HomeMy WebLinkAboutCOM2022-00036 Mechanical - COM Inspections - 8/16/2024 INSPECTION CARD Mason County H 615 W. Alder St. Building 8, Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov PERMIT# COM2022-00036 PROJECT ADDRESS 50 E Island Lake Rd Shelton, WA 98584 PARCEL# 420121260040 PROJECT DESCRIPTION Add A/C unit OWNER CALVARY FELLOWSHIP SHELTON WA ADDRESS PO BOX 432 PHONE CONTRACTOR OLYMPIC HEATING &COOLING ADDRESS 181 SE MORGAN RD PHONE 360-426-9945 CONTRACTOR LICENSE OLYMPHC986BA LENDER INSPECTION INSP DATE Comments INSPECTION INSP I DATE Comments Mechanical/Plumbing Final 2 "s Mason County Mason County - Division of Community Development 615 W. Alder St. N C Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov FPROJECT 2-00036 MECH/PLUMB - COMMERCIAL ESCRIPTION: ADD A/C UNIT ISSUED: 03/15/2023 ESS: 50 E ISLAND LAKE RD SHELTON EXPIRES: 09111/2023 PARCEL: 420121260040 APPLICANT: CALVARY FELLOWSHIP SHELTON WA OWNER: CALVARY FELLOWSHIP SHELTON WA PO BOX 432 PO BOX 432 SHELTON,WA 98584 SHELTON,WA 98584 CONTRACTOR: OLYMPIC HEATING&COOLING 181 SE MORGAN RD SHELTON,WA98584 360-426-9945 GENERAL CONTRACTOR'S LICENSE: OLYMPIC HEATING&COOLING License: OLYMPHC986BA 181 SE MORGAN RD Expires: 01/01/2024 SHELTON,WA98584 360-426-9945 FEES: Paid Due Mechanical Base Fee $30.00 $0.00 Mechanical Fees $19.00 $0.00 Final Inspection $80.00 $0.00 Technology Surcharge $2.58 $0.00 State Fee-Commercial $25.00 $0.00 Totals : $156.58 $0.00 FIXTURES City Mechanical Fixtures 1.0000 Heat Pump(s) REQUIRED INSPECTIONS Mechanical/Plumbing Final Inspection Printed by:Nikita Huckabey on:03/15/2023 02:25 PM Page 1 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MECH/PLUMB - COMMERCIAL COM2022-00036 CONDITIONS Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be obtained at 1-800-647-0982. The person signing this condition is either the homeowner, agent for the owner or a registered contractor according to WA state law. * All construction must meet or exceed all local and state ordinances in addition to the International Codes requirements as adopted and amended by Mason County and the State of Washington. Occupancy is limited to the approved and permitted classification. Any non-approved change of use or occupancy would result in permit revocation. * All furnace installations shall meet the minimum efficiencies set forth in the current edition of the Washington state energy code (WSEC). any portion of the mechanical system that is altered or replaced shall meet the minimum standards set forth in the WSEC and international mechanical code. * Owner/Agent is responsible to post the assigned address and/or purchase and post private road signs in accordance with Mason County Title 14.28 and 14.17. * CONSTRUCTION PROCESS TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND THE ADOPTED BUILDING CODE. The construction of the permitted project is subject to inspections by the Mason County Building Department. All construction must be in conformance with the international codes as amended and adopted by Mason County. Any corrections, changes or alterations required by a Mason County Building Inspector shall be made prior to requesting additional inspections. * OWNER/BUILDER acknowledges submission of inaccurate information may result in a stop work order or permit revocation. Acknowledgement of such is by signature below. I declare that I am the owner, owners legal representative, or contractor. I further declare that I am entitled to receive this permit and to do the work as proposed. I have obtained permission from all the necessary parties, including any easement holder or parties of interest regarding this project. The owner or authorized agent represents that the information provided is accurate and grants employees of Mason County access to the above described property and structure(s)for review and inspection. This permit/application