Loading...
HomeMy WebLinkAboutFIR2000-00024 Final Automatic Fire Alarm System - FIR Permit / Conditions - 12/27/2022 MASON COUNTY PERMIT ASSISTANCE CENTER Inspection Line (360)427-7262 Mason County Bldg. 3 426 ',N. Cedar P.O. Box 186 Phone: (360)427-9670, ext. 352 Shelton, WA 98584 Irp, FIRE PROTECTION PERMIT FIR2000-00024 APPLICANT: NORTH MASON UNITED METH RECEIVED: 07/12/2000 CONTRACTOR: SITE ADDRESS: 25140 NE STATE ROUTE 3 BELFAIR ISSUED: /18/200 0 EXPIRES: 01/18/2001 PARCEL NUMBER: 123214300000 LEGAL DESCRIPTION: SW SE EX SEE BLA#93-22 AF#561021 NE 25140 STATE ROUTE 3 PROJECT DESCRIPTION: AUTOMATIC FIRE ALARM SYSTEM GENERAL INFORMATION System Information Type of Use: Commercial Sprinkler Heads: Audible Switches: Pull Stations: Fire District: 2 Flow Switches: Visual Devices: Door Releases: Hood & Duct?: Pressure Switches:: Smoke Detectors: Duct Detectors: Dry Chemical?: Zones: Heat Detectors: Wet Chemical?: Sprinkler?: Standpipe?: SQUARE FOOTAGE FEES Monitoring Station No.ADT First Floor: Type Amount Due Amount Paid Auto Fire Alarm?: Y Second Floor: Sprinkler System Fee $100.00 $100.00 Third Floor;: Total: $100.00 $100.00 Please sign, date, initial all conditions and mail back This project becomes null and void if work or construction authorized is not commenced within 180 dt9s,"PrT constru�1�Q r is suspended for a period of 180 days at any time after work is commenced. Evidence of continuation of work is a progress inspection within the 18'0 d Owner or Agent: Date: FIR2000-00024 Please refer to the following pages for conditions of this permit. 1 of 2 - CONDITIONS FOR FIR2000-00024 1.) 1. The fire alarm system is to be a total coverage system, which is to include smoke alarms in all occupied spaces and adequate coverage in the open basement area and the worship area. Additional detectors are required in the following areas: BASEMENT Mech/storage Heat RR Heat Open basement Smokes MAIN FLOOR SMOKE ALARMS Nursery Conference rooms Cry room Pastor's office Main office Narthex/fellowship/worship area HEAT DETECTORS RR Kitchen 2. Heat detectors are not required in the attic. 3. The fire alarm system is to monitor the following functions of the water supply system: Fire pump start Storage tank water level Future PIV tamper switch 4. Confirm that two phone lines will be connected to the FACP. 5. Please provide the second page of the permit application form---the contractor signature page. x Please sign, date, initial ali conditions and mail back to me. THANK YOU FIR2000-00024 Please refer to the following pages for conditions of this permit. 2 of 2 MASON COUNTY FIRE MARSHAL Mason County Bldg. III 426 W. Cedar P.O. Box 186 Shelton,Washington 98584 (360)427-9670 Ext.273 CODE ENFORCEMENT FIRE INSPECTIONS FIRE INVESTIGATION PUBLIC EDUCATION March 16, 1998 TO: Allan Borden Planning FROM: Dave Salzer SUB: North Mason United Methodist Church Fire protection comments: 1 . Provide a 20 foot wide fire apparatus access road to within 150' of any portion of the exterior walls of the building. 2. Provide fire flow as follows: 2400 gpm for 2 hours at 20 psi residual pressure. 3. A basement over 1500 square feet in floor area is required to be sprinkled. 4. Provide an automatic fire alarm system throughout, installed to Mason County standards and monitored by an approved central receiving station. 5. Provide lighted exit signs and emergency lights. 6. Provide a Knox Box emergency key box. Contact Mason County FD 2 to order the box. 7. Fire apparatus access road and fire hydrant system is to be in place and serviceable prior to the start of combustible construction. 8. Fire lanes will be located on final site plan. i-EXISIINC GRADING FA.D —— — — — — L /APPROX.RISER HEIGHTS NG VALVE — — — — — —� ING PORT .. ,4 OUND AFTER GRADING g o 6'OSI B107UBE :n i f j, ,.r _ �A 1S 1 .! rS ri g ENT FILTER n Yi `.'r: r,f ''.•' %•:• „�..