HomeMy WebLinkAboutBLD2010-00361 Final Change Foundation - BLD Permit / Conditions - 3/25/2011 • Inspection Line(360)427-7262 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Phone: (360)427-9670,ext.352 Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,WA 98584 oto RESIDENTIAL BUILDING PERMIT BLD2010-00361 OWNER: DANIEL WILLIAMS CONTRACTOR: SOUTH SHORE CONSTRUCTION 360.275.0818 LICENSE: SOUTHSC016N2 EXP: 3/13/20 RECEIVED: 5/7/2010 SITE ADDRESS: 160 NE DALY DR BELFAIR ISSUED: 5/18/2010 PARCEL NUMBER: 123052300021 EXPIRES: 11/18/2010 LEGAL DESCRIPTION: TR 2A OF GOVT LOT 4 PROJECT DESCRIPTION: DIRECTIONS TO SITE: change foundation from post& pier to continuous, also adding new floor ST RT 3 TO BELFAIR, L ON ST RT 300, STRAIGHT ONTO OLD BELFAIR joists and beam HWY TO SITE ADDRESS ON THE LEFT SIDE General Information Construction&Occupancy Information Square Footage Information No. of Bedrooms: Type of Constr.: VB Type of Use: SF Insp.Area: No. of Bathrooms: Occ. Group: U Lot Size: Deck: Type of Work: RR Fire Dist.: 2 No. of Stories: 1 Occ. Load: Building:0 Garage-Detached 480 Valuation: Building Height: Occ. Status: Primary Basement: Manufactured Home Information Setback Information Shoreline&Planning Information Make: Length: Ft. Front: W 200.0 Ft. Shoreline: 61.0 Ft. Water Body: TIGER LAKE Rear: E 61.0 Ft. Slope: Ft. SEPA?: Unkn Model: Width: Ft. Side 1: N 28.0 Ft. Shoreline Desi g" Wftn Year: Serial No.: Side 2: S 40.0 Ft. Comp. Plan Desig.: Rural Plumbing Fixtures Mechanical Fixtures FEES Type Qty. Type Qty. Type By Date Amount Receipt Plan Check Fee GMM 5/7/2010 $73.00 S12010000 Planning Review Fee GMM 5/7/2010 $205.00 S12010000 Building State Fee LDK 5/14/2010 $4.50 S12010000 Building Permit Fee LDK 5/14/2010 $141.00 S12010000 Total $423.50 BLD2010-00361 Please referto the following pages for conditions of this permit. 1 of 5 J CASE NOTES FOR BLD2010-00361 CONDITIONS FOR BLD20 1 0-00 3 61 1) Approved per dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure. X 2) The proposed project must be consistent with all applicable policies and other provisions of the Shoreline Management Act, its rules, and the Mason County Shoreline Master Program. X 3) Prior to final approval, all upland areas disturbed or newly created by construction activities shall be seeded, vegetated or given an equivalent type of erosion protection (silt fencing or straw matting). X- 4) A Mason County Stormwater Management Worksheet was completed and signed as part of this building permit application. Design, sizing, placement, inspection and maintenance of stormwater management systems shall be the responsibility of the owner/agent of the developed parcel. It is the owner/agent/contractor's responsibility to ensure that Mason County Department of Public Works has approved the stormwater site plan for this parcel prior to the commencement of any development activities. *NOTE if Stormwater Management option "A" was selected on the Small Parcel Stormwater Management Application/Worksheet the document entitled "Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan" constitutes an approved plan based on the criteria listed on the application/worksheet. If the development has, or will have, a septic/drainfield system you are responsible for contacting Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this, or any other, parcel. You may also wish to consult with the septic design professional involved with the project. By calling for a final inspection of the building permit the owner/agent/contractor is acknowledging that all components of the stormwater management system have been installed as approved on the stormwater site plan. X 5) Landings and stairs must meet the same se back conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved Site Plan" to ensure these structures are shown and meet the setback conditions listed. X 6) By Qinition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure these structures meet the setback conditions listed. X ' 7) Th Jstructure has NOT been reviewed or approved as an Accessory Dwelling Unit(ADU): A second dwelling unit detached from an existing single-family dwelling for use as a completely independent or semi-independent unit with provisions for cooking, eating, sanitation and sleeping. ADUs are required to meet the requirements under Mason County Development Regulations 17.03.029. X - BLD2010-00361 Please referto the following pages for conditions of this permit. 