Loading...
HomeMy WebLinkAboutFIR2014-00026 Alarm System - FIR Permit / Conditions - 9/4/2014 $oN COUN MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: Inspection Line i 967 e( 004 ext7262 " rp Mason County Bldg. III 426 W. Cedar St Shelton, WA 98584 FIRE PROTECTION PERMIT FIR2014-00026 APPLICANT: HAZY DAZE RECEIVED: 7/30/2014 CONTRACTOR: LICENSE: EXP: ISSUED: 9/4/2014 SITE ADDRESS: 1982 NE OLD BELFAIR HWY BELFAIR EXPIRES: 3/4/2015 PARCEL NUMBER: a W, 174100050 LEGAL DESCRIPTION: TR 5 OF NE SE PROJECT DESCRIPTION: FIRE ALARM SYSTEM GENERAL INFORMATION System Information Type of Use: COMM Sprinkler Heads: Audible Switches: Pull Stations: 2 Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood&Duct?: N Pressure Switches:: Smoke Detectors: 11 Duct Detectors: Dry Chemical?: N Zones: Heat Detectors: 2 Wet Chemical?: N Sprinkler?: N Standpipe?: N SQUARE FOOTAGE FEES Monitoring Company: Alarm Center First Floor: Type Amount Due Amount Paid Monitoring Phone No.:(800) 752-2490 Second Floor: Auto Fire Alarm?:Y Third Floor;: Auto. Fire Alarm Plan Chec $117.81 $117.81 Auto. Fire Alarm Permit Fe, $181.25 $181.25 Total: $299.06 $299.06 FIR2014-00026 Please refer to the following pages for conditions of this permit. Page 1 of 5 CASE NOTES FIR2014-00026 CONDITIONS FOR F I R2014-00026 1.) Own /A nt is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 2.) Vali rmit[gust be on-site. X 3.) Per ction 901.2.1 of the 2012 International Fire code, Statement of Compliance. Before requesting final approval of the installation, the installing contractor shall furnish a written statement to the fire code official that the subject fire protection system has been installed In accordance with the approved plans and has been tested in accordance with the manufactures specifications and the appropriate installation standard. Any deviations from the design standards shall be noted and copies of the approvals for such deviations shall be atta�pe he written statement. X 4.) This approved for the installation of an addressable fire alarm system installed in accordance with NFPA 72 and monitored by the UL certified monitoring company specified in the permit application, Alarm Center. FINAL INSPECTION APPROVAL is subject to the following requirements: 1. Provide smoke detectors in accordance with NFPA 72 to address spacing of a peaked ceiling in all areas. 2. Correct as needed, strobe light locations and glu-lam visual obstructions. 3. Provide corrected, updated plans to the Mason County Building Department. Deliver to 426 West Cedar St, Shelton,WA 98584, 4. Provide corrected, updated plans onsite during for inspection. X FIR2014-00026 Please refer to the following pages for conditions of this permit. Page 2 of 5 OWNER/ BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. AcKnowiedgement oT sucn IS ny signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permitlapplication becomes null &void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION, INACTIVITY OF THIS PERMIT APPLICAT N OF 180 AYS WILL INVALIDATE THE APPLICATION. i Signature Date I r OWNER - REPRESENTATIVE - CONTRACTOR i t Print Name (Circle one to indicate) i i i :i FI R2014-00026 Please refer to the following pages for conditions of this permit. Page 3 of 5 r Y Fire Systems Idlest, Inc. Phone(253) 833-1248 • Fax (253) 735-0113 206 Frontage Road North, Suite C, Pacific, WA 