HomeMy WebLinkAboutCOM2004-00120 Steel Bldg for Warehouse Storage - COM Permit / Conditions - 5/5/2005 MASON COUNTY DEPT. OF COMMUNITY DEVELOPMENT Inspection Line(360)327-7262
Mason County Bldg. 3 426 W. Cedar P.O. Box 186 Phone: (360)427-9670,ext. 352
Shelton, WA 98584
Irpo"
COMMERCIAL BUILDING PERMIT COM2004-00120
OWNER: RICHARD EGER RECEIVED: 5/28/2004
CONTRACTOR: STEPHEN JOHNSON INC LICENSE: STEPHJ*199LW EXP: 6/1/2006 ISSUED: 8/2/2004
SITE ADDRESS: 390 NE ROY BOAD RD BELFAIR EXPIRES: 2/2/2005
PARCEL NUMBER: 123282390010
LEGAL DESCRIPTION: TR 5 OF SW NW LOR: A OF SP#1943
PROJECT DESCRIPTION: DIRECTIONS TO SITE:
STEEL BUILDING FOR WAREHOUSE STORAGE HWY 3 NORTH STOP LIGHT BELFAIR LEFT FIRST RIGHT PAST
SAFEWAY ON ROAD ROAD 1/2 MILE ON RIGHT
General Information Construction &Occupancy Information
Type of Use: WAREHOUSE Insp.Area:
No. of Units: Type of Constr.: II-N
Type of Work: NEW Fire Dist.: 2 No. of Bathrooms: Occ. Group: S - 1 Valuation: $ 254,220.00 No. of Stories: 1 Occ. Load: 20
Building Height: 16
Pre-Manufactured Unit Information Square Footage Information
Make: Length: Lot Size:
Model: Width: Building: 6,000
Year: Serial No.: Basement: Parking Spaces:
Setback Information
Shoreline & Planning Information
Front: W 90.00 Ft. Shoreline: Ft.
Rear: E 668.00 Ft. Slope: Ft. Water Body: Shoreline Desig.: Not Applicable
Side 1: N 90.00 Ft. SEPA?:No Comp. Plan Desi .:
9 Urban Growth Area
Side 2: S 20.00 Ft.
Fire Protection System Information
Auto Fire Alarm System?: Y Emergency Key Box?: Y Standpipe?: N
Auto Fire Sprinkler System?: N Access Road?: Y Fire Extinguishers?: Y
Fixed Fire Suppression System?: N Fire Hydrants?: Y Fire Lanes?: N
COM2004-00120 Please refer to the following pages for conditions of this permit. 1 of 5
Plumbing Fixtures Mechanical Fixtures FEES
Type Qty. Type Qty. Type By Date Amount Receipt
Hosebibts 1 Additional Fixtures 1 Plan Check Fee Tw R/9R/9nnA R1 9nR An R1,nnAnn
Lavatories 1 Ventilation Fan 1 Planning Review Fee Tw /,?R/gnnA .40cA nn R1?nnAnn
Water Closets (Toilets) 1 Address Fee rMM 9/1Onna ,t1An nn R,,nnAnn
Water Heaters 1 Building State Fee MRr. R/9,/9nnA RA x;n R99nnAnn
Building Permit Fee MRr; R/7'2/gnnd R1 RR1 75 R77nnAnn
Plumbing Fee MRr, R/,?,A/9nnd R9R no R79nnAnn
Plumbing Base Fee MRr R/9R/9nnA R9n nn R99nnAnn
Mechanical Fee MRr R/9R/9nnA R7 79; R99nnAon
Mechanical Base Fee MRr, R/9R/9nnA owi 1;n R99noAnn
Public Works Review AT R/an/gnnA RRQ 9,? R�,?nnann
UFC Plan Check Fee RAR 7/�tnnnA RRnR n7 R,??nnAnn
Public Works Review AT 7/1a/9nna RRQ 79 R99nnann
EH Plan Review AnR 7/91/9nnd R79;on R99nnann
Total $4,302.91
CASE NOTES FOR
COM2004-00120
CONDITIONS FOR
COM2004-WI20
1) Contractor registration laws are governed under RCW 18.27 and enforced by the WA State Dept of Labor and Industries, Contractor Compliance
Division. There are potential risks and monetary liabilities to the homeowner for using an unregistered contractor. Further information can be
obtained at 1-800-647, 82. , e per o K Ing this condition is either the homeowner, agent for the owner or a registered contractor according to
WA state law. X /e- /,I
2) Two conditions
Furt a Radant Floor heat cannot be hook-up, show proof that you will not exceed 44 degrees.
