HomeMy WebLinkAboutBLD2024-00311 Roof Solar - BLD Inspections - 4/8/2024 INSPECTION CARD
Mason County
615 W. Alder St.
Building 8, Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
PERMIT# BLD2024-00311 PROJECT ADDRESS 131 E Woodland Dr Shelton, WA 98584
PARCEL# 420125100006 PROJECT DESCRIPTION ROOF MOUNTED SOLAR
OWNER LEANORD ET AL CAREY LEE ADDRESS DARLENE FAIRBANKS PHONE
CONTRACTOR Solgen Power LLC ADDRESS 5715 Bedford St PHONE 509-931-1663
CONTRACTOR LICENSE SOLGEPL820BE LENDER
INSPECTION INSP DATE Comments INSPECTION INSP DATE Comments
BLD-Final Inspection 4-g=112
Mason County
101 Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
BLD2024-00311 ROOF MOUNT SOLAR PANEL-
RESIDENTIAL
PROJECT DESCRIPTION: ROOF MOUNTED SOLAR ISSUED: 03/13/2024
SITE ADDRESS: 131 E WOODLAND DR SHELTON
EXPIRES: 09/09/2024
PARCEL: 420125100006
APPLICANT: LEANORD ET AL CAREY LEE OWNER: LEANORD ET AL CAREY LEE
DARLENE FAIRBANKS DARLENE FAIRBANKS
SHELTON,WA 98584 SHELTON,WA 98584
CONTRACTOR: SOLGEN POWER LLC
5100 ELM ROAD
PASCO,WA 99301
509-931-1663
GENERAL CONTRACTOR'S LICENSE: Solgen Power LLC License: SOLGEPL820BE
5715 Bedford St Expires: 01/05/2026
PASCO,WA 99301
509-931-1663
FEES: Paid Due
Technology Surcharge $1.60 $0.00
Solar/PV Fee $19.00 $0.00
Final Inspection $80.00 $0.00
Solar/PV Base Fee $30.00 $0.00
State Fee-Residential $6.50 $0.00
Totals : $137.10 $0.00
REQUIRED INSPECTIONS
BLD-Final Inspection
CONDITIONS
Printed by:Nikita Huckabey on:04/03/2024 11:49 AM
Page 1 of 3
Mason County
Mason County - Division of Community Development
615 W. Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-00311
* The installation of solar(thermal or photovoltaic)energy systems to provide space heating or cooling, hot water and
swimming pool heating shall conform to Chapter 23 of the International Residential Code, Chapter 14 of the International
Mechanical Code, Uniform Plumbing Code, the International Fire Code, and be shall be listed and labeled in accordance
with UL1703.
Roof mounted panels shall weigh no more than 4 Ibs per square foot. Supports for solar panels are to be installed to spread
the dead load across as many roof-framing members as needed to ensure that no point loads in excess of 50-Ibs are
created. Panels may be installed on roof assemblies with a single layer of roofing material. Roof assemblies with more than
one roofing material layer shall require an engineered analysis demonstrating that the roof will support the additional load of
the solar panel system. Attachment to the roof shall be in accordance with manufacturer specifications provided during the
inspection by the Mason County Building Inspector.
Roof mounted equipment shall comply with the International Fire Code Section 605.11, including signage and access
pathways. Roof access points shall not be located in areas where access ladders would block window or doors openings.
Not less than two-3-foot wide access pathways shall be provided from the eave to ridge.
Ground-mounted panels and modules, installation must be in accordance with the manufacturer's instructions and be
available at time of inspection.
Inverters shall be listed and labeled in accordance with UL 1741. Systems connected to the utility grid shall use invertors
listed for the utility interaction
Collectors and thermal storage units shall be listed and labeled to show manufacturer's name, model number, serial number,
collector weight, collector maximum allowable temperatures and pressures, and the type of heat transfer fluids that are
compatible with the collector.
Connections to potable water supplies shall be provided with backflow protection in accordance with the Uniform Plumbing
Code. Solar energy systems containing pressurized fluids shall be protected with a temperature and pressure relief valve
and be protected from freeze damage. Systems shall be equipped with means to limit the maximum water temperature of
the system fluid entering or exchanging heat with any pressurized vessel inside the dwelling to 180 degrees Fahrenheit.
Solar energy collectors, controls, dampers, fans, blowers and pumps shall be accessible for inspection, maintenance, repair
and replacement. The roof shall be constructed to support the loads imposed by roof-mounted solar collectors and shall be
constructed of noncombustible materials,flashed and sealed to prevent entry of water, rodents, and insects. The building
inspector may require additional information, including an engineered design, to verify that existing roof or floor construction
are adequate to support the additional load of the solar energy equipment. When required provide an engineered design for
inspection.
* The demolition and disposal of debris must meet the regulations of Mason County and Olympic Region Clean Air Agency
(ORCAA).
It is unlawful for any person to cause or allow the demolition (or major renovation)of any structure unless all asbestos
containing materials have been identified and removed from the area to be demolished. Work shall not commence on an
asbestos project or demolition project unless the owner or operator has obtained written approval from ORCCA.2490 B
Limited Lane NW, Olympia WA 98502, 360.586.1044/800.422.5623 www.orcaa.org
* Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries,
Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an
unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either
the homeowner, agent for the owner or a registered contractor according to WA state law.
Printed by:Nikita Huckabey on:04/03/2024 11:49 AM
Page 2 of 3
Mason County
Mason County - Division of Community Development
615 W.Alder St.
Building 8
Shelton, WA 98584
360-427-9670 ext 352
www.masoncountywa.gov
ROOF MOUNT SOLAR PANEL-RESIDENTIAL BLD2024-00311
OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit
revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or
contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained
permission from all the necessary parties, including any easement holder or parties of interest regarding this project.The
owner or authorized agent represents that the information provided is accurate and grants employees of Mason County
access to the above described property and structure(s)for review and inspection. This permit/application becomes null &
void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of
180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT
APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION UNLESS OTHERWISE APPROVED.
All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as
adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted
classification. Any non-approved change of use or occupancy would result in permit revocation.
I hereby certify that I have read and examined this application and know the same to be true and correct.
All provisions of Laws and Ordinances governing this type of work will be complied with whether
specified herein or not. The granting of a permit does not presume to give authority to violate or cancel
the provisions of any other state/local law regulating construction or the performance of construction.
Issued By:
Contractor or Authorized Agent: Date:
Printed by:Nikita Huckabey on:04/03/2024 11:49 AM
Page 3 of 3
DocuSign Envelope ID:52677841-1E2D-4D25-95A4-7E9C891F4CB4 ,/
MASON COUNTY COMMUNITY SERVICES Permit No: �(,�U�-`[ DD3 I I
PERMIT ASSISTANCE CENTER:
BUILDING•PLANNING•PUBLIC HEALTH.FIRE MARSHAL ►-t`E C E I` ,V�E D
40 615 W.Alder Street,Shelton,WA 98584 �f \\ f
Phone Shelton:(360)427-9670 ext 352•Fax:(360)427-7798 Phone .37 (� ).
Be/fair.(360)275�/467•Phone E/ma:(360)482-5269 MAR O 8 2024
BUILDING PERMIT APPLICATION 615
t
PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION:
NAME: Carey Leanord NAME: Solgen Power
MAILING ADDRESS: 131 E woodland Dr MAILING ADDRESS: 5715 Bedford St
CHTy: Shelton STATE: wA ZIP: 98584 CITY: Pasco STATE:wA ZIP: 99301
PHONE#1: (360) 584-4661 PHONE:(458) 225*7966 CELL--
PHONE#2: EMAIL: picseattle@purelightpower.com
EMAIL: carey.leanord@yahoo.com L&I REG# SOLGEPL820BE EXP.1/5/202J1
PRIMARY CONTACT: OWNER❑ CONTRACTOR® OTHER[]
NAME Julia No a EMAILpicseattle@purelightpower.com
MAILING ADDRESS 541 Parsons Dr CITW4edford STATE OR ZIP 97501
PHONE CELL
PARCEL INFORMATION:
PARCEL NUMBER(12 Digit Number) ZONING
LEGAL DESCRIPTION(Abbreviated) FIRE DISTRICT
SITE ADDRESS CITY
DIRECTIONS TO SITE ADDRESS
IS THE PROJECT WPI HIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO❑ SNOW LOAD:_Psf
IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (Check aft that apply):
SALTWATER❑ LAKE❑ RIVER/CREEK❑ POND❑ WETLAND❑ SEASONAL RUNOFF❑ STREAM❑
TYPE OF WORK: NEW❑ ADDITION❑ ALTERATION® REPAIR❑ OTHER ❑
USE OF STRUCTURE(Residence,Gamge,Commercial Bldg,Etc.) RESIDENCE
IS USE: PRIMARY® SEASONAL❑ NUMBER OF BEDROOMS NUMBER OF BATHROOMS
HEATED STRUCTURE? YES(wh.1,BW❑ YES(Part[s]ofBldg)❑ NO❑
DESCRIBE WORK PV SOLAR ROOF INSTALLATION VALUATION: 20,377.00
SQUARE FOOTAGE:(proposed)
1ST FLOOR sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. BASEMENT sq.ft.
DECK sq.ft. COVERED DECK sq.ft. STORAGE sq.ft. OTHER sq.ft.