98047 June 19, 2014 Peninsula Concrete Contractors, Inc 5086 Warner Road Bremerton, WA. 98312 Attention: Karl Phone: 360-340-2025 Email: pccinc@rocketmail.com Reference: Hazy Daze 2020 NE Old Belfair Hwy Belfair, WA. 98528-9657 Fire Systems West Inc. will provide labor, parts, permits, programming and testing for the fire alarm system at the above referenced building for the amount of $9,803.00 plus applicable state and local taxes. Price includes only that described in the attached scope of work. All work will be performed in accordance with, and the approval of the local AHJ. Line Item #1: Fire Systems West, Inc will also provide UL listed central station monitoring for free the first year and every year thereafter will be an annual fee of $360.00. A separate monitoring contract will need to be signed for this service. Initials.. If you have any questions regarding this, please contact me. Thank you for the opportunity to provide this proposal. Sincerely, Fire Systems West, Inc. Franco Petraski Electrical Manager f ran cop@firesystemswest.corn RECEIVE., JUL 3 0 2014 426 W. CEDAR ST. Page 2 FIRE ALARM SCOPE OF WORK Hazy Daze J Included in the scope of work are the following; I FCI 7100-1 D-PNL 7100 Addressable FACP w/DACT w/ 19 inch cabinet 12 FCI B21 OLP Base, Flanged, For Use With Analog Sensor or Velociti Sensors 9 FCI ASD-PL2F Analog Photoelectric Sensor 2 SS PC2R / PC2W Horn/Strobe, 12/24 volt, red /White, multi-candela-CEILING 2 SS SCR / SCW Strobe, 12/24 volt, Red White, multi-candela-CEILING I SS P2RK Outdoor Horn Strobe 2 FCI MS-7ASF Addressable Single Action Pull Station 3 FCI ATD-RL2F Thermal Sensor ROR 15' / 1350 1. Provide labor, parts, programming and testing to install a new fire alarm system. 2. Provide design and CAD of fire alarm system. 3. Provide fire alarm permit and submittals with AHJ. 4. Provide testing of fire alarm system with AHJ. CLARIFICATIONS A) Fire Systems West will install a new fire alarm panel and devices. B) This proposal is based upon a verbal and written direction from Karl. No revised drawings were given at this point, C) This proposal is based upon no attic space or drop ceilings. D) This proposal is based on the fire alarm cabling able to be run "free air" and not in conduit. E) Any changes by the AHJ or that are requested by the owner that are outside of this proposal will require a signed change order in order for that work to proceed. F) This proposal is good for 30 days from the date of this proposal. G) All work will be performed during normal business hours, Mon - Fri, 7:00am to 4:00pm. H) CAD files must be provided to Fire Systems West at no charge for submittals. If CAD drawings are not provided we will need a signed change order in order to create them. 1) Plan review is subject to the speed of the local authority, usually less than 3 weeks. EXCLUSIONS A) We are a low voltage electrical contractor, therefore all high voltage work is excluded. B) EMT and or conduit. All EMT and or conduit shall be supplied and installed by others. C) Any extra fire alarm devices not listed above. D) Any trenching or underground work or Core drilling if necessary. E) Any additional equipment or devices required by AHJ or Owner. F) Installation of duct detectors or smoke dampers. (As per Larry Waters, Inspector) G) Prevailing wage and or certified payroll. H) Off hours and taxes. By signing you agree to the terms and conditions listed above. BY DATE 206 Frontage Road North, Suite C, Pacific, WA 98047-1023 253-833-1248 Office 253-735-0113 Fax WA ECL#FIRESWI055LW WA CI.