X
Separate permit for each tenant proir to construction or occupancyof,the tenant. Shall application are subject to further review under the tenant
improvements
3) All approved plans are required to be on-site for inspection purposes. If inspection is called for and s are not on site, Approval WILL NOT be
granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will e d and collected by the Mason County
Building Department prior to any further inspections being performed or approvals granted. X
COM2004-00120 2 of 5
4) PURSUANT TO 1997 UNIFORM BUILDING CODE, ALL SITES MUST HAVE APPROVED NUMBERS OR ADDRESSES PROVIDED IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. MASON COUNTY
BUILDING DEPARTMENT REQUIRES THAT THIS BE COMPLETED PRIOR TO CALLING FOR ANY SITE INSPECTIONS. A REINSPECTION
FEE, BASED ON RATES AS ADOPTED BY THE JURISDICTION AND THE 1997 UNIFORM BUILDING CODE WILL BE ASSESSED IF
OWNER/CONT TOR FAILS TO POST ADDRESS ON SITE PRIOR TO REQUESTING INSPECTIONS.
X / "
5) This structure 1 is approved as semi-heated space as identified in the Washington State Non-Residential Energy Code section 1310.2.
_
X
6) 3000 PSI CONCRETE WILL REQUIRE SPECIAL INSP CTION IF THE dU4NTITY EXCEEDS 50 CUBIC YARDS< LESSER AMOUNTS WILL
REQUIRE AN APPROVED CONCRETE SUPPLIER TO PROVIDE YOU WITH A BATCH TICKET THAT] WILL BE REQUIRED TO BE
SUBMITTED TO THE SITE INSPECTOR FOR THE VERIFICATION OF MATERIAL USED. X i' �
7) 1997 UBC CHAPTER 17, SECTION 1701: IN ADDITION TO THE INSPECTION REQUIRED BY SECTION 108, THE OWNER OR THE
ENGINEER OR ARCHITECT OF RECORD ACTING AS THE OWNER'S AGENT SHALL EMPLOY ONE OR MORE SPECIAL INSPECTORS
WHO SHALL PROVIDE INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER SECTION 1701.5. THE
SPEC L INSPECTORS DUTIES & RESPONSIBILITIES SHALL BE AS SPECIFIED IN 1701.2 AND 1701.3.
X i e Y�
8) Any changes in construction shall be reviewed by engineer of record and submitted in writing to the Mason County Building Department prior to
construction. All engineering documents are a part of the approved set of plans and must remain attached thereto. If engineering documents are
removed, approval will not be granted. In addition, a reinspection fee, based on the current fee schedule, minimum one-hour will be charged and
colle to by,ythe Mason County Building Department prior to any further inspections being performed or approvals granted.
X �
9) Changes to approved building plans that affect compliance to the current non-residential Energy Code (NREC), ventilation and Indoor Air Quality
Code (xIA IA) Building/Plumbing/Mechanical Codes and/or Mason County Regulations shall be approved prior to construction.
10) CONSTRUCTION PROC��§i,TO BE FIELD CORRECTED AS REQUIRED PER MASON COUNTY BUILDING DEPARTMENT AND UNIFORM
BUILDING CODE.x J;^ i
11) All property lines shall be clearly identified at the time of foundation inspection. X
12) All building permits shall have a final inspection performed and approved by the Mason County Building Department prior to permit expiration. The
failure to re�q��JJest a final inspection or to obtain approval will be documented in the legal property records on file with Mason County as being
non-co(r)Sly�t ith Mason County ordinances and building regulations.
X ����(L��'`C�
COM2004-00120 3 of 5
13) An Automatic Fire Alarm Syst m meeting NFPA 72 standards is required to be installed. This system shall be monitored by an approved UL listed
central recieving station. Th f r I rm control panel (FACP)shall be located in a heated space. A seperate plan review and permit are required
from the fire marshal. X
The door to the FACP shall be labeled. X
A Knox Box(emergency key box)shall be required. Contact fire dist. #2 for purchase information. X
Provide one 2A 10BC fire extinguisher at ea d of the building in an approved weather protective cabinet. Mount no more than 48"from the
groung to the top of the extinguisher. X
YY'G-�`� �S�S — L� >C�xe.� ('J�\ ' `T cs' c ,�-err—
Afire hydrant shall be located within 300'of the entrance to the site. X
14) The proposal shall conform to the provisions and recommendations of the stormwater site plan, prepared by Mkie W k and dated March 22,
2004. A copy of the plan shall be kept onsite during construction and made available to inspectors. X �"� ,
15) An Operation and Maintenace (O&M) Covenant must be created to cover the constructed stormwater features. P/W requires notification when the
site improve��? is have been completed so that the stormwater features may be inspected. Contact Alan Tahja at 360-427-9670 x461 for details.