2 of 5 8) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. X C 9) All proved plans are required to be on-site for inspection purposes. If an inspection is called for and plans are not available on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and must be collected by the Building Department prior to any further inspections being performed or approvals granted. X 10) Owne Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28. X 11) The plan review check list and corrections are part of the approved plans and must remain thereto. It is the responsibility of the applicant to make the corrections indicated on the plans. Once the plans are marked "APPROVED", they shall not be changed or altered without authorization from the Building Official. The permit holder is responsible to retain the complete approved set of plans on site for the duration of the project. Failure to comply and/or removal of approved documents will result in failure of required building inspections. X 12) This structure is approved as un-heated space. If at any time this building is to be used for anything other than what it is approved for, a change of use permit sh be applied for, reviewed and approved prior to the change. X 13) THE FOUNDATION SYSTEM SHALL BE PLACED ON UNDISTURBED, NATIVE SOIL. X 14) The"approved" site plan is required to be on-site for inspection purposes. If an inspection is requested and the"approved"site plan is not on site, then approval will not be granted. In addition, a re-inspection fee (refer to current fee schedule, minimum 1 hour)will be charged and shall be collected by the Building Department prior to any further inspections being performed or approvals granted. X 15) Concrete used for basement walls, foundation walls, exterior walls, porches, carport slabs, steps exposed to the weather, garage floor slabs and other vertical concrete work exposed to the weather shall have a minimum compressive strength of 3000 psi (IRC Table R402.2). X —?1.6-1 16) This structure is limited to U-occupancy use only (private garages, carports, sheds, and agricultural buildings.) Any other use will be in violation of the international_codes and Mason County Regulations unless a"Change of Use" permit is applied for, reviewed and approved. X 17) All construction must meet or exceed all local ordinances and the international codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. X BLD2010-00361 Please referto the following pages for conditions of this permit. 3 of 5 18) Provisions for surface/subsurface drainage control must be implemented with new construction or development on site and MUST NOT adversely impact f adjacent parcels. Under the requirements of Mason County Stormwater Ordinance, either private ditches and drains will meet requirements of the stormwater ordinance or prior approval will be granted to use an existing utility and drainage easement dedicated for that specific purpose. For further information regarding this ordinance and the REQUIREMENT to obtain an ACCESS PERMIT for the installation/construction of a driveway or access connecting from a Mason County Road, Contact the Mason County Public Works Department prior to construction at Ext 450. For any construction which is proposed to be located within 25'of a Mason County road right of way, it is suggested to contact that office to review future planned work which may affect your project. X ` 19) Placement of structure must comply with standards