GARAGE sq.ft. Attached❑ Detached❑ CARPORT sq.ft. Attached❑ Detached❑
MANUFACTURED HOME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED*
MAKE MODEL YEAR LENGTH
WIDTH BEDROOMS BATHS SERIAL NUMBER
ENVIRONMENTAL HEALTH:
SEWAGE/SEWER SOURCE: SEPTIC❑ SEWER❑ / NEW❑ EXISTING❑
PLUMBING IN STRUCTURE? YES❑ NO❑ Ifyes,attach completed Water Adequacy Form
PERIMETERNOUNDATION DRAINS PROPOSED? YES❑ NO❑ EXISTING SQ.FT.
EXISTING BEDROOMS PROPOSED BEDROOMS TOTAL BEDROOMS
OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by
signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed.I have
obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal
representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property
and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180
days or if construction work is suspended for a period of 180 days.
PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS
PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED.(MASON
Dows COUNTY CODE 14.08.42) 3/7/2024 1 9:12:37 PM PST
31&laoa4
Signature of OWNER(Must be signed by the OWNER) Date
DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS
BUILDING DEPARTMENT
PLANNING DEPARTMENT
FIRE MARSHAL
PUBLIC HEALTH
NOTES: PLAN
ACCESS POINT SHALL NOT BE PLAN VIEW TOTAL ROOF AREA: 2517.41 FT' LEGEND AHJSTAMP
1. LOCATED IN AREAS THAT REQUIRE THE TOTAL PV ARRAY AREA: 294.32 FT'
TOTAL%OF ROOF COVERED BY PV: 11.69
PLACEMENT OF GROUND LADDERS OVER FIRE SETBACKS
OPENINGS SUCH AS WINDOWS OR DOORS,
AND LOCATED AT STRONG POINTS OF
BUILDING CONSTRUCTION IN LOCATIONS
WHERE THE ACCESS POINT DOES NOT
CONFLICT MATH OVERHEAD ❑
VENT
OBSTRUCTIONS SUCH AS TREE LIMBS, =MECHANICAL
WIRES OR SIGNS. O =FLUE/PLUMBING VENT
2. STRUCTURES,PATIO COVERS,AND/OR
ADDITIONS BUILT WITHOUT PERMITS TO BE
RESOLVED BY A SEPARATE PERMIT.
, =STRING7
O STRUCTURAL STAMP
. =HOYMILES HM-1500NT(240V) '� Of`NASONFS
ROOF ACCESS MICROINVERTER(1 PER 4 MODULES) �tq6 7 HC'O
POINT _ Z
=HOYMILES HM-70ONT(240V)
MICROINVERTER(1 PER 2 MODULES) -0 201148 8
9
HOYM
■ ILES HM-35ONT Is
MIICROINVERTER(1 PER 01 MODULE) FSS 0NALENv�a
317/2024
O STRUCTURAL ONLY.
RETROFIT REQUIRED
R= o SEE ATTACHED LETTER
PITCH _22° PROJECT NAME
AZIMUTH -193° CAREY LEANORD 8 DARLENE
ROOF 1 MODULE QTY -6 FAIRBANKS
_ RAFTER -2"X6"@ 24"O.C.
SURFACE TYPE -COMPOSITE SHINGLE 131 E WOODLAND DR,SHELTON,
84
(14)YUKON SERIES SEG-410-BMD-HV MODULES WITH (� PITCH -1.(02)HOYMILES HM-150ONT(240V)MICRO-INVERTER AZIMUTH -104' 3605844661
UNDER EVERY FOUR MODULES&(02)HOYMILES Q ROOF 2 MODULE QTY -8 camy.leenord@yahoo.com
HM-70ONT(240V)MICRO-INVERTER UNDER EVERY TWO N RAFTER -COMPOSITE
O 24"O.C. APNM SON COUNT
Z SURFACE TYPE -COMPOSITE SHINGLE AHJ:MASON COUNTY
MODULES&(02)HOYMILES HM-350NT(240V) O O Q. UTIUN:MASON COUNTY PUD 1 ZONE 2
MICRO-INVERTER UNDER EVERY ONE MODULE � REVISIONS
Z REV DESCRIPTION DATE
O
44.65" SHEET TITLE
(E)PATIO ACD UM
T SITE PLAN
MSP I}
DRAWN DATE 1 3/5/2024
(N)VISIBLE-OPEN,LOCKABLE,LABELED (N)JUNCTION BOX 67.80" IDRAWN BY I VGN
AND NON FUSED AC DISCONNECT NEMA 3R
(SQUARE D DU221 RB) SHEET NUMBER
N
SITE PLAN (E)UTILITY METER A PV-02 SCALE:1/8"=T-0" (E)MAIN SERVICE PANEL (OVERHEAD
135 845 397 p\/
SERVICE) r V-02
1 T
CONTRACTOR AHJ STAMP
HT PRACTOPOWAIERNEWCOLLC NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM
5.740 KW DC/4.966 KW AC
3521 AVION DRIVE,SUITE 9200,
p
Purelight -)wer MEDFORD,OREGON 97504 131 E WOODLAND D R, S H E LTO N, WA 98 584
PHONE-(541)816-4047
LIC.NO.-226333
DESIGN CRITERIA NEW PV SYSTEM SPECIFICATIONS APPLICABLE CODES SHEET INDEX
SYSTEMS ZE: DC SIZE:5.740 KW DC{STC)
1.ROOF PRCH: 22 ALL WORK SHALL CONFORM TO THE FOLLOWING CODES:
2.AZIMUTH: 193,104 AC SIZE:4.986 KW AC 2021 WASHINGTON STATE BUILDING CODE PV-01 GENERAL NOTES/DESIGN CRITERIA
3,MODULE: (14)YUKON SERIES SEG410-BMD-HV PROJECT NOTES 2021 WASHINGTON STATE RESIDENTIAL CODE PV-01 PROPERTY PLAN
4.INVERTER: (02)HOYMILES HM•1500NT(240V) 1.1.1 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE 2021 WASHINGTON STATE EXISTING BUILDING CODE PV-02 SITE PLAN
(02)HOYMILES HM-70ONT(240V) RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE(NEC),ALL 2021 WASHINGTON STATE FIRE CODE PV-03 ATTACHMENT PLAN 8 DETAILS
(02)HOYMILES HM-35ONT(240V) MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS,AND THE 2020 NATIONAL ELECTRICAL CODE OF WASHINGTON STATE PV-03.1 FRAMING DETAIL STRUCTURAL STAMP
5.NOMINAL AMPERAGE: 20AB RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING AS ADOPTED BY MASON COUNTY PV-04 ELECTRICAL DIAGRAM
6.ROOF AREA: 2517.41 FT- JURISDICTION'S(AHJ)APPLICABLE CODES.
7.PV ARRAY AREA: 294.32 FT' 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED PV-04.1 ELECTRICAL CALCULATIONS ��VOR JO
6.PV ARRAY WEIGHT: 663.60 LBS AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO OPERATION PV-05 WARNING LABELS N
9.ROOF SURFACE TYPE: COMPOSITE SHINGLE 1.1.3 ALL PV SYSTEM COMPONENTS;MODULES,UTILITY4NTERACTIVE PV-05.1 DIRECTORY PLACARD Of'NASh/N S
10.ROOF STRUCTURE: 2-XB'RAFTER 0 24-OC INVERTERS,AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND SCOPE OF WORK ♦� rt
12.1 CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EQUIPMENT DATASHEETS ATTACHED tir o
11.BUILDING STORY: ONE STORY LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM. ti Z
12.SNOW LOAD: 25 PSF OTHER GOVERNING CODES THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF
13.NAND SPEED: 97 MPH 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING EXISTING ONSITE CONDITIONS TO DESIGN,SPECIFY,AND VICINITY MAP
14.NAND EXPOSURE: B CODE.IF EXPOSED TO SUNLIGHT,IT SHALL BE UV RESISTANT.ALL INSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEM 201148 8 ?
15.RISK CATEGORY: II PLAQUES AND SIGNAGE WALL BE INSTALLED AS REQUIRED BY THE NEC DETAILED IN THIS DOCUMENT
AND AHJ. NM.
GENERAL NERAL NOTES
SITE NOTES STRUCTURAL NOTES(CONY.) DISCONNECTION AND OVERCURRENT PROTECTION NOTES 3/7Y.
2.1.1 A LADDER WILL BE IN PLACE FOR INSPECTION IN 2.3.3 ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED 2.6.1 DISCONNECTING SWITCHES SHALL BE V 1RED SUCH THAT STRUCTURAL ONLY.
