Loading...
HomeMy WebLinkAboutBLD2024-00613 Deck - BLD Inspections - 8/26/2024 615 W.Alder St.Bldg 8,SHELTON,WA 98584 / MASON COUNTY SHELTON:360-427-9670, EXT 352 COMMUNITY SERVICES BELFAIR: 360-275-4467, EXT 352 �¢A Building,Plan nmq,Environmental Hcvlth,Community Health ELMA: 360-482-5269, EXT 352 -- www.co.mason.wa.us INSPECTION CARD AND CERTIFICATE OF OCCUPANCY" To schedule an inspection call or visit http://www.co.mason.wa.us/community-services/bid-inspection.php Permit Number BLD2024-00613 Date Issued 06/21/2024 Issued By / Project NEW 2ND STORY DECK Site Address 230 E Soundview Dr Applicant MACKELWICH WILLIAM&DELORES Contractor DA JOHNSON CUSTOM BUILDER Contractor Phone 1.360.490.0886 Primary Code UPC IBC, IRC,IFC, IEC,IMC,& Type Permit Type CARPORT/DECK/COVERED Occupancy -APPROVED PLANS MUST BE ONSITE FOR ALL INSPECTIONS. -DO NOT PROCEED BEYOND EACH STAGE OR COVER WORK UNTIL APPROVAL IS GRANTED. -THIS CARD MUST BE POSTED IN A CONSPICUOUS LOCATION, FRONT OF THE PREMISES IS BEST FOR MAKING ENTRY. -ALL PERMITS EXPIRE 180 DAYS AFTER THE PERMIT IS ISSUED OR 180 DAYS AFTER DATE OF LAST INSPECTION. -OWNER/AGENT IS RESPONSIBLE FOR REQUESTING ALL INSPECTIONS THROUGH FINAL INSPECTION. **THIS STRUCTURE MAY NOT BE USED OR OCCUPIED UNTIL ALL APPROVALS ARE GRANTED.** PRIOR TO CALLING FOR FINAL INSPECTION,ALL CONDITIONS OF THE PERMIT MUST BE MET Public Works Access/Driveway Other Health Septic Well Deptartment Planning Site Inspection Department Fire Marshall Fire Apparatus Access Fire Sprinkler Auto Fire Alarm Hood and Duct Other Final Building Department Building Official: Community Services Designee Concrete Setbacks __2 hL4 <R Slab Footing Perimeter Point load Footing Footing Interior Footing Decks/Porches 26 2K TrIL Foundation Stem Walls Other Rough-In Groundwork Plumbing Framing 2 2 Groundwork Mechanical Plumbing Groundwork Gas Pipe Mechanical Gas Piping Shear Wall Nailing Underfloor Other Insulation Slab Ceiling Floor Vaulted Ceiling Walls Vapor Barrier Other Wallboard Interior Wall Brace Panels Fire Walls Nailing Other Final Building I z(P Z-( -3:,_ Manufactured Setbacks Setup Home Concrete Foot/Runners Final Other 1=0 ot, Frantic t►� ( (=,tiwl t=ra I -�ZL ? /3) (2`{ 5 Ll— W } INSPECTION RESULTS Pagel Department of Community Development MASON COUNTY COMMUNITY SERVICES 615 W Alder St,Shelton,WA 98584 -•�_ -� - (360)427-9670 Application# BLD2024-00613 Application CARPORT/DECK/COVERED Application# BLD2024-00613 Ty Parcel# 320215901014 Site Address 230 E Soundview Dr Shelton,WA 98584 7-31-24-JQ er approved plans LTTP2(4 ct)are called out-Current condition DTT1Z is installed at(2)locs please add the approved deck ties x All joists shall be positively connected to the 2 beams with H2.5 hurricane ties ck Nab ✓!}otw•r Yes fob wble-rmTpteaa�issiri g doab4o-rim ,01!:Per IRC 2021 post notching is not an approved method of QI,,�,� J,-O JVLIV lk deck railing attachment all deck posts shall be tied into the 5 iw s�N ti✓mot key p-t deck framing with proper blocking and tieback hardware to `u`� Zw� with stand a lateral force of 500 Ibs �eti4 �O -Current condition all deck railing posts are notched @ 50% t4 and face screwed with 4"lag screws I4G /a}cv( A,, l vve tl+t PRESSiN please correct.Please see county hand out, Joshua Quarders BLD-FINAL INSPECTION FAIL section R507 and manufacture installation methods for wood deck guards. Deck footings are not at frost depth requirements per IRC 4403.footing