`i �C.. ~ � � � • F w�` EL VNIES SEE SECTIONS �•S MiTH ALARM. nureoauc sea m TYPICAL 9 FEET EW DRIANFIELD SECTION 1200 GAL 1200 GALLON TWO 1500 GAL TANKS i 1200 GAL PRIMARY GREASE PLAN A /GROUND BEFORE GRADNG FOR PUMP TANKS TANKOF SURGE TANKS AND STEAN�IARY T P NGLAYQUT FOR FLUSHING VALVE DETAIL EMERGENCY STORAGE m ` ELEV. 263.1 OUND (S2ACItlC2112 i.- \\\— 291.5 TANK PROFILE 2 FEET :..'•k�Y,:,:-;' , ,,:y'r.,�, `.• p.: DOSING SPECIFICATIONS: DOSE EACH FIELD 4 TIMES A DAY ON A TIMED BASIS. EACH DOSE SHALL BE 125 NOTE: TANKS AND DRAINFIELD WILL BE 11 FEET GALLONS OR 3 - 3/8 INCHES OF EFFLUENT IN TANK. STAKED IN THE FIELD BY THE ENGINEER. FLOAT SETTINGS MEASURER FROM THE BOTTOM OF THE PUMP TANK DRAINFIELD NOTE: 1. ALARM FLOAT - 50 CLASS 1 SOIL (SAND AND GRAVEL) 2. PUMP ON OVERRIDE - 46- INSTALL 2' DEEP BY 11 FEET 9 FEET 3. PUMP OFF- 22' 0 WIDE ASTM C-33 SAND UNDER 4. REDUNDANT OFF - 16' 32 FEET pj NLET NO. 7 INFILTRATOR UNITS. 12- NS DRAINFIELD SECTION ALL FLOATS TO BE MECHANICAL FLOATS. OF PERVIOUS COVER OVER INFILTRATORS. LET 30 FEET NOTE: THE DESIGNER WILL ACCEPT ti A ONE PUMP SYSTEM. INSTALLER TO SUBMIT ALTERNATE DESIGN TO MCDH FOR APPROVAL. 3r a DRAINFIELD PUMP STATION EQUIPMENT SPECIFICATIONS - -� s / Mason County P�F78aY11 4 1. CAST 24"CIA. HOLES IN TANK TOP CONSTRUCT FLNGES To ACCEPT A 24•DIA. ORIFICE DETAIL / ��R�� ORENCO RISER ASSEMBLY. _�-- 3.PROVIDE N EXPLOSION PROOF SPLICE BOX INEACH OF THE sA PROVIDE AN OSI S8S SPLICE BOX THE UFIOR THE REDUNDANT S s�90 'n 6 OFF FLOAT FOR THE LAG PUMP AND N OSI S84 SPLICE `lV / / 9+ nay, 1 AUDIBLE LIGHT CHECK VALVE BOX FOR THE FLOATS FOR THE LEAD PUMP. / M1 \F POW `� D 4.2- OSI RR24-36 RISERS WITH FL249 LID FOR PUMP TANK RISERS. 5 5.SCREEN PUMP VAULT-OSI SVI560 WITH 15 INCH INFLUENT HOLE HEIGHT. ,/ / O 6•• 6.PROVIDE MECHANICAL FLOATS, TO MEET / CLASS 1-A ELECTRICAL CODES.PROVIDE WL UOUID LEVEL N ALARM (AUDIBLE), TIMER OVER-RIDE(LIGHT) TIMER OFF AND REDUNDANT OFF FLOAT FOR THE LEAD / PUMP AND A REDUNDANT OFF FLOAT FOR THE LAG PUMP. PLACE ALL FLOATS ON REMOVALABLE FLOAT TREES. 15'CONCRETE CULVERT .CB 7 7.OSI EFFLUENT PUMPS VE07H CAPABLE OF 54 GPM AT 37 FT TDH �\ GRATE E =276.00 f m \ TOTAL OF TWO.PROMOE CHAIN PULL FOR REMOVAL. \ J —` 8. 1,5 HOSE AND VALVE ASSMEBCOMPARTMENT HV2009X / Q 9. t,500 GALLON SINGLE COMPNTMENT PUMP TANK BY N45'59'07"W FRED HILL OR EXPRESS TANK. TANK AND FITTINGS MUST 10.00' ' BE WATER TIGHT AFTER INSTALLATION. A FIBERGLASS TANK MAY BE USED IF THE INSTALLER PROVIDES PROlEC110N \ ~•� WORKING VOL.=1500 GAL. AGAINST FLOATATION. V 10.OSI DUPLEX PUMP PANEL MOUNTED IN CONTROL ROOM DRAINFIELD PUMP STATION OF BUILDING, USE DAX2-IR-PT-RO-HT-OS-ETM-CT-PRL PANEL ti PROVIDE AREA LIGHT IN PANEL AREA. EVENT COUNTERS AND TIMERS / p NOT TO SCALE ARE REQUIRED FOR EACH PUMP. PUMP TANK / A'' CV ►�PIPING: ALL PIPE CLASS 200 PVC ? ,� 5'-8 INLET NO. 28 LATERALS = 1-1/4" PVC / / LET NO. A TRANSMISSION LINES = 2' CLASS 200 PVC i 7 i c TYPICAL NO. 2C 25 - 3/16 DIA. HOLES PER LATERAL - 75 HOLES PER BED AT 6 OCLOCK- TOTAL OF TWO BEDS 2 50 FEET AS —/ INLET NO. 1 ALE 1� VALVE BOX 1 �j WITH BALL VALVE FOR EACH LATERAL \ a SET COVER AT \ Z`J LANDSCAPE GRADE. y` z / � 0 36 60 90 � — - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� \ arsiriefat ''9�y,\ LET 130' 12" HICOR INLET 3 GBSERVAPON PORTS DRAINFIELD PLUMBING PLOT PLAN SCALE: 1"=30' ASSUMED DATUM REVISIONS BY DATE ON SITE WASTE WATER PLAN FOR: NORTH MASON UNITED SCALE: 1'- 30' NO. DATE BY DESCRIPTION DESIGNED PM MA41" Engineering Services Associates, Inc. METHODIST CHURCH DATE: JULY 25. 1999 1 6 30 PM REVISED TO FIT MCDH COMMENTS. DRAWN PM e/u/A (3W) 275-7384 Within the Southwest Quarter of the Southeast Quarter of DRAWING NUMBER 2 10/2 PM MOVED DRAINFIELD.- CHANGED TANKS ETC. CHECKED APPROVED rD NE Ch.akw Bad,fimr,�.9652e Section 21, Township 23 N., Range 1 W., W.M. BELFAIR, Wi4.SH/NGTON ACCEPTED Mason County, Washington SHEET 2 OF 2