Fire Alarm System Certification and Description - FIR Letters / Memos - 8/31/1995
- w FIRE ALARM SYSTEM CERTIFICATION AND DESCRIPTION ORIGINAL Complete Parts 1 and 3 through 9 after the system is installed, and the installation wiring has been checked. Complete Part 2 after the operational tests have been performed. PROTECTED SYSTEM SYSTEM SERVICE PROPERTY INSTALLER SUPPLIER ORGANIZATION Name St.Hugh Episcopal Church Alarm&Telecom,Inc. some same Address E.280 Wheelwright Street P.O.Box 2664 same same Allyn,Washington 98524 Silverdale,WA 98383 Representative Gloria Eakle,Senior Warden Dennis A.Herrmann same some Telephone (360) (360)698-5000 same some Location of As-Built Drawings-At the"Protected Property' Location of Owner's Manuals-At the"Protected Property". Location of Test Reports-Fire Marshall(Authority Having Jurisdiction),Alarm&Telecom,Inc. l. CERTIFICATION OF SYSTEM INSTALLATION: (Fill out after installation is complete and wiring checked for opens,shorts,ground faults,and improper branching,but prior to conducting operational acceptance tests.) This system installation was inspected by Dennis A. Herrmann, Vice President on 09/01/1995_and found to comply with the installation requirements of: X NFPA 72A,72B,72C,72D, 72E,72F Article 760 of NFPA 70,NationaiEiechicaiCode@ NFPA 72H X Manufacturer's Instructions Other(solmcify) Signed Date:September 1, 1995 Organization Alarm&Telecom Inc. 2. CERTIFICATION OF SYSTEM OPERATION: All operational features and functions of this system were tested by Dennis A. Herrmann, Vice President on 09/01/1995 and found to be operating in accordance with the requirements of: X NFPA 72A,72B, 72C,72D, 72E,72F Job Specifications X Manufacturer's Instructions Other ecify) Signed Date:September 1, 1995 Organization Alarm&Telecom,Inc Test Witness for the Authority Having Jurisdiction 3. TYPE(S) OF SYSTEM OR SERVICE: NFPA 72A-Local. If alarm is transmitted to location(s)off premises,list where received: Alarm&Telecom Inc. NFPA 72B-Auxiliary. Indicate type of connection: Local Energy Shunt Parallel Telephone Cellular Telephone Location and telephone number for receipt of signals Alarm&Telecom,Inc. (360)698-5000 XX NFPA 72C-Remote Station: Location and telephone number for receipt of signals Alarm Alarm&Telecom,Inc.-(360)698-5000 Supervisory NFPA 72D-Proprietary. If alarms are retransmitted to Public Fire Service Communications Center or Central Station,indicate location and telephone number of the organization receiving alarm Indicate how alarm is retransmitted NFPA 72F-Emergency Voice/Alarm Service: Quantity of voice/alarm channels Single Multiple(specify) Quantity of speakers installed Quantity of speaker zones Quantity of telephones or telephone jacks included in system - 4. ALARM INITIATING DEVICES AND CIRCUITS: Quantity and style(See NFPA 72A,Table 2-12.1)of initiating device circuits connected to system: Quantity FIVE(5) Style Types and quantities of alarm initiating devices installed: 7 Manual Stations xx Noncoded Coded Quantity 2 Smoke Detectors Ion Photo Quantity 0 Duct Detectors Ion Photo Quantity 2 Sprinkler Water Flow Switches Quantity Other(list) Quantity 5. ALARM INDICATING APPLIANCES AND CIRCUITS: Quantity of indicating appliance circuits connection to system TWO(2) Types and quantities of alarm indicating appliances installed: 1 Bells Size 10" Quantity 3 Horns Quantity Chimes Quantity Other(specify) Quantity 5 Visible Signals Type Quantity Indicate whether: XX combined with audible XX mounted separately 6. SUPERVISORY SIGNAL INITIATING DEVICES AND CIRCUITS: Quantity and style(see NFPA 72A,Table 2-12.1)of supervisory circuits: Quantity Style Types and quantities of supervisory and signal initiating devices installed: 4 Sprinkler Control Valve Quantity Engine Fire Pump: Building Temperature Quantity Fire Pump Power Quantity Site Water Temperature Quantity Fire Pump Running Quantity Site Water Supply Level Quantity Engine-Driven Generator: Electric-Driven Fire Pump: Selector in Auto.Position Quantity Selector in Auto.Position Quantity Control Panel Trouble Quantity Engine or Control Panel Trouble Quantity Transfer Switch Quantity Fire Pump Running Quantity Engine Running Quantity Other Supervisory Function(specify): Quantity 7. SIGNALLING LINE CIRCUITS: Quantity and style (See NFPA 72A,Table 2-13.1)) of signaling line circuits connected to system: Quantity:2 Style(s) B. SYSTEM POWER SUPPLIES: a. Primary(Main): Normal Voltage 120 VAC Amps 20 Overcurrent Protection: Type BREAKER Amps 20 Location b. Secondary(Standby): XX Storage Battery: Amp-Hr.Rating 14 Calculated capacity to operate system,in hours XX 24 60 Engine-driven generator dedicated to fire alarm system Location of fuel storage c. Emergency or Standby System used as backup to Primary Power Supply,instead of using a Secondary Power Supply: Emergency System described in NFPA 70,Article 700 Legally Required Standby System described in NFPA 70,Article 701 Optional Standby System described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701 9. SYSTEM DEVIATIONS FROM THE REFERENCED NFPA STANDARDS: XX None As per attached sheet(describe fully): ALARM & TELECOM, INC. P.O. BOX 2664 Silverdale, Washington 98383 (360) 698-5000 O Monitoring/Service Agreement This agreement is entered into this 28th day of August, 1995, by and between Alarm & Telecom, Inc., hereinafter referred to as "A&TI" and "Company", and St. Hughs Episcopal Church, located at E. 280 Wheelwright Street, Allyn, Washington 98524, hereinafter referred as "Subscriber". 1. SERVICES PROVIDED: [X] Monitoring [X] Repair Service [X] Annual Maintenance 1.1 MONITORING SERVICES: Signals of the alarm systems owned by the Subscriber at the premises, as set forth in enclosure (1), and received at the UL Central Station Monitoring Facility, as per the attached Schedule of Protection, shall be monitored by COMPANY. If, in the opinion of COMPANY, use by the Subscriber adversely affects the use of the receiving equipment, Notice of Equipment Fault (NEF) will immediately be issued and will necessitate a corrective repair made within fifteen (15) days following such notice to Subscriber. Subscriber acknowledges that COMPANY'S service obligation with respect to monitoring relates solely to the repair and operation of the monitoring receiving equipment. COMPANY is no way obligated to maintain, repair, service, replace, operate, or assure the operation of the property, system, or any devices or device of the Subscriber, unless provided in Paragraph 1.2 below. The Subscriber agrees to furnish the Contractor with a list of names to be contacted in the event of an alarm and names of the individuals that will have keys to the buildings for normal system maintenance. 1.2 REPAIR SERVICE: Subscriber authorizes COMPANY to provide repair service for the aforesaid system(s) in accordance with the following selected by Subscriber. 1.2.1 TIME AND MATERIAL SERVICE: All repairs shall be at Subscribers expense, and all repairs shall be performed between the hours of 8:OOam and 5:OOpm on Monday through Friday, excluding national holidays. Repairs that COMPANY is obligated to perform pursuant to this section shall generally be performed on the next business day following request for service be Subscriber unless otherwise provided. Subscriber agrees to pay for all materials, parts and labor used at COMPANY'S then prevailing rates, with a minimum one (1) hour labor charge for each visit. payment of charges for service shall be paid within ten (10) days of receipt of COMPANY'S invoice. 1.2.2 WARRANTY: All new installation labor is warranteed for one (1) year. Newly installed equipment is normally warranteed for a period of one (1) year by the manufacturer. A&TI warranties new equipment installed for the period of the manufacturer's warranty or one (1) year which ever is greatest. Repairs required during the warranteed period, necessitated by ordinary tear, wear or failure before expiration of warranty, shall be at COMPANY'S expense. All other repairs shall be at Subscribers's Page 1 St Hugh Episcopal Church Monitoring/Service g Agreement (continued) August 28, 1995 expense pursuant to the terms and conditions as set forth in Paragraph 1 .2.1 as hereinabove set forth. Repairs which may be required on the part of COMPANY shall be performed as soon as reasonably possible after receipt of notice by COMPANY by Subscriber. 