set forth per the international codes regarding descending and/or ascending slopes. X 20) All changes to"approved" building plans that effect compliance with the international codes as amended and adopted, or any other Mason County ordinan a or regulation, must be reviewed and approved by Mason County prior to construction. X 21) CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. X 22) All p perry lines shall be clearly identified at the time of foundation inspection. X 23) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Masi2L4counly ordinances and building regulations. X 24) All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may extend the time for action for a period not exceeding 180 days, upon the receipt of a written extension request indicating that circumstances beyond the control of the permit hold r have prevented action from being taken. No more than one extension may be granted. X � 25) Pressure treated wood manufactured after January 1, 2004 may contain high concentrations of copper which could quickly corrode metal fasteners, connectors,\and flashing. Install metal connectors approved for contact with the new types of pressure treated material. x J 26) Retaining walls needed to support a surcharge sucF as structures, roads, or to support slopes, shall require a separate building permit and approval prior to construction of the retaining wall. X BLD2010-00361 Please refer to the following pages for conditions of this permit. 4 of 5 27) By definition, propane tanks and heatpumps are structures, which must meet setback conditions. Please check your"Approved Site Plan"to ensure / these structures meet the setback conditions listed. X 28) Landings and stairs must meet the same setback conditions as any permitted structure; and, must be shown on your site plan. Please check your "Approved to Plan" to ensure these structures are shown and meet the setback conditions listed. X This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at anytime after work is commenced. Evidence of continuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied. Proof of continuation of work is by means of a progress inspection.The owneror the agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure for review and inspection. OWNER OR AGENT: DATE: (J 1 D Q -1 BLD2010-00361 Please referto the following pages for conditions of this permit. 5 of 5 r ! CC �o G CONCRETE MECHANICAL MANUFACTURED HOME o Date By r o Footings J Setbacks Ribbons r' Gas Piping D o Interoor Date ,, By interior-Date By Date By rn Exterar Date �01-fr By Exterior-Date By Set-up N Point Load J Isolated Footings INSULATION Date By D BG!SLAB INSULATION ------- - Z Date By Data By FIRE DEPARTMENT m Foundation Walls Floors Date By r' Date By Data ay DECKS FRAMING walls Date By Date By Data By PROPANE TANKS PLUMBING Vault Dale By Date By OTHER Groundwork Attic Date By Type- Dale By Date By D.w.'V DRYWALL Type- Int.Brace Wall Date BY Date By Date B r y FINAL INSPECTION 0 (D Water Line Fire Seperatioo 1�1 m Date By Date By Date 3 .Z s ` l By O m O Pass or Request Inspect. c sType of Insp. Fail Date Date Done By Comments W a _ ,� cj(D o L d r57 ! °-�t� g/6—/0 �3co ' 7a �/x %pyoj /�alz E'er N J 0 42 f,Ary is a N 0 MASON COUNTY RESIDENTIAL PLANS SUBMITTAL CHECKLIST r Owner's Name: w P� p I I gyp Date: -5 A-�y I(� Reviewed By: .to� Documents: uilding Permit Application Completed _Stormwater Checkli Planning Intake Checklist Completed, EX 1641 n ►-7 Site plan includes:Allowable building area,roof overhangs,decks,etc. nD Fire Apparatus Access Road info required? Yes/No Energy Code Application Form-O Electric wall heater O Electric central furnace O LPG Furnace O Heat pump with electric furnace O Heat pump with LPG furnace O Boiler(heat type ) O Other: Specify: 01 G Dom' s.t7 ('Q __11 1 �V Mechanical/Plumbi Application-WATER HEATER FUEL TYPEILOCATION Engineering? Yes 10 Snow load: Seismic: Stock Plan-approved snow load: Seismic: Manu actur es-4 FLO ANS Founda 'on Type: ANS ufacture thod Engine d fo%f�Z�al�i �pBa;sement Decks: Uncov over 4 x 6 and ov Construction Plans: ✓ 3 COMPLET�SETS _Plans Legible _✓Recognized Scale _✓Elevation Views (�-eiv Section _/Foundation Plan L1�eef-Framing Plan '1 Ffovr ian-Use of rooms noted(all floors) Floor Framing Plan-all floor levels including loft,crawlspace,etc. (<200 S.F.??