HomeMy WebLinkAboutBLD94-1574 Manufacture Bldg 5,000 sq ft see also 12317-41-00050 - BLD Letters / Memos - 12/12/1994 GARY YANDO,DIRECTOR
�oN.STA
o A u o DEPARTMENT OF COMMUNITY DEVELOPMENT
i o T z PLANNING-SOLID WASTE-UTILITIES
N Y y BLDG. III • 426 W. CEDAR • P.O. BOX 578
1864 SHELTON, WA 98584 • (206)427-9670
December 12 , 1994
Chester Loudin
P.O. Box 1980
Belfair, Wa. 98528
Re: Building permit BLD94-1574; Storage/Manufacturing buildings;
two currently proposed buildings each 5000 square feet and one
future building 7200 square feet .
Mr. Loudin:
Pursuant to the Mason County Environmental Policy Ordinance and
State Environmental Policy Act (SEPA) , environmental review is
required for this development. I have enclosed an environmental
checklist which should be filled out and returned to the county at
your convenience. Please answer all questions as completely as
possible in order to eliminate potential delays in processing.
Upon receipt of the checklist and evaluation, a threshold
determination will be issued. Processing time is dependent on the
determination but will include posting of the site and acceptance
of public comments.
If you have any questions feel free to give me a call . Thank you.
Respectfully,
Don Brush, Planner
Department of Community Development
CC:
Mike Byrne, Building Department
Recycled
I
i
GARY YANDO,DIRECTOR
SON.STgTFO
A DEPARTMENT OF COMMUNITY DEVELOPMENT
u
i o T i PLANNING -SOLID WASTE-UTILITIES
N Y 4 BLDG. III • 426 W. CEDAR • P.O. BOX 578
1864 SHELTON, WA 98584 • (206)427-9670
November 10, 1994
Mr. Rolla Boughan
Consolidated Engineering
P.O. Box 2321
Bremerton, WA 98310
RE: BLD 94-1574. "Chet's Trusses" Minimum guidelines for stormwater management.
Inadequate permanent stormwater management plan.
Mason County has reviewed the proposed stormwater drainage plan prepared for "Chet's
Trusses." The proposal does not meet minimum County requirements for commercial site
developments.
Commercial sites are required in the Mason County Parking Standards (Ordinance No. 815) to
retain surface water runoff on site or dispose of it into an area approved by the Mason County
Engineer. Recognizing that many areas of Mason County do not readily lend themselves to
infiltrating stormwater runoff, Mason County Public Works has allowed discharges from
commercial sites to occur if the rates of discharge from the site conform to Puget Sound Water
Quality Authority (PSWQA)downstream erosion control standards. These standards underlie the
requirements contained in the Stormwater Management Guidelines distributed by the Mason
County Department of Community Development.
The PSWQA Technical Manual (III-1.3 Minimum Computational Standards) requires;
1. For all computations, except for basin plans or equivalent, the minimum standard shall
be the Soil Conservation Service Unit Hydrograph (SCSUH) method (1) with the level
pool routing method, or equivalent hydrograph techniques, subject to approval of the
local government. The Santa Barbara Urban Hydrograph (SBUH) method is also an
acceptable method.
A computer simulation using the information submitted by Consolidated Engineering input into
the SBUH method, indicates that the proposed facility exceeds predevelopment discharge rates
by appreciable amounts.
Other concerns include;
1) In calculating the pre-development runoff, it appears to only address the runoff from
the front half of the property, then applies a 5 year event rain intensity to the site. It
would be to the proponents advantage to use the full site in determining pre-development
discharge rates. The employment of a 5 year storm event has little relevance in this site's
analysis.
2) Catch Basin #4 discharges stormwater from the site to the north without any control
feature. Recycled
page2
RB
3) The extent of material to be excavated/graded cannot be determined from the plan
sheets submitted. Sheet 2 of the drainage plans shows three elevation contour lines and
indicate that a 25 foot cut will be required for the building. Where this borrow material
is to be deposited is not indicated on the plans. If all the material is to be removed off
site, then the receiving site should be identified and permitted if necessary. There is a
remote possibility that the three contour lines fully describe the surface topography, but
there is no indication of the frequency of the contours or their relative elevations. The
contour lines need labeling. If the entire area contained within the contour line shown in
the northeast corner of the property were excavated 25 feet deep, the volume would be
approximately (1/2)x(70x8Ox25)/27=2,590 cubic yards.