1.2.3 ANNUAL MAINTENANCE TESTING: Mason County directs that all commercial fire alarm systems be both UL Central Station Monitored and tested on an annual basis. 2. PAYMENT AND TERMS: Subscriber agrees to pay to COMPANY, its agents or assigns: 2.1 For monitoring, the sum of Twenty-eight Dollars ($28.00) per month, payable monthly in advance, on the 1 st day of the month commencing with the month following completion of the initial connection for a period of one (1) year. In addition, Subscriber shall pay the pro-rata share of the service period for the month in which the connection, installation, or inspection is completed. 2.2 For service, the sum of Thirty-five ($35.00) Dollars per service call, which includes the first one half hour of labor, and Thirty-five ($35.00) Dollars per hour, payable monthly, on the first day of the month after the work performed. 2.3 For annual maintenance testing of the fire alarm system, the sum of One Hundred Five Dollars ($105.00) per annual test, payable monthly, on the first day of the month after the work performed. 2.4 This Agreement can be renewed for one (1) year periods by notifying the Company, in writing or orally. Subscribers intention to extend this Agreement IS ASSUMED if ''Notice To Extend'' is NOT received by thirty (30) days prior to the expiration of the original term or renewal term thereof. 3. RESPONSE TO ALARMS: 3.1 CENTRAL ALARM OFFICE: If monitoring service is provided, COMPANY shall, without warrant, make every reasonable effort to do the following: 3.1.1 Upon receipt of a burglar alarm signal, transmit the alarm to CENCOM headquarters and notify the Subscriber or his designated representative by calling the telephone number supplied to COMPANY in writing by Subscriber. 3.1 .2 Upon receipt of a burglar alarm signal, transmit the alarm to the CENCOM headquarters as per above. 3.1.3 Upon receipt of a water flow, sprinkler, manual, smoke or automatic fire alarm signal, transmit the alarm to CENCOM headquarters. Page 2 St Hugh Episcopal Church Monitoring/Service Agreement (continued) August 28, 1995 3.1.4 Upon receipt of a supervisory signal, notify Subscriber of his designated representative by calling the telephone number supplied to COMPANY in writing by Subscriber. 4. TELEPHONE LINES: Subscriber shall pay all charges made by any telephone company or other utility for installation, leasing and service charges of telephone lines connecting Subscribers's protected premises to COMPANY'S Central Station when a digital communicator or direct line is installed or when the signals are transmitted to Emergency Services headquarters. Subscriber acknowledges that if COMPANY utilizes a digital communicator for the purpose of transmitting alarm signals from Subscriber's premises to COMPANY'S Central Station, and in the event Subscriber's telephone service is out of order, disconnected, placed on vacation or otherwise interrupted, signals from Subscriber's alarm system will not be received in COMPANY'S Central Station during any such interruption in telephone service, and the interruption will not be known to COMPANY. Subscriber further agrees to pay all charges made by any telephone company or utility for installation, leasing and service charges of telephone services when Subscriber's regular telephone service is used. Subscriber acknowledges that the signals are transmitted over telephone utility lines, which are wholly beyond the control and jurisdiction of COMPANY and are maintained and serviced by the applicable telephone utility. 5. FALSE ALARMS: In the event an excessive number of false alarms are caused by Subscriber's carelessness, malicious action or accidental use of the alarms system or in the event Subscriber in any manner misuses or abuses the system, COMPANY may in its sole discretion deem this to be a material breach of contract on the part of the Subscriber and , at its option, in addition to all other legal remedies set forth below, be excused from further performance upon the giving of the (10) days written notice to Subscriber. COMPANY 'S excuse from performance shall not affect its right to recover damages from Subscriber. In the event a fine, penalty or fee is assessed against COMPANY by any governmental or municipal agency as a result of any alarm originating from Subscriber's premises, where Subscriber intentionally, accidentally or negligently has activated the alarm signal, and no alarm condition exists, or if COMPANY makes any service call caused by negligence of Subscriber, Subscriber shall pay to COMPANY a charge to be set by COMPANY for each such call. Subscriber represents he fully understands that the equipment, because of its sensitive nature, is subject to influence of external events which are not within the control of COMPANY and which may cause the alarm to activate. Any or all such alarms shall not excuse any of the obligations of Subscriber as set forth in this Agreement. 6. CANCELLATION: COMPANY assumes no liability for interruption of monitoring and/or service due to strikes, riots, floods, storms, earthquakes, fires, power failures, acts of Subscriber, interruption or unavailability of telephone service acts of God or other cause P Y p , beyond the control of COMPANY and will not be required to supply monitoring and/or repair service to Subscriber while interruption of service due to any such cause may continue. This Agreement may be suspended or canceled, without notice at the option of COMPANY, if COMPANY'S or Subscribers's premises or equipment are destroyed by fire or other catastrophe, or so substantially damaged that it is impractical to continue service or in the Page 3 St Hugh Episcopal Church Monitoring/Service Agreement (continued) August 28, 1995 event COMPANY is unable to render service as a result of any action by any government authority. Upon termination of this Agreement for any reason, Subscriber authorizes COMPANY to enter Subscribers's premises and disconnect Subscriber's signaling equipment from COMPANY'S monitoring system. 7. SUBSCRIBER'S DUTIES: The Subscriber shall carefully and properly test and set the alarm system immediately prior to the securing of the premises during the term of this Agreement. If any defect in operation of the system develops, or in the event of a power failure or other interruption at Subscriber's premises, Subscriber shall notify COMPANY immediately. If space protection (i.e., Ultra-Sonic, Microwave, Infra-Red, etc.) is a part of said system, Subscriber shall walk test the system each day in the manner recommended by COMPANY. When any device or protection is used, including but not limited to space protection, which is affected by turbulence of air, occupied airspace change, or disturbing conditions, Subscriber shall turn off or remove all things, animate or inanimate, including but not limited to forced air heaters, air conditioners, horns, bells, animals, and any other sources of air turbulence or movement, which may interfere with the effectiveness of the system during closed periods while the alarm system is on. Subscriber shall notify COMPANY of any remodeling or other changes to the protected premises that may affect the operation of the system. Subscriber agrees to furnish to COMPANY a written list of the names, titles, addresses, phone numbers and signatures of all persons authorized to enter or remain on the premises and/or be notified in the event of an alarm. All changes, revisions and modification to the above shall be supplied to COMPANY in writing. 