ACCORDANCE WITH OSHA REGULATIONS. AND SEALED W/APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING f RETROFIT REQUIRED,
A
A THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE CONTRACTOR. ENERG
WITH IZED ARE CONNECTED TO THE TERMINALS MARKED'UNE Q SEE ATTACHED LETTER
AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM TH NO 2.3.4 ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER SIDE'(TYPICALLY THE UPPER TERMINALS), mtwwrrtr,
STORAGE BATTERIES. THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER 2.62 DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY Q
2A.3 THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY OR PROFESSIONAL ENGINEERING GUIDANCE. PERSONNEL,BE LOCKABLE,AND BE A VISIBLE-BREAK SWATCH PROJECT NAME
PLUMBING,MECHANICAL,OR BUILDING ROOF VENTS. 2.3.5 WHEN POSSIBLE,ALL PV RELATED RACKING ATTACHMENTS WALL BE 2.6.3 PV SYSTEM CIRCUITS INSTALLED ON OR IN HABITABLE CAREY LEANORD$DARLENE
2.1.4 PROPER ACCESS AND WORKING CLEARANCE AROUND STAGGERED AMONGST THE ROOF FRAMING MEMBERS. BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO
EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN FAIRBANKS
PROVIDED IN ACCORDANCE WITH SECTION NEC 110.26. WIRING 6 CONDUIT NOTES ACCORDANCE WITH 690.12 131 E WOODLAND DR,SHELTON,
2.1.5 ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND 2.4.1 ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR 2.6.4 ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC WA 98584
MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE PURPOSE.CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM 690.8.690.9,AND 240. SATELLITE MAP 3605844861
APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.6.5 INVERTER ON-GRID BRANCHES SHALL BE CONNECTED TO A
ROOF COVERING SERVES TO PROTECT THE BUILDING OR 2.4.2 CONDUCTORS SIZED IN ACCORDANCE WITH THE NEC SINGLE BREAKER OR GROUPED FUSE DISCONNECT(S)IN care PN#.42012 100006
STRUCTURE. 2.4.3 AC CONDUCTORS TO BE COLORED OR MARKED PER NEC ACCORDANCE WITH NEC 110.3(B). AJ!M SON COUNT
2.4.4 LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN 2.6.6 IF REQUIRED BY THE AHJ,SYSTEM WILL INCLUDE ARC-FAULT AHJ:MASON COUNTY
UTILITY:MASON COUNTY PUD 1 ZONE 2
EQUIPMENT LOCATIONS ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR CIRCUIT PROTECTION IN ACCORDANCE WITH NEC 690.11 AND
22.1 ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS IN LABELING PER NEC UL16998.
REVISIONS
ACCORDANCE WITH NEC 110.26.
2.2.2 HARING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE GROUNDING NOTES INTERCONNECTION NOTES REV DESCRIPTION DATE
RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED 2.5.1 GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR 2.7.1 LOAD SIDE INTERCONNECTION SHALL BE IN ACCORDANCE
BY NEC 690.31(A),(C)AND NEC TABLES 310.15(B)(2)(A)AND 310.15 PURPOSE,AND GROUNDING DEVICES EXPOSED TO THE ELEMENTS SHALL WITH NEC 705.12.
(B)(3)(C). BE RATED FOR SUCH USE. 2.72 THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS
22.3 JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER 2.5.2 PV EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NEC OUTPUT MAY NOT EXCEED 120 PERCENT OF BUSBAR RATING PER
PV MODULES IN ACCORDANCE WITH NEC 690.34. 690.43 AND NEC TABLE 250.122. NEC 705.12.
22.4 ADDITIONAL AC DISCONNECT(S)SHALL BE PROVIDED 2.5.3 METAL PARTS OF MODULE FRAMES,MODULE RACKING,AND 2.7.3 THE SUM OF 125 PERCENT OF THE POWER SOURCE(S)OUTPUT
WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC ENCLOSURES CONSIDERED GROUNDED IN ACCORDANCE MATH NEC CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE
SERVICING DISCONNECT.22.6 ALL EQUIPMENT SHALL BE 250.134 AND 250.136(A). PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF
INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL IN 2.5.4 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED IN THE AMPACITY OF THE BUSBAR,PV DEDICATED BACKFEED
ACCORDANCE WITH NEC APPLICABLE CODES. ACCORDANCE WITH NEC 690.45 AND INVERTER MANUFACTURER'S BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM SHEET TITLE
22.6 ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND INSTALLATION PRACTICES THE UTILITY SOURCE OCPD IN ACCORDANCE WITH NEC 705.12. GENERAL NOTES
RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 2.5.5 EACH MODULE WALL BE GROUNDED AS SHOWN IN MANUFACTURER 2.7.4 AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER
DOCUMENTATION AND APPROVED BY THE AHJ.2.5.6 THE GROUNDING PANEL,TOTAL RATING OF ALL OVERCURRENT PROTECTION DEVICES DESIGN CRITERIA
STRUCTURAL NOTES CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE SHALL NOT EXCEED AMPACITY OF BUSBAR.HOWEVER,THE MAIN
2.3.1 RACKING SYSTEM 3 PV ARRAY WILL BE INSTALLED IN REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING OVERCURRENT PROTECTION DEVICE MAY BE EXCLUDED IN
ACCORDANCE WITH THE CODE-COMPLIANT INSTALLATION CONDUCTOR TO ANOTHER MODULE. ACCORDANCE WITH NEC 705.12. DRAWN DATE 1 3/5/2024
MANUAL.TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN 2.5.7 GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE 2.7.5 FEEDER TAP INTERCONNECTION(LOAD SIDE)IN ACCORDANCE DRAWN BY VGN
MODULES,AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE COLORED GREEN OR MARKED GREEN IF 04 AWG OR LARGER PER NEC WITH NEC 705.12.
BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY,IN 250.119 2.7.6 SUPPLY SIDE TAP INTERCONNECTION IN ACCORDANCE WITH
ACCORDANCE WITH RAIL MANUFACTURER'S INSTALLATION 2.5.8 THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 TO NEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS IN SHEET NUMBER
PRACTICES. AND NEC 250.50 THROUGH 250AD6.IF EXISTING SYSTEM IS INACCESSIBLE, ACCORDANCE WITH NEC 230.42.
2.3.2 JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S OR INADEQUATE,A GROUNDING ELECTRODE SYSTEM PROVIDED IN 2.7.7 BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES n\Y_o 0
SPECIFICATIONS.IF ROOF-PENETRATING TYPE,IT SHALL BE ACCORDANCE WITH NEC 250,NEC 690.47 AND THE AHJ. OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING PER NEC 705.12. r V
FLASHED 8 SEALED PER LOCAL REQUIREMENTS. 2.5.9 GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 69OAl(B)(1)
AND TO REDUCE FIRE HAZARDS
LEGEND AHJ STAMP
-PROPERTY LINE
—�--�— -FENCE LINE
ROOF ACCESS POINT
j 124'-1"
(E)GARAGE
` STRUCTURAL STAMP
17'-811 �t�voR ioV,
WASFf S p
j i z
❑
Q201148 8 ?
DRI VEWgy j ASS ONAI EN13/
12024
o Q
10 '-1" I I nY.
' STRUCTURAL ONLY.
RETROFIT REQUIRED,
32'-811 0 a j J SEE ATTACHED LETTER
8r-�rr Q PROJECT NAME
2
CAREY LEANORD 8 DARLENE o
C(,J FAIRBANKS
131 E WOODLAND DR,SHELTON.
J j WA 88584
O 3605844661
O = jI I' carey.leenord@yehw.wm
r W APN#420125100008
0 O I AHJ:MASON COUNTY
UTILITY:MASON COUNTY PUD 1 ZONE 2
(E)HOUSE i j REVISIONS
LEV DESCRIPTION DATE
1100'-111
_ I
SHEET TITLE
(E)PATIO — — COVER PAGE
_ DRAWM DATE 3/5/2024
DRAWN BY I VGN
" 1 PROPERTY PLAN (E)FENCE SHEET NUMBER
APV-01 SCALE:1/16"=1'-0" PV-01
c t
c I
NOTES:ROOF ACCESS POINT SHALL NOT BE FLANVIEW TOTAL ROOF AREA: 2517.41 FT' LEGENDAHJ STAMP
1. L PV ARRAY AREA: 294.32 FT'LOCATED IN AREAS THAT REQUIRE THEPLACEMENT OF GROUND LADDERS OVERL%OF ROOF COVERED BY PV: 11.69%
OPENINGS SUCH AS N OR DOORS, FIRE SETBACKS
S
AND LOCATED AT STRONG
POINTS OF 1
BUILDING CONSTRUCTION IN LOCATIONS
WHERE THE ACCESS POINT DOES NOT
CONFLICT WITH OVERHEAD
OBSTRUCTIONS SUCH AS TREE LIMBS, =MECHANICAL VENT
WIRES OR SIGNS. O =FLUE I PLUMBING VENT
2. STRUCTURES,PATIO COVERS,AND/OR
ADDITIONS BUILT WITHOUT PERMITS TO BE
RESOLVED BY A SEPARATE PERMIT.
=STRING 1
O STRUCTURALSTAMP
. =HOYMILES HM-1500NT(240V) SP�Q WASH 61
ROOF ACCESS MICROINVERTER(1 PER 4 MODULES) yt� Cj02
POINT
=HOYMILES HM-70ONT(240V)
MICROINVERTER(1 PER 2 MODULES) 0 201148 8 ?
1F, .�
■ HOYMILES M CROINVERTTERS(PER1 MODULE) FSS ONALE�G\�
3n/2024
O STRUCTURAL ONLY.
RETROFIT REQUIRED,
R=1 o SEE ATTACHED LETTER
PITCH -22° PROJECT NAME
AZIMUTH -193° CAREY LEANDRO&DARLENE
ROOF1 MODULEQTY -6 FAIRBANKS
_ RAFTER -2"XB' 24'O.C.
