HomeMy WebLinkAboutBLD Engineering / Geo-tech Reports - 9/2/1998 'T`RUCTURAL CALCULATIONS - USING 1997 UBC 7110 PACIFIC HWY. E. MILTON, WA for MS. LINDA PLEIN CONTRACTOR: DO NOT USE THESE CALCULATIONS FOR CONSTRUCTION. SEE STRUCTURAL DOCUMENTS FOR ENGINEERING ReQUIREMENTS. V A oa ✓ Oy 26473 Oz�SE T +G EXPIRES J Project No. 98265 ANDREWS ENGINEERING - Structural Engineering 4924 109TH St. S.W. Suite A Lakewood, WA 98499 (253) 584-3475 ANDREWS ENGINEERING Job No. 98265 .0roject: 7110 PACIFIC HWY E. MILTON, WA 9/1/98 By;Sandra Conklin 1 OF 11 I. SCOPE OF WORK Perform lateral and gravity analysis on garage structure. Prepare Structural Documents containing engineering requirements. II. DESIGN CODES/LOADS Current building code as amended and adopted by Local Jurisdiction. LOADS ROOF: RFG 3.0 PSF PLY 1.5 FRAMING 3.0 INSUL. 1.5 CEILING 2.5 MISC. 1.0 ROOF DL 15 .ROOF SL 25 ROOF TL 40 PSF III. WIND DESIGN PRESSURES "P" Exposure C, Wind Speed 80 mph Ce15 = 1.06 0 to 15 feet Cc20 = 1.13 15 to 20 feet qs = 16.4 lb ft2 Ce25 := 1.19 20 to 25 feet I - 1.0 Ce30 = 1.23 25 to 30 feet Cq 1.3 Wind Pressure (psf) Height Above Ground P1 =gs•hCq Cel5 PI =22.6•lb•ft-2 0'to 15' 112 qs-I Cq Ce20 P2 =24.09•lb-£t 2 15'to 20' P3 =qs I Cq-Ce25 P4 =qs-I.Cq Ce30 P3 =25.37•lb•ft 2 20'to 25' P4 =26.22•lb•ft 2 25'to 30' IV. SEISMIC DESIGN Zone 3 Light framed wood structure Wind Controls By Inspection ANDREWS ENGINEERING Job No. 98265 Project: 7110 PACIFIC HWY E. MILTON, WA 9/1/98 By: Sandra Conklin 2 OF 11 V. WIND LOADS PER FOOT LENGTH OF STRUCTURE wl =P1.8-ft wl = 180.79•lb•ft-t w2 =P1.l0ft w2 =225.99•lb•ft t VI. SHEAR ON SHEAR WALLS LI =2441 L2 =40•11 Wall A: Wall B: La =3.5 ft Lb -24 1t wl L1 .5 v,b = w2 L2 .5 va =— Lb La va=619.86•lb-ft—t vb = 188.33•lb•ft t VII. OVERTURNING MOMENT ON WALLS 1IW = 12 ft 1 st floor walls Shear Length Overturning Moment Wall A La l 3.5 ft OTMa l va La 1 I1W OTMa l =26034.28.16•ft B Lbl =24ft O'IMbI vb Lbl-1IW OTMbI =54238.lb•ft Vill. SHEAR WALL DEAD LOAD RESISTING MOMENT 15 psf for di used to take account of loads from adjacent walls. Shear Dead Load on Wall Dead Load Resisting Moment Wall Roof Wall Al DLRFaI 7 14 ft.15—lb Lal DLWLal =HW 10- lb—.Lal DLaI DLWLaI + DLRFaI ftZ frz DLRFal =735•lb DI WLal =420•lb DLal = 1155•lb DLRMa l =DLa 1-La 1-.5 DLRMal =2021.25•lb•ft ANDREWS ENGINEERING Job No. 98265 Project: 7110 PACIFIC HWY E. MILTON, WA 9/1/98 By: Sandra Conklin 3 OF 11 61 DLRFbl :=2•ft•15-lb•Lb1 DLWLbI :=HW•2-10-1b•Lb1 DLbI :=DLWLbI +DLRFbI ft2 ft2 DLRFb 1 =720•lb DLWLb 1 =5760•lb DLb 1 =6480•lb DLRMb 1 :=DLb 1•Lb 1•.5 DLRMb 1 =77760•lb•ft IX. HOLDOWN FORCES WALLS Al _ 07'Ma1 - DLRMaI IIDFaI =6860.87•lb Lal B 1 HDFb 1 :=OTMb 1 - DLRMb 1 HDFb I =-980.08•lb Lbl Xl. SHEAR WALL SUMMARY Al va=619.86•lb•ft 1 11DFall =6860.87.1b 8d@4" B.S., 1-0, HDBA OR PHD8 S11 OR S14 1 B1 vb= 188.33.lb•ft I HDFbl =-980.08•lb w2•L22 8 =1883.27•lb max chord force. Ll min nail of splices per code o.k. ANDREWS ENGINEERING Job No. 98265 Project: 7110 PACIFIC HWY E. MILTON, WA 9/1/98 By:Sandra Conklin 4 OF 11 SHEAR WALL SCHEDULE (SEE ATTACHED REDUCED FLOOR PLANS FOR SHEAR WALL LOCATIONS) Shear Sheathing Panel Edge Holdown Sole Plate Nailing Applicable Detail(s) Wall (See Ftnt 1) Nailing (See Ftnt. 3) Anchor Bolt Spacing (See Ftnt. 2) 1 1/2" PLWD OR 8D@4" HD8A OR PH8 OSB BOTH SIDES A.B. @ 1'-0" O.C. S11 OR S14 FOOTNOTES TO SHEAR WALL SCHEDULE: (1). EXTERIOR SHEATHING ON EXTERIOR WALLS NOT INDICATED ABOVE SHALL BE 15/32" CDX PLWD, OR 7/16" OSB, APA RATED SIDING. EXTERIOR WALLS NOT ON SCHEDULE SHALL HAVE MINIMUM PANEL EDGE NAILING OF 6d @ 6" O.C. NAILING AND STAPLING 12" IN FIELD EXCEPT 6" O.C. FOR 24" STUD SPACING. (2). MINIMUM 2 ANCHOR BOLT PER WALL. 12"MIN FROM ENDS. PROVIDE 2" X 2"X 3/16" SQUARE WASHERS ON ALL ANCHOR BOLTS. (3). ALL HARDWARE SHALL BE SIMPSON BRAND OR EQUAL. ANDREWS ENGINEERING Job No . 98265 Project : 7110 PACIFIC HWY E. MILTON, WA 9/1/98 'By: Sandra Conklin 5 OF 11 STRUCTURALNOTES: 1. PROVIDE 2X6 BLOCKING BETWEEEN ALTERNATE TRUSSES AT RIDGE. CONNECT SLAT EITHER SIDE OF RIDGE TO BLKG WITH 8d@6". 2. PROVIDE ROOF SHEATHING OR 1X6 SLATS 3" BETWEEN SLATS ON ROOF FRAMING. CONNECT SLATES TO TRUSSES WITH (2) 8d NAILS. NAIL SHTG MIN PER CODE. 3. INSTALL HURRICANE CLIPS AT EVERY TRUSS SUPPORT. 4. CONNECT ENDS OF HEADERS TOGETHER WITH SIMPSONLSTA36 STRAP. CONNECT SHEAR WALL SHTG TO HEADER WITH 8d@3"O.C. EDGES AND IN FIELD. 5. CONNECT BOT CHORD OF GABLE END TRUSSES TO TOP PLATES WITH 8d@4" O.0 TOE NAILS. 