8. DEFAULT BY SUBSCRIBER: If Subscriber fails to pay any amount herein provided within ten (10) days after COMPANY shall have request in writing performance thereof, of if any proceeding in bankruptcy, receivership or insolvency shall be commenced by or against Subscriber or his property, or if Subscriber makes any assignment for the benefit of creditors, COMPANY shall have the right but shall not be obligated to exercise any one or more of the following remedies: (a) Recover the existing amounts due from Subscriber and continue to service the system, In which case COMPANY shall be entitled to recover, in addition, the monthly amounts due under the contract for said services; or (b) Disconnect Subscriber's system from COMPANY'S monitoring network upon five (5) days written notice and recover from Subscriber all sums COMPANY may be entitled to under the law. 9. COMPANY IS NOT AN INSURER; LIMITATION OF LIABILITY: 9.1 It is understood and agreed: That COMPANY is not an insurer; that insurance, if any, shall be obtained by Subscriber; that the payments provided for herein are based solely on the value of the service as set forth herein and are unrelated to the value of the Subscriber's property or the property of others located on Subscriber's premises; that COMPANY makes no guaranty or warranty, including any implied warranty of merchantability or fitness that the equipment or services supplied will avert or prevent occurrences of the consequences therefrom which the system or service is designed to detect or avert. Subscribers acknowledges that it is impractical and extremely difficult to fix the actual damages, if any, which may proximately result from COMPANY'S negligence, or Page 4 St Hugh Episcopal Church Monitoring/Service Agreement (continued) August 28, 1995 a failure to perform any of the obligations herein, including, but not limited to installation, service, or monitoring or the failure of the system to properly operate with resulting loss to Subscriber because of, among other things: 9.1 .1 The uncertain amount or value of Subscriber's property of the property of others kept on the premises which may be lost, stolen, destroyed, damaged or otherwise affected by occurrences which the system or service is designed to detect or avert; 9.1.2 The uncertainty of the response time of any police or fire department, paramedic unit or others, should they be dispatched as s result of a signal being received or an audible device sounding; 9.1 .3 The inability to ascertain what portion, if any, of any loss of property, personal injury or death would be proximately caused by COMPANY'S failure to perform or by its equipment to operate; 9.1.4 The nature of the service to be performed by COMPANY. Subscriber understands and agrees that if COMPANY should be found liable for loss or damage due from COMPANY'S negligence, or a failure of COMPANY to perform any of the obligations herein, including but not limited to installation, monitoring or service, or the failure of the services or equipment in any respect whatsoever, COMPANY'S liability shall be limited to a sum equal to the total of six (6) monthly payments or Two Hundred and Fifty Dollars ($250.00), whichever is the lesser, and this liability shall be exclusive; and that the provi- sions of the Section shall apply if loss or damage, irrespective of cause or origin, results directly or indirectly to persons or property, from performance or non-performance of the obligations imposed by this Contract, or from negligence, active or otherwise of COMPANY, its agents, servants, assigns or employees. 9.2 If Subscriber wishes COMPANY to assume a greater limited liability in lieu of the amount as hereinabove set forth, Subscriber may obtain from COMPANY a higher limitation of liability by paying an additional periodic service charge to COMPANY. If Subscriber elects to exercise this option, a rider shall be attacked to this Agreement setting forth the terms, conditions and amount of the limited liability and the additional charge. Such a rider and additional obligation shall in no way be interpreted to hold company as an insurer. 10. THIRD PARTY INDEMNIFICATION: When Subscriber in the ordinary course of business has the property of others in his custody, or the alarm system extends to protect property of others, Subscribers agrees to and shall indemnify, defend and hold harmless COMPANY, its employees and agents for and against all claims brought by parties other than the parties to this Agreement. This provision shall apply to all claims regardless of cause, including COMPANY'S performance or failure to perform and including defects in products, design, installation, operation or non-operation of system, whether based upon active or passive negligence, contribution, indemnification, warranty, or strict or product Page 5 St Hugh Episcopal Church Monitoring/Service Agreement (continued) August 28, 1995 liability on the part of COMPANY, its employees or agents, but this provision shall not apply to claims for loss or damage solely and directly caused by an employee of COMPANY while on Subscriber's premises. 11. Subrogation: So far as it is permitted by Subscriber's property insurance coverage, Subscriber hereby releases, discharges and agrees to hold COMPANY harmless form any and all claims, liabilities, damages, losses or expenses, arising from or caused by hazard covered by insurance in or on the Subscribers's premise whether said claims are made by Subscriber, his agents, or insurance company or other parties claiming under or through Subscriber. Subscriber agrees to indemnify COMPANY against, and defend and hold COMPANY harmless from any action for subrogation which may be brought against COMPANY by any insurer or insurance company or its agents or assigns including the payment of all damages, expenses, costs and attorney's fees. Subscriber shall notify his insurance carrier of the terms of this provision. 12. LIMITATION ON ACTIONS; WAIVER OF TRIAL JURY: Both parties hereby agree that no suit or action that relates in any way to this Agreement (whether based upon contract, negligence or otherwise) shall be brought against the other more than one (1 ) year after the accrual of the cause of action therefore. In addition, both parties hereby waive any rights to a jury trial in any judicial action brought by either party which relates in any way to this agreement (whether based upon contract, negligence or otherwise). 13. ASSIGNEES/SUBCONTRACTORS OF COMPANY: COMPANY shall have the right to assign this Agreement to any other person, firm or corporation without notice to Subscriber, and shall have the further right to subcontract any installation or monitoring or services which it may perform. Subscriber acknowledges that this Agreement and particularly Paragraphs 10 through 13 relating to COMPANY'S maximum liability and third party indemnification inure to the benefit of and are applicable to any assignees and/or subcontractors of COMPANY and that they bind Subscriber with respect to said assignees and/or subcontractors of COMPANY with the same force and effect as they bind Subscriber to COMPANY. 14. PURCHASE ORDERS: It is understood and agreed by and between the parties hereto, that if there is any conflict between this Contract and Subscriber's purchase order, or any other document, this Agreement will govern, whether such purchase order or other document is prior or subsequent to this Agreement. 15. ATTORNEY'S FEES: In the event is shall become necessary for COMPANY to institute legal proceeding to collect the cost of any charges as set forth herein, then and in such proceeding, Subscriber shall pay to COMPANY reasonable attorney's fees and all court costs. Page 6 St Hugh Episcopal Church Monitoring/Service Agreement (continued) August 28, 1995 16. INVALID PROVISIONS: In the event any of the terms or provisions of this Agreement shall be declared to be invalid or inoperative, all of the remaining terms and provisions shall remain in full force and effect. 17. ENTIRE INTEGRATION AGREEMENT; MODIFICATION; ALTERATIONS; WAIVER: This writing is intended by the parties as a final expression of their agreement and as a complete and exclusive statement of the terms thereof. This Agreement supersedes all prior representations, understandings or agreements of the parties, and the parties rely only upon the contents of this agreement in executing it. This Agreement can only be modified by a writing signed by the parties or their duly authorized agent. No waiver of breach of any terms or condition of this Agreement shall be construed to be a waiver of any succeeding breach. 