#FIRESW1140BI RAL NOTES I SCOPE OF WORK A RY RECOMENDED MINIMUM WIRING SIZES.TYPE AND O m .r WTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY FOLLOWED. _........._... .. .—_—_—, .. .......... ....... .. ----i_..WISHING TO MAKE CHANGES WALL DO SO AT THERE OWN RISK!! iN 0 w 3 TCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN DRAWINGS w IN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST ¢ N E ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED 3, ICES WITH NO PHYSICAL OBSTRUCTIONS,THE WIRING OR CIRCUIT A' en IF SHOWN)ARE PROVIDED AS A CONVENIENCE ONLY AND AS MEANS 'ii LL m $ EN INSTALLATION OR TO DETERMINE WIRING ROUTS. ILM g GROWAREA HOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING e V m a -. -- NROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE PERMITTED. w ARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST N.FPA.WAC.AND OTHER STANDARDS AS APPLICABLE TO THE NDARDS. iECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS,FACTORY "' It LITY,ETC_FIRE SYSTEMS WEST RESERVES THE RIGHT TO 'Loy RE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENT I�+ OR BETTER QUALITY,FUNCTION AND DESIGN. I t.; I I iT _EL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS IT BE PERMITTED. !gi! I .EL BRANCHING OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS I BLE. 'ACE HAS NO FIRE SPRINKLERS I STEMS WEST IS INSTALLING A NEW FIRE ALARM SYSTEM FOR HAZY � = I LEGEND ELEVATION 1 REQUIREMENT + + I FAC CON ROLFIRE R PANEL TOP 72" CEILING :. "g'wg�g 4 HWORICIIp TROBE NIA 1.141 CEILING NIA 1 O STROBE Elite IX ' g 1 WALLD x d 8 HNIORWDSTROBE AFF gg gg I Q STROBE BAF zero- CO 42"�4R" tOtOjj f�u� I ® PULL STATION AFF s r"r ® SMOKE SENSOR NIA I I _ ® HEATSENSOR NIA I I 14t2 FPLP L"1 ———— 1612 FPLP N NEW DEVICE `Y R RELOCATED DEVICE ; i EX EXISTING LOCATION WP WEATHER PROOF 4 1 -STROBE COVERAGE AREA SHALL BE DEFINED AS: `O I 10 FT.CLG.HT. 20 FT.CLG.HT. 30 FT.CLG.HT. !vT l� 150=20'x20 30 cd=20'XZIY 75 cd=IDNW N 30 cd=30'xW 75 ed=30'X30 95cd=W V 75 cd=4dx40 95ctl=4OX4W 110 ed=JDx4V m ..__ _._....... ....__ ._...._ -._ _._.. _.. __._ 95 cd=3Vx50' 110ed=5o'x30 used=50'xw F z W 0 U z _. Zp= 009 o B S TE ADDRESS. INSTALLEFMPPUER JOB HAZY DAZE DESIGNMPPUER Z¢W 2M NE OLD BELFAIR WAY FIRE SYSTEMS WEST,WC m BELFALR WASHINGTON98FA 206 FRONTAGE ROAD NORTH.STE C Z LZLI LU PHONE:Xxx4XX4XXX PACIFIC,NAIMMGTGW 98M g a O] FAX: XXX•XXX41XXX PHONE.(25318311248 CCNTACT:PMLE FAX:253)7354113 a WASTUCEIGE:RNEBIMUOBI WAST LICENSE FIRESM055LW DESIGNER OF RECORD HAZY.DAZE RN LE g FIRE SYSTEMS WEST,AC 216 FRONTAGE ROAD NDRTN,SIE �r.l WZ PACIFIC.WASHNGTON 9047 FRCP RICHE:(253)J33120 n 15 Lr ¢0 CELL M.7016 1MEWEl.L FI'1� �' +ts a I- r *'SAC 713$0 6&1IS LL ?ICD W W= Q m VIRE ALARM N W CONTROL 1 Q G Q Z 7 PANEL Q �,� U �W 1L W } Yz¢ 1= S S Nm G� P 20 AMP DEDICATED CIRCI 4 s x q WIRE DIAGRAM 3 ; LL �AflA. xN�xaA. INITY MAP O < � w — Z O m xl N6 U 3 ......._..................—. __.