X T-r
16) Approve p r dimensions and setbacks on submitted site plan. Setbacks are measured from the furthest projection of the structure.
X
17) Parking equirements for 2 spaces, one of which must be signed for handicapped use. X
This permit becomes null and void if work or construction authorized is not commenced within 180 days,or if construction or work is suspended for a period of 180 days at any time after work is
commenced. Evidence of qcTtinuation of work is a progress inspection within the 180 day period. Final inspection must be approved before building can be occupied.Proof of continuation of
work is by means of a progr s insp tion.The ow ro agent on the owners behalf,represents that the information provided is accurate and grants employees of Mason County access to
the above described pro and r cture fo r nd inspection.
OWN ER OR AGENT: DATE: 7�
COM2004-00120 4 of 5
Lbt
o
CONCRETE MECHANICAL MANUFACTURED HOME
N
o Footings / etbacks Date By Ribbons
oDate /a p y Gas Piping /ter Date B y
N Foundation Walls Date —2,�-o B y r/� Set-up
Date By INSULATION Date By
B G / Slab Insulation Floors Final
D ate W 3 .q By -Ox-- Date B y Date B y
FRAMING Walls FIRE DEPT
Date By 7—A . Date I B yL4X, Date B y
PLUMBING Attic OTHER
Groundwork Date a / d5— ByI.Y)iL
Date By WALLBOARD NAILING
D.W.V. Date By
Date V — .f- By ;,e FINAL INSPECTION
Water Line / Date B y 7/Z
Date a(/ By N N. �. , Date
r 144-0 f OA4 5--
y �q 7rT,y�sr
N
,J` .2 - o
N
O
cn
0
cn '
STgTF°� MASON COUNTY
o A o N DEPARTMENT OF COMMUNITY DEVELOPMENT
r S N Planning Division
o Y 0 P O Box 279, Shelton, WA 98584
(360)427-9670
ra6A
NOTIFICATION OF INCOMPLETE APPLICATION
June 03, 2004
RICHARD B EGER
8128 187TH SW
EDMONDS WA 98026
Parcel No.: 123282390010
Project Description: STEEL BUILDING FOR WAREHOUSE STORAGE
Dear Applicant:
You have submitted a permit application (case no. COM2004-00120) for proposed
construction or development in the county. Upon review of your application, I have
determined that the contents of the application are incomplete or do not provide
enough detail for review.
Therefore, review of your application will not proceed until the necessary information
is provided (see the comment section of this letter for details.) Once the information
is submitted and the application is complete, I will continue to process your
application accordingly. If the additional information is not provided to the County
within 180 days of this request, the application shall expire and no further action on
the proposed development shall take place.
Please contact me at (360) 427-9670, ext. 577 if you have questions.
Z
Rick Mraz n
Land Use Planner
Mason County Planning Department
comments: Per the comments and information presented at the pre-application
meeting for this proposal, a geotechncial report or addendum to
existing report for the neighboring site is required for permit review.
6/3/2004 1 of 1 COM2004-00120
oN_ST,TF MASON COUNTY
�P5 C � DEPARTMENT OF COMMUNITY DEVELOPMENT
° "N N PlanningDivision
o Y �? P 0 Box 279, Shelton,WA 98584
(360)427-9670
1864
NOTIFICATION OF INCOMPLETE APPLICATION
July 06, 2004
RICHARD B EGER
8128 187TH SW
EDMONDS WA 98026
Parcel No.: 123282390010
Project Description: STEEL BUILDING FOR WAREHOUSE STORAGE
Dear Applicant:
You have submitted a permit application (case no. COM2004-00120) for proposed
construction or development in the county. Upon review of your application, I have
determined that the contents of the application are incomplete or do not provide
enough detail for review.
Therefore, review of your application will not proceed until the necessary information
is provided (see the comment section of this letter for details.) Once the information
is submitted and the application is complete, I will continue to process your
application accordingly. If the additional information is not provided to the County
within 180 days of this request, the application shall expire and no further action on
the proposed development shall take place.
Please contact me at (360) 427-9670, ext. 577 if you have questions.
Since e ,
Rick Mraz
Land Use Planner
Mason County Planning Department
Comments: The storm drainage report has been reviewed by the Mason County
Public Works Department. Please review the attached IDC for details
regarding additional information necessary to complete review.
