Loading...
HomeMy WebLinkAboutBLD2024-00855 SFR - BLD - 7/17/2024 Permit No: 4 l ZC�-I - MASON COUNTY RECEIVED COMMUNITY DEVELOPMENT JUL 17 2024 N Permit Assistance Center, Building,Planning BUILDING PERMIT APPLICATION 615 W. Alder Street PROPERTY OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Jack and Alisha Killman NAME: MAILING ADDRESS: 1546 Reservation Rd. MAILING ADDRESS: CITY:Olympia STATE:WA ZIP:98513 CITY: STATE: ZIP: PHONE#1:757-897-2328 PHONE: CELL: PHONE#2:757-897-7044 EMAIL : . EMAIL:LTKILLMAN@HOTMAIL.COM L&I REG# _EXP. PRIMARY CONTACT: OWNER❑ CONTRACTOR ❑ OTHER❑ NAME NICK SANDOVAL EMAIL NICK@WILLIAMS-ARCHITECTURE.COM MAILING ADDRESS PO BOX 102 CITY SHELTON STATE WA ZIp 98584 PHONE 360-426-0511 CELL PARCEL INFORMATION: �0 ^ � " PARCEL NUMBER(12 Digit Number) 42135x-99-eeW ZONING LEGAL DESCRIPTION(Abbreviated)(,'UAA (CIto- 1J r— PLL 20 0 PJA •Z5FIRE DISTRICT SITE ADDRESS TBD VA/ Cl uu- UA-v,E - _ CITY Ir1 DI CTIONSJO SITE ADD S r OLIf' t v + hq v ITTIVE PROJECT WITHIN 300 FT OF SLOPE(S)GREATER THAN 14%: YES[] NO ❑ SNOW LOAD: psf IS PROPERTY WITHIN 200 FT OF THE FOLLOWING: (check all that apply): SALTWATER❑ LAKE ❑ RIVER/CREEK❑ POND ❑ WETLAND ❑ SEASONAL RUNOFF ❑ STREAM ❑ TYPE OF WORK: NEW 0 ADDITION ❑ ALTERATION ❑ REPAIR❑ OTHER ❑ USE OF STRUCTURE(Residence,Garage.commercial Bldg,Etc)RESIDENCE&ATTACHED GARAGE IS USE: PRIMARY 0 SEASONAL❑ NUMBER OF BEDROOMS 1 NUMBER OF BATHROOMS)Q HEATED STRUCTURE? YES(Whole Bldg) ❑ YES(Part[s]of Bldg) ❑r NO ❑ DESCRIBE WORK CONSTRUCT NEW RESIDENCE AND ATTACHED GARAGE ON VACANT LOT S UARE FOOTAGE: (proposed) ST FLOOR 1052 sq.ft. 2ND FLOOR sq.ft. 3RD FLOOR sq.ft. ENCLOSED PATIO 134 SF,' DECK sq. ft. CO:VE�D �CK6 �sq�ft STORAGE ATTACHED SHOP _sq. ft. GARAGE`I sq.ft. Attached 0 Detached❑ CARPORT sq.ft. Attached❑ Detached❑ OME INFORMATION: *4 COPIES OF THE FLOOR PLAN REQUIRED* MAKE MODEL LENGTH WIDTH BEDROOMS BATHS SERIAL NUMBER ENVIRONMENTAL HEALTH: SEWAGE/SEWER SOURCE: SEPTIC SEWER❑ / NEW EXISTING ❑ PLUMBING IN STRUCTURE? YES El NO ❑ If yes, attach completed Water Adequacy Form PERIMETER/FOUNDATION DRAINS PROPOSED? YES 0 NOD EXISTING SQ.FT. EXISTING BEDROOMS 0 PROPOSED BEDROOMS 1 TOTAL BEDROOMS 1 OWNER acknowledges that submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below.I declare that I am the owner and I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project. The owner or legal representative,represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK ON THIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS OF MORE WILL CAUSE THE APPLICATION TO BE EXPIRED. (MASON COUNTY CODE 14.08.42) X -- 7-1 1-24 Signature of AGENT Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT PLANNING DEPARTMENT FIRE MARSHAL PUBLIC HEALTH Permit No: MASON COUNTY COMMUNITY DEVELOPMENT oN C Permit Assistance Center, Building, Planning PLUMBING & MECHANICAL PERMIT APPLICATION OWNER INFORMATION: CONTRACTOR INFORMATION: NAME:Jack and Alisha Killman NAME: MAILING ADDRESS: 1546 Reservation Rd. MAILING ADDRESS: CITY:Olympia STATE:WA ZIP:98513 CITY: STATE: ZIP: V PHONE:757-897-2328 PHONE: CELL: 2°d PHONE:757-897-7044 EMAIL : EMAIL:LTKILLMANQa HOTMAIL.COM L&I REG# EXP. PARCEL INFORMATION: PARCEL NUMBER(12 Digit Number):42135-50-00047 Zoning: LEGAL DESCRIPTION(Abbreviated):CLEAR LAKE TRACTS PCL 20 OF BLA SITE ADDRESS:TBD CITY: DIRECTIONS TO SITE ADDRESS: Take HWY 101 N FROM DT SHELTON. LEFT ON W. CLEAR LAKE DR. SITE IS ON RIGHT TYPE OF JOB: NEW F-7-1 ADD=ALT=REPAIR=OTHER=USE OF BUILDING RESIDENCE LOCATION OF FIXTURES/UNITS—1 sT FLOOR=2ND FLOOR=BASEMENT=GARAGE OTHERO PLUMBING FIXTURES(SHOW NUMBER OF EACH) MECHANICAL UNITS Type of Fixture No.of Fixtures Fees Fuel Type:Electric=PGONatural Gas=Ductless0 Toilets IV 1,7 Type of Unit No. of Units Fees Bathroom Sink Z= Furnace 1 Bath Tubs Heat Pump 1 Showers 1 Spot Vent Fan Water Heater 1 Propane Tank 2 Clothes Washer 1 Gas Outlets Kitchen Sinks 1 Wood/Gas/Pellet Stove hL Dishwasher 1 Kitchen Exhaust Hood 1 Hose bibs 3 Dryer Vent 1 Other Solar Panel Other Base Fee Base Fee TOTAL PLUMBING TOTAL MECHANICAL OWNER acknowledge submission of inaccurate information may result in a stop work order or permit revocation.Acknowledgement of such is by signature below. I declare that I am the owner,owners legal representative,or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties,including any easement holder or parties of interest regarding this project.The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection.This permit/application becomes null&void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OFTHIS PERMIT IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. X 7-11-24 Signature of,Aenceir Date DEPARTMENTAL REVIEW APPROVED DATE DENIED DATE TAGS/NOTES/CONDITIONS BUILDING DEPARTMENT ('AEG 5�-Z 2 PLANNING DEPARTMENT FIRE MARSHAL Rev: 1/27,/2016 AN WAT -Zb2`+ - b MASON COUNTY COMMUNITY DEVELOPMENT RE CENEU Permit Assistance center,Building,Planning JUL 17 2024 415 N 6th Street, Bldg 8, Shelton WA 98584, Shelton: (360)427-9670 ext 400 Belfair: (360)275-4467 ext 400 4• Elma: (360)'@2l_&*AxP"er Street FAX(360)427-7787 Application for Determination of Water Adequacy Instructions 1. Complete Part 1. No determination can be made until Part 1 is fully completed. 2. Complete only the portion of Part 2 applying to the type of water connection utilized. 3. Submit completed application, with any required attachments for review. 