SURFACE TYPE -COMPOSITE SHINGLE 131 E WOODLAND DR,SHELTON,
(14)YUKON SERIES SEG-410-BMD-W MODULES WITH Ln L(. iRFACETYPE
CH 22° WA 98584
(02)HOYMILES HM-1500Ni(240V)MICROaNVERTER MUTH -1oa° 3605844661
UNDER EVERY FOUR MODULES&(02)HOYMILES O ROOF 2 DULE OTY 8 cere PN M.4201 5100006
HM-70ONT(24OV)MICR04NVERTER UNDER EVERY TWO N FTER 2"X6"()?24"O.C. APNM SON COUNTY
(� = -COMPOSITE SHINGLE AHJ:MASON COUNTY
MODULES&(02)HOYMILES HM-35ONT(24OV) O O Li- UTILITY:MASON COUNTY PUD 1 ZONE 2
MICRO-INVERTER UNDER EVERY ONE MODULE O
REVISIONS
O
REV DESCRIPTION DATE
m 44.65 SHEET TITLE
(E)PATIO ACO UM
T SITE PLAN
MSP tl
DRAWN DATE 1 3/5/2024
(N)VISIBLE-OPEN,LOCKABLE,LABELED (N)JUNCTION BOX 67.8011 DRAWN BY I VGN
AND NON FUSED AC DISCONNECT NEMA 3R
N SITE PLAN (SQUARE D Du221RB) SHEET NUMBER
A (E)UTILITY METER 1 1
PV-02 SCALE: (E)MAINSERVICEPANEL (OVERHEAD SERVICE)
397) PV-02
DISTRIBUTED LOAD CALCULATIONS LEGEND A HJ STAMP
MODULE YUKON SERIES SEC 410-BMD-HV
MODULE WEIGHT 47.4 LSS -ATTACHMENT POINTS
MODULE DIMENSIONS(L-K W) 67.801K 44.BS
TOTAL OTY.OF MODULES 14 -RAIL
TOTAL WEIGHT OF MODULES 663.60 LBS
STRUCTURAL MEMBER
TYPE OF RACKING CHIKO CK-FT-R537B2 RAIL -
TYPE OF ATTACHMENT IRONRIDGE L-MOUNT
DISTRIBUTED WEIGHT OF RACKING D.5 PSF
TOTAL WEIGHT OF ARRAY 810.76 LBS
AREA OF MODULE 21.02 SOFT.
TOTAL ARRAY AREA 1294.32 SOFT.
DISTRIBUTED LOAD IZ75 PSF
4'-0"OC ATTACHMENT SPACING 4'-0"OC ATTACHMENT SPACING
STRUCTURAL STAMP
t���f WRASONFS
J�� Hcr 0
h 2
201148 8 C
GIs
FSS ONALEaG\�
3n/2024
STRUCTURAL ONLY.
RETROFIT REQUIRED,
SEE ATTACHED LETTER
STRUCTURAL MEMBER 0 24"OC STRUCTURAL MEMBER @ 24"OC PROJECT NAME
CAREY LEANORD 8 DARLENE
1.0 TYPICAL ATTACHMENT PLAN (PORTRAIT) 1,1 TYPICAL ATTACHMENT PLAN (LANDSCAPE) FAIRBANKS
PV-03 PV-03 131 E 98584
DR,SHELTON,
SCAI e:NTS SCALE:NTS
3605844661
mmy.Ieafl dQyahw.wm
APN 0..420125100006
AHJ:MASON COUNTY
rJ 18e UTILITY:MASON COUNTY PUD 1 ZONE 2
PvMODULE 4" PVMODULE REVISIONS
CH KO CK-FT-N537B2 REV DESCRIPTION DATE
GROUNDING RAIL
ENOMIO CLAMP
C SINGLE LAYER OF
SEE ENLARGED VIOMP SHINGLE
EW C
ArIACH OE L-FOOT
ATTACHMENTS
SHEET TITLE
FLASHING
MIN.SHe-IAG BOLTWTH MIN, ATTACHMENT PLAN
(E)STRUCTURAL MEMBER STRUCTURAL
TURAL EMBERNT O &DETAILS
STRUCTURAL MEMBER
DRAWN DATE 3/5/2024
(E)STNIICTIIRAL MEMBER DRAWN BY VGN
SHEET NUMBER
ATTACHMENT DETAIL ENLARGED VIEW PV-03
Pv-o3 PV-03 Sale:NTS
c 6
PITCH _22• AHJSTAMP
AZIMUTH -193'
ROOF 1 MODULE OTY -6
_ RAFTER -2'X6'024.O.C.
SURFACE TYPE -COMPOSITE SHINGLE
PITCH 1.
AZIMUTH -104'
ROOF 2 MODULE.1 -6
_ RAFTER -2'X6'0 24.O.C.
SURFACE TYPE -COMPOSITE BHINGLE
STRUCTURAL STAMP
W�SOryCo
y 2
PV MODULES 1'-7rr
PV MODULES � 201148 s 2
_ -10 fGiS �a
/ONALENG
5'-8' 3,,/2024
STRUCTURAL ONLY.
$'-3' RETROFIT REQUIRED,
5.1 3-5 SEE ATTACHED LETTER
5.1
22' 22' PROJECT NAME
CAREY LEANORD&DARLENE
FAIRBANKS
16'-0" 15'_g" 14'-7" 131 E WOODLAND DR,SHELTON,
2'-3' '-9" WA 96564
2'-3" 12'-1" 13'-10" 3eo ,
carey.leenordtbyad@ye hoo.com
APN M 420125100006
COUNTY
2"X6"CEILING JOIST 2"X6"CEILING JOIST AAS NCOMASON COUNTY
UTIUTV:MASON COUNT'PUD 1 ZONE 2
t@ 24"O.C. @ 24"O.C.
2"X6"RAFTER @ 24"O.C. 2"X6"RAFTER @ 24"O.C. REVISIONS
REV DESCRIPTION DATE
SHEET TITLE
FRAMING DETAIL
ROOF 2 ROOF 1
DRAWN DATE 3/5/2024
DRAWN BY I VGN
SHEET NUMBER
FRAMING DETAIL PV-03.1
PV-03.1 SCALE:NTS
AHJ STAMP
NOTE:
THE RETROFIT SHALL CONSIST OF 2X6 SISTER FOR (I)PV ATTACHMENT
THE EXISTING SPLITTING 2X6 RAFTER AS SHOWN IN PER PLAN
THE PHOTOS BELOW,WITH 1/4"DIA.X 3"SDS SCREWS
AT 12"O.C.,STAGGERED.NEW SISTER TO EXTEND (E)PLYWOOD
WITHIN 12"OF EXISTING 2X,ONLY REQUIRED AT =
EXISTING MEMBER WITH NEW SOLAR ATTACHMENT.
RETROFIT SHOULD HAPPEN BEFORE INSTALL. `' -- --
(E)2x PER PLAN --T (N)2x6 SISTER W1 I/4"O x 3"SDS'SCREWS @ 12"
l" O.C.,STAGGERED(NO ADD.HGR.REQ'D.)
Pictures of poor condition-area to be retrofit(where applies) ? - (N)2x TO EXTEND WITHIN 12"OF(E)2x ONLY
REQ D @(E)RAFTER W/(N)SOLAR ATTACHMENT
! STRUCTURALSTAMP
Ri
SECTION"A-A" t?r`oF wW
h i
(I)PV ATTACHMENT 9 z01148 s Q.-
PER PLAN Ecrs
(E)RIDGE FSS'oNALEN�'
Ire/ 3/7/2024
STRUCTURAL ONLY.