7/6/2004 1 of 1 COM2004-00120
MASON COUNTY PERMIT NO. t::2L r
BUILDING PERMIT APPLICATION _. DLJ �G
426 W. Cedar • P.O. Box 186, Shelton, WA 98584
Shelton (360) 427-9670 • Belfair (360) 275-4467 • Elma (360) 482-5269
On the Web www.co.mason wa.us
APPLICANT INFORMATIQN CONTRACTOR INFORMATION
Owner t'L� L. �' Contractor Name S� h S o n�Nc
Mailing Address I —t r5 L4j Mailing Address u X
City.�c�vv�0✓dS State ip Code OL 8 City E I State Zip Code S L
Phone( ) Other Ph. ( ) Phone (to) 2?-76730fher Ph. ( )
Lien/Title Holder Contractor Reg.
Email Address Email Address
SEPTIC/WATER SYSTEM INFORMATION - Connect to New Septic Existing Septic
Conne t t Sewer System Name of Sewer System
Well 74 Water System Name of Water System
PARCEL INFORMATION - 12 digit Tax Parcel No. 3 /��/ 900 / b Fire District Z
Legal Description c5 L -e Z,
Site Address (Please include street name, street number and city) AA
irections to site I-a�.1 r -t L1 s4�
rti3 ClH R0 OG
Will timber be cut and sold in parcel preparatio ? (Yes/No) /V 0 "
Is property located within 200' of saltwater e River/Creek Pond
Wetland Seasonal Runoff trey Slopes or Bluffs
PERMANENT RESIDENCE ❑ SEASONAL RESIDENCE ❑
TYPE OF JOB - New X Add Alt Repair Other Use of Building
Is this permit submittal the result of a Stop Work Notice, Correction No ice o o her enf ement action? (Yes
Describe Work yr -fi ^,.A L , Gt J ( St
e - l'd
No. of Bedrooms 0 No. of Bathrooms / SQUARE FOOTAGE- 1 Flo r d U 0, 2nd Floo
3rd Floor Loft Basement Deck Other sq. ft.
Garage Attached Detached Carport Attached Detached
MANUFACTURED HOME INFORMATION - Make Model Model Year
Length Width Serial No. No. of Bedrooms No. of Bathrooms
Type of Heat Purchase Price $ Replacement Unit? (Yes/No)
Installer Name % Certification No.
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN
180 DAYS OR IF CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER
THE WORK IS COMMENCED. PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. THE
OWNER OR AGENT ON OWNER'S BEHALF, REPRESENTS THAT THE INFORMATION PROVIDED IS ACCURATE AND GRANTS
YEES
OF
ason
COUNTY ACCESS TO THE
VE DESCRIBED
PROPERTY
STRUCTUE toll)
NSPEOCT ON OF TIHIS P O ECT. OWN RIBUIILDER ACOKNOWL DGES SUBMISSION OFDINACCURATEk AWAY
RESULT IN A STOP WORK ORDER OR PERMIT REVOCATION. ACKNOWLEDGEMENT OF SUCH IS BY SIG_�jATl2�BW:
OWNER AFFIDAVIT- I certify that I am exempt from the require- CONTRACTOR'S AFFIDAVIT - I certify that 11YYll��i1��11 clUfrrrently regis-
ment of the Contractor Registration Law RCW 18.27 and am aware tered as a contractor in the State of Washington� ho��r to WW.
of the ordinance requirements for which this permit is issued and of the ordinance requirements regulating o for which this
that all work will be done in conformance therewith. No changes permit is issued and all work shall be done in conformance there-
shall be made without first obtaining approval. with. No changes shall be made without first obtaining approval.
i
X Date X Date S" Z7 D
FOR OFFICIAL USE BEYOND THIS POINT
Accepted by Planning Pd Ck#
Date Bld Pd. Reciept No.