4. An approved building site plan must accompany this application. Part 1: Applicant/ Parcel Identification Name on Applicant: Jack and Alisha Killman Date: 7-11-24 Mailing Address: 1546 Reservation Rd.,Olympia,WA 98513 Phone: 757-897-2328 Parcel Number: 42135-50-00047 Type of Water System J Building Reason for Application L� I�J►C�,�Z`-�- ���'�7✓� ❑ Public/Community Water System (2 or more g permit connections) ❑ Division of land: p Individual water source (one connection), #of Parcels? SPL El Well ❑ Boundary line adjustment ❑ Spring/surface water ❑ Other(explain) ❑ Other (explain) ❑ Replacement or Remodel (please indicate name If you have more than one residence connected of water system below if applicable—no to this well, check the Public/Community Water signature required) System box. Part 2: Water Connection Information Complete the section appropriate for the type of water connection being evaluated: Public Water System Name of Water System: Water Facility Inventory (WFI) Number: (write "none" for two-party) ❑ 1 am the manager of this water system. The water system has been approved for services. There are presently connection(s) in use. This will be the connection. ❑ 1 am the manager of this system. This connection will be to upgrade or change the use of an existing connection on this system (i.e.: recreational to full time). Please indicate on the following line the nature of this change: This water system is able and willing to provide water to this (these)connection(s)without exceeding the limits of the water system or any limits set by state and local regulation. Signature of Water System Manager Date 7-11-24 This form may be scanned and available for public view at www.co.mason.wa.us. J: EH Forms Drinking Water Revised 1/25/2018 .,..� A I (/� Name�� 1't1.19Lo1 Kll1$L4^- Parcel# t BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 2 of 2) Based Upon the information you have provided a Stormwater Site Plan IS Required for this development activity. Title 14,Chapter 14.48 of the Mason County Code(MCC)regulates compliance requirements for Stormwater Management in this jurisdiction. A complete copy of the ordinance can be found on the Mason County website: http//www.co.mason.wa—us/code/commissioners/index.htm Please follow the links to"Title 14, Chapter 14.48 Stormwater Management". Regulated activities shall be conducted only after Mason County Public Works approves a stormwater site plan (Mason County Code Title 14 Chapter 14.48 section 14.48.70). You will receive a copy of the Public Works document entitled "Managing Storm Drainage on Small Lots,The Small Parcel Stormwater Site Plan". This document will assist you in preparing the necessary information and plans for Public Works to review and approve. Per Department of Public Works this document will constitute an approved plan if all of the relevant details* are to be installed in their entirety AND no part of the stormwater system adversely affects any septic system(see Environmental Health information below). If an alternative system is to be used a plan will need to be submitted to Public Works for approval. A design by a registered professional may be required for more complex sites. *These details are found in the document Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan on the pages that begin with"Handout" PLEASE INITIAL BELOW TO INDICATE THE STORMWATER MANAGEMENT PLAN FOR THIS SITE A) X The relevant details from Managing Storm Drainage on Small Lots, The Small Parcel Stormwater Site Plan will be installed in their entirety AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. B) An alternative plan and/or professional design will be submitted to the Department of Public Works for approval AND the system will be located as not to adversely affect any septic systems on this,or any other,parcel. If you have further questions pertaining to parcel drainage and stormwater management Mason County's Public Works Department can provide additional instructions,guidance and examples. (Section 14.48.130)contact Public works at: Phone: (360)-427-9670 EXT.450 Mail: P 0 Box 1850, Shelton WA 98584 Physical: 415 N 6th St, Shelton WA 98584 If this development has,or will have,a septic/drainfield system you may need to contact Mason County Division of Environmental Health to ensure that the stormwater system will not adversely affect the septic system of this,or any other,parcel. You may also wish to consult with the septic design professional involved with the project. Mason County Division of Environmental Health can be reached at: Phone: (360)-427-9670 EXT. 352 Mail: P 0 Box 1666, Shelton WA 98584 Physical: 426 W Cedar St, Shelton WA 98584 A condition will be added to the building permit that states,in part,that all conditions the stormwater site plan will be met prior to a request for final inspection of the building permit. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below.I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as ma Pe required. X Owner gen Contractor(circle one)Date:7-1 -24 Page 2 of 2 r Name Jack & Alisha Killman Parcel# 42135-50-00047 BLD# Mason County Department of Community Development Small Parcel Stormwater Management Application/Worksheet (page 1 of 2) Per Mason County Code,Title 14,Chapter 14.48 a stormwater site plan is required whenever a building application is made for residential development,or redevelopment',with more than 2,000 square feet of impervious surface 2. 'Redevelopment means,on an already developed site,the creation or addition of impervious surfaces,structural development including construction,installation or expansion of a building or other structure,and/or replacement of impervious surface that is not part of a routine maintenance activity,and land disturbing activities associated with structural or impervious redevelopment. 