-stairs?) lamming Plan, incl cov. porch framing Plan Details: M-*eef Taming details,truss lay-out may be needed (Hip and girder location shown) �Floorframing: ding-Does bearing-wall height exceed 10'?(Engineering may be required)Floor joists(size&spacing): X t p , Floor beams: X W,- 'headers. Typical header: Foundation: footing size,reinforcement t2Q-Ago.. to Walls-Does Concrete Wall Height Exceed 8'?(Engineering maayvrequired,see details) t all exits?Less than 30"above grade?Y/N 11�4iested-Bp-Furnace-Location of Furnace Fuel type: lq0_-F4FepfaCMove Information Shown-Fuel Type? Location(s): 11) are on Plans f)0-4sa9ed-wffH-p3Mls(shear walls)marked on plans or lateral engineering? N ng veering may be required) I'story of two story DI -45%,D2-55% C,OAfMENTS: plt4, U ENGINEERING REQUIRED Braced wall panels/brace wall lines are not marked on plans(R602.10) Amount and location of bracing does not meet minimum required in Table R602.10.1 DESIGN CRITERIA: All notes and details required as a res the engineered analysis shall be transferred onto proposed building plans. Wind 85 MPH, Exposure B(unless pr n otherwise). Seismic Zone: ,Snow_psf. IRREGULAR BUILDINGS R301.2.2.2.2 Irregular portions of structures shall be d gned in accordance with accepted engineering practice. A portion of a building shall be considered to be irregular when one ore of the following conditions occur: 1)Exterior braced wall 1' or BWP cantilevered or offset by more than 4' 2) Roof or floor is no aterally supported on all edges 2A) Portion of ro or floor extend more than 6 ft. beyond the braced wall line. 3) End of B extends more than 1 ft.over an opening more than 8 ft in width below. 4)Ope" ' in a floor or roof exceed the lesser of 12 ft. or 50%of the least floor or roof dimension. 5) Portions of floor level are offset vertically 6) Shear wall lines do not occur in two perpendicular directions. 7)When a story above grade is includes masonry or concrete construction(exc: fireplaces,chimneys,and veneer). When this applies the entire story shall be designed. In accordance with accepted engineering practice. 4:\permit tech building checklist.doc Revised 11-29-2007 4 Request To Revise An Approved Plan Permit Number: BLD240 - M 310 ( Name J4l,a L Parcel Number 1 a 305 - a3 -6COOL l Phone Number da ime 3&o ) Project Address 10 AN) 64t 3" AW Mailing Address 100 13 5`5-6 3 Rla�Lse provide a complete, detailed description of the proposed r�isi to the approved plans: not- sv-O �ire o -{� -50 bml Are two sets of the revised plans or addendum indicating the changes included? �es El No Are the approved site plans included? 4- es ❑ No Are the revisions clearly and accurately identified on the plans or addendum? Yes ❑ No Does the plan contain an engineer's or architect's lateral or vertical analysis? ❑ Yes No p If Yes, Has the engineer or architect approved this revision? ❑ Yes ❑ No Is a stamped and signed approval included with this request? ❑ Yes ❑ No (Note:No structural changes to a"designed"plan will be approved without the written consent of the engineer and/or architect of record. Does the proposed revision modify the footprint or location of the structure? ZYes ❑ No If Yes, Is a revised site plan, with all new setback dimensions included with this request? �'es ❑ No Additional Information: l 5 1)4CV_, t •lnajL Applicant's signatur 447�� - Date: Z— 2_ 3 Office Use Only Received by: Date Sent Assigned To Approved By Date Original Valuation: $ B. LJD _ �,... 