18. NOTICES: All notices to be given hereunder shall be in writing and may be served, either personally or my mail, postage prepaid to the addresses set forth in the Agreement or to any other address provided by one to the other from time to time in writing. SUBSCRIBER: St Hugh Episcopal /Ci�hurch /J Agreed: nloria Eakle, Senior Warden Date: August 1995 COMPANY: Approved: David E. Oliver, President Date: August 28, 1995 CC' Senior Warden Mason County Fire Marshall Page 7 GROUP 1 20645�5902 GENTEX NewLower Opera tin Cutrent t SERIES 4" Electronic Horn HG or SHG Series r Applications 4" low frequency electronic horn and horn/strobe E' that meets code requirements for supervised fire • alarm systems• r r; The HG/SHG series are quality electronic signaling I devices that offer you both dependable evacuation =' signals and visual alarms or a comh)ination of both by simple terminal wiring. The SHG series can also be StiG wired to have independent operation of both horn and strobes. (See wiring diagrams). This can be simply Approvals done by removing two jumper plugs located on cirduit board. (See installation manual for details.) HG i The HG/SHG series are easily field changeable from a steady low frequency alarm signal to a puls ng low frequency alarm signal by simply removing a + � jumper plug. Changing from steady tone to pulsing « ; MEME.En tone does not prevent reverting back to original torje at a later date. All units are shipped from the facto y in the steady alarm mode. The HG/SHG series are designed to be used to� • Americans with Disabilities Act (ADA) both new construction or retrofit projects by easily . BFP mounting to 4"electrical boxes or 2 gang old work . BSA/MFA boxes (see back for details). All HG/SHG devices are UL 464 listed for use with • CSFM #7135-569:11 fire protective systems and are warranted for 2 years • NFPA 72G from the date of purchase. • UL 464 ti l Standard Features Available Models t • Low frequency/penetrating output. Modal Operating Walt Gelling Light Rated Peak Number Voltage Mount ; cunt Effective urrant dB • Low current consumption 17mA. (HG124) t Intensity In Draw c Wide voltage range. Candela @24V 10 ft. • Screw terminals, separate in/out wiring option for HG124 10-30 NA 17mA too both horn and strobe. gHG12L-W W-1G i 1.7 cd 50mA" 90" • Steady or pulsing tone. SHCj12L-C 10. 16 1.7 cd 50mA•• s0•• • 1 extured finish high Impact plastic faceplate. SHG24L-W 21 -$0 17.8 ed' 52mA 95 • Wide variety of mounting options for new construe- 5HG24L-C, 21 -30 17.8 od' 52mA 95 lion and retrofit applications. 1,;HG24H-W 21 -30 100 ad MmA as • Supplied with beQllty plugs to accommodate a � SH02414•C 1 21 -30 100 cd 105mA 95 variety of Installations. •9.7 cd Ct o`C }},, • Flush or semi-flush mounting without the need of il -At 12vbc trim plate. NOTE: High candsla strobes(H option)have a 200mA peak • 1 P 8 strr+P bhhbrt t'�'z�R), ! np?��tinr7 current. • UL 464 listed for fire, ao ., tr lec ivo rorvi,n RUE OvEFoj FEATURES JUN 131995 • Extremely Low Operating Current • High dB Output GENERAL SERVICE • ADA Horn-Strobe Versions • Very Low Electrical Noise (n • Standard 4" Square Mounting W • UL Listed - 464 File #E4300 ;: yr' m • CSFM - Pending 0 • FM - Pending Ix • Screw Terminals ��ss G; • Attractive Vandal Resistant Design z irl ADA FLUSH MOUNTING 0 DESCRIPTION: The 5340 Series Horn combines state of the art UI electronics with the rugged durability of a metal z housing. This series eliminates the effects of ,i. ' ICE inrush and RFI contact noise associated with electromechanical horns. The design of the e:,,ttf i;j •t ; Z horn and Dorn/strobe allows for either surface,flush, or ceiling mounting on a standard 4-inch 0 V square backbox which eliminates the need for z a special backbox and mounting plate. 0 Accessories are available for concealed conduit �, h mounting. i. r }. U The 24VDC horn is twice as loud as UL J requirements for Fire Alarm use, while using CEILING MOUNTING W only 20 ma. of current. Current draw is the M same whether connected to filtered or unfiltered W power supplies. Screw terminals are provided [r for both the horn and the strobe. The strobe is ' W configured to operate independently from the Ul horn. (] The units with an integral ADA or standard fi�1 strobe have a Xenon flashtube with solid state In circuitry for maximum reliably and efficiency. The Lexan lens for the strobe is translucent white with the word FIRE in red letters. FLUSH MOUNTING FIRE ALARM SIGNALING DEVICES • 11534011 SERIES ORDERING INFORMATION HORN 12-30 VDC CONSISTING OF 24 VDC RATINGS 12 VOC RATINGS PART NO. MOUNTING BASIC BASIC VOLT dR AT VOLT d8 AT HORN GRILL RANGE 101• AMPS RANGE 101• AMPS 5343L-0-14-24-DC 5005L FLUSH 21-30 92-95 20 ma 12 85 10 ma 5344L-0-14-24-DC 5340 5006E SURFACE 21-30 92-95 20 ma 12 85 10 me 5345L-0-4-24-DC 5008E CEILING 21-30 92-95 r2O mp 12 85 10 ma 110"N \ STROBES PART NO. MOUNTING VOLTAGE OPERATING CURRENT VOC dU AT 10'• STROBE ADA _ HORN STnO6E INTENSITY 534eL-0-14-24-ne FLUSH 21-30 92-95 20 mw 75 ma 120 cd YES 5347L-11-14-24-DC SIIhFACE 2/-30 92-95 20 mq 75 mw I 120 cd VES 534eL-U-4-24-nC CEILING 21-30 92-95 20 mn 75 mw 120 cd NO 534eL-U-14-12-nC FI.IMtI 12 05 10 ma 150 MR 120 cd YES 5347L-U-14-12-nC SURFACE 12 05 1O mq 150 mw 120 ed YES 534e1--U-4-12-OC CEILING 12 e5 10 mot 150 mq 4.5 cd NO 534eL-0-14-24-DC FLUSH 21-30 92-95 20 mq 39 mw 4.5 cd NO 5347L-0-14-24-DC SURFACE 21-30 92-95 20 mq 38 mn 4.5 cd NO 534eL-O-4-24-OC CEILING 21-30 92-95 20 mq 39 mw 4.5 cd NO 5340L-O-14-12-nc FLUSH 12 05 10 mw 75 mw 4.5 cd NO 5347L-0-14-12-UC 911RFACE 12 95 10 mA 75 mn 4.5 cd NO 5340L-0-4-12-UC CEILING 12 e5 10 mq 75 mw 4.5 cd NO " Typical, measured at 10' Environmental ratings 0-49 C (32-120 F) 85% humidity I 11L nFVFnwFnFNT ROOM nAT1NOR � ACCESSOhIES 12 Vnr 75 dR PAnT# DEScnIPTION 71 Vnr a9 do 3017-14 w000n sunFACF nox 24 vOr ae dR 3019-14 CONCEALED CONDUIT PLATE When strobe and electronic signal are con- When strobe and electronic signal are connected nected to the seine signal circuit. to separate signal circuits. - — o 0 From Control Panel or _ W From Control Previous N Device From _ r - Panel or w Control ' — — 0 Z ® A.- To Next —m,-m Panel or> AA Device or Previous _ Previous ® r I+ ® Device > _ 5. Device o To Next r— To Next ° � - —------- Device or - Device or -- O.L.---------- - ► E.O.L. ---- These Inslnrcllom do nol Purpnrl In cover atl tl.n details Or vAdatlons In the equlpmenl described,nor do"y provlde for every pnstbla con"riAnnry In be me InsIalIallon.operation and mnlnlennnce.Aft spncflicnl1nna RnhirbM In rhangn wllhnrd nnlvv.. t In rrnnMlOn wkh -- --— ELEC"I`E40N-MEC HANICAL. DC F-IClms - 6220 SLRIES FEATURES r' 1 • CONTACTLESS ELECTRON-MECHANICAL DESIGN • ENERGY EFFICIENT • LOW OPERATING CURRENT • PENETRATING MECHANICAL, SOUND F, ADA HORN-STROBE VERSIONS W� m NO CONTACT GENERATED INTERFERENCE f M • STANDARD 4" SQUARE MOUNTING • UL LISTED - 464 FILE #E4300 • CSFM, FM - PENDING ~ • PATENT PENDING z • SCREW TERMINALS Ix• IBEW/USA CRAFTED O : ' MAUk IN USA \ DESCRIPTION = ADA FLUSH MOUNTING The 6220 Series of Electron-Mechanical Horns combine state of the art electronics with the rugged Z proven durability of an electromechanical horn. a The combination of electronics and mechanics provides all of the penetrating sound power of a Z electromechanical horn while eliminating problems associated with contacts. This series eliminates "j , , a r•••••- the effects of inrush and RFI noise associated with 0 contact operated electromechanical devices.The z design also eliminates the possibility of building ;,• � dust and dirt contaminating the contacts. The Q F• design of the horn and horn/strobe allows for either surface, flush, or ceiling mounting on a V standard 4-inch square backbox which eliminates W the need for a special backbox and mounting I plate. Accessories are available for concealed conduit and weatherproof mounting. Z P 9• CEILING MOUNTING (] The 12VDC&24VDC horns are over twice as loud Ix as UL requirements for Fire Alarm use. Because of the energy efficient design, the 24V units draw (� only 38 ma. and the 12V units draw only 76 ma. W Current draw is the same whether connected --j to filtered or unfiltered power supplies. Screw _ W terminals are provided for the horn. The strobe (n is configured to operate independently from Uj .