Loading...
HomeMy WebLinkAboutGRD2010-00003 Expired - GRD Inspections - 7/20/2023 i7 o CONCRETE MECHANICAL MANUFACTURED HOME OD _ r N) Date c oFootings/Setbacks Gas Piping By Ribbons - DTI o Intenor Date By interior-Date By Date By -� oExtenor Date By Exterior-Date B Set-uP D w Point Load!Isolated Footings INSULATION Date By 0 BG 1 SLAB INSULATION X Date By Date By FIRE DEPARTMENT p Foundation Walls Floors Date By m Date By Data By DECKS FRAMING Walls Date By m Date By Data By PROPANETANKS Cl) PLUMBING vault Date By r Date By OTHER C) Groundwork Attic Date By Type, Date B y Date By D.W.v DRYWALL Type Int Brace Wall Date By CDy � Date 8 Date By FINAL INSPECTION Water Line roilr',91 SeperationDate By By Date By O Pass or Request Inspect. c Type of Insp. Fail Date Date Done By Comments c a 0 a o . a Cn O S N (D 3 .'L A O A Inspection Line(360�27-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: tion Line ( 60) ext.262 Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Shelton,WA 98584 LAND MODIFICATION BUILDING PERMIT GRD201O-00003 OWNER: BLUE STAR PROPERTIES L.L.0 CONTRACTOR: LICENSE: EXP: RECEIVED: 1/19/2010 ENGINEER: APPEX ENGINEERING PLLC 1.253.473.4494 LICENSE: EXP: ISSUED: 3/19/2010 SITE ADDRESS: NE LOG YARD RD BELFAIR EXPIRES: PARCEL NUMBER: 123211300010 LEGAL DESCRIPTION: SW NE WILY OF R.R. R/W EX PROJECT DESCRIPTION: DIRECTIONS TO SITE: Clearing and Grading 874714 cy for the installation of a regional storm ST RT 3 TO BELFAIR GO PAST THE OVERHEAD RR TRACTS,L ON drainage facility. LOG YARD RD TO SITE THAT IS ADJACENT TO 431 NE LOG YARD RD Inspection Area: Fill?: Yes Comp. Plan Desig.: Urban Growth Grading?: Yes IRO Desig.: Cutting?: Yes Shoreline Desig.: Not Applicable Area Graded: 20.00 Acres SEPA?: Yes Cubic Yards: 874,714.00 FEES Type By Date Amount Receipt Grading Plan Check Fee GMM 1/19/2010 $1,383.14 S12010000 Planning Stormwater GMM 1/19/2010 $255.00 S12010000 Grading Permit Fee DLC 2/24/2010 $5,842.97 S12010000 Building State Fee DLC 2/24/2010 $4.50 S12010000 ADJUST--Grading Plan DLC 2/24/2010 $5.95 S12010000 Total $7,491.56 GRD2010-00003 Please referto the following page(s)for conditions ofthis permit. 1 of 4 CONDITIONS FOR GRD2010-00003 1) ALL CLEARING,CUTTING, GRADING, EXCAVATING, TERRACING, FILLING AND SIMILAR WORK WILL BE REGULATED BY THE REQUIRF-MENTS PURSUANT TO THE MASON COUNTY GRADING PERMIT STANDARDS ADOPTED BY RESOLUTION 141-96 and MASON COUN CODE, TITLE 14, CHAPTER 14.44. 1 X 2) All fills shall be compacted to a minimum of 90 percent of maximum density.X � 3) A 20 foot wide fire apparatus access road is required to extend within 150 feet of any portion of the exterior walls of the building. An unobstructed vertical clearance of 13 feet, 6 inches is required. Dead-end fire apparatus-access roads longer than 150 feet are required to have an approved turnaround. The maximum grade of a fire apparatus access road is 14%. X L 4) The owner/applicant shall provide to Mason County inspection reports prepared by the engineer record, complying with the requirements as noted in Chapter 14.44, section 14.44.220 through 14.44.230. Inspection reports shall be submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584. Final approval of the project is dependent upon receipt of all inspection reports. X 4 5) Cut and.fill slopes shall be setback from site boundaries in accordance with Section 14,44.190. X 4L) 6) Approved per site plan and topographic cross-section. X ; 7) It is unlawful to dispose of or to bury any type of solid waste. This includes but is not limited to scrap metal, wood pieces or particles generated as a by-product or waste from the manufacturing of wood products, construction, storm or demolition debris, or other raw materials such as trees and stump X 8) Compliance with an approved Storm Water Plan shall be subject to an on site inspection, or inspections, by the engineer of record or an authorized representative. Said inspection(s) shall be performed in accordance with the approved plan, and prior to any modification that would make a determination of compliance impossible. Inspection reports shall be submitted to verify all engineering requirements have been completed in accordance with the approved storm water plan. Reports 5hall be submitted to the Mason County Department of Community Development prior to each corresponding inspection and final permit appr Copies of all special inspection reports shall be made available at time of inspection. X 9) ALL SURFACE WATER AND POTENTIAL RUNOFF WILL BE CONTROLLED ON SITE AND SHALL NOT ADVERSLY AFFECT ANY ADJACENT PROPERTIES NOR INCREASE THE VELOCITY FLOW ENTERING OR ABUTTING TO ANY STATE OR COUNTY CULVERTING/DITCHING SYSTEM OR ROAD WAYx GRD2010-00003 Please refer to the following page(s)for conditions of this permit. 2 of 4 10) Tempor Erosion control measures must be implemented to prevent water quality degradation of adjacent waters or wetlands. X 11) An inspection performed by a representative of the geologist or their authorized representative shall be completed on-site prior to the footing pour to observe excavation of the infiltration system to verify that suitable soils have been exposed as specified in the soils report prepared by GeoResources, LLC dated April 23, 2009. Reports shallbe submitted to the Mason County Building Dept., PO Box 186, Shelton, WA 98584 prior to the request for final inspection. X ) _T. 12) Access Roads to the site must not be degraded as a result of work. X ) 13) Owner t is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 14) The applicant shall place fill on the subject parcel and company-owned parcels in a safe manner and in accordance with the submitted Jan. 2010 stormw a plan. X _��_T The applicant shall secure the proper grading or land modification permits prior to placing excess or cut materials on properties other than the subject parcel t �ompany-owned parcels. X This permit becomes null and void if work orconstruction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of Conti nation of work is a prog s inspection within the 180 day period. Final inspection must be approved before building can be occupied. OWNER OR AGENT: DATE: GRD2010-00003 Please refer to the following page(s)for conditions of this permit. 3 Of 4