2Common impervious surfaces include,but are not limited to,rooftops,walkways,patios,driveways,parking lots or storage areas, concrete or asphalt paving,gravel roads,packed earthen materials,and oiled,macadam or other surfaces which similarly impede the natural infiltration of stormwater.Open,uncovered retention/detention facilities shall not be considered as impervious surfaces. To Calculate Impervious Surfaces Please Complete This Table Surface Type Length X Width = Area *All dimensions in feet Buildings X = X = 3783 Measurements for buildings are taken at the X _ perimeter of the farthest projections (example: eaves/gutters) X = Driveways X = GRAVEL DRIVE X = 4907 Length of drive begins at the right of way CONC APRON X = 736 Parking Areas X - X = Any paved, gravel or packed area per definition above table X = Patios/Walks X = X = Any paved, gravel or packed area per definition above table X = Others X = X = If the total impervious area of the proposed site X = development is greater than 2000 square feet a Small Parcel Stormwater Site Plan is Required Total Impervious Surface Area (sum of all areas) 9426 If the "f'otal Impervious Surface Area is LESS THAN 2000 Square Feet, please read,acknowledge and sign below. Based Upon the information you have provided a Stortnivater Site Plan IS NOT required for this development activity. Owner/Builder/Agent Acknowledges that submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner,owner's legal representative,or the contractor.I further acknowledge that the information provided is accurate and employees of Mason County are granted access to the above- described property for review and inspection as may be required. X wne Agen Contractor(circle one)Date:7-11-24 If the Total Impervious Surface Area is GREATER THAN 2000 Square Feet, please read, acknowledge and sign the information provided on page 2 of 2. Pagel of 2 WILLIAMS ARc.H I TIC cT�RI� 001 W.RAILROAD AVE P.O.BOX 102 SHELTON.WA 98564 PH:(300)426-0511 PROJECT NUMBER 2023028 PROJECT TITLE APPROX ROAD EDGE 20'SIDE SETBACK TYP. '1 7 NEW(2)UV GAL.PROPANE TANKSt106'-0"TO WALL W DUCTLESS FEAT PUMP-VERIFY LOCATION W/004ER FO COVERED SCREENED PORCH I f 40'ACCESS EASEFENT 9 ;� M4 SF SEPTIC TAW,9 _ I I I I EXACT Z LOCATION TO BE COPFIRL-ED / \ i AND I RESERVE IELD j C� \ c I I PER APPROVED /DESIGN 100'WELL RADIUS j _ \ 50'WELL RADIUS W I I 25 FRONT \ �/ F >_ , SETBACK 1 i FROM EASEMENT J .�.:;':. � _ W ( I N / \ 50'MIN.SETBACK O T s FROM OINI NIL + NEW SIDE / j — _ \\ o H 3 Q j SHOP Lu 14a.8F NEW _ — z _ / 4 0 W SF z r.n co�POOCH \ D06tH6 WI91/ It FUTURE � / // = Q ui � '^'0N \ / / RESIDENCE, / Go ,wUNDE PAARATE �j��j v IT EXACT i Q W / F'LACEPIENT /// W J SIZE TO BE \ ' Z w �► ___ ___ / _1 DETERMINED \ \ APPROX.ExiSTMG `DRIVEWAY ACCESS /\) 1 t0 Roao �_ --___ _ =a= 41N7 REGISTERED CLEAR LAKE A0 ITT CT s98'-6G TO EAVE •we rei'-r TO WALL VEL DRIVEWAY- 573.51` sraTl¢NK w�sRlnctor+ NEW GRA � VERIFY EXACT FUTUIF SEWN LINE AND �� T ` 1 REVISIONS CQFICLIFATION TRANSPORT LINE PER SEPTIC DESIGN- ` 'AbwRI VERFY EXACT N V4 WATM(OW LOCATION FUTURE DRIVEWAY -EXACT COPFKaURA.TION / TO BE DETERMINED SEPTIC TAW LOCATION / TO BE COWIRMED SHEET CONTENTS NOTE` SITE PLAN NEW RESIDENCE TO BE CONVERTED TO ADU AT TIME OF FUTURE RESIDENCE PERMRTING PARCEL NO.: 42135-50-00041 SITE ADDRESS: TO BE DETERMINED CLEAR LAKE,LOT 20 DATE 1-8-24 DRAWN BY N.S. CHECKED BY LA.W. SITE PLAN SHEET NUMBER SCALE: I" ■ 30'-0.. NORTH A 1.0 OF 8 F840N1CT10N OR FFAW OF TTESE DRAWINGS WRTIDff WRITTEN P8mmaTaARp1w8PRmT® Les ZINGS ARE GENERAL AND ALL NOTES MAY NOT APPLY TO THIS PROJECT. 23.Install carbon monoxide alarm outside of each separate sleeping area In the immediate vicinity of the bedrooms GS FOR SPECIFIC REQUIREMENTS. and within bedrooms containing a fuel-fired appliance or having an adjacent bathroom with a fuel fired appliance. _ _ tes are general In nature and do not set out all code requirements.it is the responsibility of the 24.All electrical work shall conform to the National Electrical Code,State of Washington Electrical Code and it to be familiar with the requirements of the codes. local codes. ruction to conform to the 2021 International Residential Code(IRC),local codes,state codes and 25.Plumbing and mechanical work(heating)shall conform to national,state and local codes. Washington State Energy Code. igs shall be placed on fill unless specificallysnowed by the architect or atstructural26.All hose bibs shall be freezaproof and have an approved vacuum breaker.l engineer. 27.Install a 6 trill polyethylene vapor barrier on the top of the ground in the crawispace.Provide a code approved - WILL I AM S gs to be minimum 12'below finish grade,per IRC R403.1.4. Class 1 vapor retarder If called for on drawings. able R402.2,concrete strength for general use In footings,foundation walls,basement walls, AR•e H 1 Tf=e-TURF= 28.Caulk,weatherstrip or gasket around all windows,exterior doors,utility penetrations,end.to limit airN- t br or covered stabs is to be 2,500 psi minimum; Infiltration per Washington State Energy Code and IRC.Provide flashing at top per SMACNA Sheet Metal exposed to moderate weathering Is to be 3,000 psi min. Manual. 