�. the horn. •;' ' � The units with an integral ADA or standard strobe W have a Xenon flashtube with solid state circuitry (n for maximum reliability and efficiency. The Lexan lens for the strobe is translucent white with the C) word FIRE in red letters. lu ICU (D Although this design does not contain any contacts, it is not designed to be used in hazardous locations. Please refer to the 4120 and 4130 series of explosion- ADA SURFACE MOUNTING proof devices. 3 ELECTRON-MECHANICAL HORN - 6220 SERIES ORDERING INFORMATION HORN CONSISTING 24 VOID HORN 12 VOID HORN W PART N0. OF m ( ) n 12 OR 24 MOUNTING W BASIC BASIC VOLT dB AT VOLT dB AT O HORN GRILL RANGE 10,• AMPS RANGE 10,• AMPS [� 6223L-0-14-( )-DC 5003E FLUSH 21-30 96 38 ma 12 96 76 ma 6224L-0-14-( )-DC 6220 5004L SURFACE 21-30 96 38 ma 12 96 76 ma 6225L-0-4-( )-DC 5005L CEILING 21-30 96 38 ma 12 96 76 ma Z M HORN / STROBES Z VOLTAGE dB AT OPERATING PART NO. MOUNTING 1 * CURRENT STROBE INTENSITY VDC 10 ADA � U) HORN STROBE Z 6226L-U-14-24-DC FLUSH 21-30 96 38 ma 75 ma 120 cd YES 6227L-U-14-24-DC SURFACE 21-30 96 38 ma 75 ma 120 cd YES 0 6228L-U-4-24-DC CEILING 21-30 96 38 ma 75 ma 120 cd NO 6266L-U-14-12-DC FLUSH 12 96 76 ma 150 ma 120 cd YES A 6227L-U-14-12-DC SURFACE 12 96 76 ma 150 ma 120 cd YES Q 62281--U-442-DC CEILING 12 96 76 ma 150 ma 120 cd NO U z 6226L-0-14-24-DC FLUSH 21-30 96 38 ma 38 ma 4.5 cd NO Q 6227L-0-14-24-DC SURFACE 21-30 96 38 ma 38 ma 4.5 cd NO 6228L-0-4-24-DC CEILING 21-30 96 38 ttla 38 ma 4.5 cd NO (� 6226L-0-14-12-DC FLUSH 12 96 76 ma 75 ma 4.5 cd NO c6227L-0-14-12-DC SURFACE 12 96 76 ma 75 ma 4.5 cd NO 6228L-0-4-12-DC CEILING 12 96 76 ma 75 ma 4.5 cd NO 'Ex0 FRO " Typical, measured at 10' PREVIOUS ° +S Horn Circuit ° + TO UL REVER13ERENT ROOM ((i� DEVICE ° — ° — DNEVVIICE dB. RATINGS wIlse terminals for connection.Break wire runs to 12 VOID 85 dB I J + provide Electrical Supervision W _ Bed 24 VDC 85 dB r� PREVIOUS Cat.No.5511 (n or 5512 NEXT Environmental ratings (-35 to 66)C W _ Black Strobe Circuit DEVICE (-31 to 150)F, 98%humidity®40C/(104)F- rw Break wire runs to provide Electrkal Supervision Ex ACCESSORIES W U41ktcnnct1t, an -1 connector on strobe l Hom terminals PART # DESCRIPTION 0 + 301 --14 Weatherproof Box 1/2" Pipe ad AO, FROM ° Cat.No. ° + 3015-14 Weatherproof Box 3/4" Plpe `UPREVIOUS HORN5511 or BORN sm"r TO DEVICE5512 — EXT 3017-14 Indoor Surface Box Ej N ad` 3018-14 Semi-Flusll Plate Strobe b Signal on Same leccuNs 3019-14 Concealed Conduit Plate Break wire runs to provide Electrical Supervision ^� Theca InMrudlons do not purport to cover AA the delalts or vad kk nttons In the errOpment dnscrlbed,nor do It"prov for Avery possible conlinArrcy to be me in connecllon with Inslaltntlon,operation end mainlennnce.All specifications subject to change wittrord not". g HSPS SERIES HARRINGTONNon-Coded Manual Pull Stations Harrington Signal, Inc. 2519 4th Avenue, P.O. Box 590, Moline, Illinois 61265-0590 Phone: (309) 762-0731, Fax: (309) 762-8215 FEATURES * UL and CSFM Listed * Durable Die Cast Housing * 14 GA Plated Steel Back Plate * Corrosion Inhibit Surfaces * Terminal Block or Pigtail Connection * Single Gang Mounting * Surface (use of HSPS-BB) or Semi-flush Wall Mounting ' * 10 Amp Snap Action Switch * Single or Double Action ! * "T" Pull Handle or Key Operated Institutional Models * Red Enamel Finish (Standard) or Special Colors Available * Allen Wrench or Key Access 1 DESCRIPTION The Harrington model number HSPS series, non- coded manual pull stations provide the most reliable manually activated input signal for early warning signaling on supervised or non-supervised alarm � systems. When the die cast housing is opened, the "T" pull The HSPS stations are constructed of a die cast hous- lever may be reset to the normal operating position. ing which is connected to a 14 Ga plated steel back plate at the lower bottom corners. The HSPS series stations can be tested without the need to pull the "T" pull lever by using the alien The "T" pull lever, mounted on the die cast hous- wrench or key(depending on the model being used) ing, is constructed of die cast steel and is painted to opening the die cast housing. Opening the die white with raised lettering painted red that reads cast housing allows the plunger on the contact "PULL DOWN." When the "T" pull lever is activated arrangement to be activated, thus sending a signal (Pulled), it allows the plunger on the contact to the control panel. arrangement to be activated. The HSPS series station can be used with or without The HSPS series stations come standard with an a break glass rod positioned in front of the "T" pull alien wrench for locking, resetting and testing. With lever. The glass rod is not needed to hold the "T" the "KL" option, a key is used to lock, reset or test pull lever in its normal operating position. the station. The HSPS series stations have an optional Dual When the"T" pull lever has been pulled, it remains Action feature. The Dual Action option is a metal protruding out from the I-ISPS series station at a 90 cover that lies over the "T" pull lever. The Dual degree angle until the die cast housing is opened by Action cover is painted red with the words "LIFT& either the alien wrench or key(depending on the PULL" silk screened in white. To activate the HSPS model being used). PRINTED IN USA REV-A 4 series dual action station, the Dual Action cover SPECIAL APPLICATIONS needs to be lifted and then the "T" pull lever can be pulled.The Dual Action cover has a brass knob The HSPS series stations can be used In applications located at the bottom center which is used to lift it Where a weather proof enclosure is needed. Most HSPS series stations can be used in weather proof up. applications by using the weather proof back box, the "WP" option. Check with the factory'forapplic- able APPLICATIONS models that UL will allow to be used in weather The HSPS series pull stations have a wide variety of proof applications. features which makes it ideal for uses in office build- The HSPS series stations can also be used in Ings, apartment complexes, schools, correctional Hazardous atmospheres (Explosion proof) by adding facilities, nursing homes, hospitals and many more the "EXP" option to the HSPS series station. See the applications. Explosion Proof HSPS series manual pull station data sheet for more details. SPECIFICATIONS ELECTRICAL OPTIONS i.e., HSPS-(` )-( )-(etc.) Switch 10 Amp @ 120V AC Gold Contact 1 Amp @ 120V AC -1P SPST with Pigtail Connection Key Switch .5 Amp @ 30V DC -1T SPST with Terminal Block Connection Phone Jack .1 Amp @ 24V DC -2T DPST with Terminal Block Connection -6T DPDT with Terminal Block Connection DIMENSIONS -KL Key Lock/Reset/Test(Cat 15 is standard key size) HSPS-IT Width: 3.2 inches -KO Key Operated(Institutional Manual Station) HSPS-IT Length: 4.75 inches DA Dual Action Adapter HSPS-1T Depth: .875 inches -DAH Dual Action Adapter, Break Glass Type W/Hammer HSPS-IT Weight: 15.5 oz. -LPH I Dual Action Adapter for Halon Systems HSPS-DA Width: 3.325 inches -PJ Phone Jack for Firemen Telephone Systems HSPS-DA Length: 4.75 inches -LED Light Emitting Diode(Red,Green or Yellow) HSPS-DA Depth: 1.5 inches GCS SPST Gold Contact, 1 Amp @ 120V AC -GCD _ DPDT Gold Contact, 1 Amp @ 120V AC HSPS-DA Weight: 1 lb. 4 oz. .,... ,. _ .. : PS Presignal Key Switch, .5 Amp 30V D( HSPS-DAH Width: 3.325 inches -WP Weather Proof Back Box,UL approved w/HSPS HSPS-DAH Length: 4.75 inches series Stations HSPS-DAH Depth: 1.625 inches -BB Surface Back Box for Indoors Use HSPS-DAH Weight: 1 lb. 9 oz. Mounting Single Gang Surface w/HSPS-BB i4rfi ., p ' ' Until now,choosing a smoke detector meant deciding which features were essential to your application,and which features you could do without.After all,no smoke e I detector does it all,right?Wrong! Introducing the 100 Series Dkeet Win Smoke Detector from System Sensor,small in size 0 ' but large in features. Which features? Glad you asked: h: 4 I I i 2112/24T Photoclectronic with I henual Option Low profile? 