Loading...
HomeMy WebLinkAboutBLD2013-00033 Final Change Portion of Carport to 2nd Bedroom - BLD Permit / Conditions - 3/13/2013 Inspection Line (360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670, ext. 352 Mason County Bldg. III 426 W. Cedar P.O. Box 279 Shelton, WA 98584 i� RESIDENTIAL BUILDING PERMIT BLD2013-00033 OWNER: GLENN MILLER RECEIVED: 1/11/2013 CONTRACTOR: LICENSE: EXP: ISSUED: SITE ADDRESS: 1151 NE OLD BELFAIR HW 1/31/2013 Y BELFAIR EXPIRES: /31/2013 PARCEL NUMBER: 123201391071 LEGAL DESCRIPTION: TR 7-A OF N1/2 SW NE TR 1 OF SP#1961 PROJECT DESCRIPTION: DIRECTIONS TO SITE: CHANGE PORTION OF THE EXISTING CARPORT TO SECOND FROM BELFAIR GO NORTH ON THE OLD BELFAIR HWY 1.3 MILES TO 1151 BEDROOM NE General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: 2 Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: 1 Occ. Group: R-3/U Lot Size: Deck: Type of Work: ADD Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:168 Valuation: $ 17,796.24 Building Height: 17 Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: Ft. Shoreline: Ft. Water Body: - - Rear: Ft. Slope: Ft. SEPA?: Model: Width: Ft. Side 1: Ft. Shoreline Desig.: Year: Serial No.: Side 2: Ft. Comp. Plan Desig.: Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee TW 1/11/2013 $ 190.61 S2201300000001 EH Plan Review KKK 1/11/2013 $ 103.00 S6201300000001 Building State Fee LDK 1/29/2013 $4.50 S2201300000001 Building Permit Fee LDK 1/29/2013 $293.25 S2201300000001 Total $591.36 BLD2013-00033 Please refer to the following pages for conditions of this permit. Page 1 of 4 CASE NOTES FOR BLD2013-00033 CONDITIONS FOR BLD2013-00033 1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-098 2. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X 2) Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 3) Owner/builder assumes all responsibility if drainfield/reserve area is encumbered. A. Drainfield/ Reserve requires a 1 Oft setback from all footing/foundations. B. Septic tank(s) requires 5ft setback from all footing/foundations. C. No foundation drains within 30ft, down gradient of drainfield/reserve area. X - 4) All approved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will _. . not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 5) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 6) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, FIRM-NATIVE SOIL. X BLD2013-00033 Please refer to the following pages for conditions of this permit. Page 2 of 4 7) Washington State Energy Code Compliance has been approved as follows: Heat Type: Electric or other than electric, Compliance Method: Prescriptive option III, Window(Max U-Factor):0.30, Skylight(Max U-Factor):0.50, Doors (Type/Max U-Factor):0.20 or less, Wall insulation R-21, Floor insulation R-30, Ceiling Insulation R-38 advanced or R-49 standard, Vault Insulation R-38, and Slab Insulation R-10. In addition the following credit from Table 9-1 shall be completed: 6 X 8) A minimum of 50 percent of all luminaires shall be high efficacy luminaries unless lighting compliance was approved using the options available in WSEC Section 1520 or 1530. Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaries unless permanently installed outdoor luminaires are controlled by a motion sensor(s)with integral photocontrol photosensor or installed in or around swimming pools or water features. All fluorescent fixtures must be fitted with T-8 or smaller lamps (but not T-10 or T-12 lamps). Reference WSEC 505. X 9) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X 10) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington: Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X 11) Provisions for surfacelsubsurface drainage control must be implemented with newconstruction or development on site and MUST NOT adversely impact adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25' of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X 12) Placement of structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. Xw .. 13) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinance or regulation, must be reviewed and approved by Mason County prior to construction. X BLD2013-00033 Please refer to the following pages for conditions of this permit. Page 3 of 4 14) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 15) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. X z 16) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit holder have prevented action from being taken. No more than one extension may be granted. X 17) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors, and flashing. Install metal connectors approved for contact with the new types of pressure treated material. X 18) Retaining walls needed to support a surcharge such as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X 19) By definition, propane tanks and heatpumps are structures,.which must meet setback conditions. Please check your"Approved Site Plan" to ensure these structures meet the setback conditions listed. X 20) Landings and stairs must meet the same setback conditions as any permitted structure-, and, must be shown on your site plan. Please check your "Approved Site Plan"to ensure these structures are shown and meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection. The owner or the agent on the owners behalf, represents that the information provided is accurate and grants employees of Mason County access to the abov de ribed property and structure for review and inspection. OWNER OR AGENT: l- DATE: . - BLD2013-00033 Please refer to the following pages for conditions of this permit. Page 4 of 4 G N CO,0SRETE' MECHANICAL MANUFACTURED HOME O ♦ Date By w Footings!Setbacks Gas Piping Ribbons M o Interior Date By interior-Date By Date By Extergr Date Z��'�3 By Exterior-Date INSULATION B Set_ Q r Point Load!Isolated Footings — Date By m BG I SLAB INSULATION Date By Data By FIRE DEPARTMENT Z Foundation Walls Floors Date By Date By Data _ By DECKS FRAMING Walls Date By Date 2 — = By Data By PROPANE TANKS PLUMBING Vault Date �y:__________ Date y OTHER Groundwork Attic .. Date By Date By Type�Oxy DRYWALL Da1e Z —/I—/� By D.W.V Type- Int.Brace Wall Date By Date By N Date — — By FINAL INSPECTION p CD Water Line Fin Separation y� Q Date By Date By Dal -3_ B m w Pass or Request Inspect. o s Ty of Insp. Fail Date Date Done By Comments o ro w o CD a 0 J04- 0 N O w (D 3 N lD ..A 0 R ' MASON COUNTY PERMIT NO. � L �� - �!