becomes null & void if work or authorized construction is not commenced within 180 days or if construction work is suspended for a period of 180 days. PROOF OF CONTINUATION OF WORK IS BY MEANS OF INSPECTION. INACTIVITY OF THIS PERMIT APPLICATION OF 180 DAYS WILL INVALIDATE THE APPLICATION. * All building permits shall have a final inspection performed and approved by Mason County Building Department prior to permit expiration. The failure to request a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being non-compliant with Mason County ordinances and building regulations. * All permits expire 180 days after permit issuance, or 180 days after the last inspection activity is performed. The Building Official may grant a one time extention of 180 days, upon the receipt of a written extension request prior to permit expiration. Letter must indicating that circumstances beyond the control of the permit holder preventing action from being taken. No more than one extension may be granted. Printed by:Nikita Huckabey on:03/15/2023 02:25 PM Page 2 of 3 Mason County Mason County - Division of Community Development 615 W. Alder St. N$' Building 8 Shelton, WA 98584 360-427-9670 ext 352 www.masoncountywa.gov MECH/PLUMB - COMMERCIAL COM2022-00036 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of Laws and Ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state/local law regulating construction or the performance of construction. Issued By: Contractor or Authorized Agent: Date: Printed by:Nikita Huckabey on:03/15/2023 02:25 PM Page 3of3 RE CEIVED MAY 112022 615 W. Alder Street MUST MEET ALL CURRENT �I4AS'HINGTnN STATE CODES wr h� opy THESE PLANS MU T BE ON THE JOB S E APP. FOR INSPECTI N ASON BUIE_• :SPECTOR :NGES S F ' .1PPROVHIti CHANGES SUBMIT CHANGES FOR APPROVAP PRIOR TO PERFORMING WO K V r3 .f-&-c� of I-t�l\ W S C 4 Pov 1 5 4r q S aS req , BUILDING REcEJ V TR�WE® ED MAY I , ��?2 615 � A/der Street Submittal SE IJST IVIES--7 = ,CURRENT Split System Heat Pump 4TWR406OG 1000A gg l 1 Note:"Graphics in this document are for representation only.Actual model may differ in appearance." THESE PLANS MUST BE ON THE JOB SITE FOR INSPECTION Tn N April 2020 4TWR4060G-SUB-1 D-EN = TE C NNOLOGiES rANVE' a C SERVICE PANEL ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 (5 FELT) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUNOFF RATER DOES 401 POUR DIRECTLY ON UNIT. AND SHOULD BE AT LEAST 305 112'I FROM VAll AND ALL SURROUNDING SHRUBBERY ON 1"SIDES. OTHER 100 51 DES UN RE S TR ICIE O. RECTRICAL SERVICE PAMEI K 25 111 A 22.2 11151 CIA. HOLE tON VMTAGE Z1.6 II•IIBI DIA. A.O. IITH 22.2 IT111 DIA. HOLE IN CONTROL BOY BOTTOM FOR ELECTRICAL POKER SUPPLY H F .O. FOR ALTERNATE 0 ELECTRICAL ROUTING L1WID IINE SERVIC( VALVE, 'F' 1.D. F[YALC BRAZE CONNECTION NITH I1d' SAE GAS LINE 114 TURN BAIL SERVICE VALVE. 'D' F LANE INESSURE TAP FITIINGS. 1.0, FEMALE BRAZED CONNECTION KITH I11• SAE F TARE PRESSURE TAP FITTING. Model Base A B C D E F G H J K 4TWR4060G q 1147 946 870 152 98 219 86 813 (45-1/8) (37-1/4) (34-1/4) 7/8 3/8 (6) (3-7/8) (8-5/8) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz- 125 Hz J 250 Hz 1 500 Hz 1 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR406OG 72 81 72 1 68 1 71 68 64 59 54 Note:Rated in accordance with AHRI Standard 270-2008'For reference only. 2 4TW R4060G-SUB-1 D-EN TRANS' Product Specifications OUTDOOR UNIT(a)(e) 4TWR406OG1000A (a) Certified in accordance with the Air-Source Unitary Alr-conditioner POWER CONNS.