1.66",the lowest in the industry. ' I Multiple wiring configurations?2-wire and 4-wire, 12/24 vl)C nwdels available. Electronic heat option? Models with 135° fi,\ckl heat available. Visible maintenance indication? Yes. Plug-in terminal block? Of course. Same look for Ion and Photo models? Naturally. Built-in test switch? You bet. In addition,the 100 Series includes a built-in MOD40OR sensitivity test port and a removable insect-resistant screen for easy cleaning or replacement.Top it off with a 3-year warranty and you can see why this ,dt smoke detector is the perfect choice for all TA Irm your applications,including commercial an residential.Of course,all 100 Series detectors feature proven System Sensor technology, so performance and reliability are a given. Need more information?Call your System Sensor distributor,or contact System FL Sensor,toll-free,at 1-800-SENSOR2. Ina. The New 100 Series Smoke Detector OR / I from System Sensor .'ss6 I I , The choice is obvious. 'ormat See page 60 for more information. PIIOTOELECTRIC SMOKE DETECTOR ��� N A R R I N G T N MODEL #SLK-24F 0 Harrington Signal Co. 2519 4th Avenue, P.O. Box 590, Moline, Illinois 61265-0590 Phone: (309) 762-0731, Fax: 309-762-8215 ;, y'r Applications A ' The SLK-24F can be used in all areas where Photoelectric Smoke Detectors are required. It is best suited for smoldering or flaming fires. 1 HS or YBA-M Style bases may be used with the SLK-24F. Current compatible devices are SLK- ' � 24FH, SIH-24F, or the HF-24 Flame Detector " y=, '`�' Operation The unit is comprised of an LED light source and ' silicon photo diode receiving element. In a normal standby condition, the receiving element receives no light from the pulsing light source. In the event of fire, smoke enters the detector and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. Standard Features Signals are processed in the comparator, and • Low Profile, 1.5" High when two consecutive signals exceeding the basic level are received within a specified period of • 2 or 4 wire base compatibility time, the time delay circuit triggers the SCR switch • Highly Stable operation to activate the alarm signal. The Status LED lights • RF/Transient protection continuously during the alarm period. • Low Current, 451 A nominal • Built-in power/alarm LED • Non-directional smoke chamber • Vandal resistant security lockin feature • Magnetic detector operation check • Compatible with PFS SIH-24F Ionization Detectors • Relay bases available Pro uct Listings Underwriters Laboratories Factory Mutual CSFM M72.57-410:)07 PRINTED IN USA ( REV-A i UJI1, _�d 15, 15/75, 30, 75 & 110 CANDE" INC. I1L 1971 S_i RORE PRODUCTS F L Standard 1971 Listed Strobes for ADA Applicationsheelock's popular line of fire alarm signals and speakers is now available with UL 1971 Listed strobe options. Choose from 15. 15175, 30, 75 and 110 candela models for Americans with i Disabilities Act (ADA) applications meeting the latest NFPA/ F ANSI Standards. R ( R Description f Wheelock's new line of strobes and combination audible and " E speaker strobe signaling products is designed for ADA applications while meeting the latest requirements of NFPA 72 (the National Series Fire Alarm Code),ANSI 117.1 (the American National Standard for sails: Series Accessible and Usable Buildings and Facilities), and UL Standard lS3/LS3MrMS3/IS3 LS/LSMiMSiIS ISI/LSIWMS1iISI 1971 (Signaling Devices for the Hearing Impaired). These new strobe products, when property specified and installed in accord- ance with NFPA/ANSI Standards, can provide the Equivalent Fa- cilitation allowed under ADA Accessibility Guidelines (ADAAG General Section 2.2)by meeting or exceeding the illumination which results from ADA's strobe intensity guideline of 75 candela at 50 `_ --.... —._- feet. This is an illumination of 0.030 lumens per square foot (foot Icandles). Features* 1 • Underwriters Laboratories (UL 1971) Listings, Factory Mutual, -` California State Fire Marshal, New York City MEA and Chicago 1 BFP approvals on selected models (see Ordering Information and Specifications) Stifles• Designed to meet or exceed NFPA/ANSI Standards and ADA HS/Hs2 Accessibility Guidelines LSN Msr lsh 1ISNw • All models meet ADA guideline for minimum one flash per second across the Listed voltage range • Low current draw with low temperature compensation to reduce power consumption and wiring costs • 15,30 and 75 candela models Listed for wall or ceiling`mounting with the industry's widest selection of audible/speaker combi- nations nations R )��" I i• 15/75 candela wall mounted models Listed at 15 candela under R C UL 1971 and exceeding a near-axis 75 candela intensity for ADA 9f t guidelines with low current draw *, w. • 110 candela models Listed for wall mounting in larger rooms and in sleeping areas Series snrin, Series • Convenient strobe/plate retrofit assembly for upgrading strobes MT+ LS/LSM/MS/IS MIL t LSASM,MS.1S MIL f IIS in existing installations • Polarized 12 & 24 VDC models with wide Listed voltage range, using filtered (DC) or unfiltered(FWR) input voltage • Durable Lexano strobe lens and housing for extra protection and long service • Attractive flush or surface mounting options to standard electrical t backboxes• Fast installation with in/out screw terminals using #12 to #18AWG wiring ;:ni 41 j E : • Compliance with RFI limits in Part 15, Class B for compatibility with sensitive detection and communication circuits Series SERIES E-70+LS/LSM/MSilS E-90+LJ/LShI/MS/IS Copyright 1994 Whuulock,Inc.All rights reserved ET-1070+LS/LSM;MS/I$ ET•1090+LS/LSM/MS/I3 CII-O+ LS/LSM/M&IS CH C+ LS/LSlrl/41S/IS 1 Wheelock's patented LS, LSM, MS, IS and HSW Series strobe designs (with additional patents pending) offer fire alarm system designers,specifiers and Installers the Industry's widest selection of UL 1971 Listed strobe products.Wheelock's new strobe family + Is designed for ADA applications with maximum performance,reliability and cost-effectiveness while meeting or exceeding the latest UL/NFPA/ANSI requirements. LS Series - - MS e i S r es LS Series strobes are Listed at 15 candela intensity, with a For larger areas, Wheelock's MS Series strobes are Listed at I light dispersion pattern that exceeds UL 1971 requirements 30 candela intensity.One MS Series strobe will cover a 30'x30' and meets NFPA/ANSI requirements for indirect viewing in room when properly wall or ceiling' mounted per NFPA/ANSI rooms and direct viewing in corridors. One LS Series strobe Standards. The MS Series strobes are available in the same will cover a 20'x20' room when properly wall or ceiling' stand alone and audible/speaker combination models as the mounted in accordance with NFPA/ANSI Standards.LS Series LS and LSM Series. strobes are available in a wide range of stand alone models and audible/speaker combination models, including Whee- IS Series lock's unique MT Multitone Signals and popular MIZ Mini- Wheelock's IS Series strobes are Listed at 75 candela intensity Horns,CH Chimes, ET Speakers and E Speakers. For retrofit for additional coverage capability. One IS Series strobe will applications, the model LSP Strobe/Plate Assemby makes it cover a 40'x40' room when properly wall or ceiling' mounted easy to upgrade existing signaling devices to meet the latest per NFPA/ANSI Standards. IS Series strobes e available in visible signaling requirements. the same stand alone and audible/speaker rcombination LSM Series models as the LS, LSM and MS Series. (Available in June) LSM Series strobes are also Listed at 15 candela intensity HSW Series under UL 1971 and exceed a near-axis 75 candela intensity. For very large areas and sleeping areas, Wheelock's HSW LSM Series strobes are designed only for wall mounting, in a Series strobes are Listed at 110 candela intensity. One HSW vertical orientation, in accordance with NFPA/ANSI require- Series strobe can be used to cover a 50' x 50' room or to ments for 15 candela strobes, yet meet a 75 candela ADA awaken sleeping occupants (within 16' of the strobe) when . guideline with low current draw.They are available in the same properly wall mounted per NFPA/ANSI Standards. The HSW stand alone and audible/combination models as the LS Series, Series strobes are available in stand alone models or in com- wilh attractive flush or surface mounting options to standard bination with the MIZ Mini-Horns. They are also offered with electrical backboxes and convenient in-out wiring terminals to the model HSPW Strobe/Plate Assemby for combination with speed installation. (Available in May) a wide range of audible or speaker appliances in new or retrofit applications. 