SIMPSON'MP36' RETROFIT REQUIRED,
-'�� SEE ATTACHED LETTER
6"
A e PROJECT NAME
CAREY LEANDRO&DARLENE
FAIRBANKS
" 131 E WOODLAND DR,SHELTON,
(E)SHEATHING (N) N6 SISTERED WA 08584
RAFTER 3605844661
mmy.leenord@ye0oo.com
APN A.4201
..420125100008
AHJ:MASON COUNTY
UTILITY:MASON COUNTY PUD 1 ZONE 2
A REVISIONS
Y2L MIN. REV DESCRIPTION DATE
I
(E)WALL
SHEET TITLE
RETROFIT DETAIL
DRAWN DATE 1 3/5/2024
DRAWN BY I VGN
2 ISTERED RAFTERS DETAILS SHEET NUMBER
SCALE: NTS PV-03.2
120%RULE FOR BACKFEED BREAKER NEC 705.12.(B) AHJ STAMP
FORMULA RESULT
MINIMUM WIRE SIZES CALLED OUT. AC DISCONNECT TO BE LOCATED
USE OF LARGER WIRE IS WITHIN 1OFT OF THE UTILITY METER
ACCEPTABLE. TOTAL INVERTER OUTPUT CURRENT x 1.25=((02 x 5.99)+(02 x 25.85A(SELECTED PV BREAKER=30A)
2.90)+(02 x 1.45))A x 1.25
BUS BAR RATING x 1.2-MCB RATING=MAX ALLOWABLE PV BREAKER SELECTED PV BREAKER 5 MAX ALLOWABLE PV BREAKER
225A x 1.2-200A=70A 30A 5 70A
STRUCTURAL STAMP
METER#:135 645 39
TO UTILITY GRID
L1 L2 N
(E)BI-DIRECTIONAL
(N)AC DISCONNECT 30A UTILITY METER
VISIBLE,LOCKABLE, 1-PHASE,3-W,
LABELED AND NON-FUSIBLE, M 120V240V
240V,NEMA 3R,UL LISTED (OVERHEAD SERVICE)
(SQUARE D DU221RB)
YUKON SERIES SEG-410-BMD-HV Ll 11E
14 MODULES AND 6 MICROINVERTERS IN BRANCH CIRCUIT 1 BREA200A/2KER,
MAIN
BR
MANUFACTURER BREAAKER,240V
(Qj)"
) PROVIDED TRUNK (TOP FED)
CABLE
... L
(E)225A MAIN PROJECT NAME
(I)JUNCTION BOX (2)# (2)#10 AWG SERVICE PANEL,240V
60D V,NEMA 3R (1)#10 EGC (1)#10 EGC CAREY LEANORD&DARLENE
-,r, �, i ULLISTED FAIRBANKS
(-_ I------------- I- 1 PV 30A2P LOAD SIDE
131 E WOODLAND DR,SHELTON,
INTERCONNECTION WA 985M
AT MAIN PANEL 3605844661
(2)HOYMILES HM-1500Ni(240V)
MICROINVERTERS ONE UNDER N carey.leenord�yehoo.com
EVERY FOUR MODULES (2)HOYMILES HM7DONT(240V) - ---- APN#420125100006
MICROINVERTER ONE UNDER y/.�{_ AHJ:MASON COUNTY
EVERY TWO MODULES Y UTILITY:MASON COUNTY PUD 1 ZONE 2
GEC
(2)HOYMILES HM35ONT(240V) #6 AWG
EXISTING GROUNDING REVISIONS
BARE CU
MICRO INVERTER ELECTRODE SYSTEM
EVERY ONE MODULES - RE DESCRIPTION DATE
SOLAR BREAKER LOCATED AT THE
FURTHEST END OF BUSBAR FROM THE
MAIN BREAKER OR FEEDER UNIT
SHEET TITLE
ELECTRICAL
DIAGRAM
DRAWN DATE 1 3/5/2024
DRAWN BY I VGN
SHEET NUMBER
PV-04
MICROINVERTER SPECIFICATIONS SOLAR MODULE SPECIFICATIONS AMBIENT TEMPERATURE SPECIFICATIONS
MANUFACTURER/MODEL# IHOYMILES HM-150ONT(240V) MANUFACTURER/MODEL# YUKON SERIES SEG-410-BMD-HV RECORD LOW TEMP -7•C AHJ STAMP
INPUT POWER RANGE 300W-505W VMP 31.05V AMBIENT TEMP(HIGH TEMP 2%AVG.) 30-C
MIN/MAX START VOLTAGE 2 IMP 13.21A
NOMINAL MINIMUM CONDUIT HEIGHT ABOVE ROOF SURFACE 7/8"
MAX CONT.. VOLTAGE OUTPUT CURRENT 5.9940V.99A TO 37.32V ISC 13.80A SOURCMNERG"ES�TNER M.E
HTf FS/iENE ROYRESEMCH.UCF.EO W SOURCERIFIGTIO W SOU1Rfff FERENCE#NP/
MAX CONT.OUTPUT POWER 1438W TEMP.COEFF.VOC -0.27%/"C
MAX MODULES PER STRING 16(04 MICROINVERTERS)
MICROINVERTER SPECIFICATIONS
MANUFACTURER/MODEL# IHOYMILES HM-70ONT(240V)
INPUT POWER RANGE 280W-470W
MIN/MAX START VOLTAGE 122VI60V
NOMINAL AC VOLTAGE 1240V
MAX CONT.OUTPUT CURRENT 12.90A
MAX CONT.OUTPUT POWER 1696W
MAX MODULES PER STRING 116(08 MICROINVERTERS)
MICROINVERTER SPECIFICATIONS
MANUFACTURER/MODEL# HOYMILES HM-35ONT(240V) STRUCTURALSTAMP
INPUT POWER RANGE 280W-470W
MIN/MAX START VOLTAGE 22V/60V
NOMINAL AC VOLTAGE 240V
MAX CONT.OUTPUT CURRENT 1.45A
MAX CONT.OUTPUT POWER 349W
MAX MODULES PER STRING 16(16 MICROINVERTERS)
PROJECT NAME
CAREY LEANORD&DARLENE
FAIRBANKS
131 E WOODLAND DR,SHELTON,
WA 98584
3605844661
carey.leanord@yahoo.wm
APN M.420125100006
AHJ:MASON COUNTY
UTILITY:MASON COUNTY PUD 1 ZONE 2
REVISIONS
REV DESCRIPTION DATE
SHEET TITLE
ELECTRICAL
CALCULATIONS
DESCRIPTION FORMULA RESULT
PV OVERCURRENT PROTECTION NEC 690.9(B) TOTAL INVERTER OUTPUT CURRENT x 1.25=((02 x 5.99)+(02 x 2.90)+(02 x 1.45))A x 25.85A(SELECTED PV BREAKER=30A) DRAWN DATE 3/5l2024
1.25 DRAWN BY VGN
120%RULE FOR BACKFEED BREAKER NEC 705.12 BUS BAR RATING x 1.2-MCS RATING=MAX ALLOWABLE PV BREAKER SELECTED PV BREAKER 5 MAX ALLOWABLE PV BREAKER
225A x 1.2-200A=70A 30A s 70A SHEET NUMBER
TEMP QTY OF CURRENT MINIMUM CONDUCTOR CONDUCTOR REQUIRED CIRCUIT NEUTRAL
WIRE ID EXPECTED W1R DERATE CARRYING CONDUIT FILL CONDUIT SIZE WIRE GAUGE& MPACITY @ 90" AMPACITY @ CONDUCTOR AMPACITY ADJUSTED CONDUCTOR CONDUCTOR GROUND WIRE
TEMP("C) (90-C) CONDUCTORS DERATE (TBD ON SITE) TYPE (A) 75°C(A) (A) AMPACITY @ 90"C(A) SIZE&TYPE SIZE&TYPE PV-04.1
1 30 1.00 1 2 1 3/4"METAL #10THWN-2 40 35 25.85 40.00 NONE #10THWN-2
AHJ STAMP
LABELING DIAGRAM. MAIN SERVICE PANEL
O
O
AC DISCONNECT
UTILITY METER O
11 O
0
(INTERCONNECTED
BREAKER)
O
STRUCTURAL STAMP
O C
ELECTRICAL SHOCK HAZARD rHOT_nvoLT'Alc,vsrEva cIRCUj'-..ACKFE
O • • •
TERMINALS ON LINE AND LOAD 9 • •
SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
• • PROJECT NAME
OWARNING CAREY LEANORD&DARLENE
_ FAIRBANKS
131 E WOODLAND DR,SHELTON,
CONNECTION
RAPID
SHUTDOWN
• • WA9B584
3605844661
LAR
• • • PV SYSTEM -ey.Ieenord@yanoo.mm
APN ik 420125100006
OVERCURRENT DEVICE AHJ:MASON COUNTY
UTILITY:MASON COUNTY PUD 1 ZONE 2
B REVISIONS
O SOLAR PV SYSTEM EQUIPP REV DESCRIPTION DATE
THIS EQUIPMENT FED BY PHOTOVOLTAIC _ WITH RAPID SHUTDOWN
MULTIPLE SOURCES TOTAL O4VXI MUM AC•- - M.: AMPS
RATING OF ALL OVERCURRENT NOMINALOPERATING • 240 VAC
DEVICES EXCLUDING MAIN POWER
SUPPLY SHALL NOT EXCEED
TURN RAPID SHUTDOWN
AMPACITY OF BUSBAR SHEET TITLE
SWITCH TO THE"OFF"
POSMON TO SHUT DOWN WARNING LABELS
PV SYSTEM AND REDUCE
SHOCK HAZARD IN THE
ARRAY. L-Ll DRAWN DATE 3/5/2024
DRAWN BY VGN
SHEET NUMBER
PV-05
DIRECTORY PLACARD: AHJ STAMP
STRUCTURALSTAMP
CAUTION
MULTIPLE SOURCES OF POWER.
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AS SHOWN:
ADDRESS:131 E WOODLAND DR,SHELTON,WA 98584
PROJECT NAME
LU
tA CAREY LEANDRO&DARLENE
0 FAIRBANKS
2 Z 131 E NUODLAND DR,SHELTON,
® 0 WA 88584
3605844661
Z camy.leanord@yahm.mm
O O APN a 420125100006
C AHJ:MASON COUNTY
W
LL UTILITY:MASON COUNT/PUD 1 ZONE 2
REVISIONS
UTILITY METER REV DESCRIPTION DATE
AC DISCONNECT MAIN SERVICE PANEL
SHEET TITLE
DIRECTORY
PLACARD
DRAWN DATE 1 3/5/2024
DRAWN BY VGN
SHEET NUMBER
PV-05.1
7 SEG wyn6egsplar<pm. SEG
6 U L A R S O L A R YUKON Series SEG-XXX-BMD-HV(108Ce11s)
ENetrical ChwacfA latlea
Moaraklyp 6EG+tOpaM0.NV sFc+os.eLo-sry ..t.....i.. sEva+seMo.NV
Y U KO N Series BT` N«T �` 31 N"
Maalm.m power-PmpOYI a00 30, a05 30a 4t0 ]OB 415 ?tt
Upen Lircun VoneBe'V�NI 37.Q 3aH 3131 34.)] 37]2 31.81 ]7.az 3a 90
Gaaa funa,t-WN
13.70 fi0I +180 fi.15 1380 a33
Half-Cell Monofacial Module .�:`-` � MYIm,mF,w<rB,„„e�mPr„ ,aB, 2682 3BB3 29.8+ JrpS 29a5 3+,6 �,s
mrrm Prmc,Cunnrrt arnppa i299 qa1 1310 10.51 +3.2t 10.59 1B32 +O.6fi
Moau4Ear11STC9mttii ZOOS 30.71 31W 2t2e
400-415W 21.25% Pm TTaa"aqw,
um System vnnn0e ,SOON a
M-Efficency Ma.+mr.m 6enea r�aa RannB 2sa
Mechanical specifications Technical Drawing
EMe+nal Dlnsion 1T22 a"M a 30 mm "
wmgm 21.5 kg h
Key Features Solar Cells PERC Mono 182 a91mm(108 pcs) I r _.