DEPARTMENTAL REVIEW ..A P OVED DENIED CONDITION CODES
Building Department
Occ Group Type Constr. v
Planning Department
Environmental Health Department CAI WafrA
Public Works Department nA
Fire Marshal
Valuation $ /
FEES
Building Permit Fee Site Inspection
Plan Review Fee EH Review Fee
Plumbing& Base Fee Planning Review Fee
Mechanical&Base Fee Other
Wood/Gas/Pellet Stove Fee State Fee
Violation Fee Pre-Paid at Submittal ( )
TOTAL FEES
PERMIT NO.:
MASON COUNTY
PLUMBING/MECHANICAL PERMIT APPLICATION
426 W.Cedar/P.O.Box 186 Shelton,WA 98584
Shelton(360)427-9670 Belfair(360)i75-4467 Elma(360)482-5269
APPLICA T INFORM TION,� }�.R CONTRACTOR IN ORMATION
Owner ��,`� , — A P. — Contractor Name 1,
Mailing Address Mail jnq Ad ess
City State Zip Code City 1 I nL State LL2jL, Zip Code
Phone( Other Ph.( Ph. () Z.2 Other Ph.(� )
Lien/Title Holder Contractor Reg. # -t I `1 'l
Address Expiration
SEPTIC INFORMATION-Connect to New Septic Existing Septic<_Connect to Sewer System Name of
Sewer System
PARCEL INFORMATION- 12 digit Tax Parcel No. 3 ?— / Z 3 !Flo O / Q Fire District Z...•
Legal Description
Site Address(Please include street name,street number and city)
Directions to site
Is your property within 200'of the following: Body of Water(Name) /v D Saltwater
Lake River/Creek Pond Wetland Seasonal Runoff Stream
Slopes or Bluffs
TYPE OF JOB New Add Alt Repair Other Use of Building 5'tCUr
Location of Fixtures/Units 1st Floor 2nd Floor Basement Garage v Closet
PLUMBING FIXTURES (Show Number of each) MECHANICAL UNITS Fuel Type: Electric
Type of Fixture No.of Fixtures Fees LPG Natural Gas Heatpump
Toilets _� Type of Unit No.of Units Fees
Bathroom Sink Furnace I
Bath Tubs Heatpumps
Showers Spot Vent Fan /
Water Heater / Propane Tank
Clothes Washer -# Gas Outlets
Kitchen Sinks / Wood/Gas/Pellet Stove 2—
Dishwasher Kitchen Exhaust Hood /
Hosebibs 2/ Dryer Vent
Other Other
Base Fee Base Fee
TOTAL PLUMBING TOTAL MECHANICAL
A FLOOR PLAN AND PLOT PLAN MAY BE REQUIRED DEPENDING ON THE TYPE OF FIXTURE/UNIT.
I
NOTICE: THIS PERMIT BECOMES NULL&VOID IF WORK OR CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS OR IF
CONSTRUCTION WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 180 DAYS AT ANY TIME AFTER THE WORK IS COMMENCED.
PROOF OF CONTINUATION OF WORK IS BY MEANS OF A PROGRESS INSPECTION. The owner or agent on owner's behalf,represents that the
information provided is accurate and grants employees of Mason County access to the above described property and structures for review and
inspection of this project. Acknowledgment of such is by signature below:
OWNER AFFIDAVIT-1 certify that I am exempt from the requirements of the CONTRACTOR'S AFFIDAVIT-1 certify that I am currently registered as a
Contractor Registration Law RCW 18.27 and am aware of the ordinance contractor in the State of Washington and that I am aware of the ordinance
requirements for which this permit is issued and that all work will be done in requirements regulating work for which this permit is issued and all work
conformance therewith. No changes shall be made without first obtaining shall be done in conf an therewith. No changes shall be made without
approval. first o appro I.
X Date X - D a t e,5,�170
?FEF gl L USE BEYOND THIS POINT
(fi!�
Accepted b Date Submittal Amount Due Receipt No.
P Y
L3EPA}ZT:MEA1TAE liENtE1iY » APPROVED .DENIEt} GONDFrIQN CODES
Building Department
Occ Group Type Constr.
Planning Department
Other
Other
SEES
Permit Fee Site Inspection
Plan Review Fee UFC Plan Review Fee
Plumbing&Base Fee Other
Mechanical&Base Fee Other
Wood/Gas/Pellet Stove Fee Pre-Paid at Submittal ( )
Violation Fee TOTAL FEES
100'-0'
-
ON Im DR
I
I I II
II
it
I I
II
II
II
METAL BLD6 • FO{JWATM eY aree" I I
II
II
II '
II !!
4 I,
I I it
ILL x n
i- RLI. S/o
t' 13
r
n -
omcz R�Y1510tt5
s/o -
L THE GONTRALTOR'.1V"GOOICDWATE A V1'R✓y
ALL IWIGIOR BOLT Sm R LOGATI"dill E.PROVIDE AMCMATIG FIRE ALAM4 5r S M�TOR V BY THE aXX"~ACn$WC A RL GEtTrW CDtnRAL I!Xl STATOII 5Q 5HOr VM& 6ENERAL NOT, 5734
R
2-71e BULDIHs 4 Fou al TO x 4-�''�BLDd°�®4°�°�®W"OTHERS
A EFG ISTER CH ITE CT
ED
♦?t CC546NM F TVE MTT IEG. I.HOTW Y DE5WNCVAFZHrTEGT/5MSlmR r'5rr!AL CODE 1997 UBC
tt L/-V\ L'
NM' bO MR4 c4HvTTlO N 5.4Ok7R aN.DNi DST.REOIw ANY DE516fi�! :
UnWv ZONE 5 1•10 M7OPX nowS To THME RA.45 FVWK TO
DATA-
ROOFU. 75 FY Cat�Q✓UN6 momM'
ROOF DL 10 r5F
m CONTRACTOR TO ueac VE
RIFY D'e N'°'a (n i S. L CONG7QTE SAMLL HAVE A]D DAY BEFOIeE C.ON6TR�GTIGTL THOMAS A.HERSTAO TYPE CON5T. V - N
WWREWYE sneeeH Fa•2500 PoI OCC. GROUP 5 - 1 B
515 SACK KX 5.HlST NQr OR EYGem M-m vemATIOH A m"Y STATE OF WA$HINGTON
�_ OGC.UPANCY 185 45
4.ALL DSI?�1m OKO1tC.A16 STEQ 5IMi1
Be AdSTM A ee 6RAOE,o Fy.,opoo NeI FLOOR AREA 5555 50. FT. 445 50. FT.
