NIP FIRE PROTECTION PERMIT FIR2011-00009
APPLICANT: KELLOG CO./STRETCH ISLAND RECEIVED: 3/1/2011
CONTRACTOR: LICENSE: EXP: ISSUED: 3/18/2011
SITE ADDRESS: 16371 E STATE ROUTE 3 ALLYN EXPIRES: 9/18/2011
PARCEL NUMBER: 122311490010
LEGAL DESCRIPTION: PCL 1 OF BLA#03-17 S 18/103 S 3/143
PROJECT DESCRIPTION: addition of two outdoor-rated pull stations, and six outdoor rated heat detectors to the existing fire alarm panel
System Information
Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations:
Fire District: 5 Flow Switches: Visual Devices: Door Releases:
Hood&Duct?:
Dry Chemical?: Pressure Switches:: Smoke Detectors: Duct Detectors:
Wet Chemical?: Zones: Heat Detectors:
Sprinkler?:
Standpipe?: SQUARE FOOTAGE FEES
Monitoring Company: First Floor: Type Amount Due Amount Paid
Monitoring Phone No.:O- Second Floor:
Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Plan $109.20 $109.20
Auto. Fire Alarm Permit $168.50 $168.50
Total: $277.70 $277.70
i
FIR2011-00009 Please refer to the following pages for conditions of this permit. 1 of 4
i
CASE NOTES
FIR2011-00009
CONDITIONS FOR
FIR2011-00009
1.) Per section 901.2.1 of the 2009 International Fire code, Statement of Compliance.
Before requesting final approval of the installation, the installing contractor shall furnish a written statement to the fire code official that the subject fire
protection system has been installed in accordance with the approved plans and has been tested in accordance with the manufactures specifications and
the appropriate installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be
aft a written statement.
X
2.) Th y is required to be fully monitored by a UL certified monitoring company.
This permit beoornes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is
by means of a progress inspectio The owner ort a gent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above
described property and struct r review and' s ctio .
OWN ER OR AGENT DATE: AC
I�
FIR2011-00009 Please refer to the following pages for conditions of this permit. 2 of 4
70 CONCRETE MECHANICAL MANUFACTURED HOME
Date By
L Footings /Setbacks Gas Piping Ribbons 0
OInteror Date By Interior-Date By Date By
00 Exteror Date By Exterior-Date _ B Set-up 0
INSULATION
Point Load/Isolated Footings Date By cn
BG 1 SLAB INSULATION --------- �
Date By Data By FIRE DEPARTMENT X
Foundation Wails Floors Date By �
Date. By Data By DECKS =
FRAMING Wells Date By
Date By Data By PROPANE TANKS D
PLUMBING vault Date ey Z
Date By OTHER
Groundwork Attic
Date By Date By Type.Date By
a.W.1v DRYWALL Type..
Int.Brace Wall Date By TI
Date By Date By
FINAL INSPECTION N
Water Line Fire Sepe ration O
Date By Date By Date By —L
O
o Pass or Request Inspect. o
Type of Insp. Fail Date Date Done By Comments
� r 1
0
0
0
0
y
0.
S
H
W
O
A
MASON COUNTY FIRE MARSHAL
$�llua= Mason County Bldg.III 426 W Cedar St
PO BOX 186 Shelton,WA 98584
i (360)427-9670 Ext.273 q
Permit #�i�
Mason County Fire Protection System Permit Application
Incomplete application will not be accepted
Owner: 5 z Is Ar'" Phone#:
Mailing Address: 1y3j1 RUM City: L40 State: .Zip: 98%
Site Address:A *k Iu AajI 4 City: State: Zip:
Parcel #: 12,231 j4v br 10 Legal Description:PCL I�UF k1A*03::n ST 3 S a
Lien/Title Holder:Sbl% As
Address: City: Auuo State: Zip:
Contractor: 5��6�V Phone#: 3( ?31— it g
Address: A) City:SjLVUAALp - State: --Zip: q 3�'
Contractor Registration#: T ME&*6 21 o i Expiration Date: d
Building Square Footage(existing & proposed): 1"�(,� 2na / 3rd /
Building Use: Lr_kkF4 Occupancy Classification: Construction Type:
Type of System: Type of Work:
Sprinkler: Wet Dry New System:
Standpipe: Wet Dry Modification:
AFA:
Hood & Duct:
Dry Chem:
Wet Chem:
Fire Pump:
UL certified Monitoring company: �cs Phone #:90)-7Q—� _
Contractors Bid Price: $�, QJ
\\CLUSTERI_HOME_SERVER\IiOME\COMMON\Community Development\BUILDINGTire Protection System Permit Application.doc
Plan Submittal Requirements
Your plan submittal shall include the following_
• Plans shall be on standard 24" x 36"paper, drawn to scale with dimensions and north arrow.