�`\ Hlgh module corrverslon )(,�� Better temperature Front Glass 3.21 mm AR coating tempered glass I low Iron
Cid effiz1 Cy v��J c C1pnt Feme ENack ano Oat alumimum silo/
�6 II
A,n .n Box IP6813 diodes
Super muhl basher O Wow attenuation bng con for Type MC4
technology moray
Cable Type I Length 12AW PVVAre IULI n200 mm 2
Mechanical Loadl1roMl 5400 Pe I M tP .. ;
Superior load . Ae—Ih appearance
y capacity Mechanical LoadlReaO 3600 Pa/75 psr
ouston,Teaaa based
USA Ileblliry O H
+n,uranccDaaetl L� ompany
Packing Configuration -f- 3A4aaa
2. P 40'MO .rew.�rr.r.r
Warranty Product Certification Pie_¢a pw Pauel 36 36 HV cO
Pallets per Contal 6 26
Aaelrwm.t v.k,.FAm U..,w.,.wmy IEcvQts2ore.rEc vn3o.2oty.a-nm:usmarnrctc
�{93 B% IEC6z80a pip Pieces per Comalrrer 216 936
IEce". .1 MM
^��0'3% IECB27W AmmorYe
\ RnaUnca
I ��p¢I\�-�)55% IEC61216 EC5006a pup ene Sala
e% Fr, Temperature Characteristics
Herkpnc
e Tqe BA61730),T p l P.m Temperature COefi<Ie,n -0.35%Pc
s o ✓, to n ISOta001]015:15ggpp12t116',ISG5o0r.70t0
Voc Tempemare Coef6cimt -0.27 9VC
® CE ♦rcEc �, N,T—Pe,.l—C—M—nl o.os%-e
� e,a.<aPr,n.ra.
Ope,ating Temperature Ao-.As'e
Nominal Operadml Celt Tarr a lu (NOCT) 45t2•C
A—SEG—
- s e Naaaq mavR nipn - P :tiry - W W W.fagSda,.COT
The eumparry haadpvert. te.ea.+< i � Ilai,. blew tie. rl,I..menace t.SEG_ z02302_Rcyq_EN
hem<upomery ranan nWt nnam:nets ena;nrmrprnotnnnt
Lpl1��@5 Open Energy For All
�--/ Technical Specifications
Model H M-120ONT H M-1500 N T
Input Data(DC)
Commonly used module power(W) 240 to 405- 300 to 505�
Maximum input voltage M 60
MPPT voltage range M 16-60
Start-up voltage(V) 22
Maximum input current(A) 4 x 11.5 4 x 11.5
_ Maximum Input short circuit current(A) 4 x 20
Number of MPPTs 2
Number of inputs per MPPT 2
Output Data(AC)
Peak output paver(VA) 1200 1200 1500 1500
Maximum continuous output power(VA) 1200 1200 1438 1438
Maximum continuous output current(A) 5.00 5.77 5.99 6.91
Nominal output voltage/range(W 240/211.264 208/183-228 240/211-264 208/ln228
Nominal frequency/range(H# 60155-65
Power factor(adjustable) >0.99 default
(,.8 leading...0.8 lagging
Microinvefter Description Total harmonic distortion <3%
Hoymiles 4-in-1 mlcroinverter is one of the most cost-effective Maximum units per 10 AWG branch? 4 4 4 3
Datasheet module-level solar solutions,as it can support up to 4 panels at Efficiency
once and maximize the PV production of your installation.With a CEC peak efficiency 96.7%
maximum DC voltage of 60 volts,Hoymiles microinverter is a PV
Rapid Shutdown Equipment and conforms with NEC-2017 and CEC weighted efficiency 96.5%
NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. Nominal MPPT efficiency 99.8%
H M-1200 NT Nighttime power consumption(mW) <50
H M-150ONT Both models listed are equipped with reactive power control and
can meet the requirements of IEEE 1547,UL 1741 and CA Rule21. Mechanical Data
Ambient temperature range(°C) -40 to-65
Dimensions(W x H x D mm) 280 x 176 x 33
..._..._ _.. ___._ Weight(kg) 3.35
Features Enclosure rating Outdoor-NEMA 6 QP67)
Cooling Natural convection-No fans
1m Easy installation,just plug and play Features
External antenna for stronger
communication with DTU Communication 2.4 GHz Proprietary RF(Nordic)
With Reactive Power Control,compliant Type of isolation Galvanically Isolated HF Transformer
with CA Rule 21 Monitoring S-Mlles Cloud'
s High rella6iliry:NEMA 6(IP67)enclosure,
® Compliant with U.S.NEC-2017&NEC-2020 6000 V surge protection Warranty Up to 25 years
690.12 rapid shutdown UL 1741,IEEE 1547,UL 1741 S8,UL 1741 SA(240 VacJ CA Rule 21(240 Vac)•,
Compliance CSA C22.2 No.107.1-16,FCC Part 15K FCC Part 15C
PV Rapid Shutdown Conforms with NEC-2017 and NEC-2020 Article 690.12
and CEC-2021 Sec 64_218 Rapid Shutdown of PV Systems
•1 Nominal vokage/frequency range can vary depending on local requirements.
•2 Refer to local requirements for exact number of microinveners per branch.
•3 Hoymiles Monitoring System
•4 The HM-150ONT microUrverter complies with both CA Rule 21(240 Vac)and CA Rule 21(208 Vac).
02024 Hoymles Power Electronics Inc M rights reused.
k r5w 17ve Open Energy For All
•�'���� Technical Specifications
Model HM-60ONT HM-700NT HM-800NT
Input Data(DC)
Commonly used module paver(W) 240 to 405+ 280 to 470+ 320 to 540+
Maximum input voltage M 60
MPPT voltage range M 16.60
Startup voltage M 22
Maximum Input current(A) 2 x 11.5 2 x 11.5 2 x 12.5
■v v e r r�� Maximum Input short circuit current(A) 2•20
■° r Number of Ni 2
v a Number of inputs per MPPT 1
D
Output Data(AC)
` Peak output power(VA) 600 700 800
Maximum continuous output power(VA) 590 6% 766
Maximum continuous output current(A) 2.46 2.94 2.90 3.35 3.19 3.68
Nominal output voltage/range M' 240/211.264 208/183-228 240/211464 208/183-228 240/211-264 2091183-228
Nominal frequencyhange(Hz)' 60/55-65
>0.99 default
Paver factor(adjustable) 0.8 leading...0.8 lagging
Total harmonic distortion <3%
Microinverter Description Maximum units per 10 AWG branch' 9 8 8 7 7 6
Maximum units per 12 AWG branch' 6 5 5 4 5 4
Datasheet Hoymiles 2-in-1 mlcroinverter Can connect up to 2 panels at Efficiency
once and maximize the PV production of your installation.With CEC peak efficiency 961%
a maximum DC voltage of 60 V,Hoymiles mkroirwerter i5 a PV CEC weighted efficiency 96.5%
Rapid Shutdown Equipment and conforms with NEC-2017 and Nominal MPPT efficiency 99.8%
H M-60O NT NEC-2020 Article 690.12 and CEC-2021 Sec 64-218. Nighttime power consumption(mM <50
Mechanical Data
H M-700NT All of the three models listed are equipped with reactive power Ambient temperature range('p .0to+65
H M-80ONT control and can meet the requirements of IEEE 1547.UL 1741 Dimensions(w>H•D Immp 250.170.29
and CA Rule21. weight(kg) 2.6
Enclosure rating Outdoor-NEMA 6 UP67)
Coding Natural convettial-No fans
Features
Features Communication 2A GHz Proprietary RF INordiq
Type of isolation Galvanically Isolated HF Transformer
Easy Installation,just plug and play m External antenna for stronger Monitoring S-Mlles Ooud'
1 communication with DTU
Warranty lip to 25 years
m With Reactive Power Control,compliant UL 1741.IEEE 1547,UL 1741 SAR40Vac),UL 1741 SO.CARule 21(240 Vaq',
with CA Rule 21 Compliance
High reliability:NEMA 6(IP67)enclosure, C5A C22.2 No.107.i-16,KC Part 202 KC Part 15C
m 1 Conforms 21 S NEC-2017 and NEC-2020 Article Systems
Compliant with U.S.NEC-2017&NEC-2020 6000 V surge protection PV Rapid Shutdown
1 690.12 rapid shutdown and CEC 2021 Sec 64218 Rapid Shutdown M PV Systems
•1 Nominal vo8age/frequency range can vary depending on local requirements.
•2 Refer to local regmrements for exact number of mlcro,verters per branch.
•3 Hoymiles Monitoring System
•The HM-800NT mk:roirNerter complies with bath CA Rule 21(240 Vac)and CA Rule 21 ROB Vac).