s.ALL raDs+er T10 Be DONE By rwao cacrr9eD reDecs TOTAL AREA bOOO 50. FT.
6.P 04M trJ 2A MG PRE MoHmi_-te"To e e Hou"m HEIGHT ONE STORY
HEM THE EMT DOORS N CLEAR Vbi 4 REIGN N rrATlE2 FROOF C-Am W I
T.PROMO[A%6N AaOVE FRONT HNH GQT To 5AY
W
DOOR 7O RmIAAI RKPGA'ID DI.RR16 BuSRes HOUtS'
2
~ r r r r a w
EN
I MEM4 I'ria
L Ilk
L- t
r
Ar�I�1 uvdraer u r cm
MUc 1WL �r"iL uvAnaec
dRA�D MON" GLGAit Mom a,)%=
■
BARRIER FRIG NOTES
I. ALL DOORS RSXARJNS FULL IJUR PA56A6E ARE TO NAVE A MINIM.M CLEAR OPEMN6 MOTH 32'. THE MAXIMIPI TIfmSHOLD FE16HT
TO BE 1i'ALONE AcLESSIBLF ROUTE OF TRAva-
2. IN ALL COMMON AND PLeUC,L15E AREAS PROVIDE A MINI"OF 18'LNOBSTTd1CTED FLOOR SPACE BEYOND STRIKE.1+ 6 ON THE SIDE
OF hE DOOR 5006. IF TIE DOOR 5 S8F-CLOSNS AID S..E.F-L4TCHIN6,PROVIDE 12-133EYOW STRIKE We ON THE OPP0547E SIDE OF TI-E
DOOR SKINS NOT APPLICABLE TO DOORS NOT FTaARJNS FLLL V5M PA56A6 . MAX OPM%ME6HT•65 ba. � h
3. AT ALL COt- Y AND I°L.BLIC LISE ARFA5 PROJ[DE A MINIKH OF 48'UNOB5TR IX-TED FLOOR SPACE PERP6mIC1d AR TO T}E
DOORWAY M 43ZE A DOOR MUST LSE PALED TO BE OPENED.
4. M1fELC"R ACCE5NBLF TOILET 5TAI-LS 5FA-L NAVE A CLEAR MOTH OF 5'-0'. THE DEPTH OF THE STALL SHALL BE 4'-8'NTH WAtJ_4t%WATER }
a-35ET5 AND 4'-II'MOTH FLOOR-MOUNTED MTER CLOSETS. 1
5. PROVIDE A MINIKH OF 60'DI.N ETER UNO55TFW-T®FL OM SPACE MBTHIN THE TOILET ROOM. DOORS IN ANY POSITION!MAY ENCROACH •�r
INTO T}E SPACE NOT MORE THAN I2',AND THE CLEAR FLOOR SPACE MAY INCLIAE KMM AID TOE CLEARANCES NOT TO EX=19'
EXTENVIN6 LNDEIR THE LAVATORY OR 5W o
6. PROVIDE 6RAB BARS OR REIIFORCMS FOR 6RAB BARS AT WATER CLOSETS PER WASHI6TON STATE BIALDIN&CODE SECTION 3106"L
AID 3016(aa12A AND 3106(k)Il.
7. LAVATORY RJM FE16HT SHALL SE NOT 1,16HER THAN 34'ABOVE THE FINISHED FLOOR,KTH 24'MINIKH CLEARANCE FROM THE BOTTOM OF REYISIOALS
WE APRON TO TI-E FINISHED FLOOR
8. PROVIDE AN UNOBSTRJ.CTED FLOOR SPACE 30'MEDE BY 48'DEEP AT EACH ACCEreABLE LAVATORY. THE CLEAR FLOOR SPACE MAY WLVE
*EE AID TOE CLEARANCE5 NOT TO EK=19'DOUNDIN5 LNVER THE LAVATORY.