1L 3 10 11 Additional Valuation: $ N W 6 2 �(' Sq. Ft x$ $ Total New Valuation $ Additional Fees: Additional Planning Dept. $ , Additional Plan Review Additional Condition /Comment A Additional Building Permit $ W�PIZtoot Additional Plumbing $ AA I Additional Mechanical $ Additional E.H. Dept. $ Other $ Total Amount Due: $ ' LRO Amount To Be Paid Up-Front$ ,r RECEIVED Woad.. FEB 13 2011 rr ,, 426 W. CEDAR ST. C� ALL IR CKS ARE MEASURED THE FURTHEST FRON OF THE BUILDING -(-+ �- eLAN R REVISION ala Iz, ; APPROVED NNING LA MAS N MUNTY DCD PLANNING L't SITE PLAN REQUI?ED TO BE ON SITE C NGES SUBJECT TO APPROfV.�AI'r. �� By -----= Dai��1--l--- c� -+d Cp / ago �+ �• ✓ / 1 A C� � _ z S( cn O o rl C oo SNimina 3H130 N0110 OS t !" 1 \H 8 n i Hl WOy ke GIbr,s�� �� ►_� c-- { NINE - -� �-LXTDN Q i0/ U APPROVED S7 • MASON COUNTY DCD PLANNING SITE PLAN REQUIRED TO BE ON SITE CHAN S SUB ECT TO APPROVA By Date � •N - Rq-swtll zvUa� get' r D o r 0 own Imo" z -+ � o -n cn Z D _ � M z p m -j s Z dm z o C� �Ca Cal � = q n � (l�aMS z Z z �r�►�e�l c23D5 a3 AT\ r � low' � , N ,. A. -62 414 A MASON COUNTY PERMIT N01�-{Gt2_6 10 - 603(0 BUILDING PERMIT APPLICATION ����4n 426 W. Cedar- P.O. Box 186, Shelton, WA 98584 Shelton (360) 427-9670 - Belfair (360) 275-4467 - Elma (360) 482-5269 -� On the web www.co.mason.wa.us APPLICANT INFORMATION �, CONTRACTOR INFOR ATI N ... Owner boxlQi � 0& U. ;NIOLrMS Company Name japyl& Mailin A ress 0 Mailing Address { City —State JA k Zip Code City State f►1 PC Zip Code Phone Other Ph. Phone Other Ph. Lien/Title Holder Contracthr'Reg. xp. E mail address E Mail Address Drivers Lic.# DOB Drivers Lic. # DOB SEPTIC /WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic Connect to Water System Name of Water System Well ►�'' Sewer System Name of Sewer System PARCEL INFORMATION - 12 Di 't P cel No Fire District Legal Description Site Address (Please incl d street nam , stre Qmb nd bo L4 r 4_ 1 ctions to it ` Will timber be cut and sold in parcel preparation?Yes r Is property within 200' of Saltwater Lake River Pond Wetland Seasonal Runoff Stream Slopes or s ' ° Is this permit submittal the result of a Stop Work Notice,Correction Notice or o r.'enforcement action?Yes/No TYPE OF JOB - New Add Alt Repai, '' Other RIMARY MENCE B' SEASONAL ❑ Use of Building �PA_11L.� —Describe Work t, Q �T r No. of Bedrooms No. of Bathrooms Square Footage- 1st Floor *AID_2nd Floor 3rd Floor Basement Deck— Covered Deck Other Sq. ft. Garage Attached Detached --i -tgarport Attached Detached MANUFACTURED HOME INFORMATION - Make Model Year Length Width Serial No. No. of Bedrooms No. of Bathrooms Type of Heat Purchase Price$ Replacement Unit? Yes/ No Installer Name Certification No. OWNER/BUILDER Acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative,or the contractor. I further declare that I am entitled to receive this permit and to do the work as proposed in the application. I declare that I have obtained the permission from all the necessary parties. If permission is required from any easement holder or any other party in interest regarding this application or the work proposed in the application, I have obtained permission from them to apply for this permit and conduct the work proposed. The owner or agent on owners behalf, represents that the information provided inaccurate and grants employees of Mason County access to the above described property and structure for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OFAPROGRESS INSPECTION.INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THEAPPLICATION. X 6Y Date 01-07—/0 Owner/Owners Representative/Contractor (indicate which one) FOR'OFFICIAL USE BEYOND THIS POINT Accepted by: a&jDate DEPARTMENTAL REVIEW APPROVED DENIED NOTES Building Department 'b� i't/� Planning Department Environmental Health Department no 9: H ra I e. j Fire Marshal FEES Building Permit Fee Site Ins ection Plan Review Fee EH Review Fee Plumbinq & Base Fee Planning Review Fee I Mechanical & Base fee Other Wood /Gas/ Pellet Stove Fee State Fee Violation Fee Pre-Paid at Submittal Valuation $ TOTAL FEES