In addition, there is no evidence for provision for temporary erosion and sediment control. At
a minimum: An ESC plan should show limited construction access to the site, provide for the
covering of soils if they are to be exposed for more than 2 days, retention of sediment on-site
through the use of structural and source control BMPs, maintenance of erosion and sediment
control BMPs through regular inspection.
In summary, the stormwater plan needs further designing and information needs to be submitted
to facilitate calculation of earthwork quantities.
ZRestfull,ssee, Planner
ment of Community Development
f
c:
Alan Tahja
Chester Loudin
MASON COUNTY
DEPARTMENT of GENERAL SERVICES
Mason County Bldg. III 426 W. Cedor
P.O. Box 186 Shelton,Washington 98584
-(206)427-9670
BUILDING PARKS& RECREATION FAIR/CONVENTION CENTER ADMINISTRATION
/Li 3 /.may
RE: Permit Number /S774,
During a recent plan review for your proposed project, it was determined
that the following information needs to be submitted prior to the building permit
being processed for approval: I
c�e- /� �cc� car �/ivt� 'S o ✓ ��oor'
5`1vt,J /o ' 7L
�i /vA D Al C_ gS 4') oo�Lj 'SD�?
Lt ft l o K ,c r
GL✓I'� o��,. n�u�h�h 4 7'�'�CT'G�yc�'�,
Once the information has been received by our department, the project
will continue to be processed.
If you should have any questions, please contact me between the hours
of 8:OOam-9:OOam, Monday-Friday at (206) 427-9670 ext . If you can
not make contact between those hours, please call and leave a message and
I will return your call as soon as possible.
Thank You,
Building Inspector
cc: Property File
LOU Y_Ial n I CAUS_�
94 --
MASON COUNTY BUILDING DEPARTMENT
PLAN REVIEWER AND INSPECTOR CHECKLIST
1994 NON-RESIDENTIAL ENERGY CODE
SLAB INSPECTION
( ) Slab insulation R-10 recommended only
FRAMING INSPECTION
( ) Attic ventilation (1/150) 5000 / 150 = 33 sq. ft. total venting
INSULATION INSPECTION
( ) Attic insulation R-19 minimum
( ) Service water heater placed on R-10 pad
( ) Service water pipe insulation R-3 .3 minimum
FINAL INSPECTION/LIGHTING INSPECTION
Interior lighting allowance (per building)
( ) 5000 sq. ft. X 1. 5 watt allowance = 7500 total watt allowance
( ) Single switch not to exceed 800 of 20 ampere circuit (16 amps)
Exterior lighting allowance (per building)
( ) 300 lineal feet X 7.5 watt allowance = 2250 total watt allow.
( ) 24 hour lighting on timed', switched, photocell or combination.
i
i
JOHNS PANEL-UUM
�P
JJ �� ZONE B
Cc DPP �� 1611
17
CP �
0 �6• f� � pT l-1 � �� •� rZ .
Wes VF
2�0 '� VGS� T '�Pli•
ZONE
\ A2
68
ZONE 64 ZONE C
B
RM99 ZONE B A
54
SO
20// 45
11 z _
X � f7 2
RM95
ZONE I
B J�
I 3]
ZONE B
/ Uninra
/ River
RM93 l
!p 3
/ 4
1 ZONE B
r 11
�24 1
IU.ZONE A2
11 n rl i( /� 4.�
1
Lou in Cjuste ,�
MASON COUNTY BUILDING DEPARTMENT
PLAN REVIEWER AND INSPECTOR CHECKLIST
1994 NON-RESIDENTIAL ENERGY CODE
SLAB INSPECTION
( ) Slab insulation R-10 recommended only
FRAMING INSPECTION
( ) Attic ventilation (1/150) 5000 / 150 = 33 sq. ft. total venting
INSULATION INSPECTION
( ) Attic insulation R-19 minimum
( ) Service water heater placed on R-10 pad
( ) Service water pipe insulation R-3 .3 minimum
FINAL INSPECTION/LIGHTING INSPECTION
Interior lighting allowance (per building)
( ) 5000 sq. ft . X 1'. 5 watt allowance = 7500 total watt allowance
( ) Single switch not to exceed 800 of 20 ampere circuit (16 amps)
Exterior lighting allowance (per building)
( ) 300 lineal feet X 7. 5 watt allowance = 2250 total watt allow.
( ) 24 hour lighting on timed switched, photocell or combination.
jjj,,,�
........
n.....................