+.:Y.., m "' 02024 H.Wxks Power Ekctronks Inc AN riyns reserved.
h�l Im�leS Open Energy For All
J�1 Technical Specifications
Model HM-30ONT HM-35ONT HM-40ONT
Input Data(DC)
Commonly used module power(W) 240 to 405+ 280 to 470+ 320 to 540«
Maximum input voltage M 60
MPPT voltage range M 1660
Start-up voltage(V) 22
e - Maximum input current(A) 11.5 11.5 12.5
Maximum input short circuit current(A) 20
Number of MPPT 1
Number of inputs per MPPT 1
e Output Data(AC)
Peak output power(VA) 300 350 400
a Maximum continuous output power(VA) 295 349 382
Maximum continuous output current(A) 1.23 1.42 1.45 1.68 1.59 1.84
Nominal output voltage/range M' 240/211-264 208/183-228 240/211.264 2MI83-228 2401211-2b4 208/183-228
Nominal frequency/range(HZ)' 60/55-65
-
Power fact >0.99 defaultor(adjustable) 0.8 leading...0.8 lagging
Total harmonic distortion <3%
Maximum units per 10 AWG branch' 19 16 16 14 15 13
Microinverter Description Maximum units per 12 AWG branch' 13 11 11 9 10 8
Efficiency
Datasheet Hoymiles 1-in-1 microinverter,which can be connected to one CEC peak efficiency 96.7%
panel and used in various applications,is one of the most CEC weighted efficiency 96.5%
flexible solar solutions.With a maximum DC voltage of 60 V. Nominal MPPT efficiency 99.8%
-- - - Hoymiles microinaerter is a PV Rapid Shutdown Equipment and
<50
conforms with NEG2017 and NEC-2020 Article 690.12 and Nighttime power consumption(mW)
HM-300N CEC-2021 set 64-218. Amble Mechanical Data
' HM-35ONT Ambient temperature range(°q -40 to+65
All of the three models listed are equipped with reactive power Dimensions(W x H x D[rnm]) 182 x 164 x 29.5
H M-40O NT control and can meet the requirements of IEEE 1547,UL 1741 Weight(kg) 1.75
and CA Rule21. Enclosure rating Outdoor-NEMA 6 UP67)
Coding Natural convection-No fans
Features
Communication 2.4 GH2 Proprietary RF(Nordic)
Features Type of isolation Galvanically Isolated HF Transformer
Monitoring S-Miles Cloud'
m Easy installation,just plug and play m External antenna for stronger Warranty Up to 25 years
communication with DTU
m Compliance UL 1741,IEEE 1547,UL 1741 7.(240 Vac)Part
178,FCC
Pa Rule 5 21 1240 VacY,
r With Reactive Power Control,compliant CSA C22.2 No.107.1-16,FCC Part 158,KC Part 15C
with CA Rule 21 Conforms with NEC-2017 and NK-2020 Article 690.12
High V surge NEMA 6 IP67 enclosure, PV Rapid Shutdown
9 reliability: ( ) and CEC-2021 Sec 64-21 B Rapid Shutdown of PV Systems
Compliant with U.S.NEC-2017&NEC-2020 6000 V surge protection
r 690.12 rapid shutdown •1 Nominal voltage en range can vary depending on local requirements.
"2 Refer to local requirements
for exalt number of microlnverters per branch.
*3 Hoymiles Monitoring System
"4 The HM-40ONT microlnverter complies with bah CA Rule 21(240 Vac)and CA Rule 21(208 Vac).
02024 Hoymiles Paver Eleoronics Inc.An rgtxs—r-1.
CHIK,( A CHIKQ
Solar Mounting Solutions LSolar Mounting Solutions
PRODUCT LINE PRODUCT LINE
Item Product Name Item Product Name
CK-FT-R537B2-2400 CHIKO 537 Black Rail 2400mm CK-637-1-200 CHIKO 537 Rail Splice Kit
CK-FT-R537B2-3500 CHIKO 537 Black Rail 3500mm
CK-FT-R537B2-4700 CHIKO 537 Black Rail 4700mm
TECHNICAL DATA
Main Material AL 6005-T5
TECHNICAL DATA Wind Load Up to 60 M/S
Main Material AL 6005-T5 Snow Load 1.4 KM/Mz
Wind Velocity Up to 60 M/S T
Xi=31918.082 mm4 30.4 49mm
#537 RAIL Yi=81501.592 mm4 #537 RAIL SPLICE KIT
CHIKO537R aluminum rail is designed for CHIKO aluminum rail splice kit is /
roof mounting system,it could be applied designed for 537R rail connection from back
on all roof mount system.A variety of lengths to position.Move easily and economically
can help to reduce unnecessary cut. N to install the rails.
D
ADVANTAGES
■ Easy installation ADVANTAGES COMPONENT LIST
■ Highclass anodized ■ Easy installation
■ Tilt-in nut COMPONENT LIST . Highclass anodized MATERIAL OTY
Aluminium Rail Splice Kit Ot
■ Universal on roof mount system MATERIAL p7Y
Aluminium Rail 01 SUS304 Inner Hexagon M8`12 02
SUS304 Star Washer M8 02
WARRANTY WARRANTY SUS304 Hexagon Thin Nut M8 02
ORDERING SPECIFICS ORDERING SPECIFICS
Standard Packaging 8pcs/unit Standard Packaging 50PCS/BOX 200PCS/CTN
320/384/504 pcs per pallet Dimensions 50'38`20CM
im * Dimensions 2400/3500/4700 mm Weight 30kg
Weight 14/20/26 kg
:• . :0
CHIKQwww.chikolar.com/www.chikousa.comCHIKS
Solar Mounting Solutions L Solar Mounting Solutions
PRODUCT LINE PRODUCT LINE
Item Product Name Item Product Neme
CK-777R537 KS(30.45)D-40 CWO Grounding Universal Black Wid Clertp 30-50mm For 537R CK-750R531.30r42.0301.40 CHKO Intergated Grounding Black End damp UnKwsal 30-42mm
TECHNICAL DATA TECHNICAL DATA
Main Material AL 6005-T5 Main Material AL 6005-T5
Te
o
D=30-50
Universal Grounding Mid Clamp Universal Grounding End Clamp D=30-42
CHIKO Universal Grounding Mid Clamp is CHIKO End Clamp is designed base on 537R
designed for 537R Black Rail,available for solar
rail to fix module on the end of rail,have
panels with thickness from 30.50mm.
COMPONENT LIST founction of Intergated grounding,30mm
MATERIAL CITY to 42mm thickness module are available. COMPONENT LIST
Black Mid Clamp 01 MATERIAL OTY
ADVANTAGES SUS304 Bolt M6 01 ADVANTAGES i End Clamp AjB 01
■ Intergated Grounding SUS304 069 Nut 01 ■ Intergated Grounding SUS 304 Bolt M6 01
■ Easy installation Rivet 02 ■ Easy installation SUS304 Nut 01
■ High class anodized Spring 01 ■ High class anodized SUS304 Spring Washer M6 01
■ Tilt-in nut ■ Tilt-in nut SUS304 Washer M8 01
Adjustable range 30-50mm Plastic Plate 01 ■ Adjustable range 30-42mm Rivet 01
■
ORDERING SPECIFICS
ORDERING SPECIFICS Standard Packaging 80PCS/BOX 320PCS/CTN
Dimensions 50'38'20CM
Standard Packaging 8OPCS/BOX 320PCS/CTN
Weight 32kg
Dimensions 50'38'20CM
Weight 24kg
•
CHIKQ
Solar Mounting Solutions
PRODUCT LINE
tem Product Name
CK-592R537-1-120 CHIKO Grounding Lug For#537 Rail
�F
TECHNICAL DATA
Main Material AL 6005-T5
Tighten torque 15N.m
Safe torque 20N.m
CD
Grounding Lug
CHIKO grounding lug is designed for fixing
grounding cable going through smoothly
between each rails.
t*
COMPONENT LIST
ADVANTAGES MATERIAL CITY
Grounding Lug 01
• Easy installation SUS304 Inner Hex Bolts M8'20 02
■ High class anodized SUS304 554 Nut 01
■ Tilt-in nut SUS304 Star Washer 01
SUS304 Inner Hex Bolts M8'25 01
SUS304 Spring Washer 01
SUS Square Nut M8 01
WARRANTY ORDERING SPECIFICS
Standard Packaging 140PCS/BOX 560PCS/CTN
.' Dimensions 50'38'20CM
Weight 29kg
m mm.
s0
/fir. IRONRIDGE QuickMount L-Mount" L-Mount Installation Instructions
Installation Tools Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compoflhly with roofing
Roof Protection without Compromise materials,drill with 7/32"or 1/8"bit,drill or impact gun with 1/2"socket.
The L-Mount'attachment,featuring an open-slotted
L-Foot,is designed for cost-effective,single-bolt
installation onto existing composition(asphalt)shingle
roofs.The patented Elevated Water Seal Technology"'has
been integrated into the open-slotted L-Foot and flashing r
for fast installation,to provide maximum waterproofing.