• Site and Floor plan with cross sectional and exterior elevations.
• Location of occupancy and/or area separation walls, partitions, stairway enclosures, concealed spaces, etc.
• Cut sheets and/or references for all new devices.
• Location/description of all new and existing devices.
• Battery calculations.
• Wiring diagrams per floor or zone overlaid on an accurate floor plan.
• Electrical riser diagram showing all zones, circuits, devices, and end —of— line resistors,
• Hydraulic calculations.
• Copy of Contractors bid.
Fees
The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50.
A plan review fee will be calculated at 65%of the permit fee(minimum$109.50)and is due upon submittal of permit application.
Contractor's Affidavit
I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating
the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made
;without first g approval from a Mason County Fire Marshal.
Date: 3
\\CLUSTER I_HOME_SERVER\HOME\COMMON\Community Development\BUILDINGWire Protection System Permit Application.doc
� S
Tri-Tek Systems
8527 Knute Lane NW—Silverdale,WA 98383 Fax 360.308.0254
Fire Alarm Plan Submittal
March 1. 2011
Subject Site: Stretch Island Fruit
16371 State Route 3
Allyn, WA 98524
Narrative: Addition of two outdoor-rated pull stations, and six outdoor-rated
heat detectors to the existing fire alarm panel.
Enclosures: Fire alarm plans and device specifications.
Notes: The additional devices do not add any current load
to the fire alarm panel, and will not require increasing battery
size to accommodate these additions.
CHANGES
SUBMIT CHANGES FOR APPROVAL
PRIOR TO PERFORMING WORK
J
Q Y
2 S L ILbILt� I S LO�IAJIJ ��Ir Vl1AJ��7 1 (IL-b A U]IU' 1 Gqwgo.
LU
z �
.i 1 mac= t ocn O S
0
z � e.P- FPf� 7Z_
U�
P
Table 17.6.3.5.1 Heat Detector Spacing Reduction Based on
Ceiling Height N
Ceiling Height Up to
Above and Including Multiply
Listed
ft In ft In Spacing by
0 0 10 3.0 1.00 PLA
10 3.0 12 3.7 0.91 -' 1 V
12 3.7 14 4.3 0.84
14 4.3 16 4.9 0.77 �LbZ
16 4.9 18 5.5 0.71
18 5.5 20 6.1 0.64
20 6.1 22 6.7 0.58
22 6.7 24 7.3 0.52
24 7.3 26 7.9 0.46
26 7.9 28 8.5 0.40
28 8.5 30 9.1 0.34
RISER UUGRAINI
MSTING PRODUCTION HEAT PULL HEAT HEAT HEA
FACII.TTY UVTIATING CAT H P H H H
18-2 EOL P PULL H HEAT H HEA
Eustuir_ Fu-e:�Iaiin
Co of P�uel
CHANGES
S08MiT CHANGES FOR APPROVAL
►'R,OR TO PERFORMING WORK
November 20, 2001 DF-52004 F-050
• Fire-LIT45ALaI'ms BG-12 Series
Manual Fire Alarm Pull Stations
www.firelite.com Section: Conventional Initiating Devices
GENERAL California
State Fire
The Fire•Lite BG-12 Series is a cost-effective, feature- C U` US Marshal
packed, non-coded series of manual fire alarm pull sta- s
tions. It was designed to meet multiple applications with LASTED `'-..• 7150-0075:184
the installer and end-user in mind. The BG-12 Series fea- rfRV,G
tures a variety of models including single-and dual-action S711
versions.
The BG-12 Series provides Fire•Lite Fire Alarm Control F M
Panels(FACPs),as well as other manufacturers'controls,
with a manual alarm initiating input signal. Its innovative (except BG-12LPS
design, durable construction, and multiple mounting op- andBG-12LPSP)
tions make the BG-12 Series simple to install, maintain,
and operate.
FEATURES
• Aesthetically pleasing, highly visible design/color.
• Attractive contoured shape with light textured finish.
• Meets ADA 5 lb. maximum pull-force.
