HomeMy WebLinkAboutCOM2006-00090 Cancelled ReRoof see PN 123325000031 - COM Permit / Conditions - 1/27/2007 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)427-7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext.352
Shelton, WA 98584
COMMERCIAL BUILDING PERMIT COM2006-00090
OWNER: CARL EHRESON RECEIVED: 7/27/2006
CONTRACTOR: CLOISE & MIKE CONSTRUCTION INC LICENSE: CLOISMC991 LZ EXP: 7/22/2008 ISSUED: 7/27/2006
SITE ADDRESS: EXPIRES: 1/27/2007
PARCEL NUMBER: 123201391072
LEGAL DESCRIPTION: TR 7-B OF N1/2 SW NE TR 2 OF SP #1961
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
Re-Roof State Rt. 3 to address.
General Information Construction &Occupancy Information
Type of Use: Insp.Area:
No. of Units: Type of Constr.:
No. of Bathrooms: Occ. Group:
Type of Work: RRF Fire Dist.: 2 No. of Stories: Occ. Load:
Valuation:
Building Height:
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building:
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline & Planning Information
Front: Ft. Shoreline: Ft.
Rear: Ft. Slope: Ft. Water Body: Shoreline Desig.:
Side 1: Ft. SEPA?: Comp. Plan Desig.:
Side 2: Ft.
Fire Protection System Information
Auto Fire Alarm System?: Emergency Key Box?: Standpipe?:
Auto Fire Sprinkler System?: Access Road?: Fire Extinguishers?:
Fixed Fire Suppression System?: Fire Hydrants?: Fire Lanes?:
COM2006-00090 Please refer to the following pages for conditions of this permit. 1 of 4
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Re-Roof Fee KKK 7/77/,?nna tv)n 5n R1gnnRnn
Building State Fee KKK 7177nnnR u 5n Ri9nnRnn
Total $125.00
CASE NOTES FOR
COM2006-00090
CONDITIONS FOR
COM2006-00090
1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
x T<--
2) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647-09 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X
3) PURSUANT TO INTERNATIONAL CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY
BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION
FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE INTERNATIONAL CODE WILL BE ASSESSED IF
OWNER/ ONTRACTOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
4) ENCLOSED ROOF SYSTEMS THAT ARE EXPOSED TO THE SHEATHING SHALL BE INSULATED TO A MINIMUM R-30 AND INSPECTED
PRIOR TO COVER. X_1—C__
5) SINGLE RAFTER JOIST ROOF REPLACEMENT SHALL BE INSULATED TO A MINIMUM OF R-30 ALLOWING FOR A MINIMUM OF ONE INCH
CONTINUOUS VENTED AIRSPACE ABOVE THE LEVEL OF INSULATION. X n�
6) Per 2003 IRC - SECTION 1609-WIND LOADS- 1609.1 Applications. Buildings, structures and parts thereof shall be designed to withstand the
minimum wind loads prescribed herein. Decreases in wind load shall not be made for the effect of shielding by other structures. Per FIGURE
1609 BASIC WIND SPEED (3-SECOND GUST) the wind speed for Mason County is 85 MPH.
X'rL
7) Per 2003 IRC - SECTION R905 - REQUIREMENTS FOR ROOF COVERINGS - R905.1 Roof covering application. Roof coverings shall be
applied in accordance with the applicable provisions of this section and the manufacturer's installation instructions.
X `-C
8) A Class "A" roof assembly shall be installed and verified by manufacturer specifications during the inspection of this project.
x TL
COM2006-00090 2 of 4
9) ALL CONSTRUCTION MUST MEET OR EXCEED ALL LOCAL CODES AND THE INTERNATIONAL CODE REQUIREMENTS AND
OCCUPANCY IS LIMITED TO THE PERMITTED AND APPROVED CLASSIFICATION. ANY CHANGE OF USE OR OCCUPANCY WOULD
RESULT IN PERMIT REVOCATION. CHANGE OF USE MUST BE APPROVED PRIOR TO CHANGE. x (L
10) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-col't with Mason County ordinances and building regulations.
X
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of
work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described property and structure for review and inspection.
OWNER OR AGENT: II O w, C�6LiC-- DATE: 7 `2 7 — 04
COM2006-00090 3 of 4