�CJ BUILDING PERMIT APPLICATION 426 W. Cedar• P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269 On the web www.co.mason.wa.us APPLICANT INFORMATION CONTRACTOR INFORMATION Owner iV tti a- M I L-LE(` Company Name Mailing Address P 30 � 1 I Mailing Address City-4 E4-Ed I R State 1a)d Zip Code 9 S 5 2- City State Zip Code Phone S—SLf s Other Ph. Phone Other Ph. Lien/Title Holder -SA/"t E- Contractor Reg. # Exp. E mail address E Mail Address Drivers Lic.#M 1 LL '=Gi 4LI11,,c-D DOB Drivers Lic.# DOB SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic x Connect to Water System Name of Water System Well Water System Name of Water System PARCEL INFORMATION - 12 Digit Parcel No. I a 3 �4c�:) i 3 — 9/ o / Fire District Legal Description T(1 7 o if L� ya S c i a.1 V T R I o F S P ! 9 I Site Address(Please include street name, street number and city) I/S / N o L.,D 3L_4_P6i YO, t}W Y. 13 L L EkLR Directions to site E ROM 13 '=L rA t R- (::;c> Qc)RT i-1 n o�) Ttt-�_ c i-t7 t2 11(i Y 1, 3 ._-. I s! iu Will timber be cut and sold in parcel preparation? Yes o Is property within 200'of Saltwater Lake River/Creek Pond Wetland Seasonal Runoff Stream Slopes or Bluffs > 15% Is this permit submittal the result of a Stop Work Notice,Correction Notice or other enforcement action?Yes/6jj�_) TYPE OF JOB - New Adder Alt Repair Other PRIMARY RESIDENCE ®, SEASONAL ❑ Use of Building Describe Work 0212 /lo% fg El- BEDELOc>r\ No. of Bedrooms No. of Bathrooms Square Footage- 1 st Floor 2nd Floor 3rd Floor Basement Deck Covered Deck Other Sq. ft. Garage Attached Detached Carport Attached Detached MANUFACTURED HOME-INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner,owners legal representative,or the contractor.I further declare that I am entitled to receive this permit and to do the work as proposed in the application.I declare that I have obtained the permission from all the necessary parties.If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application,I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. PROOF OF CONTINUATION OF WORK IS BY INS OF A PROGRESS INSPECTION. X ti Daterzl,� 3 (�!5_wn_e_r_bowners Representative'/Contractor indicate which one FOR OFFICIAL USE BEYOND THIS POINT Accepted by: Date DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department Planning Department Environmental Health Department Public Works Department Fire Marshal FEES Buildinq Permit Fee Site Inspection Plan Review Fee EH Review Fee Plumbing & Base Fee Planninq Review Fee Mechanical & Base fee Other Wood/Gas/Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST Owner's Name: m Al I l er) Date: Reviewed By: Documents: Building Permit Application Completed Y Stormwater Checklist Planning Intake Checklist Completed, _Site plan includes:Allowable building area,roof overhangs,decks,etc. Fire Apparatus Access Road info required? Yes/No Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) \ - O Other: Specify: v' Mechanical/Plumb!. Application-WATER HEATER FUEL TYPE/LOCATION Engineering? Ye Snow load: Seismic: Stock Plan—approved snow load: Seismic: Manufactured Homes—4 FLOOR PLANS Foundation Type: ANSI/Manufacture method Engineered footing/foundation Basement Decks: Covered? Uncovered over 4 x 6 and over 30"? Construction plans required. Construction Plans:_3 COMPLETE SETS _Plans Legible _Recognized Scale _Elevation Views _Cross Section _Foundation Plan _Roof Framing Plan _Floor Plan-Use of rooms noted(all floors) _Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F.??—stairs?) _Deck Framing Plan,incl cov.porch framing Plan Details. ;�j nC Roof framingtruss details, lay-out may be needed (Hip and girder location shown) ` S ,�,C Wall Framing-Does bearing-wall height exceed 10'?(Engineering may be required) , to Floor framing: Floor joists(size&spacing):�� ,Floor beams: Window headers. Typical header: Garage header: Foundation:footing size,reinforcement a L,I '-+ Concrete Walls-Does Concrete Wall Height Exceed 8'?(Engineering may be required, see details) v Landings at all exits?Less than 30"above grade?Y/N v_Heated By Furnace-Location of Furnace Fuel type: Fireplace/Stove Information Shown-Fuel Type? Location(s): 7C Window Sizes Marked on Plans �1 Braced wall panels(shear walls)marked on plans or lateral engineering? '%!I 2-story garage? (Engineering may be required) I'story of two story DI —45%,D2—55% COMMENTS: ENGINEERING REQUIRED Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a result of the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless proven otherwise). Seismic Zone: ,Snow sf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be designed in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one or more of the following conditions occur: 1)Exterior braced wall line or BWP cantilevered or offset by more than 4' 2)Roof or floor is not laterally supported on all edges 2A)Portion of roof or floor extend more than 6 ft.beyond the braced wall line. 3)End of BWP extends more than 1 ft.over an opening more than 8 ft in width below. 4)Opening in a floor or roof exceed the lesser of 12 ft.or 50%of the least floor or roof dimension. 5)Portions of floor level are offset vertically 6)Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed.In accordance with accepted engineering practice. H:\permit tech building checklist.doc Revised 11-29-2007