2 601 W.RAILROAD AVE 48"diameter anchor bolts with 3"x3'hr114"bearing plate washers at 4'-0"on center.No less than 2g Instal!insulation deflectors in attic at soffit wants to assure proper ventilation. P.O.BOX 102 h section of mud sill and within 12"of each mud sill end.Unless shown otherwise on SUuctuml I;i. i SHELTON,WA 98584 30.All windows within a 24"radius of a door,or closer than 18'to the floor,glazing adjacent to stairway landings - -- - I i PH:(380)426-0511 and ramps,and within 36"horizontally of walking surfaces and within 60"from the bottom tread on stairs; thenvise noted,the following grades of framing lumber shall be used: and glazing in wat areas 60"or less from the waters edge shall be safety glazing. - - -- ams shall be No.2 or better Douglas fir-larch �- ams shall be No.1 grade Douglas fir-larch 31,Each bedroom shall have on egress window or door conforming to the current International Residentialin beams shall be combination 20,V4 grade(24f,V8 grade K cantilevered) Cade.Operable windows openings more than 72'above the adjacent grade or surface and are within 24" --- - and roof joist and rafters shall be No.2 grade hem-fir or Douglas fir-larch unless otherwise noted of the finish floor shall be provided with fall prevention devices or opening limiting devices conforming to the In shear walls and studs connected to ho!downs shall be No.2 Douglas fir-larch IRC. - PROJECT NUMBER shall be stud grade or No.2 hem-fir,Douglas fir-larch,or SPF 32.All windows shall have glazing as shown on the window schedule;see - _ - '' 2023026 fherwise shown,headers over exterior openings and over openings in Interior bearing walls shall window schedule for further information prior to ordering windows. 3.2 or better Douglas fir-larch. PRAT T E 33.Heat pumps and Tumacns,and their Installation,shall conform to the Mechanical Code and the Washington connectors shown on the drawings shall be Simpson Strong4le Connectors,unless otherwise State Energy Code.Provide high efficiency heat pump If called for In the drawings or on the window :e only approved connectors for treated materials. schedule. arameters 34.Provide dryer went to exterior per code. is: Earthquake Zone = D2 35.Owner or contractor shall provide manufacturer,model number and sizes of heaters,furnaces and beat = 25 PSF Exposure Category= B = 40 PSF Wind Speed 110 MPH(ASCE 7-10) pump units along with efficiency rating(HSPF)to the Building Department. 60 PSF Soiling Bearing Capacity on firm, 36.Owner or contractor shall supply bathroom,utility and kitchen fan sizes,manufacturer and model number ids: undisturbed soil - 1,500 PSF to the Building Department. = 15 PSF Concrete Design = 2,500 PSI12 PSF 37.Whole house ventilation fan shall be controlled by a timer switch or dehumidifier control with a manual rF 10 PSF •Notify Architect if actual site conditions override switch unless otherwise shown on drawings. _ \ 12 PSF vary from the conditions listed here. 38.All exhaust ducts shall conform to the Energy Code for diameter,lenq_M of run and number of elbows. Its,beams,Joists,exterior stair framing and all railing members shall be of approved naturally insulate to a minimum of RE. Ipecles or pressure preservative treated wood.Contractor to verify that the material or finish on 39.Where shown on drawings,provide tested outdoor air inlets of minimum of 4 square inch in each living area, _ '~ - - "� ancilor connectors are compatible with treated wood for decks,treated sill plates,eta " ' P P sleeping area,cooking area and eating area.Inlets may be integrated with window Names or through-wall god and oriented stand board(OSB)and application to be in accordance with American Plywood vents.Indicated on plan as Cd. ion standards and the current International Residential Code. 40.The architect is not responsible for site conditions.This includes soil bearing capacities,slopes,surface or Ind,full depth blocking at all bearing points at joists and rafters un:ass manufacturer specifies subsurface water condtdom or any other subsurface conditions.Notify architect of any deficiencies e. encountered. -` iolid fireblocking around tubs and showers. 41.Provide an approved duct system and whole house air!eakage test as required by the Washington Ste'» Energy Code. hown otherwise,provide a 30"x18"crawlspace access in location indicated or"required by code. 42 Provide the followingin order to conform to the Energy Credit re uirements of the Washington I -i rgy q rgton State Energy - !2"x30"attic access(N applicable)in location indicated or as required by code. Code. 1 height shall be T-0"high.Handrail height shall be 34"-38".Handrail required on at!east one ENERGY CREDITS:1052 SF PROPOSED<1500 SF,5 CREDITS REQ'D i f i stairs with three or more risers.Guardrails required on all landings and decks mom that 30" HEATING OPTION 4:3 CREDITS a-. •. j . % \/ Z or or grade below.Picket spacing on guardrails shall not allow a 4"sphere to pass. FOR HEATING SYSTEM USING A HEAT%MAP THAT MEETS FEDERAL STANDARDS I i -._ - .' r height shall be maximum 7.U4".Treads shall be minimum 10'.Stairway width shall be FOR THE EQUIPMENT LISTED IN TABLE CM3.32(2)OR C403.S.2(9)minimum Ill- ,ids illumination for all stairs and landings.Minimum required head height at stairways is 6'-8". OR Z AIR TO WATER HEAT PUMP UNITS THAT ARE CONFIGURED TO PROVIDE BOTH x = s,woodstoves and fireplaces,and their Installation,shall cortorm to the current International HEATING AND COOLING AND ARE RATED 0M ACCORDANCE WITH AHRI 5501590 UU0 H lal Code.Provide seismic bracing for chimneys per code.Owner shall provide contractor with IL ,Cc at and woadstove specifications and setbacks. 1.1 EFFICIENT BUILDING ENVELOPE:0-5 Q Initial sheet metal flashing as required for a water tight job including at all window and exterior PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R4021.3 WITH THE FOLLOWING = ds.Conform to details In the SMACNA Sheet Metal Manual. MODIFICATIONS: r4 2-6• B 2-6• M G A water P&T valve to exterior and provide sheet metal pan as required by code. VERTICAL FENESTRATION U=022 li FI. Z Z H 3.6 HIGH EFFICIENCY HVAC EQUIPMENT:IA ? Q W 0 volt smoke detector with battery backup in each sleeping room,each corridor giving access to _ W = rooms,and one on each level not containing sleeping rooms.Interconnect all smoke detectors. AIR-SOURCE CENTRALLY DUCTED HEAT PIMP WTM YNM1M HSPF 2 OF 8.4/i1SPF OF 11.0). DB GUTTER DRAINS TO V Z H A CENTRALLY DUCTED AIR SOURCE COLD CLIMATE VARIABLE CAPACITY HEAT PUMP 1 in/ abbreviations (CC VCHP)FOUND ON THE KEEP CC VCHP QUALIFIED PRODUCT LIST WITH A I 2 LOOS, W 4i LL MINIMUM OF 9 HSPF 2(10 HSPF)MAY BE USED TO SATISFY 7MS REQUIREMENT. 