Loading...
HomeMy WebLinkAboutFIR2014-00031 Alarm System - FIR Application - 9/13/2014 #1454 MASON COUNTY FIR20DEPARTMENT OF COMMUNITY DEVELOPMENT Mason County Bldg. III, 426 West Cedar Street FIRE PO Box 279, Shelton, WA 98584 www.co.mason.wa.us (360)427-9670 Belfair(360)275-4A &f+A-L269 ' Mason County Fire Protection System Permit Application �- t3' Y PP Incomplete applications will not be accepted Owner: S' TTt,E t I�C.EP-ct�� (�R-�y P Phone#: 0 tC) Mailing Address: 2-3\ 'V.1 ►L-►-t NS O 0- City:PT• ORL NPieD State: WA Zip: q$3(¢.Cp Site Address: 960 0LD t3FvrAg(z Vwy City: P,>5LS--Pi f — State: WA Zip: R �'--�► Parcel#: 123Z0- L "k(D-OU 1(7 Legal Description: Te t O F t-JE 5G ir- Lien/Title Holder: fy , _Address: City: State: Zip: Contractor: t NTH i.la5 f STFit A G • Phone#: 3W Address:'Po P>c)X 5q-Z City:'K. 0 R-(-4W:A D State. - Zip: (o( Contractor Registration#: ITATs�,L 1 CMS q Expiration Date: I au 114 Building Square Footage (existing&proposed): 1st ' 2nd / 3rd / Building Use: RG. P%c.-Tlv►Tj Occup4ncy Classification: Construction Type: \/t3 ( t'5 U RSC-X2--f Type of System: Type of Work: Sprinkler: New System: X, Wet Dry Modification: Standpipe: Wet Dry Automatic Fire Alarm: Fire Pump__RECEVED Hood&Duct: SEP 13 20% Dry Chem: Wet Chem: .PWAR_SL UL certified Monitoring company: N'Nie-M Gar I;�(Z- Phone#: S(V-152-241 O Contractors Bid,Price: $ �8 .� • 34 C:\Users\blr.MASON\Desktop\PAC\Fire Protection System Permit Application.doc Plan Submittal Requirements Your plan submittal shall include the following: • Plans shall be on standard 24"x 36"paper, drawn to scale with dimensions and north arrow. • Site and Floor plan with cross sectional and exterior elevations. • Location of occupancy and/or area separation walls,partitions, stairway enclosures, concealed spaces,etc. • Cut sheets and/or references for all new devices. • Location/description of all new and existing devices. • Battery calculations. • Wiring diagrams per floor or zone overlaid on an accurate floor plan. • Electrical riser diagram showing all zones, circuits,devices, and end—of—line resistors. • Hydraulic calculations. • Copy of Contractors bid. Fees The permit fee will be assessed based on the submitted contractor bid for the project or a minimum of$168.50. A plan review fee will be calculated at 65%of the permit fee(minimum $109.501 and is due upon submittal of permit application. Contractor's Affidavit I certify that I am a currently registered contractor in the State of Washington. I am aware of the ordinance requirements regulating the work for which the permit is issued and certify that all work will be in compliance with this ordinance. No changes will be made without first obtaining approval from the Mason County Fire Marshal. By: Date: U — \\ (�-3 - C:\Users\blr.MASON\Desktop\PAC\Fire Protection System Permit Application.doc J Department of Labor and Industries INTELLISYSTEMS INC PO Box 44460 Olympia, WA 98504-4460 Lic: EC fNTELIx982MQ UBI: 602-220-384 Licensed as provided by Law as: t Electrical Contractor (EC06) -LIMITED ENERGY �E (EC6A) - HVAC/RFRG LTD ENERGY INTELLISYSTEMS INCA. PO BOX 592 Effective Date:7/18/2002 PORT ORCHARD WA 98366_ Expiration Date: 7/24/2014 4 k Mason County Fire Marshals Office PERMIT#: Y Commercial Fire-Flow Worksheet 360-427-9670*360-275-4467 ext.352*PO Box 584*Shelton,WA 98584 / J T Date of Application: (� '/ Best Contact Phone Number: IP Name: � xt��i'r s�P Business Name/Contractor: ' Parcel Number: /�, �" ® Address: C 51�F .1113 Use and Occupancy classification: Building Construction Type: (IBC) Square Footage: A8rr) UGA Q