--_—.. v I F E 17- 1 12'-r RAL NOTES 1 SCOPE OF WORK W 2Y RECOMMENDED NINMIUM HARING SIZES TYPE AND O m ICTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY FOLLOWED. C H W ,.WISHING TO MAKE CHANGES WILL DO SO AT THERE OWN RISKH 1CUIT ROUTING AND WAKING COUNTS ON THE FLOOR PLAN DRAWINGS w NN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST < < N ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED Z ACES MTN NO PHYSICAL OBSTRUCTIONS.THE WIRING OR CIRCUIT IF SHOWN)ARE PROVIDED AS A CONVENIENCE ONLY AND AS MEANS u $ :N INSTALLATION OR TO DETERMINE WIRING ROUTS. a N W GRV W AREA HOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING ....._......._.....__. ROTECTION EOUIPMENT-OTHER WIRE SMALL NOT BE PERMITTED. _ LL ARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST "r a 3 N-FPA,WAC,AND OTHER STANDARDS AS APPLICABLE TO THE HOARDS. J IECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS,FACTORY UT(,ETC.FIRE SYSTEMS WEST RESERVES THE RIGHT TO / i I � RE EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENT OR BETTER QUALITY,FUNCTION AND DESIGN. I 1 ( { I FL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS 1 IT BE PERWTTED- Iff � II I j 1 .EL BRANCHING OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS I BLE. I '. 'ACE HAS NO FIRE SPRINKLERS I STEMS WEST IS INSTALLING A NEW FIRE ALARM SYSTEM FOR HAZY i I i 1 LEGEND ELEVATION I i REQUIREMENT I j , FIRE IEli FAC CONTROIRPANEL TOP TT 0 I CEILING W.WDSTROBE NIA H R O CEILING STROBE N/AW, ' 1 NY=CO +g 3 WALL 80"- I H RCDSTROBE AFf «"1 I WALL 80--96' o g�o 0 3:a ILL I a STROBE AFF � - : 1 o0y d2.4r PULL STATION AFF .Pp I>�; + �Z{---------------�T SMOKE SENSOR WA . I ® W fe I HEAT SENSOR WA � ! J' y _ I 1412 FPLP 1612 FPLP N NEWDEVICE yi + . `t R RELOCATED DEVICE ( EX EXISTING LOCATION 1 WP WEATHERPROOFtz 1 STROBE COVERAGE AREA SHALL BE DEFINED AS: 1 10 FT,CLG.HT. 20 FT.CLG.HT. 30 FT.CLG.HT. PST l ICI 15 cd•20x2V 30 cd•20'xW 75 cd=20'x2V N _.... `a— 30 cd=30')W 75 cd=30'x30 95 cd=3(YxW 75 rd 4Tx4V 95 cd=AVxAO' 110 cd=a .ar _ _......--'----- .----._..._......_._.._.....----._.-. 95 cd=WxW 110 cd=50'160' 115 cd=50S6V H Z LLI O U z O Zpcc JWO JOB SNE ADDRESS: INSTALLERSUPPUER _7 HAZY DAZE SIG"UPPLIER -Z W 2020 HE OLD SELFAIR NWY FIRE SYSTEMS WEST,INC. - S� BELFNR WASHINGTON 9ASM 2%FRONTAGE ROAD NORTH,WE C z Lu a0 PHONE.XXX-XXX-XXXX PACIFlQ WASMNGTON 9M47 .5 a Si m FAX XXX-XXX-XXXX PHq�:(251I=12p CONTACT:PM LE FAX:(25h 135-0113 - 0- WASTLICENM RRESM11081 WAST LICENSE:FIRESW10SAWI DESIGNER OF RECOgD HAZY DAZE Q PHILE RRE SYSTEMS WEST,INC Q m 206 FRONTAGE ROAD XORTR STE C W Z PACIFlC.WASHNGTON 9eM7 �FACP 1S QO PHONE:(253)M-1248 CELL LL 202-IM :.AMEWELLFYI- �m„N Z U FSACk 771510 / OSJI.110 PIKE ALARM ,• w Lu m0 Q s CONTROL 1 Q N O a Z x PANEL Q ,� N 4�za a 120 VAC Q N R z = x.co o 20 A.NIP DEDICATED CIRC o' 4 WIRE DIAGRAM c.� �X.+,AGERxiE*06p1, INITY MAP N.T.S. LL a h N i -n m N CONCRETE MECHANICAL MANUFACTURED HOME O Footings !Setbacks Date By Ribbons Gas Piping CInterior Date By Interior-Date By Date _ By D 00 Exterior Date By Exterior-Date By So!- mup Point Load!Isolated Footings INSULATION Date By Ba P SLAB INSULATION -� Date By Data By FIRE DEPARTMENT Foundation Walls Floors Date By Date By Data By DECKS FRAMING Walls Date By Date By Data By PROPANE TANKS PLUMBING vault Date By— Date By OTHER Groundwork Attic Date By Type: Date By Date By D.VV.v DRYWALL Type_ Int Brace Wall Date By 0 Date By Date By y FINAL INSPECTION c m Water Line Firs Seperation � @, I Date By Date By Dale By .P Co o Pass or Request Inspect. c Ty of Insp. Fail Date atel Done By. Comments o _ 0 N O A O 7 a r: 0 y O h 3 a m 3 w co cD .A 0 Cn