1[I Anchor Bolt FDN Foundation R Radius IN AREAS WHERE THE WINTER DESIGN TEMPERATURE AS SPECIFIED IN APPENDIX OS. M RC IS 23-F OR BELOW,AN AIR SOURCE CENTRALLY DUCTED HEAT PUMP SHALL BE W Air CondRioning FF Finished Floor R&S Rod&Shalt DB' i 1 A COLD CLIMATE VARIABLE CAPACITY NEAT PIMP AS L16T ED ON THE NEEP QUALIFIED PRODIAA.T LIBr.AcousticalFIN Finish,Flnished REF Refrigarato;Additional FfXT Fixture REINF Reinforcement, TD QUALFY TO CLAIM THIS CREDIT,T E BUILDM PEHfT DRAWINGS SHALL SPECIFY GutfEyt __" WAdjust,Adjustable FIR Floor Reinforce THE OPTION BEING SELECTED AND SHALL SPECIFY THE HEATSIG EQUIPMENT TYPE D,g, TO LOWEIc ROOF P!ZT AND THE MINMUM EQUIPMENT EFFICIENCY. --- Above Finished Floor FLUOR Fluorescent REQ Require,Requlrad tFND Foundation RM Room LAR TUBE AS SELECTED Br OWNER 5.3 EFFICIENT WATER HEATING:0.5 ------- 3)LOCATIONS Aluminum FT Foot,Feet RO Rough Opening ?�- A TERED Approximate FTG Footing WATER HEATING SYSTEM SHALL INCLUDE THE FOLLOWING: Y-O" TECTArchitect,Architectural FURN Furnace SD Smoke Detector ENERGY STAR RATED GAS OR PROPANE WATER HEATER WITH A MINIMUM UEF OF 040 ON. I LOWER A W-WED ROOF EAvE BELOWAsphalt SECT Section TO QUALIFY TO CLAIM THIS CREDIT.THE BUILDING PERMIT DRAWINGS SHALL SPECIFY L Wu 12.r'ETAL ROOFING PANELS Average GALV Galvanized SF Square Foot THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EQUIPMENT i I, oSER ELEv. aYt�Erlt PER t1FR GL Glass SHT Sheet TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY. SEE ELEV, S-T-ATBedroomGL SLK Glass Block SHTG Sheathing - - - 642SieT Between GYP BD Gypsum Board SHWR Shower _ Building GINS Gypsum Wallboard SIM Similar ^� I Blocking STD Standard `� REVISIONS Beam HB Hose Bibb STOR Storage _-- I I I ) r-O• Bearing HDR Header STRUCT Structural Basement HOR Hanger HORIZ Horizontal T&G Tongue&Groove CS.BELOW Cabinet TEMP Temporary,Tempered I I I I + Cubic Feet IN Inch N Television I Ceiling INSUL Insulation TYP Typical Clear INT Interior - D 6¢ I I I'-0• Carbon Monoxide Detector I I I OH. SHEET CONTENTS Cleanout J-BOX Junction Box ¢ I UPPER WALL ABOVE ROOF e2y¢ a4- GENERAL NOTES Column JST Joist UNFIN Unfinished GUTTER DRAINSI romposklon LION Unless Otherwise Noted Symbols TO LOWER ROOF I' I III I GUTTER DRAINS TO LOWER ROOF ROOF PLAN Concrete LAM Laminate,Laminated UNO Unless Noted Otherwise -2 L005. POST BELOW Connection LAV Lavatory V volt ivr VENTED WINDOWS � FLOOR OUTLET D ROOF EAVE BELOW I Continuous,Continue LIN Linen VAC Vacuum TAL lit F!NG PANELS :ssement LL Live Load VERT Vertical - -----{ WINDOW SIZE IN FEET AND INCHES I:L F WATERPROOF ELEC.OUTLET PER rs1¢-SEE ELEV. Cubic Fcet 30 50- (3'-0'WIDE x S-0"HIGH) CEILING MOUNTED LIGHT FIXTURE I ( I r2'.!'12 Cubic Yard MAX Maximum WIO Without S.H. SINGLE HUNGIVERTICAL SLIDING WINDOW � WALL MOUNTED LIGHT FIXTURE I i I 2 2 MIN Minumin WH Water Heater H.S. HORIZONTAL SLIDING WINDOW - Double MISC Miscellaneous WIN Window RECESSED CAN LIGHT FUTURE D.H. DOUBLE HUNG WINDOW ® E i 6:¢ I I E DATE Demolition WP Waterproof,Weatherproof ® CEILING MOUNTED FAN Department NATL Natural CSMNT. CASEMENT WINDOW ® �-8-24 Detail YD Yard THROUGH WALL FAN I � I ROOF ON.TYP. Double Hun OBSC Obscure AWN. AWNING WINDOW h�oocc CEILING MOUNTED FAN AND LIGHT ,;j, I DRAWN BY g 7tt D.S.D BELOW 9 I LIFE aF WALL FJELOW Diagonal OC On Center B.V. BOTTOM VENT-FIXED TOP PANE WALL SWITCH D.S. i0 I ROOF CRICKET N.S. Diameter OHD Overhead Door WIHORIZONTAL SLIDER AT BOTTOM I I I ) I I I I I Dlmenslon OPG Opening FXD. FOIEDIPICTURE WINDOW .-& 34MAY WALL SWITCH SEE ELEv. CHECKED BY Dead Load OPP O site -4 4-WAY WALL SWITCH !- ----- -T I I I I LINE OF WALL BELOW L.A.LU, Down PPo DOOR SIZE IN FEET AND INCHES III �.. ;i TELEPHONE OUTLET .. PREFo12-ED GUTTERS SHEET NUMBER Downspout P.LAM Plastic Laminate (Y4"WIDE) TELEVISK)WCABLE OUTLET i 4 MATCHNG DOWNSPOUTS Drawing PERP Perpendicular 26 PL Plate oil CENTRAL VACUUM OUTLET Each PLYWD Plywood DUPLEX 110V OUTLET _r D9.TO LOWER ROOF Electrical PREFAB Prefabricated -+ THERMOSTAT A 1■ Elevation POUR Power #7 QUAD.OUTLET 4V $ 220V OUTLET SMOKE DETECTOR DS- EquaI 3X HALF SWIT HC ED OUTLET CARBON MONOXIDE DETECTOR A Ox ROOF PLAN OF Equipment SPECIAL HARDWIRED CONNECTION NOTE` UNOR OM.TTP. 1 FOR PP40,OOEE iCR1CKET�W/�25-�QoP LINO. SOALE= �i" ' I'-0" PLAN NORTH LT OR D RgRNGS WITHOUT WRITTEN Each Way Existing UNDERLAI'MENT PER r-M NORTH ulew59pl10Ft!IEµCHW61=R"TED h 0:. ADJUST SLAB HEk5WT THIS AREA �. NEW 6.6 POST ELEVATED TYP BA6E !n B A9 REQ'D.FOR ROLL-M SHOWER B'-D -10• (2)LOOS. w 4 TILE PNISH SCREENE PATIO , I W ILL I AM S ARcHITf=cTUR� Y 4•C4NC.SLAB �..... h'•I•r:R�. FOOTING PER STRUC. 601 W.RAILROAD AVE 4•CONC.5LABe I AWAY FIB71'1 BLDG� �.. P.O.BOX 102 -SLOPE k.•PER I.T. :� , Y FRA.1 pLp� SHELTON,WA 98584 — — — PH:(360)426-0511 EL. mom' TOP cF CONC.WALL � - — — — — — � � I I PROJECT NUMBER 2023028 - - - - - - - - r PROJECT TITLE I I I I Id RESIDENCE I.. II I I I 0 EL O'w' I k .•Ca+c."AD —_ J I I Z L8 :RETE(WA:7 BEOWDPFTER CFD)--- f I J zo fill SHOPLOW POINT OF SLAB - . .- 'IL/ IL {U)`4x CRlO.SLAB , `.. _ FoorNG PER 9TRUC =FL`T CQJG STET?WALL / . 