—V/PH/HZ(1) 208/230/l/60 Equipment certification program,which is based on AHRI standard _ 210/240. MIN.BIRCH,C1R,AMPACITY 32 IN Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 50 (`) Calculated In accordance with Natl.Elec.Codes.Use only HACK circuit breakers or fuses. COMPRESSOR CLIMATUFFO-SCROLL W This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(a)—L.R.AMPS 24,4—144 M No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. START COMPONENTS WNO(Uses BAYKSKT263) (r) Standard Air—Dry Coil—Outdoor (9) This value approximate.For more precise value see unit nameplate. INSULATION/SOUND BLANKET NO IN Reference the outdoor unit ship-with literature for refrigerant piping COMPRESSOR HEAT NO length and lift guidelines.Reference the refrigerant piping software pub A 32-3312-xx or refrigerant piping application guide SS- OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes latest revision). DIA.(1N,)—NO.USED 27.5—1 (1) The outdoor condensing units are factory charged with the system TYPE DRIVE—NO.SPEEDS DIRECT—1 charge required for the outdoor condensing unit,ten(10)feet of tested connecting line,and the smallest rated indoor evaporative toll CFM @ 0.0 IN.W.G.(f) 4890 match.Always verify proper system charge via subcooling(TXV/EEV) NO.MOTORS—HP 1—1/5 or superheat(fixed orifice)per the unit nameplate. MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L.AMPS 1.05 OUTDOOR COIL—TYPE SPINE FIN" ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 30.8 TUBE SIZE(IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS.—R-410A(0.D.UNIT)(A) 10 LBS.,13 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS W(') 1 1/8 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS FIX W X D CRATED(IN.) 51 x 38.7 x 35.1 WEIGHT SHIPPING(LBS.) 315 NET(LBS.) 278 4TWR4060G-SUB-1 D-EN 3 TRNNE' Mechanical Specification Options General Compressor The outdoor condensing units are factory charged with The compressor features internal over temperature and the system charge required for the outdoor condensing pressure protection.Other features include:Centrifugal unit,ten (10)feet of tested connecting line,and the oil pump and low vibration and noise. smallest rated indoor evaporative coil match.This unit Condenser Coil is designed to operate at outdoor ambient temperatures as high as 115°F.Cooling capacities are The outdoor coil provides low airflow resistance and matched with a wide selection of air handlers and efficient heat transfer.The coil is protected on all four furnace coils that are AHRI certified.The unit is certified sides by louvered panels. to UL 1995.Exterior is designed for outdoor Low Ambient Cooling application. As manufactured,this system has a cooling capacity to Casing 55'F.The addition of an evaporator defrost control Unit casing is constructed of heavy gauge,galvanized permits operation to 40oF.The addition of an steel and painted with a weather-resistant powder evaporator defrost control with TXV permits low paint finish.The corner panels are prepainted.All ambient cooling to 30'F. panels are subjected to our 1,000 hour salt spray test. The addition of the BAYLOAM107A low ambient kit Refrigerant Controls permits ambient cooling to 20°F. Refrigeration system controls include condenser fan, Thermostats—Cooling only and heat/cooling (manual compressor contactor and low and high pressure and automatic change over).Sub-base to match switches.A factory supplied,field installed liquid line thermostat and locking thermostat cover. drier is standard. 4 4TWR4060G-SUB-ID-EN MAKE" Trane - by Trane Technologies (NYSE: TT), a global innovator - creates comfortable, energy efficient indoor environments for commercial and residential applications. For more information, please visit trane. com or tranetechnologies.com. wad CERTIFIED C VL US LISTED The AHRI Certified mark indicates Trans U.S.Inc.participabun in the AHRI Certification program.For verification of individual certified products.go to ahridirectory. org. Trans has a policy of continuous data improvement and it reserves the right to change design and specifications without notice.We are committed to using environmentally conscious print practices. 47WR406OG-SUB-ID-EN 28 Apr2020 Supersedes 4TWR4060G-SUB-IC-EN (October 2019) -5)2020 Trans