• Meets UL 38,Standard for Manually Actuated Signaling
Boxes.
• Easily operated(single-or dual-action),yet designed to
IN
prevent false alarms when bumped, shaken, or jarred.
PUSH
• PUSH IN/PULL DOWN handle latches in the down po PULL DOWN
-
sition to clearly indicate the station has been operated.
• The word"ACTIVATED"appears on the top of the handle
in bright yellow, further indicating operation of the sta-
tion.
• Operation handle features white arrows showing basic
operation direction, for non-English-speaking persons.
• Braille text included in finger-hold area of operation
handle and across top of handle.
• Multiple hex- and key-lock models available.
• U.S. patent-pending hex-lock needs only a quarter-turn
to locklunlock. °
• Station can be opened for inspection and maintenance
without initiating an alarm. • Switch contacts are normally open.
• Product ID label viewable by simply opening the cover; • Can be surface (with SB-10) or semi-flush mounted.
label is made of a durable long-life material. Semi-flush mount to a standard single-gang, double-
• The words "NORMAL" and "ACTIVATED" are molded gang, or 4" (10.16 cm) square electrical box.
into the plastic adjacent to the alarm switch (located in- • Backplate is large enough to overlap a single-gang
side). backbox cutout by up to 1/2" (12.7 mm).
• Four-position terminal strip molded into backplate. • Optional trim ring (BG-TR).
• Terminal strip includes Phillips combination-head cap- • Spanish version (FUEGO) available (BG-12LSP).
tive 8/32 screws for easy connection to Initiating Device • Designed to replace the popular BG-10 Series.
Circuit (IDC). • Models packaged in attractive, clear plastic (PVC),
• Terminal screws backed-out at factory and shipped ready clamshelI-style, Point-of-Purchase packages. Packag-
to accept field wiring (up to 12 AWG/3.25 mm2). ing includes a cutaway dust/paint cover in shape of pull
• Terminal numbers are molded into the backplate, elimi- station.
nating the need for labels.
This document is not intended to be used for installation purposes. We try to keep our ' O �oo
product information up-to-date and accurate. We cannot cover all specific applications or
anticipate all requirements. All specifications are subject to change without notice. For
more information,contact Fire-Lite Alarms,One Fire-Lite Place,Northford,Connecticut
06472. Phone:(800)627.3473, Toll Free FAX:(877)699-4105,FAX Back:(888)388- ENGINEERING 8 MANUFACTURING
3299. Made in the U.S.A.
DF-52004— Page 1 of 2
CONSTRUCTION ties Act(ADA)or per national/local requirements. Manual
• Cover, backplate and operation handle are all molded Stations shall be Underwriters Laboratories listed.
of durable polycarbonate material. 'NOTE: The words FIREIFUEGO"on the BG-12LSP shall a -
P
• Cover features white lettering and trim. pear on the front of the station in white letters,approximately 3/
• Red color matches System Sensor's popular a"high.
SpectrAlertTm horn/strobe series. PRODUCT LINE INFORMATION
OPERATION Model Description
The BG-12 manual pull stations provide a textured finger- BG-12S Single-action pull station with pigtail connec-
hold area that includes Braille text. In addition to PUSH tions, hex lock.
IN and PULL DOWN text,there are arrows indicating how BG-12SL Same as BG-12S with key lock.
to operate the station, provided for non-English-speaking
persons. BG-12 Dual-action pull station with SPST N/O
Pushing in and then pulling down on the handle activates switch,screw terminal connections,hex lock.
the normally-open alarm switch. Once latched in the down BG-12L Same as BG-12 with key lock.
position, the word "ACTIVATED" appears at the top in BG-12LSP Same as BG-12L with English/Spanish
bright yellow, with a portion of the handle protruding at (FIRE/FUEGO) labeling.
the bottom as a visible flag. Resetting the station is simple: BG-12LOB Same as BG-12L with "outdoor use" listing,
insert the key or hex (model dependent), twist one quar- Includes WBB outdoor backbox, and sealing
ter-turn, then open the station's front cover, causing the gasket.
spring-loaded operation handle to return to its original
position. The alarm switch can then be reset to its normal BG-12LO Same as BG-12L with "outdoor use" listing.
(non-alarm) position manually(by hand)or by closing the Does not include backbox.
station's front cover,which automatically resets the switch. BG-12LA Same as BG-12L with auxiliary contacts.
SPECIFICATIONS BG-12LPS Same as BG-12L with presignal feature.