'Refer to ADAAG present limitations on ceiling mounting. LSM POLAn LIGHT DISTRIBUTION UL 1971 POLAR LIGHT DISTRIBUTION 15,75 CANDELA 15,30,75,110 CANDELA LS r 40cd Ls ' 40cd MS 80cd IS f30cd LSM f S W REMINDER: See Wheelock's Alarm Signals for Fire and Life Safety Systems catalog (Rev. 1093) for non-Ut. 1971 product Information. The UL 1639 strobe products In this catalog.will no longer be Listed for public mode fire protection service If manufactured after April 1, 1994. Contact your Wheelock representative for availability of UL 1638 strobe products. I Ordering Information and Specifications (24 VDC Signals) 24 VDC 2FR odel Order Strobe dBA Current Mounting A royals SIGNALSode Code Candela (010 f< 0-44 vdc 0 lions UL CFM p FM MEA BFP - LS LS 5174 15 080 D X X Strobes LS15175 15 X LS3 O80A,J XX 5176 15 080 l X X X LSP5180 15 .080 E,R LSM LSM 5171 15/75 X X X Strobes LS1 5172 15175 115 0 X A r Mfiv Jul LS3 .115 A,J X A r Jul 5173 15/75 115 L X A rLSP 5179 15/75 .115 Jul MS MS 24 VFR 5316 30 E,S X r Jul Strobes MS1-24 VFR 5317 30 •135 D X A r MS3-24-VFR5319 .135 A,J X A r MSP 24 HFR 30 . 335 L X A r IS IS-24-VFR 5320 135 E,R X A r Strobes IS1-24-VFR5351 75 225 D Mar Jun M Se 5352 75 .225 A,J Mar Jun Ma Jun Sep IS3 24 VFR 5353 75 PP5 ISP 24 VFR 5354 75 L Mar Jun mayJun Se NSW NSW 24 HFR 225 E,R Mar Jun May Jun Se Strobes HS2W-HFR 5177 100 .230 D X X X X Mom_ 5181 110 - .230 C,K X X HSPW-24-HFR 5181 110 230 X X may MIZ MIZ-24-LS-VFR 5191 15 E'R X X X X Ma Mini-Horns MIZ 24 LSM-VFR 90 092 B,C,K X X X 5176 150 90 .147 B,C,K Mar May Ma Ma Au MIZ-24-MS-VFR 5376 30 90 .147 MIZ-24-IS-VFR 5358 75 B,C,K Mar Ma Mar - MIZ 24 NSW HFR 5192 110 237 B,C,K A r Jul Jun Jul Oct MT MT 24 LS-VFR .242 8,C X Apr VMa Jul 5183 15 87-99 .092-.128 C,E,M,O,P,T X X Multilone MT-24-LSM-VFR 5182 15/75 87-99 .127-. 663 C,E,M.O,P,T Mar MayAu MT-24-IS-VFR 535 30 87 99 .147-. 883 C,E.M,O,P,T Mar may MT 24-IS VFR 5355 75 87-99 .237.273 C,E,M,O,P,T Apr Jul Oct MT4-24-LS-VFR 5315 15 87.99 .092 .128 MT4-24-LSM-VFR 5314 15/75 87-99 .127-. 663 N X X MT4-24-MS-VFR 5375 30 N Mar May May Jun Se MT4-24 IS VFR 87 99 .147 .183 N Apr Jun r 5370 75 87-99 .237 .273 N Apr Jul Jun Jul Ocl CH CH-CFI-LS-24-CFW 5187 15 83 Chimes CH CFI MS 24 CFVII 5322 30 1� F,G X Mar Jun CH-CFI IS 24 CFW 83 .155 F,G Mar May Jun I 5356 75 83 ..2EF ,G ArCH-OFI-LS-24-VFR 1 Jul JJun 5189 15 JJuull c t83 G, X Mar JunG•O AAu CH-OFI-LSM-24-VFR 5188 1575 83 1CH OF1 MS24 VFR 5323 a Jun1CH DFI IS 24 VFR 30 83 . G, Mar Ma 51 75 8324 G ct Ordering infor"Idtion and'Specifications (12 VDC Signals) - available in May (LS) and June (MS) 12 VDC Model Order Strobe dBA Current Mounting A royals SIGNALS Number Cade Candela @10 It @12 vdc options Ul CFM FM MEA 8Fp LS/MS LS1-12-VFR 5377 15 Strobes MS1-12 VFR .160 A,J A r Jun A r 5378 30 - .270 A,J MayAug_ Jun LSP I2-V R 5379 15 .160 MSP 12 VFR 5380 30 -ER A r Jun A r MIZ MIZ 12 LS VFR •270 E,R May AugJun Mini Horns MIZ 12 MS VFR 5381 15 88 .170 B,C,K Ma Jul May 5382 30 88 .280 B,C,K Jun Se Jun MT MT 12 LS VfR 5383 15 87.99 .170 .260 C,E,M,U P,T Ma Jul Ma Multitunn MT-12-MS VFR 5384 30 87-99 .280-.370 C,E,M,O,P,T Jun Se Jun MT4 12 LS-VFR 5385 15 87-99 .170-.2- N Ma Jul Ma MT4 12 MS-VFR 5386 30 87 99 .280-.370 N Jun Jul Jun Notes: IMTHESE All 2 vdc models are Listed for 20 31 vdc input and 12 vdc models for 12-15.6 vdc input using either filtered or unfiltered (FWR) input voltage. 2, dBA e at measured at 10 ry an anechoic chamber with nominal input voltage. 3. MT Multilone Series has range of current and dBA ratings with eight field- tones and High or Standard d8A servings. 1. CH Chime Series can be set for single stroke or vibrating mode. 5. Strobes require continuous input flash properly;do na1 use strobes on coded or interrupted circuits. S. Models code suffix:V=vertical lens;C=ceiling lens;H=horizontal lens;F=Pra R=red plate;W=white plate. 7. Approval codes:UL=Underwriter Laboratories;CFM=California State Fire Marshal;FM=Factory Mutual;MEA=New Materials and Equipment Acceptance;BFP=Chicago Bureau of Fire Prevention. NING:CONTACT WHEELOCK FOR"SPECIFICATION SHEETS", "INSTALLATION INSTRUCTIONS"AND "GENERAL INFORMATION" ON THESE PR00HESE DOCUMENTS CONTAIN IMPORTANT NEW INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: TOTAL CURRENT REOUIRED BY ALL DEVICES CONNECTED TO SYSTEM PRIMARY AND SECONDARY POWER SOURCES; FUSE RAFINGS ON SIGNALING CIRCUITS TO HANDLE MAXIMUM INRUSH OR PEAK CURRENT FROM ALL DEVICES ON THOSE CIRCUITS; COMPOSITE FIASH fiATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW; INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS; STROBES IN OPEN OFFICE AREAS;OTHER SPECIFICATION AND INSTALLATION ISSUES. INSTALLATION OF Ordering Information and Specifications (Speakers) SPEAKERS Model Order Strobe dBA Current Mounting A royals Number Code Candela 10 ft 24 vdc O tions UL CFM MEA BFP E Series E-7025-LS•24-VFR 5195 15 81 -90 .080 F,G,Q X X E-7025-LSM-24-VFR 5193 15l75 81 -90 .115 F,G,Q Mar Me May Au .w 25 vrms E-7025-MS-24-VFR 5326 30 81 .90 .135 F,G,Q Mar May 1/4-2 wafts E 7025 IS 24-VFR 5360 75 81 •90 .225 F,G,Q A r Jul Jul Oct E-9025-LS-24•CFW 5201 15 81 -90 .080 F,G X X E 9025 MS 24-CFW 5327 30 81 -90 .135 F,G Mar Ma E-9025-IS-24-CFW 5363 75 81 .90 •225 F,G r Jul Jul Oct E Series E-7070-LS-24-VFR 5199 15 81 -90 .080 F,G,Q X X E-7070-LSM•24-VFR 5197 15/75 81 -90 .115 F,G.O Mar May May A ug 70 vrms E-7070-MS-24-VFR 5329 30 81 -90 .135 F,G,Q Mar may 1/4-2 watts E-7070-IS-24-VFR 636 775 81 -90 .225 F,G,Q r Jul Jul Oct E 9070.LS 24-CFW 5202 15 81 -90 .080 F,G X X E-9070-MS-24-CFW 5331 30 81 -90 .135 F,G Mar May - E-9070-IS-24-CFW 5364 75 81 -90 .225 F,G Apr Jul Jul Oct ET Series ET-1070 LS 24-VFR 5205 15 78-96 .080 F GO X X ET-1070-LSM-24-VFR 5203 15/75 78-96 .115 F,G,Q _ Mar May May Aug - 25/70 vrms ET-1070-MS-24-VFR 5334 30 78 96 .135 F,G,Q Mar May 1/8-8 watts ET-1070-IS-24-VFR 5366 75 78-96 .225 F,G,Q Apr Jul Jul Oct ET-1080-LS-24-VFR 5209 15 78-96 .080 F,G,Q X X ET-1080-LSM-24-VFR 5207 15/75 78-96 .115 F,G,O Mar May may Au ET-1080-MS 24-VFR 5335 30 78-96 .135 F,G,Q Mar m ay ET 1080 IS 24•VFR 5368 75 78-96 .225 F,G,Q r Jul Oct ET-1090-LS-24-CFW 5211 15 78-96 .080 F,G X ET 1090 MS 24-CFW 5338 30 78 96 .135 F,G Mar ET-1090-IS-24-CFW 5369 75 78 96 .225 FG A r Jul Oct Speaker Notes: 1. All speaker models are shown with 24 vdc strobes. 2. E Series speakers have separate 25 vrms and 70 vrms models. All E Series models have field selectable taps for 114, 112, 1 or 2 watt operation. 3. ET Series speakers operate on either 25 vrms or 70 vrms. All ET Series models have field selectable taps for 1/8, 114, 1/2, i, 2, 4 or 8 waft operation(4 watt tap not available with 25 vrms Input). Mounting Options OPTION TYPE MAXIMUM WIRES IN BACKBOX BACKBOX #18 016 #14 #12 ) A FLUSH 1-GANG X 2' 4 4 4 4 B FLUSH 1-GANG X 3-1/2' 4 4 4 q C FLUSH 2-GANG X 34/2' 8 8 8 8 ll FLUSH 4' X 4'X 1-1/2' 4 4 4 E FLUSH 4'X 4' X 2-1/8, 8 8 6 A F FLUSH 4'X 4'X 2-1/8' + 1-112' RING 8 8 8 4 G FLUSH 4' X 4' X 2-1/8' + 2-1/8, RING 8 8 8 8 H SEMI-FLASH 4'X 4'X 1-1/2' + ISP 8 B 8 4 SEMI-FLUSH 4' X 4' X 2-1/8' 4 ISP g 8 g J SURFACE WIREMOLD 1-GANG X 1-3/4' 8 K SURFACE WIREMOLD 2-GANG X 1-3/4' 4 4 4. 