Non-UGA Fire flow as outlined in Appendix A: �()0 D gpm for i _hour(s) s T Closest hydrant location from furthest corner of building(as a vehicle would drive) `- Feet( j +400ft miti a jyV v CE Deduct from fire flow required: Sprinkler system: Non-high pile(-75%) Q Sprinkler system: High pile(-50%) JUN 13 2014 j 0 Monitored alarm system(-250 gpm) [3 Off-site water supply(-250gpm) 426 W. CEDAR ST. 30 foot setbacks all sides(-250gpm) GPM required(Appendix A): Deductions(GPM): Total Required: Do you have sufficient Fire Flow? [3 Yes(stop if yes) No(go to step 3) *Step 3 may be required in addition to the fire protection requirement set by the International Fire and Building Code. 13 0-500 sq/ft: No mitigation needed 501-5999 sq/ft:(one of the following must be completed) T NFPA 72 addressable fire alarm system r Maximum allowable a of 2000 sq/ft with Fire Walls E 13 6000-12,000 sq/ft(both must be completed or NFPA 13 automatic sprin r system installed) NFPA 72 addressable fire alarm system plus Maximum allowable fire area of 2000 sq/ft with Fire Walls 3 0 12,000+sq/ft: NFPA 13 automatic sprinkler system Reviewer: Date Completed: Comments: Mason County Fire Flow Work Sheet Appendix A TABLE A Required Fire Flow for Buildings Constructed Using the International Building Code and All Townhomes Urban Area Only Construction Type(1) Rural Area Only DURATION REQUIRED IIII and IV-H.T. REQUIRED DURATION(HOURS) FIRE lA and IB IIIA VA IIB IIIB VB FIRE (HOURS) FLOW I I I FLOW (GPM) WHEN TOTAL FIRE AREA IN SQUARE FEET(3)IS EQUAL TO OR (GPM) LESS THAN THESE VALUES 1 1,500 500 500 500 500 500 0(4) 1 1,500 5,500 3,700 2,600 2,100 1,600 500 '/+ 1 1,500 11,100 6,800 4,700 3,500 2,400 750 % 1 15,900 9,300 6,200 4,500 2,900 1,000 1 1,500 1 1,500 22,700 12,700 8,200 5,900 3,600 1,250 1 1'/x 1,750 30,200 17,000 10,900 7,900 4,800 1,500 1 1'/2 2,000 38,700 21,800 12,900 9,800 6,200 1,750 1'h 2 2,250 48,300 24,200 17,400 12,600 7,700 2,000 1'h 2 2,500 59,000 33,200 21,300 15,400 9,400 2,250 2 2 2,750 70,900 39,700 25,500 18,400 11,300 2,500 2 2 3,000 83,700 47,100 30,100 21,800 13,400 2,750 2 3 3,250 97,700 54,900 35,200 25,900 15,600 3,000 2 3 3,500 112,700 63,400 40,600 29,300 18,000 3,250 3 3 3,750 128,700 72,400 46,400 33,500 20,600 3,500 3 4 4,000 145,900 82,100 52,500 37,900 23,300 3,750 3 4 4,250 164,200 92,400 59,100 42,700 26,300 4,000 4 4 4,500 184,400 103,100 66,000 47,700 29,300 4,250 4 4 4,750 203,700 114,600 73,300 53,000 32,600 4,500 4 4 5,000 225,200 126,700 81,100 58,600 36,000 4,750 4 4 5,250 247,700 139,400 89,200 65,400 39,600 5,000 4 4 5,500 271,200 152,600 97,700 70,600 43,400 5,250 4 4 5,750 295,900 166,500 106,500 77,000 47,400 5,500 4 4 6,000 GREATER GREATER 115,800 83,700 51,500 5,750 4 4 6,250 125,500 90,600 55,700 6,000 4 4 6,500 135,500 97,900 60,200 6,250 4 4 6,750 145,800 106,800 64,800 6,500 4 4 7,000 156,700 113,200 69,600 6,750 4 4 7,250 167,900 121,300 74,600 7,000 4 4 7,500 179,400 129,600 79,800 7,250 4 4 7,750 191,400 138,300 85,100 7,500 4 11 4 8,000 GREATER GREATER GREATER 7,750 4 (1)Types of construction are based upon IBC. (2)In Types I and II-FR construction,only the three largest successive floor areas shall be used. (3)Each portion of a building shall be considered as a separate building when separated by one or more fire walls with a fire resistance rating of not less than IBC Table 706 and meet all requirements of IBC 706 EXCEPT:NO OPENINGS ARE PERMITTED, (4)Shall not apply to IBC"H"occupancy classifications. Minimum fire flow is 500 gpm for Group H Occupancies. RECEIVED JUN 13 20% v kar 426 W. CEDAR ST' Revised 09/01/2013