To maximize versatility,the mount is available with a lag -
bolt or structural screw option for the strength you depend �\ -v
on.Both hardware options come with an �• ;-- -
installed EPDM bonded washer to seal and
prevent water entry. Locate,choose,and mark centers of rakers to be Carefully lift composition roof shingle with roofing Insert flashing between 1st and 2nd course.Slide
P rY mounted.Select the courses of shingles where bar,just above placement of mount. Remove up so top edge of flashing Is at least 3:"higher
mounts will be placed. nails as required and backfill holes with aproved than the butt-edge of the 3rd course and lower
L-Mount features a 9x1 2"aluminum flashing sealant.See"Proper Flashing Placement"on next flashing edge is above the butt-edge oflstcourse.
with alignment guides and rounded corners, page. Mark centerforddlling.
to easily slide under shingles and speed up
installation on the roof.The kit is available in Elevated Water Seal Technology®
both mill and black finishes. This proprietary flashing design cleverty places the root penetration seal onto an
_ a.
aluminum flute(used into ine flashing,above
This component is art
>° _ the bolt hole,The secondary EPDM rubber
P 1" f seal keeps water ouf—raised above the path
of the QuickMount- r f _ of rain water and out of harm's way.
product line.
If attachingwith lag bolt use A,"bit(Lag).Use Clean offany sawdust,and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to
_ 'S"bit(ST)for attaching with the structural screw. compatible with roofing materials. desired orientation.
Drill pilot hole Into roof and rafter,taking care to
drill square to the roof.Do not use mount as a drill
guide.Drill a 2"deep hole into rafter.
mg manufacturers'
All roof
written instructions must also be
t _-=_c = •
followed by anyone modifying
Zl
a roof system.Consult the
roof manufacturer's specs a"d
Y
Pre-Installed Sealing Washern in
Harware options include a lag bon or _
struclural screw.The EPDM washer - the roof.
amves already attached.
Open-Slotted L-Foot
The redesigned L-Foot can rotate 360
degrees for optimal adjustabilny end Prepare lag bolt or structural screw with sealing You are now ready for the rack of your choice.
positioning of the rail,while the open washer using a'h-inch socket on an impact gun, Follow all the directions of the rack manufacturer
�� slot allows the rail hardware to quickly drive prepared lag bolt through L-foot until L-fcot as well as the module manufacturer.NOTE:Make
/gyp-Tw 2SYear Wartanty drop-in and be compatible with any side- can no longer easily rotate.DO NOT ovp-torque. suretop of L-Foot makes solid contact with racking.
-1.%U/ mounted racking on the market. NOTE:Structural screw can be driven with T 30 hex
i/l• Product guaranteed free head bit.
Intertek of impairing defects.
PPlurefight Power
March 08, 2024
Subject: Proposed Solar Panel Installation
Carey Leanord & Darlene Fairbanks Residence, 131 E Woodland Dr,Shelton,WA
To Whom it May Concern,
Our engineering department has reviewed information, gathered by our field crews, related to the proposed solar
panel installation at the above-referenced address. The purpose of our review was to determine the structural
adequacy of the existing roof for the proposed installation. Based on our review and analysis of the available
information, it is our professional opinion that the existing structure requires a retrofit to ensure structural
adequacy to support the proposed installation.
The retrofit shall consist of 2x6 sister for the existing splitting 2x6 rafter as shown in the photos below,with 1/4" dia.
x 3" SDS screws at 12" O.C., staggered. New sister to extend within 12" of existing 2x, only required at existing
member with new solar attachment. Retrofit should happen before install.
Design Parameter Summary
Governing Building Code: 2018 Washington Building Code (2018 IBC)
Risk Category: II
Design Wind Speed: 110 mph (per ASCE 7-16)
Ground Snow Load: 25 psf
Roof Information
Roof Structure: 2x6 Rafters @ 24" O.C.
Roofing Material:Asphalt Shingles(1 layer)
Roof Slope: 22'
Roof Connection Details
Lag Screws: (1) 5/16" diameter min.,with min. 2.5" embedment into framing members, at 48"O.C. max,staggered
Locations per design drawings
Note:Required embedment length excludes the tapered tip of the screw,and embedment into sheathing.
Analysis
The proposed installation complies with the requirements of WAC Section 51-51-03240 R324.4 (Exception) and is
therefore deemed adequate to support the load of the rooftop solar system.
Specifically: 1) the system is designed for the local wind speed; 2) the ground snow load does not exceed 70 psf; 3)
the total dead load of all items is less than 4 psf(actual value is approximately2.75 psf);4) Modules are not mounted
more than 18" off the roof; and 5) Supports are installed such that the dead load is spread across roof-framing
members and does not exceed 50 Ibs at any point.
w .
Wind uplift on the panels has been calculated in accordance with the relevant provisions of ASCE 7-16. This loading
has been used to verify the adequacy of the connection specified above. Connection locations should be in
accordance with design drawings.
Conclusion
When the retrofits detailed in this letter's opening paragraph are performed, the structure will have adequate
strength to support the proposed installation. Connections to the roof must be made per the "Roof Connection
Details" section above. Copies of all relevant calculations are enclosed.
Limitations and Disclaimers
The opinion expressed in this letter is made in reliance on the following assumptions: the existing structure is in
good condition (apart from the damage which shall be repaired or retrofit per the above); the existing structure is
free from defects in design or workmanship; and the existing structure was code-compliant at the time of its design
and construction. These assumptions have not been independently verified, and we have relied on representations
made by the property owner and his or her agents with respect to the foregoing.The undersigned has not inspected
the structure for patent or latent defects.
Electrical engineering is beyond the scope of this analysis. Solar panels must be installed per manufacturer
specifications. Structural design and analysis of the adequacy of solar panels, racks, mounts, rails, and other
components is performed by each component's respective manufacturer and the undersigned makes no statement
of opinion regarding such components. This letter and the opinions expressed herein are rendered solely for the
benefit of the permitting authority(city or county building department), and may not be utilized or relied on by any
other party.
If you have any questions or concerns, please contact our office at (855)-709-1181, or email
Austen.Morfin@solgenpower.com.
Sincerely,
Trevor A.Jones, P.E.
BEN 0 R J 0NF
�oF w_ASy,,NCS
T2
201148 8 Q7
RFGIsT£ G\�
�SS�ONM_EN
3/8/2024
Retrofit Description
The retrofit shall consist of 2x6 sister for the existing splitting 2x6 rafter as shown in the photos
below, with 1/4" dia. x 3" SDS screws at 12" O.C., staggered. New sister to extend within 12" of
existing 2x, only required at existing member with new solar attachment. Retrofit should happen
before install.
Additional Retrofit Details and Notes
(N)PV ATTACHMENT
PER PLAN
�SIMPSON'NIP36'-
�1' bn
A
lS�
(E)SHEATHING (N)2x SISTERED
RAFTER
A
(E)WALL
(N)PV ATTACHMENT
PER PLAN
(E)PLYWOOD
I -
(E)2x PER PLAN - �- (N)2x SISTER %N1 YVO x 3"13DS'SCREWS @ 12"
x O.C.,STAGGERED(NO ADD.HGF.REQ'D.)
(N)2x TO EXTIND REQ'DD 0(E)RAFTER Wr (N)SOLAR ATTACHMENT
SECTION 'A-X
Pictures of poor condition -area to be retrofit (where applies)
r±
PPurelight Power
WA State Exception Criteria - Calculation
This calculation justifies the additional solar load by showing the solar dead load at each
attachment is less than 50 Ibs (WAC 51-51-03240, R324.4, Exception Criteria).
Connection Demand
Spacing perpendicular to rail in 1/2 panel length
Spacing parallel to rail in Max spacing
Solar Dead Load 2.75 psf
Solar DL Point Load 29.79166667 Ibs
OK
PPurelight Power
Ironridge Quick Mount L-Mount Connection Calculation
This calculation justifies the connection of the solar panels to existing roof members, by
showing the connection capacity is equal to or greater than the uplift force demands.
Connection Demand
Spacing perpendicular to rail in 1/2 panel length
Roof Angle 22 degrees
Wind Speed 110 mph
Exposure Coefficient, KZ - 0.57
Topographic Factor, K, 1
Directionality Factor, Kd 0.85
Elevation Factor, Ke _0.99
Velocity Pressure,qZ 16.0 psf
Prying Coefficient 1
Zone 1 Zone 2r Zone 3
Spacing parallel to rail 48 48 48 in Max spacing
Effective Wind Area on each connection 10.8 10.8 10.8 ft2
GCp(max) 1.90 1.97 1.97
Exposed Panels?(YE=1.5) No No No
Pressure Equalization Factor,ya 0.79 0.79 0.79
Uplift Force 23.9 24.8 24.8 psf
Max. Uplift Force/Connection (0.6 WL) 155.0 161.3 161.3 Ibs
Solar Dead Load (0.6 DL) 17.9 17.9 17.9 Ibs
Max. Uplift Force(0.6 WL-0.6 DL) 137.2 143.4 143.4 Ibs
Connection Capacity Ironridge Quick Mount L-Mount
Fastener Type Lag Screw
Fastener Diameter 0.3125 ]in
Embedment Length, min 2.5 in
Lumber Species&Grade DFL#2(Assumed)
Lumber Specific Gravity 0.5
Nominal Withdrawal Capacity,W 665.0 Ibs NDS 12.2-1
#of Screws
Load Duration Factor,CD 1.6
Adjusted Withdrawal Capacity,W' 1064.0 Ibs
Compare Adjusted Withdrawal Capacity to ASD Factored Demand
Zone 1 Zone 2r Zone 3
O.K. O.K. O.K.