4'CONC.SLA5F/AY FFIdPE�T1 MDO. x _ o --6•x 17•COW. i k.ca'r--sn"WAu I— W P6t 6 T1fP.0 erloP UNG. � ' .. . V Wks"POINT OF SLAB 3 /� _I I 6•x ST CCNT.FTC.16'GOIJC.STEH WALL Q euwr Olb 1R AT DOOR AS IVEGD. PER STq G.TYP. TO MATCH 5F10P eLA6 I - I I ?. � V rr RIF) SLOPE TO MATCH GARAGE•CsARAGE 40 T REGISTERED _ SEE ELEv ARC IT"T II II. II GARAGE C - - SPATE OF WASNINGTON II II kl � _ ~ REVISIONS I I L 4'GQW_ eLohe VN'PER FT. 6 BLOCK OUT FOR&#M W DOORS TIP I TO111114W DOOFS 19 I1 lI + ji — —— SHEET CONTENTS z, I I ARGI-IITECTURAL FOUNDATION PLAN EL.-075' � I LOW POINT OF SLAB - DATE 4•C W-AFMN 1-6-24 -eLOPE w mm FL.. - DRAWN BY AWAY PNIO'1 BLOC /. CHECXED BY B A i LAW. SHEET NUMBER ARCHITECTURAL V A2.0 2s'-61*•SHOP 34'-b107 � FOUNDATION PLAN Q ofRSWMTKM OR 8 _ e4'm• SCALE: 114" - V-0" PLAN NORTH DRAWW.S WRHDUTWPoTrEN NORTH PBUMOFTHENERWIRMI _ _ _ e — NEW bxi POST PER 811WUC A 2S'-6 1/2'SHOP 36'-S N 9 •'-6 V4' 3'-3 3/4' 10'-6' T'-7 3/4• '-2 V4 EXTERIOR �—2r&U44LL XTERIOR NDW'!< Y-Y 4'-7 9/4• 'i V4 •-8 3/4� � 4'-X•� - 4'-A• � � I'-X FEAT MER E POD®4.4 NON-STRUC.VERTICALS POSTS TYP. CONFIRM EXACT LOGITION WITH OUTER RESTNG CN PT AX6 SILL j eW LOCATIONS - 4'-S 4'-11/2' 1 " � WILLIAMS SCREED PATIO I —STOPPED-IN SCIIENS DETLLEEN POSTS 1 TYP.3 SIDES ARCH ITI`GTU R7 - 1 I ROOF ABV.TYP. '' — — — �. _ H01W.RAILROADAVE 2 • 2t 2@ s@ (3) I I P P.O.BOX 702 SHELTON,WA 98W LIVM SPACE (2) 120 GAL.'1 - - HB. PH:(360)426-0511 PROPNE raacs 7 I _ 9 CONFIRM LOCATION OUTER ♦ I + .. BE AM, TIOlC. - I Y TILE Tilli .:.- '� I CLOSET _ I WALK_ l1T OWSbS,a1S7SE1S T MBE yX, . .. I PROJECT NUMBER I I IV Air 1 3--1- BEDROOM I 2023028 vAia.tED - o PROJECT TITLE Nor S s�Rac J ;BATH r.m• 6 n ' WW S*Oom.TTP: ^ 9'-O•H.FLAT 28 I n T LET I •�SS71" OPEN PKT 3S•VANITY F1CT El LR N O ® 214 UALLS 2xb WALLS S - - TYP. MIT. 1 (2)26 692 BARN DRS. ' S I 21!CL6.JI21SM.241 OL.... / STONE OR CULT.STONE I ADv TCRAT SFL : I I 1' N WALL FRAMING PLAN DETAIL AT SHOP -NORTH VEFEEROPTON2 I �PPERG°B6"T,P. - r ®® �� 4 UV GOIJG CAP-SEE ELEV. ,_ �� � .: -. .` � � LOWER CADS.- I- 3CALE: 3" s P-9)" r PER DETAIL 2/A3.1RA#r I �NDOD DLI X. y. G 0 FAN3 1. LIVING G s .� sac l I -- --- " FA Y p "I. I L -------------- i KITCHEN I . I VAULTED — i �- WW TE HOOgJpS, 9'-O•FL CLG. l Q 2.6 WALL A I-0' I I I 4"COIiG.SLAB-FLAT P. FULL HT.STONE _ cPOWER WATER t SELLER 1 FLAT OR CULT.STONE VENEER OPTION I SLIM OCHIMM JONEs TYP. FOR RV HOOIQIPB •CONDITIONED SPACE - F{ a Q LIVING SPADE WE F1EV. ALCM THIS WIALA_ 1 CLEAR 3'_0• U2• \�LINE OF CLG.BREAK ABV. .AS DtlIECTED BY OYbSi1S ►-VISA-Vl'LVL F�Si 1_ REII. GABS. SPACE Fi¢AI DOWN 5 PEW 67RIC. P — ). •.. .. .. I 2�OR:. 7�big BAIBI i 9'-V"W.SOFFIT AT CABS.4 FP.KNIM BRACE S ELECTRIC wOw1s I bb WALL " PER 8710lC. 1 - AICJED 3@ bQ OPG. - FIREPLACE ml q 2 LOCS. 6'STEYI WALL DELOW i` I. - STACK PANTRY SABB- DR ��// Z 1 , WSD G. `� uv LITE - i O LOVER ROOF ABV. F - 2 20'D.GAB.Q -3'-I I/3• 4'-O" - 3'-T" I'-X•' 3'-3 VI I SEE ELEV. a z L_ ( 5'-b•CLG wr. . n••SOLAR T" CAD 5S K CABS. J 1/l• _ l3 LOCATIONS) u I D i 9 OP $ , I I UFv.ER r.1ea: O O ^O�' S a.O y 3 1 ,a v FLEX x J 1112 21�D. 9 w CL, POWDER R0�01'7. f".LEA -j FLAT DETAIL 2/A2A7 FLAT 9'H.GL6 T{AT 9'R 0.G 2x6 WALL T.WALL NNL TYP. Q Q O _ I 3@ I. -3Q VAULTED.. I •1�,s.EXT.WALLS ONLY WALL PKT. - I.PKT. - bxb POST PER STRJC. Q J W RIGID NSUL..RE IRENCE OILY W-2 - - �. I WRAP W/CEDAR 1. !F W W 31 POST 1N L PER 6T1R(C.,: AB. — - AND PROVIDE CAP. i A I Z*WALLS PER 9TRUC. LToi I PER DETAIL 3/A3ID V Z LL 0ID0'FF ..T7P..'Exr.WALLS I �� W Q W .6'AIWA!$DOOIM.ADOVE ., "� FAN 2x6 WALL W/RKaID INSUL — W WIT L . - .. - NO STEP EL.000' r w GAFACaf _ r -- T---- Ix — --- -- , HK.N POINT OF SLAB 3 3: // W r'---+- rYr SLAB: — '1 ON-DEMAND PROPANE HILL.HTR - J ROOF ABOVE 1Y \� J 7ri XMLL 1... I. I AT DOOR AS tRG'D I WATER SOFTENER Z � V LIE OF LOWER ROOF I I 1 I P 1 I + 1.. PER OUTER IAS K i097RA' ERED TECTWALL FRAMING PLAN DETAIL AT GARAGE -WEST a I I 1 rKALE: 3" P-0I, ' I i. GARAGE � STAINWT N 1 �. wcoNDlnaED I o 2.6�'L 4'CONG SLAB REVISIONS $ _ -SLOPE V..PER FT. C C 9 1 I TOWARD DOORS 6TORAf4[ e1 9 v 2ri Exr.WALL 7 TTT..'SFIOP w+v. IVNG SPACE �. _ ...1. 1° .. I.. .-. r----------------- --, F 1 1. I . 1 ccwrtlaED WALL SET IR111 LJ. r+4Ea o _ - Q,� µ,me -.. ;�. µ.me. . ISM WNl eswl - OF CONC.STIS'I WALL _ — DOOR: — DOOR � t- _ .I- - .i $ FLOOR PSHEET LAN S — — — — — —i. 1 : I DETAILS }' — 1 iL-019' LOW POINT CIF GLASS - 1 FLOOR AREA TABLE FLOORS Fl-OOR AREA II T.R-5 EXTERIOR&DN PER ELEVATION TOTALLM SPACE 10 . . - — — DOOR _ J DATE -CONTHICUS AT. •E Mm GARAGE 5w . LIVN6 SPACE SHOP 1486 _ -�� an I.4 _ L 4•CON,.APRON DRAW BY � 24 -SLOPE i4"PER FT. ®. N N.S. 61EATHlYa PER SECTION .. AWAY FROM DOORS - FLOOR PLAN CHECKED BY FAN SCHEDULE 1 EXTERIOR � 1 - � � L.A.W. ' I SO POWDER ROOF SCALE: 14" • I'-0" SHEET NUMBER "°'R'°GE 2 Be MUD Room ROOF ALIGN CARA&E WALL FRN W/ 3 We RANGE HOOD ROOF I__.. - __-_ - PLAN NORTH A 2.1 calc GTem wAUEELow 4 10m DAtH WALL NORTH II 4'•1 V2• 9 IECIa TOILET WALL e,_b• 13'_0" V-e IR• V'-2 3/4• O'-1 V4• RUTEI®NOTE: ALL VALUES REPIffSENT 'IITTENT 2S'i V2•GNOP 74'-4•GARAGE WALL FRAMING PLAN DETAIL AT SHOP -EAST -11 1ST RATES-SEE!RC FOR CONTINUOUS RATES O 5' 1O' 2O' OF 8 1EAT PUMP SYSTEM 15 TO PROVIDE WFIOLE HOUSE 93'-I0 VY RBMOd1CTIDN Eli RF1SE OF THESE EXCHANGE RECi IREMENT9 PER WSEC DRAWINGS WUTHOUT WRITTEN PBHSM0FIIEAi IlW6PW0T®. EEC ROOF PLAN FOR OH DF4 I STRUCTURE FOR VARIATION•TPLM 4 RAVER U°. WILLIAMS ,. ARcHITr-_cTURe Q 601 W.RAILROAD AVE i r P.O.BOX 102 SHELTON,WA 98584 -- PH:(360)426-0511 pa 000III- ARCH.COMP.SHINGLES OVER WDERLAYMENT PER rm 514.10 CEDAR RAKE TYP.-SEE DETAIL I/A3ID INSUL•COND.SPACE HARDIE SHINGLE SIDING W/W EXPOSURE PROJECT NUMBER INS•W"OL. ITIGNED SPACE CEDAR TRIM BAND ttP.