4 SURFACE BB 4 4 4 4 M SURFACE BB + ISP 4 4 4 4 N SURFACE DB8 8 8 8 4 0 SURFACE ORB + ISP 8 8 8 4 ► SURFACE 108 8 8 8 A SURFACE SBB 8 8 8 8 Fi SURFACE SBL1 8 8 8 g S SURFACE SBL 8 8 8 8 T I RETROFIT I FSB1+RP 8 8 8 8 8 8 8 g ©CAUTION: The Mounting Options table shows the maximum number of field wires (conductors)that can enter the backbox used with each mounting option. If these limits are exceeded, there may be Insufficient space in the backbox to accomodate the field wires and stresses from the wires could damage the product.Although the limits shown for each option comply with the National Electrical Code(NEC), Wheelock recommends use of the largest backbox option shown and use of approved stranded field wires whenever possible, to provide additional wiring roorp for easy installation and minimum stress on the product from wiring. Ordering Information (Mounting Accessories) Wiring information MODEL CODE DESCRIPTION All models have In-out wiring terminals Be-R 2830 4'x 4'X 1-1/2'SURFACE BACKBOX (or double leads for Series LSP/LSPM/ DBB-R 2055 4'X 4'x 2.ve,SURFACE BACKBOX ISP/HSPW).Stand alone strobe models ISP-R 5306 5-1/4'X 5.1/4'X 11/16'MOLDED EXTENDER and Series MIZ models have single in- tOa-R 5046 5-1/4'X 5-1/4'X 2.5/8'MOLDED SURFACE BACKBOX put; all other models have dual Inputs SBB-n 3204 5-1n'X 5 1rz'X 3-irz'SURFACE BACKBOX with separate terminals for audible and SBL1-R 5342 6'X 9-112'X 1-3/4'SURFACE BACKBOX SSL•R 4995 5.1/2'X 10.5/8'X 1-3/4'SURFACE BACKBOX for strobe. Series MT and CH are pro- nP-R 5042 5.1/2'X 5.1/2'X 7/16'FS81 neTnOF1T PLATE vided with shunt wires so audible and ---__—_----_--.. —.--•--._-.__ etrohe,ran nrfinvinfty hr,Wirrrf in r,rallol In olinrah nr1 A Ringlr, r•irr.rnt The 1991 passage of the ADA law expanded the use of visual and audible emergency alarms to notify the increasing population of hearing impaired people.T=AccessibilityGuidelines require that emergency warning systems for both new or altered construction and existing facilities must include both audible and visual •alarmsformance specifications. Visual alarms are now mandated throughout a building wherever members of the general public and/or employees with a disability emergency. This includes entrances, restrooms, meeting rooms, hallways, lobbies, all common use areas and percentage of hotel/motel guest rooms. ADA EQUIVALENT FACILITATION WITH NFPA/ANSI STROBE COVERAGE TABLES ADA Accessibility Guidelines (ADAAG)specify NFPA 72, ANSI 117.1 requirements for strobe Illumination in a protected area depends on NFPA/ANSI strooe coverage tables are based strobe intensity of 75 candela at a maximun. applications.)To awaken people, NFPA/ANSI strobe intensity and the distance from the on extensive research conducted by indirect viewing (reflected light) distance of 50 recommend properly installed 110 candela wall strobe. The ADA guidelines of 75 canoela Icd) Underwriters Laboratories. Listing to UL feet. ADAAG General Section 2.2 allows mounted strobes in sleeping rooms. For direct at 50 feet is equal to an illumination of 0.030 Standard 1971 assures that the strobe intensity Equivalent Facilitation. The National Fire Alarm viewing applications, i.e., hallways and corri- lumens per square toot, or footcandles (tc). A 30 is consistent with these coverage tables at all Code 1993 (NFPA)and ANSI 117.1 (ANSI) pro- dors, NFPA/ANSI require 15 candela strobes cd strobe will provide equivalent illumination at viewing angles and produces an illumination of vide for such equivalent facilitation, i.e., illumi- with 100 feet spacing. For Indirect viewing appli- a distance of 30 feet,and a 15 cd strobe at 20 at least 0.030 footcandies throughout the speci- nation. NFPA/ANSI strobe intensity require- cations, in which alerting may be done by feet. The calculations are shown in the left dia- tied room size. The diagrams below show how ments vary with viewing conditions and room reflected light, the following principles apply gram. the NFPA/ANSI coverage tables meet or exceed size to provide illumination that meets or (see Strobe Coverage Table for room applica- ADA's 0.030 to illumination guideline (dotted exceeds ADA's requirement. (Refer to specific tions). Imes) to provide equivalent facilitation. 15 od 30 cd O 75 20'x20 30'x30' 40'x40' 50'x50' ILLUMINATION. CANDELA \ 70 x70' (DISTANCE)' I , 0.030 Ic EOUIVALENT ILLUMINATION t 75 ot!<�T;,. � '�' �~ LESC THAN EQUIVALENT te.g.15 cc at 25') 60 ed inn DISTANCE FROM STROBE The area enclosed by the dolled Im - es exceeds ADA's 0.030 Ic guideline 0 10' 20' 30' 4e' 50' when strobes with the indicated candela ratings are installed as shown. The maximum room size permitted by NFPA/ANSI is shown with solid hates. 15 td 1. 0.037 tc 0.037 Ic. 15 co (20'); And NFPA/ANSI provide for equivalent illumination 90 ro of non-resloential floor areas can be protected using fewer,nigh Intensity strobes within the same using one or two strooes with Intensity ranging from room size as shown below.We estimate that auoui 15 to 110 canoela. rr. 30 m 1 0.033 Ic - 0.033 Ic 3 Cd 0 40'x40' 40 x40' 40'x40' i 15 co 30 od 0.030 tc�75 cd 15m m Y .: 75 cd 75 0.030 tc - (5a), .. 3A� 15 tb 15 ed 30 ad -60 cd mIn Although Wheelock's UL 1971 Listed strobe products exceed the UL 1971 requirements for Intensity at all viewing angles as shown a In the tables below, specification and installation of these products must be based on their Listed candela ratings in conformance with NFPA/ANSI strobe coverage tables. Hr 15 cd 15/75 cd 30 cd 75 cd 110 cd An UL Min. T . LS T . LSM UL Min. T . MS UL Min. T . IS UL Min. T HS 15.0 21 100 30.0 42 75.0 90 110.0 132 13.5 20 75 27.0 40 67.5 92 99.0 129 13.5 20 38 27.0 40 67.5 89 15 13.5 20 28 27.0 40 67.5 86 99.0 121 20 13.5 20 22 27.0 40 67.5 86 99.0 116 25 13.5 20 19 27.0 40 67.5 99.0 116 30 11.3 19 19 22.5 38 56.3 87 82.5 103 35 11.3 17 17 22.5 34 56.3 70 82.5 103 40 11.3 17 17 82.5 100 22.5 34• 56.3 65 82.5 96 45 11.3 15 16 22.5 30 56.3 62 50 8.3 10 15 16.5 20 41.3 42 60.5 92 55 6.8 8 15 13.5 16 49.5 86 60 6.0 33.8 35 49.5 79 8 15 12.0 16 30.0 33 44.0 76 65 5.3 8 15 10.5 16 26.3 31 70 5.3 8 15 10.5 16 38.5 59 75 4.5 8 15 9.0 16 2 .3 31 38.5 45 80 4.5 222.5 31 33.0 43 7 15 9.0 14 22.5 30 33.0 42 85 3.8 7 15 T 5 14 18.8 27 90 3.8 6 14 7.5 13 18.8 27.5 41 " 26 27.5 36Wall/Ceilin Vertical _ 15 cd 15/75 cd_ 30 cd 75 cd 110JcdAn le in de . UL Min." T LS T . LSM UL Min."" T MS UL Min." T IS UL Min.0 15.0 22 100 30.0 445 13.5 21 100 75.0 90 110.010 13.5 21 100 27.0 42 67.5 88 99.015 13.5 20 100 27.0 42 67.5 87 99.015 13.5 19 27.0 40 67.5 83 99.0 100 27.0 38 67.5 79 25 13.5 19 98 27.0 38 99.0 121 30 13.5/11.3 18 56.5 74 99.0 121 96 27.0/22.5 36 67.5/56.3 70 99.0 113 35 9.8/11.3 18 94 19.5/22.5 36 48.8/56.3 . 68 40 6.9/11.3 16 92 13.8/22.5 32 34.3/56.3 66 71.5 102 45 5.1/11.3 14 90 10.2/22.5 28 25.5/56.3 62 37.4 50 4.0/8.3 12 84 8.1116.5 24 20.0/41.3 52 29.7 78 55 3.316.8 12 77 6.6.�13.5 24 16.3/33.8 48 4.2 62 60 2.7/6.0 9 70 5.4112.0 18 19.8 51 13 65 2.4/5.3 g .5/30.0 44 19 8 48 63 4.8/10.5 16 12.0/26.3 37 17.6 45 70 2.3/5.3 8 56 4.5110.5 16 11.3/26.3 31 75 2.0/4.5 8 50 4.0/9.0 16 10.0/22.5 29 14.5 45 80 1.A/4.5 8 30 3.619.0 16 13.3 45 9 85 1.8/3.8 g .0/22.5 29 1 .2 44 20 3.617.5 16 9.0/18.8 26 13.2 90 1.8/3.8 8 8 3.6/7.5 16 39 9.0/18.8 24 13.2 23 Wheelock products must be used within their published specifications and must be PROPERLY s and operationally tested In accordance with their installation instructions at the time of installation and A least twice saaYear or mo edoffennand in amust be ccordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing Underwriteers'Laboratories(UL),ualified National Electriersonnel for cal Code er NEC),Occupational Safety and Health Administration ration In accordance with all of the latest l Fire(OSHA)local,state,countynprovince, district,federal and other applicable building and fire standards,guidelines,regulations,laws and codes including,but not limited to,all appendices and amendments and the requirements of the local authority having jurisdiction(AHJ). ANY MATERIAL EXTRAPOLATED FROM THIS DOCUMENT OR FROM WHEELOCK MANUALS OR OTHER DOCUMENTS DESCRIBING THE i PRODUCT FOR USE IN PROMOTIONAL OR ADVERTISING CLAIMS,OR FOR ANY OTHER USE, INCLUDING DESCRIPTION OF THE PROD- I UCT'S APPLICATION,OPERATION, INSTALLATION AND TESTING IS USED AT THE SOLE RISK OF THE USER AND WHEELOCK WILL NOT HAVE ANY LIABILITY FOR SUCH USE. i Due to continuous development of out products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. Eastern Division Central Division Virginia-(703) 898-1477 Western Division Minnesota-(612) 953-0532 California - (714) 951-4761 =NATIONALS OFFICE Distributed By: 14891-4126 MEMBER WHEELOCK INC.• 273 BRANCHPORT AVENUE-LONG BRANCH, NJ 07740•(908) 222-6880 FAX: 908-222-8707 C rn(to not' 7'n