweight material such as a single layer of composition shingles, 121 ❑ metal roofing, lightweight masonry,or cedar shingles. 4. The installation shall comply with the manufacturer's instructions. [IRC M2302.2] 121 ❑ 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s) must be obtained from the Authority Having Jurisdiction to 121 ❑ administer the electrical code. [IRC M2302.2] 6. The installation shall meet the requirements of the International Fire Code as amended ❑ by WA State. [IRC M2302.21 7. The PV system is designed for the wind speed of the local area, and will be installed per ❑ the manufacturer's specifications. [IRC M2302.2.1(1)] 8. The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(2)] 0 ❑ 9. Total dead load of modules,supports, mountings, raceways and all other appurtenances ❑ weigh no more than four pounds per square foot. [IRC M2302.2.1(3)] 1 Enter total dead load of system(Ibs/ft'): Click here to enter text. 2.72 Ibs/sq.ft. 10. To address uplift,modules are mounted no higherthan 18"above the surface of the ❑ roofing to which they are affixed. [IRC M2302.2.1(4)] 11. Supports for solar modules are installed to spread the dead load across as many roof- framing members as needed to ensure that no point load exceeds fifty(50) pounds. p ❑ [IRC M2302.2.1(5)] 12. The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant treated wood equivalent to that required for IZI ❑ the roof construction. [IRC M2302.2.1] 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, ❑ rodents,and insects. [IRC M2302.2.2] 14. PV modules are listed and labeled with a fire classification in accordance with UL 1703. 0 ❑ [IRC M2302.2.3] Comments: Randy Collins(Fire Chief,rcollins@masoncountywa.gov)approves proposed fire setbacks via email on 7/13 If you answered yes to all of the above questions,the project qualifies for the over-the- counter permitting process. © Submit this Checklist, Site Plan, and other required permit application forms to: [insert contact info for jurisdiction having authority] E* As the property owner or authorized representative of the above listed property, I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature: W I I I H a be n i ch t Digitally signed by Will Habenicht Date: Date:2022.08.01 09:06:30-07'00' 08/01/2022 Applicant Name(Please Print): Will Habenlcht --------TO BE COMPLETED BY MASON COUNTY STAFF------ Qualifies for OTC Building Permit? ❑Yes ❑No Permit Application v- 06 o� Staff Initials Date: �"UI,�r^lnGhl�(�Z 2 mill SITE PLAN 1 " = 74' r--O'RECAS-r SOLAR (425)487-6000 Designer. Forecast Solar LLC Des a. _ ress: 12820 Avondale Way I - Everett,WA 98204 i• .,r Email: info@ForecastSolar.com Boundar Customer:Hama Hama Company r• Address:35846 N US Hwy 101 Lilliwaup,WA 98555 Phone:206-240-2809 45 Equipment Array Size 47.88kW Modules 126-Canadian Solar V' Module Wattage 38OW �,, ®>• Module Color All Black " PrOpOSed PV Arrays Module Dimension 39.2"x79.6"x35mm :" Inverter SolarEdge 4 1- Inverter Model SE40KUS Optimizer SE-P860 .Permit Document COM2022.00075 C:)` � � Racking System IronRidge J Racking Color BLACK Mounts 196 S 5 N 204"XR100 Rails 28 "e, 168'XR100 Rails 27 „ 124"XR100 Rails 0 Splice Kits 42 Grounds 19 End Clamp 52 c>e Mid Clamps 240 - Site/Job Details r Roof Type Standinq Seam ` F Roof Pitch 19 degrees Azimuth 75,165,255 System Weight 7,499 Ibs Total Array SO FT 2,757 s .ft. Total PSF 2.72 Ibsls .ft. Weight per mount 38.3 Ibslmount Mount Spacing 6'Maximum Wind Speed 110 mph ' Snow Load 30 lbs/s .ft. Installation : Will Habenicht Drawn by7 ROOF PLAN 1 " = 14' �►� FOR CAS r N SOLAR Note: Firefighter Access Pathways approved b g Y p P Y (425)487-6000 Randy Collins (Fire Marshal, RCollins@masoncountywa.gov) Designer. Forecast Solar LLC Address: 12820 Avondale Way and Nadine gown (District 17 Fire Chief, mason 17chief@gmail.com) Everett,WA98204 via email on 7/16/2022. 8"PathwayFiifighter Email: info@ForecastSolar.com Customer:Hama Hama Company Address:35846 N US Hwy 101 APPROVED AS NOTED Lilliwaup,WA98555 FOR PLAN REVIEW Phone:206-240-2809 APPROVED AS NOTED / Reviewed for Code Compliance for those items listed on / Equipment the application for permit. Array Size 47.88kW Project shall comply with permit conditions as noted on the permit. Modules 126-Canadian Solar The plans shall be on site at the time of the ins pion. Module Wattage 380W Failure to have pa mi an pans on s e may requre re-inspection. Module Color All Black Any plan revision shall be submitted and approved Module Dimension 39.2"x79.6"x35mm PRIOR to installat on or field changes.Changes in Engineering Docu nents or Details require a letter and Inverter SolarEdge stamped detail un ass otherwise approved. Inverter Model SE40KUS Mason County Optimizer SE-P860 Permit Document COM2 22-00075 Racking System IronRidge Racking Color BLACK Mounts 196-S-5-N 204"XR100 Rails 28 168"XR100 Rails 27 124"XR100 Rails 0 Splice Kits 42 Grounds 19 End Clamp 52 Mid Clamps 240 Site/Job Details Roof Type Standing Seam Roof Pitch 19 degrees Azimuth 75.165,255 System eight 7,499 Ibs O Total Arra SQ FT 2,757 s .ft. Total PSF 2.72 Ibs/s .ft. Weight per mount 38.3 Ibs/mount Mount Spacing 6'Maximum Wind Speed 110 mph 18" from Snow Load 30lbs/s .ft. ridge Installation Drawn by: Will Habenicht