-SEE DETAIL I/A3.1 025 TRUSS OR RAFTER 2m23TLE ❑❑❑ ❑ ❑❑ ❑❑❑ GUTTER DRAINS TO LOVER ROOF 51er1 VE BARRIER _ PROJECT TITLE PREFORMED METAL GUTTERS�MATCHING DOUNSPOUTS -SEE STRUC. PANEL 5IDII W/2.CEDAR BATTENS•12"O.G. _E ELEV. ❑❑❑❑❑❑ ❑❑ ❑❑❑ 5/4 x 10 CEDAR FASCIA P.-SEE DETAIL 2/A30 5/4 z b CEDAR WINDOW I DOOR TRIM ttP. 5/4x4 CEDAR COftdER TRIM TTP. P.T. PED W DA bxb PT POST PER STRUG. WRA❑❑❑❑❑❑❑ P /CEDAR TRIM -SEE DETAIL DA 4'CONC.UlALK W THICKENED EDGE WE DETAIL °`Iw UPPER GLASS PANELS O'w°UPPER GLPANELS �IIV�IPzPCE1¢�GLA�se' DOOR •ALE: 11/2" . 1'-0" 34•OR TYP. FIP.9H4UGl.E ROOFMCP '. ERLAYMENT PER FF- SEE ROOF ROOF SHEATHRYP R VARIATION _ RESIDENCE ELEVATION 12 .. ..R-49 BATT Z :CIICf.ED SPACES D&. 1�------ ___-- _------- --------- --ate —�' -- ---_ CON CONY.OVER TOPE rQ EDGE NAILING FOUNDATION BELOW GRADE ttP. 45.TRUSSES•24.O.C. STONE OR CULT.STONE VENEER OPTION 2 UV CON-CON-CAP W/lxb TAILS TYP. ROOF FRNtiR•ICa PLAN PER DETAIL 2/A31 SLAB SLOPES AS REO'D RILL DEPTH TO MATCH SHOP A GAR"'LEVEL SOUTH ELEVATION J TED BLOCKING PANEL SCALE: 114" 1'-0" i O H-I CLIP PER STFI IH PRE-FINISHED 1ETAL GUTTER O U. d h a c 3 CEDAR FASCIA O O PER ELEV. Z Q J MCNAL VENTED SOFFIT PER OUNER LINE OF CRICKET BEYOND W = ' DOUBLELu OL NAILER LAYER -SEE SOUTH ELEVATION 4 ROOF PLAN 2)10p1B 16dP Z. W EXTERIOR SIDING PER ELEV. R-5 CONT,RIGID INSULATION (A be J •CONDITIONED SPACES W W/TAPED JOINTS PER MFR. TEND 4 EDGE NAIL WALL 5HEATI4ING J UP TO EAVE LEE OF WLL EEYOND WM 1 INSULATION PER SECTION _ -"-- - - -- _ V 'IING L�•!OF ROOF BEYOND — _ - GY.B/INTERIOR FINISH PER OUNER - __ _ �r _ LW OF ROOF I WALL BEYOND ___ _ _ __ -� _ __ - -- -,. 5/4xS CEDAR FASCIA A RAKE•CURVED ROOF EVE DETAIL Q CONDITIONED SPACES GUTTER DRAMS TO ROOF A R ITECI- — •�� REGISIT,, __ — _ — _ :ALE: I° , V-0° --- _ - -_ _. ARCHED ROOF __ _ W/12"METAL ROOFING PANELS u aum ti LRff OF 0.Ca BEYOND STATE OF WASRNOfOM HDR BEYOND PER 5TRUC. REVISIONS 1 7.CEDAR TRIM 0111 PER STRUG. W/10'CANT. 4Q 4Q 3R� yl 1111 1 11 11 1 It III I I 1 11 1 1 2.9 CEDAR TRIM EXP.4z6 DOOR HDR SHEEP CONTENTS CC66 pill BUILDING ELEVATIONS STOPPED-IN SCREENS DETAILS 5 F)m. F7m. F)m. DETIIEEN 66-1.CEDAR SOFFIT 39L 5 @ ttP 3 SIDEgVERTS. PT POST PER STR1C. DIE CEDAR TRIM OCf'M FXD. C.81'M. 1. aFRAP PT4xb SILL b,CEDAR TRIM W/CEDAR WRAP D Pf bxb POSTS b CEDAR TRIM LL PER STRUC. �I 4•C.ONO.SLAB W/CEDAR WRAP DATE a$ I I •@1TRYPORCH oA I I ------------J 1-8-24 =m II n II Da ----------- -------------------- DRAWN BY I•I I COW—Fra-COL. ------------------------ - ------------—�------------ ------------------—� N.S. SASE PER STRUC.BEYOND I I°I i I -am MR PLAN iTONE OR CULT.sroNE VENEER OPTION I CHECKED BY ADE L A.W. I I a SHEET NUMBER WEST ELEVATION A 3.0 SCALE: 1j4" - P-O" :OVERED PORCH DETAIL @ TRUSSES OF RBRODWTION OR RE-USE OF THIME GALE: 1" = I'-0" DRAWINGS WITHOUT WRITTEN PH+11SSg110F THE A4OlIFL15 PPDIBI6). ORVED ROOF III/IV METAL ROCFNG PANELS /---F—IA I—•CUZVED RNA GUTTER DRAINS TO L04ER ROOF -2 LOCg' WI L L I A M S ARcH ITE cTJR-E RIGID INWL.OR RURRMG•50ME LOCATIONS - . WALL SHEATHRNG 801 W RAILROAD AVE -SEE STRUC. _ -- P.O.BOX 102 WATER-RE515TIVE BARRIER SHELTON,WA 98584 SLIT 4 LAP OVER ZEE FLA5141NG PH:(380)426-0511 SIDNNG PER ELEVATION ZEE FLASHING I 2x4 CEDAR TRIM W/IV'CANT PROJECT NUMBER 2 x S CEDAR TRIM Q 2023025 ❑ O❑� O❑ -- - --- -_ PROJECT TITLE TW CAULK - --— I-IARDIE PANEL SIDING W/2.CEDAR BATTENS �ATTENS BEYOND _. PRO. L FRAMNG UM BAND DETAIL �� ALE: r z., , ,,_m„ MPT H :'O�O� UO O �o a :.... .._' O❑ ❑O ❑ it -------- y Z 1� � Q Dd L------ --------------- ---II-------_------ ---_�- --_--------------- -�-_.. _ - Dd Dd Dd Dd c 9/4.CEDAR MLL TRIM AS IE010 J 8TQ!OR CULT,5TONE VENEER OPTION 1 WEATHER RE5I5TANT BARRIER EAST ELEVATION 9LIT-LAP OVER ZEE FLASHING 0 HARDIE BIDI PER ELEVATION SCALE: I-m" NG FLA5141NG T 0 i S LL 'w d v/ Q 0 = 3 o Q F FIM-CAST STONE CAP 4t Lu W CULTURED STONE VENEER 0 Z y WALL SHEATHING-SEE STRUC_ zLu Q WALL FRAMNG y 5 uj v •F- W Q 3 GUTTER DRAINS-2 LOCS. Z ' V ao97 ""STERED ZE-CAST CONIC. CAP @ CULTURED STONE VENEER All ITECT ALE: I'i2" = I'-0" S1A.OF"..'.T.. WALL FRAMING PER SECTION 9HEATHMG PER SECTION REVISIONS _ER AS SELECTED BY OVER — SEE ELEV. — FLASHMG AS REO'D _ IS"MTL.IOOOFMG OVER _ U.DERLAYHENT PER MFR. 3111, ROOFING MEMBRANE D.S. F)m RICO 'j ii. T AFTERS PER STFd1C. _________ _________ 5/4x CEDAR FASCIA 1 RAKE � I I � '. i' SHEE CONTENTS •SCREENED PORCH BUILDING ELEVATION CIA PER ELEVATION I g KNEE BRACE DETAILS PER 5TIC 242 5C (2) ' Fm' i TAG CEDAR SOFFIT iE OR I BEAM PER STR11C. AT WALL PER 5TRUC. I I I I I RESIDENCE ELEVATION.000' DATE BRACE PER STRUC. ,�...:.�:'.-. SIDING BEYOND I. L----------------- 1-8-24 Dd_______________________ DRAWN BY ��-------------------------- ----------�___--— - -----___-__ --__-------_ N.S. HEAT FV'IP (77 120 GAL.PROPAIE TANKS-CONFIRM LOCATION W/OU.ER CHECKED BY CONFIRM EXACT LOCATION 2.6 CEDAR TRIM BAND WE DETAIL 1/A3,1 Sm L.A.W. UND011 RO.HEkSHTS AIM TO BE FRAI-ED 50 NORTH ELEVATION SHEET NUMBER 3 3/4• THAT UNDOW FRAMES AND DOOR FRAMES AND r THEIR CA5INGS ALIGN HORIZONTALLY SGALE� I'<" = 1'-0" VENEER/CON-.CAP PER A 3.1 DETAIL 2/A3.1 SIM 4EE CE DETAIL OF a ALE: 1" m" REPROOL0011Dfl�OFTHEM DRAWNGS WRHM WRITTEN P5a1SS101N CF LIE/N7TW S PIIMM WINDOWS N FOREG Um R7 AT EAST WALL LINEOF CLG..KITCHEN BEYOND LINE OF ROOF N FOREGR'JIMJ AT EAST WALL CURvED ROOF BEYOND 1,4 RAFTERB.24'O.C.PER 5TRJC, FOF41 CURVE,SUPPORTED BY KNEE BRACES �T PER STRJC W ILL I AM S VENTED RIDGE CAP PROVIDES 135 90.RN.FREE AIR MIN.TYP. PW-ENG I40OF SCISSOR TRJSWS.24'OC. Al GTU RE R-49 BATT INSULATION.FW&-EWY TRJOSES OVER CONDITIONED SPACES TYP. FULL-- -- - — - - - _ _ 601 W.RAILROAD AVE -- -- --- -- - — IS•ROOF SHTG.PER