Loading...
HomeMy WebLinkAboutFire Alarm System Confidence Report - FIR Inspections - 3/1/2011 07/22/2011 07 : 17 3GO3080254 TRI TEK 411155 P. 006/006 w Tn-Tek Systems FOR T CITY OF 8527 Kaute Lane NVV n _ Silverdale,WA 98383 I�N6 Voice:(360)373-8373 ire Alarm S e Fax_ (360)308-0254 Ce Report Central Station Account No. Occupied as (major tenant) 110 AddressffZi Zip code Phone N �.— /1 Type of test: Monthly Quarterly Semi-Annual. Annual Acceptance Number of intiating circuits Number of signaling circuits Fire control panel manufacturer F-Arr r- _Model No, Central Station transmitter manufacturer „ � � Model No.—D�� _ Battery voltage = Charge circuit voltage Battery under load Alarms tripped by which initiating circuit Smoke detectors cleaned? FIRE CONTROL PANEL CENTRAL STATION — — TRgNSMrT'TER System operates on AC power Yes Q No Q NA "Alarm Silence"results in tbl.sig, Yes ❑No Yes ❑No O NA Yes ❑No Loss of AC results in trouble signal Yes ❑No ❑NA System operates on battery Yes Q No Yes L]No ❑NA Yes ❑No Ali circuits checked for elect.supv. Yes ❑No ❑NA Test meets manufacturers specs. Yes i l No Yes O No ❑NA Yes Q No All auxiliary equipment operates Yes ❑No Q NA Key to fire control panel available Yes ❑No !]NA Operating instructions posted Yes ❑No El NA Test record posted at control panel Yes ❑No ❑NA �/� Isl Yes Q No Automatic time delay of general alarm —mi: tes Time initiated_ Time received by Central Station ti EQUIPMENTTESTED NO-OF UNITS SATISFACTORY NO.OF UNITS TYPE OF EQUIPMENT TESTED YES NO NA IN BUILDING BeftJ-fornsjChimes,Voice Alarms,Speakers,Water Gongs Visual Alarm Devices Trouble Indicators Heat Detectors Smoke Detectors Smoke Seams Sprinkler Waterflow Alarms Sprinkler Supervisory Switches Manual Pull Stations Ventilation Controls Operate Annunciators Elevator Recall Fire Dampers/Smoke Dampers Phone Jacks Automatic Door Release Other This is to certify that this fire alarm system/Central station transmitter has been properly tasted and inspected for reliability to cover the Items listed in this report is can slstertt �~ with fire alarm maintenance aMndards/manufacturers requirements,and all corrections have been/have not been made. Signature of inspectorKAKEHAMER Date ` Problems Found Corrections Made 04/12/2012 07:40 3603080254 TRI TEK #2000 P. 007/007 r Th Tek,; Stuns .�' OR THE CITY OF J IIZ� 8527 Knute Lane NW. Silverdale,WA 98383 nnr �i Wi(X.'.Q60)373-8373. .�v5 t �. Fax:(36t1)3o8-ozsa Fire Alarm System CO deuce Report Central Station Account No. 75 7 Occupied as (major terfant) 5ATZM 7--- Address 181 -W M—LA Qmt `GS Zip Code 9B529 Phone No. 3(bQ"Z7-5 4e=W11 Type of test: Monthly Quarterly Semi-Annual nnu Acceptance Number of initiating circuits b Number of signaling circuits Z Fire control panel manufacturer 51LEAT A M16"T— Model No_ SZCV-P=- Central Station transmitter manufacturer 1 LEMT b M IGW� Model No. Battery voltage �t�... ,Charge circuit voltage Battery under load Z57 Alarms tripped by which initiating circuit ALA, CENTRAL STATION. Smoke detectors cleaned? FIRE CONTROL PANEL TRANSMITTER System operates on AC powers U f�io ❑NA ❑No "Alarm Silence"results in.tbl.sig. 223 Q No U NA ❑No Loss of AC results in trouble signal s ❑No ❑NA p No System operates on battery s ❑No -a NA ❑No All circuits checked for elec.supv. es ❑No Q NA �s A No Test meets manufacturers specs. ;10'1 s ❑No ❑NA �t'es Q No All auxiliary equipment operates �y�Y ps ❑No ❑NA Key to fire control panel available awl s 0 No Q NA Operating instructions posted :1 ❑No ClNA Test record posted at control panel ao s ❑No ❑NA ees ❑No Automatic time delay of general alarm minutes Time initiated Time received by Cents!Station EQUIPMENT TESTED NO.OF UNITS SATISFACTORY NO,OF UNITS TYPE OF EQUIPMENT TESTED YES j NO I NA IN BUILDING jBells.Horns,Chimes,Voice Alarms,Speakers,Water Gongs Visual Alarm Devices Trouble Indicators Heat Detectors Smoke Detectors Smoke Beams Sprinkler Waterflow Alarms Sprinkler Supervisory Switches Manual Pull Stations Ventilation Controls Operate Annunciators Elevator Recall Fire Dampers/Smoke Dampers Phone Jacks Z Automatic Door Release Other This is to certify that this fire alarm system/central station transmitter has been property tested and inspected for reliability to Cover the items l;°ted in this report is consists with.fire alarm maintenance standards/manufacturer's regWrements,and all corrections have been 1 have not been made. Signature of Inspector Date "'Z"Z t 7 - Problems Found M oc: I M p5LCIT78 M Corrections Made