Physical Specifications: BG-12LPSP Same as BG-12LPS with English/Spanish
(FIRE/FUEGO) labeling.
BG-12 SB-10 WP•10 WBB SB-10 Indoor use backbox.
WP-10 Outdoor use backbox.
Height: 5.5 inches 5.5 inches 6.0 inches 4.25 inches WBB Outdoor use backbox.
(13.97 cm) (13.97 cm) (15.24 cm) (10.79 cm)
Width: 4.121 inches 4.121 inches 4.69 inches 4.25 inches
(10.47 cm) (10.47 cm) (11.91 cm) (10.79 cm)
Depth: 1.39 inches 1.375 inches 2.0 inches 1.75 inches
(3.53 cm) (3.49 cm) (5.08 cm) (4.445 cm)
5200411 IDI
1.390' i
Electrical Specifications: (35.306)
Switch contact ratings: gold-plated, rating 0.25 A § 30 _
VAC or VDC. r��
Wire Length
ENGINEERS' & ARCHITECTS' Strip Gauge
SPECIFICATIONS
Manual Fire Alarm Stations shall be non-code,with a key- { —
or hex-operated reset lock in order that they may be tested, T 1.000"
and so designed that after actual Emergency Operation, ! (25.40)
they cannot be restored to normal except by use of a key or
hex. An operated station shall automatically condition it- _
self so as to be visually detected as activated. Manual
stations shall be constructed of red colored LEXANO (or polycarbonate equivalent)with clearly visible operating in- 0.750"
(19.0
structions provided on the cover. The word FIRE shall ap- 5.500"
pear on the front of the stations in white letters, 1.00 inches (139.70)
(25.4 mm) or larger.' Stations shall be suitable for sur-
face mounting on matching backbox S13-10; or semi-flush (min)
mounting on a standard single-gang, double-gang, or 4"
(10.16 cm) square electrical box, and shall be installed
within the limits defined by the Americans with Disabili-
Page 2 of 2 — DF-52004
July 15,2004 DF-50673- F-850
Flre•LITeJALarms 302 Series
Rate-Anticipation Heat Detectors
www.firelite.com Section:Conventional Initiating Devices
GENERAL California
i, State Fire
The Thermotech 302 Series rate-anticipation heat detec- UC Marshal
tors operate within a controlled range of two to three de- `
APPROVED
_ 7270-0021:001
grees of their set points, regardless of the speed or rate of LISTED J.1.5H3M3.AY � (All)
temperature rise. These detectors are available in either
135•F or 194•F ratings. S539
The 302 Series are normally-open devices designed es-
E35018A
pecially for fire detection and alarm systems.
FEATURES
• Immediate response. The 302 Series activate
whenever ambient air temperature reaches a
detector's setting,eliminating the thermal time lag
inherent in conventional heat detectors.
• Eliminates false alarms.The 302 Series do not
respond to momentary temperature fluctuations
below the selected temperature. Model ' ode[ t
• Universal application. The 302 Series can be
used in all areas for any type of occupancy.
• Self-restoring.
• Hermetically sealed,shock resistant, corrosion
resistant. and tamper-proof.
PRINCIPLES OF OPERATION
The 302 Series rate-anticipation heat detectors re-
spond and activate the fire alarm immediately when- Model 302-EPMModel
ever the ambient temperature reaches the preset
temperature setting. Under rapid heat rise condi-
tions, the rate-anticipation feature enables the de-
tector to respond one to three degrees ahead of
the setting.At the same time, however, it does not
respond to momentary temperature fluctuations be-
low the selected protection level, thus eliminating Model 302-H
false alarms. When temperature drops back down
below the protection level, the detector automati-
cally resets itself.
DIMENSIONS (Model 302)
Total overall length:4-1/8"
Base diameter: 2" APPLICATION INFORMATION
ELECTRICAL RATINGS 302 Series detectors have a smooth-ceiling UL rating of
Voltage Current 50' x 50' (15.24 x 15.24 meters) and are the only type of
6-125 VAC 5 amps heat detectors having such a rating on both fixed tempera-
ture and rate anticipation. The 302-H is designed for hori-
6-25 VDC 1 amp zontal mounting and UL rated for 40' x 40' (12.19 x 12.19
125 VDC 0.5 amp meters).
This document is not intended ur be used for installation purposes. We try to keep our product ' O 900
information up-to-date and accurate. We cannot cover all specific applications Or anticipate all
requirements. All specifications are subject to change without notice. For more information,
contact Fire-Lite Alarms,One Fire-Lite Place,Northford,Connecticut 06472. Phone.(800)627-
3473, Toll Free FAX.(877)699-4105,FAX Back(888)388-3299 ENGINEERING 8 NIA(pIFAi;T111N6
WEB www.firelite.com
DF-50673-07/15/04 — Page 1 of 2
PRODUCT LINE INFORMATION
Thermotech Model 302 Series Rate-Anticipation Heat Detectors
MODEL NUMBER DESCRIPTION REFER TO
302-135 135°F Interior Vertical Mounting, FM and UL.