4. PROVIDE AN LW135TRUGTED FLOOR SPACE OF 60'N D1AME1732 MtlTHIN THE KITaEL
10.MAXTM.M RAMP SLOPE TO BE 1:12 N DIREGTIOH OF TRAVEL PER Mt56C 56rTION 3100V2. CROSS-SLoPE5 OF RA4 5 AND AGGE5515LF
Ra)TE5 OF TRAVEL SHALL NOT EXC.I$D 1:48 PBR MEBC SECTION 3106(d8.
11,IF RAM'SLOPE 15 6REATER TT"1:20,PROVIDE HAZDRALS PER MteC,SECTION 3IOW5.
a ALL CONTROLS AND OPERATTNS HARDWARE AT COWON AND P 13UC USE AREAS MdLL BE L.OGATi D PER t6er-SECTION 3106(c 2.
R3.IN A a550LE VNa.LJNS,LNATS,OP3ZA (-E M(NIXN HARDWARE SHALL HAVE LEVER TYPE OR OTH R HMDLP5 OP82ABLF BY MRI5T,
A !"I OR 54OU-PER AND BE LCv-AT®NOT LF55 THAN WAND NTT MORE THAN 48'ABOVE THE FN&M FLOOR 3106(cY2
14.ALL CONTROLS AND OPERATLN6 HARDWARE AT COW6141 AND PUBLIC U5E AREAS WILL 13E LOCATED PIR YCOr,SECTION 3IO c.)2.
T1f FINI5HED FLOOR 3106(c)2
5731
REGISTERtO
ARCHiTtM
THOMAS A."at"
STATE OF WAJ04o
W
I ,
I I it I I
I I II I I
I I II I I � -
I
I GN DR
f---------J it L1MDR I �`
II L---------j
II Ait
II
II
II
rerAL xn&. rawAnoN EK orteRs I i
II
II
II
II
II !
r
n
I
mm,wz OFFICE
�r
r
°
�° REVI510r15
g
i
i
I
i
NOTE
I. THE OONIRAGTOR SW1.L CfbRDINATE 1 VER)PY
ALL ANG110R BOLT Sim LOOATIONS I°T}i 8.PROJIDE AVTOMATIG RRE ALARM SYSTEN MDWOF=BY
7VE BIKDRI6 MANR'AGTUm� All OBtTIPt®OBfTRAL RBGEVN&STATION. SEE SHOP DYKE.
1.TIE BULDIIK 4 FMMATION TO Be 4.METAL 515MEERED BY OTH,,S
DBSIbItw PER TIE MfT Lly
595 MPN I.NOTiPY Ve5l6NBVAPlVfrWTi916PEM IF Sn /'��p
ROOF L 25 F 9 .10. COIAmONS AND/OR BULDM6 DITf. ANY PLOD t PLAN• 5734
ROOF LL. a PSF �rornFICATIOIe ro Tlrx PLANS PRIOR ro ""r■ DE516N DATA:
R�D� p P� 1N6 c 7ARCmITECT
STERED
9.'�ATE` L iMYE A D8 DAY 1 OQRRAOTOR TO&WA 4 y0trr ALL VMeajad CODE aq 1 ��
sh srmrtH F�.aoo PSI BEPORE CONmzrOK /T1Y�P�E�G�O�NyS�T. Y - N
S.HRST MEer OR ENO MRT VDff6AT10N BRyY OCC. c7RO 5 - 1
4.ALL Da�DIe�Efl IOROM6 sTm sNALL OODE,S. n
A3Tli A ie GRADE 4o Fy.40AXO PSI OCCUPANCY 18.5 U
s.ALL Yaar+s To Be Dow BY rVeo ca"Fri D YELDBRS. CT"WA"S A.NEigTAD 4.5
SF wAl�+INGTON FLOOR AREA 5555 SQ. PT. 445 50. FT.
6.AR.o� E(21 7A Ioec FIFr EMN6USNERs TO es Mourt» TOTAL AREA 6000 SQ. FT.
NEAR TIE EJOT DOORS M G1EAR VEW 1 REAOH M YG.TI[1!PROOF O,�B9 L1C
T."DOPROV LL'1O A SISN ABOVE PROM MAN EMT TO SAY
T}MS ` ..�f!�. HEI&HT ONE STORY
' 0R 1C TO REMAIN N ®q,R
LLLAINb BUSII!'9 HpLRy.' A .r
w IW
4.
I L;I 1 ��31
t .
L---
�I � aa�w Ilk
wAQ I !b I I
L c
a �caw iv as
e� v
o _
k tk i gig _ CL
i E lz
B'''C'K MALL SM Y4ALL LAVATOI[GS
��-DAM AT i fM rad2mm CL1cAR}'LOOIt�AGt
5MMER FREE NOTES lb.