6. MINIMUM GRADE OF WOOD ASSUMED FOR BEAMS, (VISUALLY GRADED PER WCLIB, WWPA): DOUG FIR NO. 2 OR BETTER, JOISTS AND RAFTERS HEM FIR NO. 2 OR BETTER UNLESS NOTED OTHERWISE ON REDUCED FRAMING PLANS. ANDREWS ENGINEERING 2/2/97 OF XII. GRAVITY ANALYSIS: Prefabricated roof trusses are not included. Trusses to be designed and stamped by a engineer licensed in the state where structure is to be located. See the attached reduced framing plans for the locations of the numbered beams on the following sheets. The beam Type, (A thru H) given below beam number referes to the type of loading on the beam. See this sheet and following sheet for the free body diagram of each loading type and applicable formulas. TYPE A 1.5-1 'U1d Span - U1dl Uld Mmax :=U1d-Span2 f�max I 2 J JJ 8 A \ Span TYPE B SPAN/2 P Mmax P Span fivmax 1.5-P-.5 4 A Span TYPE C P Uld-Span Span 1.5 Uld-S an� - Uld+ P SPAN/2 Mmax +P fNmax J Uld 8 4 A Span TYPE D P�a b a P b Mmax := Span if a<b f�max = 1.5-P b 1 Span A if a>b Amax .= 1.5 P a Span A Span TYPE E Uld-a-�b+a Ra:= 2 MCI Span S Ra Amax 2 Mmax = . 1.5-(Ra- Uld) Q b = Uld A Ra SPnn ANDREWS ENGINEERING 1/21/97 OF TYPE F P Uld•a• b+ a— +P•b Uld Ra = 2 Span a b if Ra/Uld <a Ra Span Z 1.5•(Ra- Uld) .5•Ra f�max _ Mmax Uld A if Ra/Uld =a Mmax :=(P- Ra)•b Rmax _ 1.5•(Ra- Uld) A or fvmax = 1.5•(P- Ra) A TYPE G Pl P2 Ra - 11V(Span- a)+P2•(Span- a- b) Span a b if Ra </= PI Ra Span Rb Mmax :=Ra•a fmax = 1.5-Ra or Amax 1.5•Rb A A ifRa > P1 Mmax :=Rb•(Span- a- b) TYPE H Amax .= 1.5•P P P Nimax :=P•a A a a Span ANDREWS ENGINEERING Job No . 98265 Project: 7110 PACIFIC HWY E. MILTON, WA 9/1/98 By: Sandra Conklin 8 OF 11 1 TYPE A Fb 2200.1.15 Fb =2530 A :=5.125.9 A=46.13 CHECK 5-1/8 X 9 GLULAM Fv:= 165.1.15 Fv = 189.75 S :=5.125.92 S=69.19 6 Span :=10 Tw :=12 Uld :=40•Tw Uld =480 Mma.x :=Uld'Span Mmax=6000 fb :=Mmax.12 fb = 1040.65 O.K. 8 S 1.5-Uld. Span- .751 fv := 2 / fv =66.34 O.K. A CHECK CONTINUOUS FOOTINGS Uld - 14.1-40+80 LJId =640 640 plf o.k. for max soil pressure o.k. for 12"wide footing. 2 LONG STUDS AT Suptg trusses Doug Fir or Hem Fir Stud Grade 2X6 @ 16"O.C. Table 23-1-A-1 Fb :=675.1.67 Fb=1127.25 A:=1.5.5.5 A=8.25 H :=12 Fc :=800.1.67 Fc=1336 S 1.5.5.52 S=7.56 Design Wind pressure on stud 6 (is - 16.4 I 1.0 Ce15 1.06 Cq :=1.2 P4 :=gsI-Cq Cel5 P4 =20.86 psf wall elements P4• 16 Hz Mrnax = 12 Mmax =500.66 fb :=Mmax.12 fb =794.43 8 S Pr (27.5).2.14 Pr =770 dl+1/2 snow+wind load combination fc :=Pr fc =93.33 psi A FcE := •3.1400000 FcE=612.7 H•12 rl 1 + FcE [( 5.5 C := Fc C =0.91 FcE 'S 2•.8 — fc 2 fb FC1 :=Fc• C- C2_ Fc Fcl =539.59 + =0.86 •8 Fcl 1_ fc FCE, O X r� - � of 0 1. 