302-194 194°F Interior Vertical. Mounting, FM and UL. Note 1 below.
302-AW-135 135°F All-Weather Vertical Mounting, FM aEUU
Note 2 below.
302-AW-194 194°F All-Weather Vertical Mounting, FM a
302-ET-135 135°F All-Weather Vertical Mounting, FM and UL.
Note 3 below.
302-ET-194 194°F All-Weather Vertical Mounting, FM and UL.
302-H-135 135°F Interior Horizontal Mounting, FM and UL.
Note 4 below.
302-H-194 194°F Interior Horizontal Mounting, FM and UL.
302-EPM-135 135°F Explosion-Proof Mounting, UL..
Note 5 below.
302-EPM-194 194°F Explosion-Proof Mounting, UL.
AP-P Decorative white plastic adaptor plate for mounting
302 and 302-AW to 4" outlet box.
Note 1: For interior mounting in any atmosphere that is
compatible with terminal screw type connections.
UL rating 50' x 50' (15.24 x 15.24 meters).
Note 2: Humitically sealed for moisture-proof or dust-
proof installations. Requires no special backbox
f when the all-weather leads are properly spliced
r-/ to 'THW' or equivalent type wire.
Note 3: Humitically sealed for moisture-proof or dust-
proof installations. Requires no special
backbox. Has plastic hexagonal wrench grip
bushing with 1/2" (1.27 cm) conduit threads for
attachment to threaded hub cover, or any outlet
box.
Note 4: Same as model 302 except designed for hori-
FINE SILVER zontal mounting. UL rating 40' x 40' (12.19 x
CONTACT POINTS 12.19 meters).
EXPANSION STRUTS Note 5: Explosion-proof for installation in hazardous lo-
cations. Has hexagonal wrench grip bushing
with 1/2" (1.27 cm) conduit threads for attach-
HIGH EXPANSION ment to threaded hub cover of Series JL fixture
SENSING SHELL 0.040 fitting as manufactured by Killark Electric Co., or
ANODIZED ALUMINUM equal.
HEAT ANTICIPATION
CONTROL SLEEVE
SETTING SCREW
DEVCON
HERMETIC SEAL
Cut-Away View, ACTUAL SIZE
Page 2 of 2 — DF-50673•07/15/04
r
Fr L-4-
l2- Z LY 001D
THESE PLANS MUST BE
ON THE J06 SITL
FOR INSPECTION.
w '..ice.!
MASON COUNTY 16�r._ ',►R �i,�L
i r I Y
[�� ! C
'!Qcl,JE CT TO FIELD INSFECTI'nN
ALL APPLICASL CODES SHALL APPLY. ERRORS
AND/OR OMISSIONS ON PLANS ARE SOLE AF-
SPONSIBILITY OF OWNER/CONTRACTOR. COARL--C-
TIONS REQUIRED FROM FIELD;NSPECTION SHALL
ON AT ON,'NER/CONTr4ACTOR'S EXPENSE. THIS AP-
OnOYAL DOES NOT GRANT TO ANY PERSON THE
MONT 10 VIOLATE ANY CITY OR STATE LAWS.
Tri-Tek Systems
8527 Knute Lane NW—Silverdale,WA 98383 Voice 360.373.8373 Fax 360.308.0254
INSTALLATION BID
February 10, 2011
Bid for: Steve Johnson Construction
Project: Stretch Island Fruit Processing Building Canopy Area
.Attention: Brian
Fire Alarm Expansion
Tri-Telr Systems shall provide, install,and test-before the Mason County Fire Marshal all
equipment listed in this bid. This equipment shall be connected to the existing fire alarm
system-
7 Firclite outdoor-rated heat detectors
2 Fire]ite BG-121,OB outdoor-rated pull stations
Installation, conducting, plans, permits, testing
Total 2,857.00