STRJC.NAILED UUSd.b'/O'OC.TYP..ROOF FRAMING P.O.BOX 102 BOARD.24°F SHELT GY ON,WA 9P1564 T'9UM RAMWG OLLNER OPTION:US WOOD T46 OVER FRAMING, PH:(360)426-0.511 - -- Q INSULATION DEFLECTOR-MAINTAIN I•AIR SPACE MINII-LLPT ABOVE INSULATION PROVIDE MN.5.1 SO,RN.FREE AIR/LIK FT..VENTED BLOCKW, -- - SKIP60N M5 CLIP EA RAFTER PER STRUC. Ix TK.CEDAR SOFFIT 2.6 RAFTERS.24.OC.PER 9TRIJC. PROJECT NUMBER ---_ _ 5/4x CEDAR RAKE N FASCIA PER ELEV.TYP. 2023020 -- _ — —— —— ———— `— PROJECT TITLE RIDGE BEN PER srwBEAM Z. _J 2 12 4.4 POST PER STRI.C. SIDING PER ELEV.OVER WATER-WSISTIVE BARRIER St L PER STRJC. I'R-5 CCNT.EXTERIOR WSUL.TYP. OPTIONAL R-48 BATT NSULATION TYPE'X'GYP DD G GARAGE I I I I I I I I _ - • ARAC.E 4 SHOP CLG.N UL1LL6 GOM'ION UV IE6. I L_---'�L_--_---I L---J I R :"COX PLYWTJ.SHTG.OR T/Ib•0515 PER STRJC..WALL FRAMING HDR PER STR1C. SHEATHING N RIGID IrNsllL TH SIDE 071 FLEX I I I I NO! BEDROOM 3 R-21 BATT NSULATION.EXT.LLWLL FRN'IWG OPTIONAL I!1'GWB rLLA V W"�' I GARAGE I I I I I IS _ 2X6 WALL FRAMNG.K'OC.TYP. OPTIONAL CLG.INSULATION I i I I U}'GYPSUM BOARD.IS'FRAMNG I I OPTIONAL 5/e'GWD I I —NDR PER 9TFd1C. -- J L--_ L---J I STOPPED-N SCREEN PER OU.RER-SEE ELEVATION H I/A40 I PT 4x SILL W/G CEDAR WRAP I I FLOOR ELEVATION.000' FOOTWG PER STRJC. 4•CONC.SLAB PER STRJC.-SLOPE 1/0'PER FT AWAY FROM HOUSE 4"CONC.GARAGE SLAB APRON CA55.PER PLAN b'.24•CONC.FIND.WALL PER STRJC- -SLOPE 1/8"PER FT, J AWAY FROM HOUSE 12"x b"CONT.CONC.FTG,PER STRJC, 48'R-10 RIGID N5UL.AT SLAB PERIMETER 4•CONC.SLAB ON GRADE PER STRJC. 0 4'PEA GRAVEL OVER 6 MIL.VAPOR BARRIER.SLAB Pt SECTION A s H SCALE: 'tea" I'-m" co) Q = J 3 oao a 0 W UA Z N ROOFING PER SECTION tu OVER UNDERLAYMETIT a TERS.24"OC.PER STRIP- V W J YSED 4.8 BEAM PER STRUC, n ---- - - _ _. _-- - -- --- `--_--- _.— Lu W z 7 u 2•-6• / I I 4097 REGISTERED AR ITE.. II II � _ ___ —L L_— � � STAT Of WASHINCTON PRE-ENG.GABLE ROOF ———————I ———— —T T—— - y/ 4-' illl CURVW ROAM BEYOND - TRUSSES.24"OC. IX4 KAMEIM.24.OC.PER STRUC REVISIONS FORT CURVE,SUPPORTED BY KNEE BRACESOPTIONAL CLG.MSULATIONIIISHEATHING BOTH SIDES OF WALL T1415 WALL PER 5TRIJC. g 4 USN.PER GT1®1C. OPTIONAL 5/8"GWB.CLG.1 BEAM/POSTS AT FOREGROU� ��AS SELECTED BY OIA" HDR PER STRJC. � / — -----_—_ $ OPT"FRAMNGGWBOP7�HN ARRAGETT INSUL.NEDPA6CIA INED F'ORG-I 1:EDAR TRIM I 2E 6 CLG.JOIST98 SHEET CONTENTS TRIM 24.OC.W/OPTIONAL4x POSTs k I ■ ---- — :/n41"PLYUr EDW LIDRIM PORDGH DEING TAIL �REESON I I Al I I F' 9 OVER TOILET BEYOND 6>1&REc POSTS---- ; ; I I i F SHOP 7REGROWD I I II I I SLOPED APRON $ DATE 2 TRIM T>GE5 EASED i be VERT CEDAR STgP8 BEYOND I $ _-.. ---_-- - 1. -r.. _ .___.- I • i �-Y CF OPENNG) j I II _. .... .. ....,: DRAWN BY DAR P TRIMNw i I AJBO BASE PER STid1C{ N.S. LOPED SILL 1 I AT POSTS BEYOND —__-- � ——— —————L CHECKED BY PT 4.6 EDAR WRAP 4'CONC.GLAD PER STRUC.-05' L.A.W. ° STONE OR CULT.STONE VENEER OPTION 2 W/CCNC CAP— SHEET NUMBER SEE DETAIL 2/A3.1 PT 2.6 SILL PLATE W/AB-F'ER STRJC..48.OC.ON SILL SEALER-� 6"X 24'CONC.FND.WALL.SHOP PER STRJC-.—i/ SECTION B A 4.0 12-.b'CONT.CONC.FTC..SHOP PER STRUC.J SCREENED PORCH DETAIL OF a DRAWINGS WnHOUT WRrnEN PURMOF➢ENOFIFET6 P1b1191FD. 2X0 CMBVRAMM•24'OL. i 2 WILLIAMS r— A PLC-HIT`c-Tu=7 cuRVBD Rocs VALI TW W/12'METAL ROOFRYs PANELS GAB E • t o O 601 W.RAILROAD AVE 8/4xe CEDAR RAKE• P.O.BOX 102 OPTIONAL R-4'J BGA T I �VED ROOF SHELTON,WA 98W PH:(360)426-0511 ARAGE 4 lb-TYPE'X•GTP.BD. I i •SWOP CLG.4 WALLS CONI"ION W/REs. I 1 OPTIONAL 1.S ENT w 9TRIPo ADOVE ADJASCENT CLG.MSUL. 2x4 LEDGER RAFTERS PROVIDE MRE IAA so.NEED/�Lfl L!!OF 0.4 d1EAK EETOND OCKINGM PER STRUC. ——————_ I PROJECT NUMBER II� 2023028 SOFFIT LOO8 E ABOVE CAMS. NDR PER sTrdJc' PROJECT TITLE --- - -- i bx6 MUNTIN BAR BETWEEN SHOP IOTCHEN ii N ,I WINDOWS II II V R-5 RIGID NSUL. it I I� II II I 24•OATT'P. SECTION C OVERFRAMNG PER STRUC. ARClI.COMP.SHNGI.E ROOFRJG am ROOF 19P.AMIIAG RIDGE OF GABLE ROOF INFORECRJWp OVER UNDERLATMENT PER MM FOR VARIATION ROOF 514EATHING O OVERFRN'11NG PER S7RUC.•GABLE -. .-- ._ ��. ___ - - �1 NSUL.•CONDITIONED SPACES -SEE ELEV. N CONT_OVER TOP R b _ EDGE NAILING RE-ENG.LRdIsBES•24'OL. - _ PRE-ENGINEERED F' W/2xb TAILS TYP. - GABLE TRUSSES•24.O.G. PER ROOF FRAMING PLAN EPTH VENTED BLOCKING PMEL CURVED ROOF BM PER STUC.W/2x6 CRIPPLE WALL ABV.FOR TR18S 15— EEIW/12"METAL ROOFING PANEL9 -� VAUI F H-I CLIP•48.DO.PER&TRIG. 214 RAFTERS PER STRUC. • 4 O.C. I OR S•24 O.C. I � PRE-FNISI-ED METAL GUTTER Z • 0 = W I C ca Ma 3 CEDAR FASCIA PER ELEV. -- ---- ) CURVED BM.PER STRUC, 0 OOPTIONAL VENTED SOFFIT PER OWNER p`EE BRACES PER STRJC. 9 Q 12Lu W DOUBLE NAILER PLATE B SHOP ROOM rl000Ele— FLEX 3 v a rn W/(2)ROWS Wads•16" L.EA LATER / W GWB/INTERIOR FINISH PER OLLNER C WALL FRAMrW,t INSULATION PER SECTION H JJJ El Lu EXTEND 4 EDGE NAIL WALL%VATNING Q UP TO EAVE - 3 W R-5 CONT.RIGID NBULATION W J •CONDITIONED SPACES Z V W/TAPED JOINTS PER MFR EXTERIOR SIDING PER ELEV. CONT.2.2 BLOCKING/FRAME SECTION D 40'FAR"'I11'j1'1' AT ALL CONDITIONEDOPENING PERIMETERS TYR SCALE: I/4" = V-0" HEADERS PER STR1C.TYP. TATENCTo. -- REVISIONS EXTERIOR INTERIOR ----_--.---. - op SHEET CONTENTS OVERFRAMMG PER 5T1alC PROVIDE MIN. 6 9 ^5a IK FREE AIR/LIN.FT. BUILDING SECTIONS VENTED BLOCKING WALL SECTION 4"GONG.SLAB ------- -�■ R-10,48'•SLAB PERRIETER �- 4"PEA GRAVEL 3 - I DATE OVER b MIL.VAPOR BARRIER•SLAB A3.1 I 1-8-24 SHOP GARAGE I DRAWN BY FLASHING AS REQD FURR OUT WALL I'TO MATG.1 RESIDENCE SIDING K.S. OOC KAB WERE OCOJR5 I OR CONTINUE INSULATION THI5 WALL L'HECKM BY I LA.W. SHEET NUMBER A 4.1 SECTION E NALL SECTION 6 RESIDENCE SCALE I/4" = 1'-0" OF 8 3GALE: I" . I'-m" RBROICIIDN DR REUSE OF THESE DRAWWIOS WITHIM WRRTEN P6IMMOFTIEACHW6PR11 M