1 P 1 � 1 1\ 1 - tc' 71 1� C4',:u ado� . ov II / •' I � ' I I 1 I •I i I � I I i j i t � i .. I I �t � � t 14 I i I , i I i I � � i I � I � ` 1 1 • , : � : � � I I i i I I i w I � l al I I z � � I I z� l II I � I �I L � (A2339-ROM-001 - 24T) THIS DWG PREPARED IRON COMPUTER INPUT (LOADS A DIHENS(0115) SUBM(TTEO BY TRUSS MFR. TOP CHORD 2x4 DF-L 416Bet. ROOF OVERHANG SUPPORTS 2.00 PSF SOFFIT LOAD. o BOT CHORD 2X4 DF-L #18Bet, WEBS 2x4 HF Stud DEFLECTION MEETS L/240.00 LIVE AND L/180.DO TOTAL LOAD. N O 10 PSF SC LIVE LOAD PER UBC. x W a z xxo F y t C7 z W4X4 W15X4 -41# 415X4 Ay -� 4 z W 4.3-15 wz - a. a W3X5 = W5X5 W3X5(A1) W3X5(Al) lez•o-owl L<z 0 0'.1 E 6-4-I4 ) - 5-7-2 _1_ 5-7-2 ) 6-4-14 N 8-3-4 T 7-5-B 'T` 8-3-4 L_ 12 0 0 12-0-0 I i 24-0-0 Over 2 Supports R-1144 W-5.5" R-1144 h'-5.5' P!T TYP. Wave TPI-95 Design Criteria: TPI STD WA 1 - F Scale -.25" Ft. TRUSSLTIRA CCTRG.OARG It TO NIB OL (IAVOL IIII I SMALL(AE IN C2 AMU RRIACI1a)29, XAY OCaLISNCa IY TPJ JNf T k U SS II ATC TC LL 25.0 PSF REF RA40--19221 IR S T I TIE E. 1 O O'OICFEE] al.. SI(lC 100, HAD,DON, VI S)III), FOR SAFETY It ACT(CIS ]AI6R Ta PERFORN(MI rAISC fUMCfJOI3, III.CS]OTHEAYISI IPd1CAlCa, Tar cicia SMALL NAY( PROFEILY ATYACNCD _ TC DL 7,0 PSF DATE 08/25/98 SIRYC TUTAI PA YEL3, Na TTOI CKIRD SNACL NAYS A PRO?[RtY ATfACHEI RIG]/ Ci TLIIIti "JmPlArAAT•• F4AMISH A COPY OF THIS ICSTGN TO THE INSIALLAPION CONTRACTOR- ALPJN[ CMGII[ERE C DL 10,0 PSF [DRW WAUSRA4G 960875021 p0 IAOLIE JIC, IMAlI Of OC 0.CSPOM3[I lC FOR ANY 0[Il ATt O.Y FR ON IN 1S DL SIM; AYT FAICUIE 10 �Q I UlLO 11[ TWSS(S IV COVOLIAVC[ VItN TP t: OR FAMFUCATINa, NA,11.IRG, Stl I]PIAG, (TSTALLLSG AAD yv2 �1 \ aRAma OF TIUSS(3. TN15 0[SIaY COSFORIIS RITN AIPLIC:l9lC PtO/1510Yi aF VOS (NAf10NAl O,S/av BC LL 0.0 PSF WA-ENG /DT n S7LCIFIm Aq 1MBL,SNII YY iN[ AN(RICAM F011MAL - S PAPER ASSOCIAS )IO AND i►I. ALIINf TDT.LD. 42.0 PSF SEQN 44665 N CO YMCC TOE] ARC MADE a IOGA ASTM Ad►7 GSIO IAU- STEEL. EXCEPT AS MO T,D, APPLY COMMECTOIS TO \ IACM FALL aF TkISS, AAO UAIESS'OTHIIY(SC LOCATED ON TH(3 D[311N. Palf,ION CONNECTORS PEA x0 OIAYIMOS 16I A I. TV SEAL Of THIS ORAN(YI [AJICATCS ACCEIIANC! OF JAOF[SSlaYAL (WRITHING F A C. 1 .15 FROM K J S O AJplfl0 Hn8iAcmvd Pcodma,Ina. ;kEv0N]f11LITY SOLELY FOA TAL TRUSS CONPOIICET DESIII SNOMV. TN( SN1rA11L(TY ANa -lS[ Or THIS OPII� �1�`ptT 1 TM,=v,WA98424 COYPONCMI FOR AN Y PILT(CULAM (U(LO(MO [S THE LLSJONSIBIL(lY IF TN[ 3ITU) a OCSI:N[R, PGA SPAC111 7 24,Oa AN31ITYT 1-1991 