9 111 1
;111 DOORS RECd11RIN5 FlA1 U°82 PA5546E ARE TO HAVE A N�NllMUM CLEAR OFETHIN6 WIDTH 32'. TFE MAXINIM D}{£16N7 !!4 e
TO aBE St'ALONG ACCESSIBLE ROUTE OF TRAVEL. N 2 N ALL COMMON AND PUBLIC USE AREAS PROVIDE A MINIMLM OF 18'LW%TRUGTED FLOOR SPACE BEYOND 57RLKE JAMB ON THE SIDE `14
OF THE D�a , IF THE DOM 15 F-CLo51N6 AND° F{ATC1fIN5,PROVIDE 12'BEYOND 5TRIKE JAMB ON THE OPPOSITE SIDE OF THE
DOOR SHVING(A+oT APPLICABLE TO DOORS NOT REg11RIN6 FULL L5132 PA5546F�
3. AT ALL COMMON . MAX OPENING NEI6HT 85 Ite.AND KeLIC U5E AREAS PROVIDE A MINIKM OF 48'UNOB5TRUGTED PULLED FLOOR SPACE P9�PENDIGUAR TO THE
n
DOORKAY M!RE A DOOR MUST BE TO BE OPENED.
4. %HEE C AR.AGGFS51BLE TOILET STALLS 5HALL HAVE A CLEAR WIDTH OF 5'-0'. TI$DEPTH OF THE STALL SHALL BE 4'$'WITH 1^IALL+ING WATER
CLOSETS AND 4'-11'NTH FLOOR-MOUND WATER CLOSETS. �
5. PROVIDE A MI fKH OF 60'DIAMETER LP OBSTRUCTED 19'
KNEE AND TOE CLEARANCES NOT TO EX
FLOOR SPADE WITHIN THE TOILET ROOM. DOORS IN ANY POSITION MAY ENCROACH
INTO THE SPADE NOT MORE THAN 12',AND THE CLEAR FLOOR SPACE MAY INCLUDE CEED
EXTENDING L�dJ82 THE LAVATORY OR SINK.
6. PROVIDE 6RAB BARS OR REINFORCING FOR 6RAB BARS AT NIATER P
AND 3016(oc>)2A AND 3106(IJII. uO`'ET` ` I6TON STATE BUILDING CODE SECTTgd 3106(krSG
T. LAVATORY RIMTHE F IN15H SHAG. NOT HIGHER THAN 34'ABOVE THE FINISHED FLOOR WITH-W MINI"CLEARANCE FROM THE BOTTOM OF
THE APRON TO SHE FINSHED FLOOR fZE`fISIONS 6. PROVIDE AN UNOB5TRLCTED FLOOR SPACE 30'WIDE BY 48'DEEP AT EACH ACCE5515LE LAVATORY. THE CLEAR FLOOR SPACE MAY INCLUDE
KNEE AND TOE CLEARANCES NOT TO EXCEED 19'EXTENDING LtCER THE LAVATORY.
4. FROVIDE AN LHOE15TRUGTED FLOOR SPACE OF 6o'IN DIAMETER WITHIN THE KITGFEK
10.MAXIMUM RAW SLOPE TO BE 1:12 IN DIRECTION OF TRAVEL PER W5BC SECTION 31OW2. GROSS-SLOPES,OF RAMPS AND ACC S5
ROIJTES OF TRAVEL SFU1LL NKTT EXCEED 1:48 PER NHr.�BC SECTION 3106(o. 1BLE
11.IF RAMP SLOPE 15 6REATER THAN 1:20,PROVIDE HANDRALL5 PER W58C SECTION 5106".
12,ALL CONTROLS AND OPERATING HARDWARE AT COMMON AND FVBLIC USE AREAS WILL FLOO
1 BE LOCATED PER WSBG SEGTIGN 3106(c)2.
4. iN AGGESSIBLE DNELLIN61NIT5,OPERABLE WINDOW HARDWARE SHALL HAVE LEVER TYPE OR OTHER HANDLES OPERABLE BY WRIST,
ARM OR SHHOUAER AND BE LOCATED NOT LE55 THAN 36'AND NOT MORE THAN 48'ABOVE THE FINISHED FLOOR. 3106(c)2
14 ALL CONTROLS AND OPERATIN19 HARDWARE AT COMMON AND FUBUC USE AREAS WILL 13E LOCATED PM W586 SECTION 3106(c)2.
THE NNI5HED FLOOR 3106(c)2
Z
t57 3�
REGISTERED
ARCC► iTETECT
TMOMAS A.HERSTAO
STATE OF W HINGTON
mtul