inspection was not called in prior to pour. UE-� ����I✓rd Te�Co 24x24xl2(4) c 6.North side deck joist(2)are attached with decking screws this is not an approved method of attachment please install approved hanger or clip for the application. ..Per the approved plan the max height of the 4x6 deck post n �e rs -FVV / are 10'marked in red current condition 10'6" Joist spans are greater then 8'per table R507.9.1.3(1)on plans 1/2"lags shall be spaced no greater then 13"please correct. CALL FOR RE-INSPECTION WHEN CORRECTIONS ARE MADE BEFORE PROCEEDING WITH ANY FURTHER WORK ALL INSPECTIONS ARE TO BE CALLED IN BEFORE PROCCEDING WITH WORK GENERAL OBSERVATIONS AWAITING INSPECTION Description Status Status Date 4 t. Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 lip Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov B DD2024-00613 CARPORT/DECK/ COVERED PROJECT DESCRIPTION: NEW 2ND STORY DECK ISSUED: 06/21/2024 SITE ADDRESS: 230 E SOUNDVIEW DR SHELTON EXPIRES: 12/18/2024 PARCEL: 320215901014 APPLICANT: MACKELWICH WILLIAM&DELORES OWNER: MACKELWICH WILLIAM& DELORES 230 E SOUNDVIEW DR 230 E SOUNDVIEW DR SHELTON,WA 98584 SHELTON,WA 98584 1.360.545.4087 GENERAL CONTRACTOR'S LICENSE: DA JOHNSON CUSTOM BUILDER License: DAJOHCB101CB P O BOX 652 Expires: 01/19/2025 SHELTON,WA 98584 1.360.490.0886 VALUATIONS: FEES: Paid Due Uncovered Deck 170.00 $2,550.00 Building Permit Fee $156.00 $0.00 Technology Surcharge $4.72 $0.00 Planning Review Fee $240.00 $0.00 Plan Check Fee $80.00 $0.00 State Fee-Residential $6.50 $0.00 Total: $2,550.00 Totals : $487.22 $0.00 REQUIRED INSPECTIONS Setback Inspection Framing Inspection Footing Inspection BLD-Final Inspection CONDITIONS Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance contact the Mason County Public Works Department prior to construction at Ext 450 Printed by:Amber Selby on:06/21/2024 12:01 PM Page 1 of 3 Mason County PI� Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov CARPORT/DECK/ COVERED BLD2024-00613 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s) for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. " The foundation/footing must be placed on undisturbed, firm-native soil. Proper frost depth, minimum 12 inches, shall be observed below grade in undisturbed soils. REQUIREMENTS FOR ROOF COVERINGS. Roof coverings shall be applied in accordance with the applicable provisions of the current code and the manufacturer's installation instructions. A drip edge shall be provided at eaves and gables of shingle roofs. Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. All RED stamped approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour) will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. PLN SETBACKS Front (E): 25' Sides: 5' Rear: 20' .all setbacks measured from the farthest projection of the building `subject to EH setbacks *all changes are subject to review and approval COMPLIANCE WITH SECTION R507 OF THE 2021 IRC REQUIRED Printed by:Amber Selby on:06/21/2024 12:01 PM Page 2 of 3 J Mason County Mason County - Division of Community Development 615 W. Alder St. C Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov CARPORT/DECK/ COVERED BLD2024-00613 hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions ny ot6er stat local la regulating construction or the performance of construction. Issued B . ���� f Contractor or Authorized Agentcj, � vl Date ` �} Printed by:Amber Selby on:06/21/2024 12:01 PM Page 3 of 3