SECTION 1. (A2739-ROM-001 - 24T) THIS DWG PREPARED FROM COMPUTER INPUT (LOADS 8 DIH►NSIONS) SUBMITTED BY TRUSS MFR. ' TOP CHORD 2x4 DF-L #1&Bet. ROOF OVERHANG SUPPORTS 2.00 PSF SOFFIT LOAD. o OOT CHORD 2x4 DF-L #198et, o WEBS 2x4 HF Stud 4 DEFLECTION MEETS L/240.00 LIVE AND L/180.00 TDTAL LOAD. 0 0 10 PSF 8C LIVE LOAD PER UBC, x w a z 0 x H (n r z W4X4 = x w W I S X 4 A# z 4 F— W15 X4 4 z —, a w 4.3-15 a .a W3X5(A1) = 0 X5= W5X5 W3X5(A1) L,2 0 0-3,) LE2.0-owl UID 6-4-I4 5-7-2 5-7-2 6-4-14 7-5-8 co -4 12-0-0 I 12 0 0 8-3-4 o f� 24-0-0 Over 2 Supports R-1144 W-5.5• R-1144 W-5.5' .V I` PlT W. Wave TPI-95 Design Criteria: TPI STD 1 WA 1 - F Scale —.25" Ft. •NARN(NO•- TRUSSES REWIRE "'REM( CARE IY FAIL11CATION, NAYOL I YB. SNTPIINO, 1MSTALLINO AND u. ARACTNG, RI:CR 10 NIB-OL (RAVOL(YG IVSTALLIAC AND BRACING)- 9YaLLSNCO RY T►1 (TRUSS PLATE 04 NOT TC LL 25.0 PSF REF RA40- -19221 •I [N ST1T0 fE, SRC D'ONCF0.10 01., SO(IF 200. MAD ISOW. Vl 5)I12). FOR SArCTY PRACT(CIS IAIGR TO -,H PCP.FORN(YN TdISC FUNCTIONS. ONLIIS OTHERVISI ING11A1r0, roP cXDRG SHALL HAVE PROPERLY ATTACHED A' TC DL 7.0 PSF DATE 08/25/98 S IRNCTURAI PAYELS, BOTEON Ci.9Pf) SHALL HAVE A PRO►(RCY ATTACHED RIGID CEILING_ ••1HPD.2fA.W1•• F4AN(SN A COPY a TNIS OISiGN TO THE 1XSfALLA11oN CONTRACTOR_ ALPINE CNCINEIRE 9C DL l0.C PSF DRW NAUSRA40 980825021 20 . IAODUCTS, ]NC, SNAIL N01 BE RESPONSIBLE FOR ANY OEIIAT1W FROM THIS Di SIGN; AVY FAICVAE 10 �Q 00 BU1L0 1NE TtUT5I3 IN[ORFOLRAYCC VIfX TP(,- OR FABRICATING, HAJMiIIfh:. SNIIPIAG. (YSTAII[.1G AAO 27_ ]50 gC L�. D.0 PSF WA-ENG /OT \ BRAC(A0 OF iRUSSCS. TNIS OISIOY CDAFORMS NITN AIPLICASLE PROLISLOVS OF NOS (HAIIONAL OESIGV F`R'. fE�eO IZ� S)CCIF{CA((ON PRBL[SILO AY TNi ANERICAV FCRCST AN0 PAPER ASSOCIAIIONJ AND T►I. ALIIHE 7V [CL•NCCfOE3 ARE MADC fF ZOC;A WIT A657 G140 BALL- 5TELL. EXCEPT AS HGrt0, APPLY CONHECTOAS TO j�NAL G TOT.LD. 42.0 PSF SEQN - 44665 \ EACH FACE OF TkOSS, AIO "Al EST 0THIRY(SC LOCATED 08 TH(S OESIBN. POS(110N CONNECTORS P(i ID DRAVINOS 190 A•Z. TYr SEAL 04 TN(S OR HELD LWICATCT ACCE)IANCE OF IAOFESSIOVAL (WO(NCERINC 0 U R.F A C, 1 Z 5 FROM K J S AJpliwBngEmearadProdDIGEY,Ina, iCSAONSr9JLLTV SOLELY FOi T!C TRUSS CONPOHEIT DESIBR SHONV- THE SDLrABILITP AND-IS[ Of TNIS 6-16=99- TYcamti 1YA 99424 CON ET P')MEN1 FOR ANY PAICULAR RUILOINO fi THE LCS%ONSI8IL(1V IF THE 3OTLDINO DESIGNER. PEA wpmANSIITPI 1-122! SECTION 2, SPACING 24,0"